全文获取类型
收费全文 | 363篇 |
免费 | 20篇 |
国内免费 | 27篇 |
专业分类
化学 | 381篇 |
力学 | 5篇 |
数学 | 10篇 |
物理学 | 14篇 |
出版年
2021年 | 5篇 |
2020年 | 1篇 |
2019年 | 1篇 |
2018年 | 4篇 |
2017年 | 7篇 |
2016年 | 11篇 |
2015年 | 8篇 |
2014年 | 19篇 |
2013年 | 23篇 |
2012年 | 21篇 |
2011年 | 40篇 |
2010年 | 36篇 |
2009年 | 52篇 |
2008年 | 20篇 |
2007年 | 28篇 |
2006年 | 38篇 |
2005年 | 34篇 |
2004年 | 24篇 |
2003年 | 15篇 |
2002年 | 7篇 |
2001年 | 3篇 |
2000年 | 6篇 |
1999年 | 1篇 |
1997年 | 1篇 |
1996年 | 2篇 |
1995年 | 1篇 |
1994年 | 1篇 |
1990年 | 1篇 |
排序方式: 共有410条查询结果,搜索用时 31 毫秒
1.
The dependence of the beam propagation factor (M
2 parameter) with the absorbed pump power in the case of monolithic microchip laser under face-cooled configuration is extensively
studied. Our investigations show that the M
2 parameter is related to the absorbed pump power through two parameters (α and β) whose values depend on the laser material properties and laser configuration. We have shown that one parameter arises due
to the oscillation of higher order modes in the microchip cavity and the other parameter accounts for the spherical aberration
associated with the thermal lens induced by the pump beam. Such dependency of M
2 parameter with the absorbed pump power is experimentally verified for a face-cooled monolithic microchip laser based on Nd3+ -doped GdVO4 crystal and the values of α and β parameters were estimated from the experimentally measured data points. 相似文献
2.
张志让 《数学年刊A辑(中文版)》2006,(2)
如果群 G 的所有真商群都是 FO-群,但是群 G 本身不是 FO-群,则称 G 为外 FO-群,本文将给出外 FO-群完全的结构描述. 相似文献
3.
Jerman S Podgornik A Cankar K Cadet N Skrt M Zel J Raspor P 《Journal of chromatography. A》2005,1065(1):107-113
The availability of sufficient quantities of DNA of adequate quality is crucial in polymerase chain reaction (PCR)-based methods for genetically modified food detection. In this work, the suitability of anion-exchange CIM (Convective Interaction Media; BIA Separations, Ljubljana, Slovenia) monolithic columns for isolation of DNA from food was studied. Maize and its derivates corn meal and thermally pretreated corn meal were chosen as model food. Two commercially available CIM disk columns were tested: DEAE (diethylaminoethyl) and QA (quaternary amine). Preliminary separations were performed with standard solution of salmon DNA at different pH values and different NaCl concentrations in mobile phase. DEAE groups and pH 8 were chosen for further isolations of DNA from a complex matrix-food extract. The quality and quantity of isolated DNA were tested on agarose gel electrophoresis, with UV-scanning spectrophotometry, and by amplification with real-time PCR. DNA isolated in this way was of suitable quality for further PCR analyses. The described method is also applicable for DNA isolation from processed foods with decreased DNA content. Furthermore, it is more effective and less time-consuming in comparison with the existing proposed methods for isolation of DNA from plant-derived foods. 相似文献
4.
苯乙烯(St)为单体,二乙烯基苯(DVB)为交联剂,在致孔剂甲苯和十二醇存在下,直接以Ф4.6×50mm色谱柱管为模具,同时在整个反应过程中通过氩气对反应混合物施加一个恒定的压力,通过原位聚合制备了聚(苯乙烯-二乙烯基苯)(PSD)型整体柱。在聚合过程中对反应混合物施加一定的压力,使制备的整体柱表面光滑无凹痕现象,并且使柱子的两头平整不凹陷,有利于提高柱效。本文对整体柱的孔结构及其对蛋白质的分离性能进行了研究。实验结果表明,整体柱内部含有大量类似渠道的大孔,孔径为2μm~3μm,在流速为5ml/min时,背压为7MPa。而且流速对色谱分离效率的影响小,流速从1ml/min增大到3ml/min时,牛血清白蛋白和溶菌酶这两种蛋白质的总分离效能指标K1的值基本保持不变,保持在3.35左右,说明可以通过提高流速实现蛋白质的快速分离。 相似文献
5.
Summary Polymerisation of bicontinuous microemulsions yields porous monolithic structures with well defined pore sizes that are potentially
suitable for use as stationary phases for capillary electrochromatography (CEC). A variety of pore sizes can be achieved by
altering the composition of the microemulsion, which typically consists of butyl methacrylate (BMA) and ethylene glycol dimethacrylate
(EGDMA) as the polymerisable oil phase. The aqueous phase consists of water, a surfactant (sodium dodecyl sulphate, SDS) and
a co-surfactant (1-propanol). 2-acrylamido-2-methyl-1-propane sulfonic acid (AMPS) is also added to provide charges along
the polymer backbone to allow electroosmotic flow (EOF) to occur. SEM analysis shows that in-situ polymerisation yields a
monolithic structure with a porous topography. Investigations have shown that these monoliths are easy to prepare, robust
and suitable for the separation of phthalates. They generate higher linear velocities than are achieved using the silica based
HPLC packings normally used for CEC. 相似文献
6.
