首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   42篇
  免费   1篇
  国内免费   1篇
化学   30篇
数学   6篇
物理学   8篇
  2021年   1篇
  2017年   1篇
  2016年   2篇
  2015年   1篇
  2014年   2篇
  2013年   2篇
  2012年   1篇
  2011年   2篇
  2010年   3篇
  2009年   6篇
  2008年   2篇
  2007年   8篇
  2006年   2篇
  2005年   3篇
  2004年   2篇
  2003年   1篇
  2002年   4篇
  1999年   1篇
排序方式: 共有44条查询结果,搜索用时 31 毫秒
1.
A prominent trend which has been observed in recent years in the analysis of veterinary drugs and growth-promoting agents is the shift from target-oriented procedures, mainly based on liquid chromatography coupled to triple-quadrupole mass spectrometry (LC-QqQ-MS), towards accurate mass full scan MS (such as time of flight (ToF) and Fourier Transform (FT) Orbitrap MS). In this study the applicability of high resolution single-stage-Orbitrap-MS for confirmatory analysis of growth-promoting agents in meat was compared to that of a QqQ-MS. Validation according to CD 2002/657/EC demonstrated that steroid analysis based on Orbitrap MS, operating at a resolution of 50,000 FWHM, is indeed capable to compete with QqQ-MS in terms of selectivity/specificity, while providing excellent linearity (for most compounds >0.99) but somewhat inferior sensitivity. Indeed, CCαs reached from 0.04–0.88 μg kg−1 for the 34 anabolic steroids upon MS/MS detection, while upon Orbitrap MS detection a range of 0.07–2.50 μg kg−1 was observed. Using QqQ-MS adequate precision was obtained since relative standard deviations, associated with the repeatability and intra-laboratory reproducibility, were below 20%. In the case of Orbitrap MS, for some compounds (i.e. some estrogens) this threshold was exceeded and thus poor precision was observed, which is possibly caused by the lack in sensitivity. Overall, it may be concluded that Orbitrap-MS offers an adequate performance in terms of linearity and precision but lacks in sensitivity for some of the compounds.  相似文献   
2.
The last 2 years multi-compound methods are gaining ground as screening methods. In this study a high-resolution liquid chromatography combined with time-of-flight mass spectrometry (HRLC–ToF-MS) is tested for the screening of about 100 veterinary drugs in three matrices, meat, fish and egg. While the results are satisfactory for 70–90% of the veterinary drugs, a more efficient sample preparation or extract purification is required for quantitative analysis of all analytes in more difficult matrices like egg. The average mass measurement error of the ToF-MS for the veterinary drugs spiked at concentrations ranging from 4 to 400 μg/kg, is 3.0 ppm (median 2.5 ppm) with little difference between the three matrices, but slightly decreases with increasing concentration. The SigmaFit value, a new feature for isotope pattern matching, also decreases with increasing concentration and, in addition, shows an increase with increasing matrix complexity. While the average SigmaFit value is 0.04, the median is 0.01 indicating some high individual deviations. As with the mass measurement error, the highest deviations are found in those regions of the chromatogram where most compounds elute from the column, be it analytes or matrix compounds. The median repeatability of the method ranges from 8% to 15%, decreasing with increasing concentration, while the median reproducibility ranges from 15% to 20% with little difference between matrices and concentrations. The median accuracy is in between 70% and 100% with a few compounds showing higher values due to matrix interference. The squared regression coefficient is >0.99 for 92% of the compounds showing a good overall linearity for most compounds. The detection capability, CCβ, is within 2 times the associated validation level for >90% of the compounds studied. By changing a few conditions in the analyses protocol and analysing a number of blank samples, it was determined that the method is robust as well as specific. Finally, an alternative validation strategy is proposed and tested for screening methods. While the results calculated for repeatability, within-lab reproducibility and CCβ show a good comparison for the matrices meat and fish, and a reasonable comparison for the matrix egg, only 27 analyses are required to obtain these results versus 63 analysis in the traditional, 2002/657/EC, approach. This alternative is suggested as a cost-effective validation procedure for screening methods.  相似文献   
3.
