首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   68篇
  免费   9篇
  国内免费   17篇
化学   59篇
力学   5篇
物理学   30篇
  2024年   1篇
  2023年   4篇
  2022年   4篇
  2021年   1篇
  2020年   5篇
  2019年   3篇
  2018年   2篇
  2017年   5篇
  2016年   2篇
  2015年   6篇
  2014年   7篇
  2013年   4篇
  2012年   5篇
  2011年   5篇
  2010年   3篇
  2009年   10篇
  2008年   3篇
  2007年   4篇
  2006年   3篇
  2005年   5篇
  2004年   7篇
  2003年   2篇
  2001年   2篇
  1988年   1篇
排序方式: 共有94条查询结果,搜索用时 42 毫秒
1.
Recent years have seen the emergence of capacitive deionization (CDI) as a promising desalination technique for converting sea and wastewater into potable water, due to its energy efficiency and eco-friendly nature. However, its low salt removal capacity and parasitic reactions have limited its effectiveness. As a result, the development of porous carbon nanomaterials as electrode materials have been explored, while taking into account of material characteristics such as morphology, wettability, high conductivity, chemical robustness, cyclic stability, specific surface area, and ease of production. To tackle the parasitic reaction issue, membrane capacitive deionization (mCDI) was proposed which utilizes ion-exchange membranes coupled to the electrode. Fabrication techniques along with the experimental parameters used to evaluate the desalination performance of different materials are discussed in this review to provide an overview of improvements made for CDI and mCDI desalination purposes  相似文献   
2.
熊岳城  于飞  马杰 《物理化学学报》2022,38(5):2006037-31
电容去离子技术(Capacitive deionization,CDI)是一种新兴的脱盐技术,通过在电极两端施加较低的外加电场除去水中的带电离子和分子,由于其较低的能耗和可持续性而备受关注。基于储能电池领域近年来的迅猛发展,CDI电极材料实现了从以双电层作用机理为代表的碳材料到法拉第电极材料的跨越,使得脱盐性能有了大幅度提升。Na+的去除与Cl-的去除同等重要,然而,CDI中针对氯离子高效去除的电极材料研究关注较少。本文从CDI装置的构型演变发展出发,系统地归纳与梳理了CDI中关于脱氯电极材料的分类,对比了不同类型脱氯电极材料的特点,并总结了Cl-去除的机理,分别为基于双电层的电吸附、转化反应、离子插层和氧化还原反应。本文是首篇关于CDI阳极材料的进展综述和展望,为CDI除氯电极的后续研究提供理论基础和研究思路。  相似文献   
3.
《力学快报》2020,10(1):23-26
Piezoresponse force microscopy(PFM) has emerged as one of the most powerful techniques to probe ferroelectric materials at the nanoscale, yet it has been increasingly recognized that piezoresponse measured by PFM is often influenced by electrostatic interactions. In this letter, we report a capacitive excitation PFM(ce-PFM) to minimize the electrostatic interactions. The effectiveness of ce-PFM in minimizing electrostatic interactions is demonstrated by comparing the piezoresponse and the effective piezoelectric coefficient measured by ce-PFM and conventional PFM. The effectiveness is further confirmed through the ferroelectric domain pattern imaged via ce-PFM and conventional PFM in vertical modes, with the corresponding domain contrast obtained by ce-PFM is sharper than conventional PFM. These results demonstrate ce-PFM as an effective tool to minimize the interference from electrostatic interactions and to image ferroelectric domain pattern, and it can be easily implemented in conventional atomic force microscope(AFM)setup to probe true piezoelectricity at the nanoscale.  相似文献   
4.
电容式编码器是一种新型、耐用、可靠和准确的编码器。由于电容式编码器编码的原理不同于传统的光学式和电磁式编码器,其输出的位置信息是经过两路激励信号调制后的正弦波形,与传统的正余弦(和)和方波(PWM)输出方式差异较大,因此其信号检测技术也和传统的编码器有很大的差别。为了精确地获取电容式编码器输出信号中所携带的位置信息,本文设计了一套基于现场可编程门阵列(FPGA)的电容式编码器数据采集系统。文中介绍了带通滤波器、同步正交解调、低通滤波器和Cordic等算法,并详细分析了系统的稳定性和误差。实验结果表明,系统能够实时的获取转子的位置信息,同时具有较好的分辨率和精度。  相似文献   
5.