G. J. Dear D. N. Mallett D. M. Higton A. D. Roberts S. A. Bird H. Young R. S. Plumb I. M. Ismail 《Chromatographia》2002,55(3-4):177-184
Summary In this paper we investigate the potential of alkyl-bonded silica monolithic columns for the isolation and identification
of drug-related components in biological fluids. Up to 6 columns have been connected in series to produce a chromatographic
system with up to 40,000 plates. This high-resolution chromatography system has been coupled to both MS and NMR to enable
efficient detection and characterisation of drug-related components in biological fluids. The use of six coupled columns has
been shown to give enhanced resolution over a high quality silica particulate column packed with 3 μm material which exhibits
the same back pressure. The effect of volume and mass load on the performance of monolithic columns for semi-preparative chromatography
of biological fluids has also been investigated. In these studies it was possible to inject up to 100 mL of neat urine with
no loss of chromatographic performance. Furthermore, upon re-testing, the columns showed similar chromatographic performance.
Again several columns were serially connected, producing enhanced resolution in the semi-preparative mode. 相似文献
7.
Two molecular imprinting polymer (MIP) monolithic columns with (S)-(-)-1,1'-bi-2-naphthol and (R)-(+)-5,5',6,6',7,7',8,8'-octahydro-1,1'-bi-2-naphthol as the templating molecules, respectively, have been prepared by in situ polymerization using 4-vinylpyridine and ethylene dimethacrylate as functional monomer and cross-linker, respectively. The columns with good flow-through properties were obtained by changing the molar ratio of the functional monomer and the template molecule. The effects of mobile-phase composition on separation of enantiomers were systematically investigated. The results indicate that hydrophobic interaction in aqueous solution and hydrogen-bonding interaction in ACN between the enantiomers and polymers could play important roles in the retention and resolution. The effects of chromatographic conditions, such as flow rate, column temperature, sample loading, on the enantioseparation were also studied. Further, these two MIP columns show a cross-reactivity. 相似文献
8.
Lämmerhofer M 《Journal of chromatography. A》2005,1068(1):31-57
A review on the advantages, peculiarities, and the potential of enantioselective capillary electrochromatography (CEC) in nonaqueous media is presented. Some fundamentals on CEC with particular focus on enantioselective CEC are discussed. The strategies, concepts, preferentially utilized chiral selectors and column technologies that have been utilized to succeed in highly efficient enantiomer separations by nonaqueous CEC are described thoroughly. 相似文献
9.
Summary A new, rapid, and precise liquid chromatographic method has been developed for simultaneous identification and quantification
of amphetamine,N-methyl-3,4-methylenedioxymetamphetamine,N-ethyl-3,4-methylenedioxymetamphetamine, andN-methyl-1-(3,4-methyl-enedioxyphenyl)-2-butanamine in the presence of other constituents. The compounds were separated on
a monolithic column with a gradient prepared from acetonitrile and 20mm monobasic potassium buffer at a flow rate of 1.5 mL min−1. Quantitation was performed with metoclopramide as internal standard. Use of different flow rates was investigated and enabled
reduction of the separation time from 11 to 3.5 min for seven substances. The method was then applied to ten seized tablets
to identify and quantify their active ingredients. 相似文献
10.
This report describes the determination of paraquat (PQ) in human blood plasma samples by a direct-injection reversed-phase ion-pair chromatographic method. Blood plasma filtrate was injected directly into the LiChrospher® RP-18 alkyl-diol silica (ADS) precolumn integrated in a column switching system using a mixture of 3% 2-propanol and 10 mM sodium octane sulfonate (SOS) in a 0.05 M phosphate buffer (pH 2.8). After washing with this phase, the ADS precolumn was back-flushed with the analytical mobile phase consisting of 40% of methanol and 10 mM SOS in a 0.05 M phosphate buffer (pH 2.8) at a flow rate of 1.0 ml min−1, in order to carry the analyte to a conventional reversed-phase analytical column, where the separation of PQ was achieved and finally detected by UV at 258 nm. The recoveries of PQ from human blood plasma samples ranged between 95.0 and 99.5% at nine different concentrations (from 0.05 to 3.00 μg of PQ ml−1) with coefficients of variation <2.5% (n=3). The precision expressed as relative standard deviation was below 3.5% for between-day and below 4.3% for within-day measurements (n=5). The detection limit (signal-to-noise ratio, S/N>3) was 0.005 μg ml−1 with an injection volume of 200 μl. The proposed method is promising for the identification and quantification of PQ at low concentration levels and is suitable for its analysis in human blood plasma samples from intentional or accidental poisonings cases with a sample throughput of 5 samples per hour. 相似文献