A simple and rapid method able to determine residues of erythromycin A, tylosin and tilmicosin in whole eggs is presented here. The analytical protocol involves a one-step extraction followed by liquid chromatography (LC)–tandem mass spectrometry. Analytes were extracted from 1 g of egg spiked with an internal standard (josamycin) with acetonitrile. In terms of accuracy, matrix effect and ion signal stability, no extract cleanup was found to be necessary. After partial solvent removal, the final extract was injected into the LC column. Extraction was effective, since absolute recovery of the analyte in egg at their maximum residue limit (MRL) level was 85–102%. Estimated limits of quantification (S/N = 10) were 0.2–0.5 ng/g. Based on the EU Commission Decision 2002/657/EC, the method was in-house validated in terms of ruggedness, specificity, linearity, within-laboratory reproducibility, decision limit (CCα) and detection capability (CCβ). The within-laboratory reproducibility, expressed as RSD (n = 18 at the MRL levels), was not higher than 13%. After validation, a short study on EA depletion in eggs was conducted after administration of this drug to laying hens.  相似文献   
4.
A HPLC method with diode-array detection, at 265 nm, was developed and validated for the determination of ten sulfonamides (SAs): sulfadiazine (SDZ), sulfathiazine (STZ), sulfamethoxine (SMTH), sulfamethizole (SMZ), sulfamethoxypyridazine (SMPZ), sulfamonomethoxine (SMMX), sulfamethoxazole (SMXZ), sulfisoxazole (SIX), sulfadimethoxine (SDMX), and sulfaquinoxaline (SQX) in milk. A mixture of ethyl acetate, n-hexane, and isopropanol was used for the extraction of target analytes from milk. The mobile phase, a mixture of 0.1% v/v formic acid, CH(3) CN, and CH(3) OH was delivered to the analytical column under a gradient program. The procedure was validated according to the European Union regulation 2002/657/EC in terms of selectivity, stability, decision limit, detection capability, accuracy, and precision. Mean recoveries of sulfonamides from milk samples spiked at three concentration levels (0.5×MRL, 1×MRL, and 1.5×MRL) (MRL, maximum residue level) were 93.9-115.9% for SDZ, 97.8-102.9% for STZ, 94.6-107.0% for SMTH, 98.3-111.5% for SMZ, 95.3-108.4% for SMPZ, 97.9-106.0% for SMMX, 97.6-111.3% for SMXZ, 94.3-104.6% for SIX, 96.4-109.1% for SDMX, and 98.2-111.2% for SQX. All RSD values were lower than 8.8%. The decision limits CCa calculated by spiking 20 blank milk samples at MRL (100 μg/kg) ranged from 101.61 to 106.84 μg/kg, whereas the detection capability CCb ranged from 105.64 to 119.01 μg/kg.  相似文献   
5.
An experimental design optimization is reported of an analytical procedure used in the simultaneous determination of seven non-steroidal anti-inflammatory drugs (NSAIDs) in bovine milk by gas chromatography with mass spectrometry detection (GC-MS). This analytical procedure involves a solid-phase microextraction (SPME) step and an aqueous derivatization procedure of the NSAIDs to ethyl esters in bovine milk. The following NSAIDs are studied: ibuprofen (IBP), naproxen (NPX), ketoprofen (KPF), diclofenac (DCF), flufenamic acid (FLF), tolfenamic acid (TLF) and meclofenamic acid (MCL). Three kinds of SPME fibers - polyacrylate (PA), polydimethylsiloxane/divinylbenzene (PDMS/DVB) and polydimethylsiloxane (PDMS) - are compared to identify the most suitable one for the extraction process, on the basis of two steps: to determine the equilibrium time of each fiber and to select the fiber that provides the best figures-of-merit values calculated with three-way PARAFAC-based calibration models at the equilibrium time. The best results were obtained with the PDMS fiber. Subsequently, 8 experimental factors (related to the derivatization reaction and the SPME) were optimized by means of a D-optimal design that involves only 14 rather than 512 experiments in the complete factorial design. The responses used in the design are the sample mode loadings of the PARAFAC decomposition which are related to the quantity of each NSAID that is extracted in the experiment. Owing to the fact that each analyte is unequivocally identified in the PARAFAC decomposition, a calibration model is not needed for each experimental condition. The procedure fulfils the performance requirements for a confirmatory method established in European Commission Decision 2002/657/EC.  相似文献   
6.
7.
