HL-2M 装置扫频 ECE 测量系统研制
引用本文:方凯锐,杨曾辰,石中兵,余 鑫,佟瑞海,蒋 敏,HL-M 研制团队.HL-2M 装置扫频 ECE 测量系统研制[J].核聚变与等离子体物理,2021,41(Z2):538-543.
作者姓名:方凯锐  杨曾辰  石中兵  余 鑫  佟瑞海  蒋 敏  HL-M 研制团队
作者单位:(1. 核工业西南物理研究院,成都 610041;2. 大连理工大学,大连 116024)
基金项目:国家重点研发专项(2017YFE0301203,2017YFE0301106,2017YFE0300500);国家自然科学基金(11705049, 11705051,11775070,11875017);四川省科技计划项目(2018RZ0123)
摘    要:为了测量 HL-2M 装置中的电子温度剖面分布,研制了一套扫频电子回旋辐射(SECE)系统。该系统 能够测量装置中心纵场大小在 1.4~2.2T 时的等离子体电子温度。采用扫频外差接收的方式,径向空间分辨达到 2.5cm,时间分辨达到 1ms。接收机前端的准光学系统采用两级金属反射镜的配置,系统能够接收的最小极向光 斑的直径为 1.5cm(波数 kθ<4.2rad·cm-1)。系统的频带范围覆盖 33~110GHz,采用 VCO 作为本振源,双边带混频 输出中频信号。后端首次采用高性能对数检波器解调中频,能直接对-70dBm 的微弱信号进行检测,输入-输出工 作区间的动态范围达到 45dB 以上。在实验期间,成功测量到了等离子体中电子逃逸以及回旋辐射产生的信号。

关 键 词:电子回旋辐射  外差式辐射计  扫频  对数检波器  电子温度测量  
收稿时间:2021-05-14

Development of a sweeping-frequency ECE diagnostic on HL-2M tokamak
FANG Kai-rui,YANG Zeng-chen,SHI Zhong-bing,YU Xin,TONG Rui-hai,JIANG Min,HL-M Development Team.Development of a sweeping-frequency ECE diagnostic on HL-2M tokamak[J].Nuclear Fusion and Plasma Physics,2021,41(Z2):538-543.
Authors:FANG Kai-rui  YANG Zeng-chen  SHI Zhong-bing  YU Xin  TONG Rui-hai  JIANG Min  HL-M Development Team
Institution:(1. Southwestern Institute of Physics, Chengdu 610041;  2. Dalian University of Technology, Dalian 116024) 
Abstract:In order to measure the electron temperature profile on HL-2M, a sweeping frequency electron  cyclotron emission (SECE) system is developed. The system can measure electron temperature of plasma with the  center toroidal field of 1.4~2.2T. The radial spatial resolution is 2.5cm and the temporal resolution is 1ms by using  the method of frequency-swept heterodyne radiometer technique. The quasi-optical system at the front of the  receiver is equipped with two-stage metal mirrors. The minimum diameter of a poloidal spot that the system can  receive is 1.5cm (wave number kθ<4.2rad·cm-1) The system covers 33~110GHz bandwidth with 3 voltage  controlled oscillators (VCO) used as the source of local oscillators (LO), and the intermediate frequency (IF)  signal is output by mixing in double sidebands. The backend uses high-performance logarithm detector to  demodulate IF signal for the first time, which can detect the weak signal of -70dBm. The dynamic range of the  input power reaches 45 dB. During HL-2M experiments, the signals generated by runaway electrons and electron  cyclotron emission (ECE) in plasma were measured successfully. 
Keywords:Electron cyclotron emission  Heterodyne radiometer  Sweeping frequency  Logarithmic detector  
  Electron temperature measurement 
  