Journal of Thermal Analysis and Calorimetry - Nanofluids are attractive alternatives for the current heat transfer fluids due to their remarkably higher thermal conductivity which leads to the... 相似文献
A simple, precise and accurate method is proposed for rapid determination of trace amounts of hydroxylamine based on the reaction of hydroxylamine with iodate in acidic media. The reaction of neutral red by the produced nitrite ion was used to monitor the reaction spectrophotometrically at 525 nm by a fixed time method. Hydroxylamine in the range of 0.0400-1.200 microg mL(-1) could be determined. The relative standard deviation for 10 determinations of 0.500 microg mL(-1) hydroxylamine was 1.81% and the limit of detection was 0.010 microg mL(-1). The proposed method was applied to the determination of hydroxylamine in water samples with satisfactory results. 相似文献
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anions such as ClO4- and salicylate, but also a Nernstian response with a slope of -59.4 +/- 1.2 mV per decade for iodide ions over a wide concentration range from 1.0 x 10(-2) to 7.5 x 10(-6) M at 25 degrees C. The potentiometric response was independent of the pH of the solution in the pH range of 2 - 8. The electrode could be used for at least 2 months without any considerable divergence in the potential. Good selectivity for iodide ion, a very short response time, simple preparation and relatively long-term stability were the silent characteristics of this electrode. It was successfully used as an indicator electrode in the potentiometric titration of iodide ions, and also in the determination of iodide from seawater samples and drug formulations. 相似文献
Trichloroisocyanuric acid is used as an effective oxidizing agent for the oxidation of 1,3,5-trisubstituted pyrazolines to their corresponding pyrazoles under both heterogeneous and also solvent free conditions with good yields at room temperature. 相似文献
A new method for extraction and analysis of acetone in human urine based on headspace solid phase microextraction using a
mixture of activated carbon and zeolite as sorbents in a PVC matrix coated on a silver wire and its application to the determination
of ketone bodies is described. Unlike commercial fibers, which are coated on fused silica, the coating adheres strongly to
the silver wire and is thermally stable up to 250 °C. After optimization of coating composition and microextraction conditions
the fiber was used for the analysis of acetone in human urine. 相似文献
An efficient synthesis of 3,4-dihydropyrimidin-2-(1H)-one derivatives by one-pot three-component condensation reaction between an alkyl or aryl aldehyde, a 1,3-dicarbonyl compound,
and urea or thiourea in the presence of catalytic amount of bromodimethylsulfonium bromide has been developed. The condensation
product was obtained in excellent yields in refluxing ethanol and easily separated from the reaction mixture and purified. 相似文献
The complex of propyltriphenylphosphonium bromochromate(VI), PrPh3P[CrO3Br] is easily synthesized in nearly quantitative yield using a direct reaction of chromium(VI) oxide and propyltriphenylphosphonium
bromide. This compound is a versatile reagent for the efficient and selective oxidation of organic substrates, in particular
for alcohols to their corresponding aldehydes or ketones, under mild conditions. This compound was characterized by IR, UV/Visible,
13C-n.m.r. and 1H-n.m.r. techniques. It crystallized in the monoclinic form and its crystal and molecular structure have been determined by
X-ray crystallography. 相似文献
Permselective modifier films are very important in preparing highly sensitive electrochemical sensors. In this work, for the first time, the behavior of gold and glassy carbon electrodes coated with biocompatible zein film as a permselective membrane for the electrochemical detection of various compounds has been investigated. For this purpose, several electroactive cationic (methylene blue, brilliant green, and thionine) and anionic (potassium ferricyanide, alizarin red S, and riboflavin-5’-phosphate) compounds have been used as model. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) showed that zein membranes prepared from casting solution containing 1% zein in ethanol/water have porous structures with high nanometric roughness. The capacitance values of electrical double layers of electrodes modified with zein film were very high for hydrophilic ions in comparison with hydrophobic ions. Point of zero charge pH (pHpzc) of zein membrane was 4.8. The results of cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) as well as pHpzc study indicated that zein permselective membrane acts as ion exchanger film for selected cationic compounds with fast electrochemical kinetics responses in aqueous solution (pH=7). This behavior was confirmed by circulating solutions containing model compounds from homemade continuous cell equipped with polyamide membranes modified with zein film.
A novel membrane sensor for selective monitoring of iodide, consisting of a triiodide‐ketoconazole ion pair complex dispersed in a PVC matrix, plasticized with a mixture of 2‐nitrophenyl octyl ether and dioctylphtalate with unique selectivity toward iodide ions, is described. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The optimized membrane demonstrates a near‐Nernstian response for iodide ions over a wide linear range from 1.0 × 10?2 to 1.0 × 10?5 M, at 25 ± 1 °C. The electrode could be used over a wide pH range 3–10 and has the advantages of high selectivity, fast response time and good lifetime (over 4 months). It was successfully used as indicator electrode in potentiometric titrations and direct potentiometric assay of iodide ions. 相似文献