排序方式: 共有57条查询结果,搜索用时 15 毫秒
1.
Based on a new three-dimensional autonomous linear system and designing a specific form of saturated function series and a sign function with two variables of system, which are employed to increase saddle-focus equilibrium points with index 2, a novel multi-scroll chaotic system is proposed and its typical dynamical characteristics including bifurcation diagram, Poincare map, and the stability of equilibrium points are analyzed. The hardware circuit is designed and the experimental results are presented for confirmation. 相似文献
2.
现在诱惑态已被证明是一种可以大大提高量子密钥分发安全性能的现实可行的方法.由于考虑到现实应用中激光器在调制过程中的消光比不能做到100%,以及激光器固有的自发辐射因而使得制备真空态并不是一件容易的事情. 因此本文将对理想情况下准单光子光源量子密钥分发系统应用中的诱惑态结论作了补充和扩展,提出了两个弱光强态的诱惑态方案和一个弱光强诱惑态方案.最后,将“双探测器”的理论应用在准单光子源(HSPS)光源系统中,使系统的安全传输距离可达到2215km,比使用普通探测器的系统增加了约50km. 相似文献
3.
由于电压控制升压变换器的传统平均模型中没有包含开关频率,从而无法分析开关频率的大小对电压控制升压变换器中Hopf分岔的影响. 通过建立电压控制升压变换器的含有开关频率的改进平均模型,分析了开关频率对电压控制升压变换器中Hopf分岔的影响,并设计硬件电路,给出电路试验结果. 研究表明:采用电压控制升压变换器的改进平均模型,可以有效地分析不同开关频率对电压控制升压变换器中Hopf分岔的影响; 随着开关频率的减小,电压控制升压变换器更易于发生Hopf分岔.
关键词:
改进平均模型
电压控制升压变换器
开关频率 相似文献
4.
5.
通过解析求解简单极化激元模型的Pancharatnam相位, 研究了温度、耦合强度、声子与光子频率差、平均光子数等对其演化的影响. 结果表明,Pancharatnam相位随时间振荡,且振荡频率和振荡波形随时间变化,这种变化随着温度升高和耦合强度、声子与光子频率差增加而加大. 系统Pancharatnam相位随时间的演化在平均光子数较小时表现比较有规律,但随着平均光子数的增加,它趋于混沌化.
关键词:
极化激元
Pancharatnam 相位
Mach-Zehnder干涉仪
相干态 相似文献
6.
7.
Period-doubling bifurcation in two-stage power factor correction converters using the method of incremental harmonic balance and Floquet theory 下载免费PDF全文
In this paper, period-doubling bifurcation in a two-stage power factor correction converter is analyzed by using the method of incremental harmonic balance (IHB) and Floquet theory. A two-stage power factor correction converter typically employs a cascade configuration of a pre-regulator boost power factor correction converter with average current mode control to achieve a near unity power factor and a tightly regulated post-regulator DC-DC Buck converter with voltage feedback control to regulate the output voltage. Based on the assumption that the tightly regulated post-regulator DC-DC Buck converter is represented as a constant power sink and some other assumptions, the simplified model of the two-stage power factor correction converter is derived and its approximate periodic solution is calculated by the method of IHB. And then, the stability of the system is investigated by using Floquet theory and the stable boundaries are presented on the selected parameter spaces. Finally, some experimental results are given to confirm the effectiveness of the theoretical analysis. 相似文献
8.
9.
10.