根据容栅传感器的检测原理,设计了一套基于LabVIEW和容栅传感器的液位精密测控系统,精度达0.05ml。利用容栅传感器输出的电容信号经信号调理模块输入msp430单片机处理并精密控制液位,采用LabVIEW设计系统监控界面程序,实现系统数据的显示、存储、绘图以及人机控制测定仪工作等功能。可配装为数显测定仪和物体密度测量仪,人机界面良好,成本低,易推广。  相似文献   
6.
7.
A capacitive immunosensor for detection of cholera toxin   总被引:2,自引:0,他引:2  
Contamination of food with biological toxins as well as their potential use as weapons of mass destruction has created an urge for rapid and cost effective analytical techniques capable of detecting trace amounts of these toxins. This paper describes the development of a sensitive method for detection of cholera toxin (CT) using a flow-injection capacitive immunosensor based on self-assembled monolayers. The sensing surface consists of monoclonal antibodies against the B subunit of CT (anti-CT), immobilized on a gold transducer. Experimental results show that the immunosensor responded linearly to CT concentrations in the range from 1.0 × 10−13 to 1.0 × 10−10 M under optimized conditions. The limit of detection (LOD) was 1.0 × 10−14 M. Two more analytical methods were employed for detection of CT using the same antibody namely, sandwich ELISA and surface plasmon resonance (SPR)-based immunosensor. The former had an LOD of 1.2 × 10−12 M and a working range from 3.7 × 10−11 to 2.9 × 10−10 M whereas, the later had an LOD of 1.0 × 10−11 M and a linearity ranging from 1.0 × 10−9 to 1.0 × 10−6 M. These results demonstrate that the developed capacitive immunosensor system has a higher sensitivity than the other two techniques. The binding affinity of CT to the immobilized anti-CT was determined using the SPR-based immunosensor and an association constant (KA) of 1.4 × 109 M−1 was estimated.  相似文献   
8.
This paper describes a new capacitive structure of pressure sensor to increase simultaneously the sensitivity and the linearity of the transducer. This structure contains two capacitors which change in response to pressure, but in opposite senses. To increase even more the sensitivity of each capacitor, the pressure sensitive diaphragm carries a central boss. The optimal position and the length of the boss are also calculated. To cite this article: A. Ettouhami et al., C. R. Mecanique 332 (2004).  相似文献   
9.
We investigate quantum dot arrays and their application to quantum computation. The arrays analyzed contain a total of a few operating electrons with constant tunneling between the dots. We construct quantum two-level systems near the ground state with a large energy separation to the remainder of the states and with the electrostatic interaction modeled within the capacitance matrix formalism. A set of representative examples is investigated numerically.  相似文献   
10.
《Electroanalysis》2018,30(5):901-909
We report in this work the development of a novel capacitance electrochemical sensors based on silicon nitride substrate (Si3N4) chemically modified with a structure of Cobalt phthalocyanine, C,C,C,C‐tetracarboxylic acid‐Polyacrylamide (Co(II)Pc‐PAA). This sensitive layer was tested with and without magnetic nanoparticles (MNP) for perchlorate ( ) detection. The developed chemical sensor with Si3N4/APTES‐MNP/Co(II)Pc‐PAA structure has shown a better performance when compared to the other structure based on Si3N4/Co(II)Pc‐PAA. Contact angle measurements (CAM) and atomic force microscopy (AFM) characterizations have been performed to characterize the functionalization of the chemical sensors surface. Under the optimized structure of the chemical sensor, electrochemical measurements were carried out using Mott‐Schottky analysis for detection within the large range of 10−10 to 10−4 M with a very low detection limit of 2×10−10 M. The chemical sensor has demonstrated a high selectivity toward when compared to other interfering anions such as Cl, SO42−, and CO32−. The present capacitive chemical sensor is very promising for sensitive and rapid detection of for environmental applications.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号