An analytical method for the determination of both sulfadiazine (SDZ) and trimethoprim (TMP), and also N4-acetyl-sulfadiazine (AcSDZ), the main metabolite of SDZ, in fish muscle plus skin has been developed and validated. Dapsone was used as internal standard. The method involves extraction of the analytes from fish tissue by pressurized liquid extraction using water as extractant. Sample cleanup was carried out by solid phase extraction using Abselut Nexus cartridges. Target analytes were quantitatively determined by liquid–chromatography mass spectrometry using single ion monitoring. The developed method was validated according to the European Union requirements (decision 2002/657/EC). The limit of detection for SDZ and AcSDZ was 3.0 and 2.5 µg kg?1 for TMP. The limit of quantification (LOQ) was 10 µg kg?1 for SDZ and AcSDZ and 7.5 µg kg?1 for TMP. The recovery experiments carried out included the concentration levels of 0.5, 1 and 1.5 times the MRLs for SDZ and TMP. Concentration levels for AcSDZ were the same as SDZ. The values obtained were higher than 92.0% with coefficient of variation (CV, %) below 8.6%. The precision of the method, calculated as CV (%), ranged from 0.2 to 6.8% and from 0.8 to 8.9% for intra–day and inter–day analysis, respectively. Decision limit (CCα) was calculated as 104.3, 53.7 and 105.3 µg kg?1 for SDZ, TMP and AcSDZ, respectively. Detection capability (CCβ) was calculated as 110.0, 58.8 and 109.7 µg kg?1 for SDZ, TMP and AcSDZ, respectively. “Matrix effect” and “relative matrix effect” were also evaluated. The method was used for the analysis of fish samples purchased from local markets.  相似文献   
8.
The “Galileo Galilei” airport is a civil and military airport quite close to central Pisa. Although the airport brings benefits in terms of tourism and different types of income, the air traffic growth exacerbates the exposition to aircraft noise. This could significantly affect public health. To this day, a small number of studies takes into account the standard indicators of Europe by considering noise emission data for military aircrafts. We estimated the noise impact produced by the airport and we evaluated the related exposed population by using the Integrated Noise Model (INM). The noise power levels of both commercial and military flights have been considered as an input to the model. Predicted levels were validated by means of a noise-monitoring network. A new tracking system (AirNav Radar) that captures Automatic Identification System (AIS) signals emitted by each aircraft has been used to emulate takeoff and landing procedures. This improves the accuracy of the input to the model. We simulated noise maps for present and future scenarios, including those following the application of noise reduction measures. For each situation, we also estimated the exposure of the population and the percentages of highly annoyed and highly sleep disturbed people. We show the utility of AIS data and their specific elaboration to draw up noise abatement measures in order to reduce the noise impact on population and allow the airport development.  相似文献   
9.
A multiresidue method is described for determining six sulfonamides (SAs) (sulfadiazine, sulfathiazole, sulfamethazine, sulfamethoxazole, sulfaquinoxaline and sulfadimethoxine) in liver by a capillary electrophoresis screening method and a liquid chromatography coupled to tandem mass spectrometry confirmatory assay. Samples were prepared by homogenizing the tissue, with sodium hydroxide and acetonitrile. After evaporation, extracts were injected in the capillary electrophoresis system or mass spectrometry system for confirmatory analysis. The detection of analytes was achieved by laser-induced fluorescence in capillary electrophoresis. Procedures were validated according to the European Union regulation 2002/657/EC determining specificity, selectivity and detection capability for screening method and decision limit, detection capability, specificity, selectivity, trueness and precision for confirmation method. The results of validation process demonstrate that the method is suitable for application in Brazilian statutory veterinary drug residue surveillance programs. Capillary electrophoresis was proved to be a fast, robust method with low time and reagents consumption.  相似文献   
10.
A simple and rapid method able to determine residues of seven quinolone antibacterials in whole eggs is presented here. This method is based on the matrix solid-phase dispersion technique with hot water as extractant followed by liquid chromatography–tandem mass spectrometry. After depositing 1.5 g of an egg sample containing the analytes and the analyte surrogate (norfloxacin) on sand (crystobalite), this material was packed into an extraction cell. Quinolones were extracted by flowing 6 mL of water acidified with 50 mmol/L formic acid through the cell heated at 100 °C. After pH adjustment and filtration of the extract, 100 μL of it was injected into the LC column. MS data acquisition was performed in the multiple reaction monitoring mode, selecting two precursor ion to product ion transitions for each target compound. Hot water appeared an efficient extracting medium, since absolute recoveries of the analyte in egg at the level of 20 ng/g were 89–103%. Estimated limits of quantification (S/N = 10) were 0.2–0.6 ng/g. Based on the EU Commission Decision 2002/657/EC, the method was validated in terms of ruggedness, specificity, linearity, within-laboratory reproducibility, decision limit (CCα and detection capability (CCβ). Depending on the particular analyte, CCαs ranged between 0.41 and 2.6 ng/g, while CCβs were 0.64–3.7 ng/g. The method was linear in the 3–30 ng/g range, with typical R2 values higher than 0.97. The within-laboratory reproducibility (n = 21) at 6 ng/g level was in the 9.0–12% range. After validation, a depletion study of enrofloxacin and one of its metabolites, i.e. ciprofloxacin, in eggs was conducted.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号