首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   18篇
  免费   0篇
化学   10篇
数学   1篇
物理学   7篇
  2021年   1篇
  2017年   1篇
  2015年   2篇
  2013年   1篇
  2011年   1篇
  2010年   1篇
  2008年   1篇
  2007年   2篇
  2006年   2篇
  2005年   1篇
  2003年   4篇
  2002年   1篇
排序方式: 共有18条查询结果,搜索用时 29 毫秒
1.
International Journal of Theoretical Physics - In this study, the momentum-kick model is used to understand the ridge behaviour in dihadron Δη–Δφ correlations recently...  相似文献   
2.
Homo-apioneplanocin A was efficiently synthesized via stereoselective hydroxymethylation, regio- and chemoselective hydroboration, and chemoselective oxidation as key steps from d-ribose.  相似文献   
3.
A rapid, simple and validated liquid chromatography coupled to tandem mass spectrometric method (LC-MS/MS) for topiramate analysis in human plasma has been applied to pharmacokinetic and bioequivalence studies in 24 healthy male Korean volunteers. The procedure involves a simple liquid extraction of topiramate and prednisone (internal standard) with acetonitrile and separation by HPLC equipped with a Capcell Pak C18 column using acetonitrile-0.1% triethylamine (80:20, v/v) as a mobile phase. Detection was carried out on an API 2000 MS system by multiple reactions monitoring mode. The ionization was optimized using ESI(-) and selectivity was achieved by MS/MS analysis, m/z 338.0 --> 77.5 and m/z 357.1 --> 327.2 for topiramate and prednisone, respectively. The method had a total run time of 2.5 min and showed good linearity over a working range of 20-5000 ng/mL in human plasma with a lower limit of quantification of 20 ng/mL. No metabolic compounds were found to interfere with the analysis. The inter-day and intra-day accuracy were in the ranges of 99.24-116.63 and 93.45-108.68%, respectively, and inter-day and intra-day precisions were below 6.24 and 5.25%, respectively. This method was successfully applied for pharmacokinetic and bioequivalence studies by analysis of blood samples taken up to 96 h after an oral administration of 100 mg of topiramate in 24 healthy Korean volunteers.  相似文献   
4.
We present a relativistic quantum-mechanical treatment of opacity and refractive effects that allows reproduction of observables measured in two-pion Hanbury Brown-Twiss (HBT) interferometry and pion spectra at RHIC. The inferred emission duration is substantial. The results are consistent with the emission of pions from a system that has a restored chiral symmetry.  相似文献   
5.
There is an increase in the usage of engineered metal oxide (TiO2 and ZnO) nanoparticles in commercial sunscreens due to their pleasing esthetics and greater sun protection efficiency. A number of studies have been done concerning the safety of nanoparticles in sunscreen products. In order to do the safety assessment, it is pertinent to develop novel analytical techniques to analyze these nanoparticles in commercial sunscreens. This study is focused on developing analytical techniques that can efficiently determine particle size of metal oxides present in the commercial sunscreens. To isolate the mineral UV filters from the organic matrices, specific procedures such as solvent extraction were identified. In addition, several solvents (hexane, chloroform, dichloromethane, and tetrahydrofuran) have been investigated. The solvent extraction using tetrahydrofuran worked well for all the samples investigated. The isolated nanoparticles were characterized by using several different techniques such as transmission electron microscopy, scanning electron microscopy, dynamic light scattering, differential centrifugal sedimentation, and x-ray diffraction. Elemental analysis mapping studies were performed to obtain individual chemical and morphological identities of the nanoparticles. Results from the electron microscopy techniques were compared against the bulk particle sizing techniques. All of the sunscreen products tested in this study were found to contain nanosized (≤100 nm) metal oxide particles with varied shapes and aspect ratios, and four among the 11 products were showed to have anatase TiO2.  相似文献   
6.
Adsorption and desorption of fullerene on a single layer of graphene grown on SiC(0001) were investigated by photoemission spectroscopy (PES). No significant change in the band structure of graphene was observed after fullerene deposition on the graphene layer under vacuum conditions, and subsequent exposure to the air. After annealing the fullerene layer at 275 °C in a vacuum, complete desorption of fullerene was observed without any resulting damage to the graphene structure. The desorption temperature of fullerene was significantly higher than that of pentacene, indicating that fullerene layers show higher stability than pentacene as protection layers of graphene-based devices.  相似文献   
7.
8.
A sensitive validated liquid chromatography-tandem mass spectrometric method (LC-MS/MS) for gabapentin (GB) in human plasma has been developed and applied to pharmacokinetic (PK) and bioequivalence (BE) studies in human. In a randomized crossover design with a 1-week period, each subject received a 300 mg GB capsule. The procedure involves a simple protein precipitation with acetonitrile and separated by LC with a Gemini C(18) column using acetonitrile-10 mm ammonium acetate (20:80, v/v, pH 3.2) as mobile phase. The GB and internal standard [(S)-(+)-alpha-aminocyclohexanepropionic acid hydrate] were analyzed using an LC-API 2000 MS/MS in multiple reaction monitoring mode. The ionization was optimized using ESI(+) and selectivity was achieved using MS/MS analysis, m/z 172.0 --> 154.0 and m/z 172.0 --> 126.0 for GB and IS, respectively. The assay exhibited good linearity over a working range of 20-5000 ng/mL for GB in human plasma with a lower limit of quantitation of 20 ng/mL. No endogenous compounds were found to interfere with the analysis. The accuracy and precision were shown for concentrations over the standard ranges. This method was successfully applied for the PK and BE studies by analysis of blood samples taken up to 36 h after an oral dose of 300 mg of GB in 24 healthy volunteers.  相似文献   
9.
3,5-Dibromo-2-pyrone underwent facile palladium-catalyzed coupling reactions with various primary and secondary alkyl and aryl amines to furnish a variety of the previously unknown 3-arylamino- and 3-alkylamino-5-bromo-2-pyrones with good to excellent regioselectivity and chemical yields.  相似文献   
10.
Animal cloning technology with somatic cells provides an alternative tool to conventional methods for producing transgenic animals. Gene targeting in animals is made feasible using somatic cells with homologous recombination procedure that is a major technique in embryonic stem cells for knocking-out genes. Homologous recombination events in somatic cells are relatively inefficient as compared to those in ES cells, suggesting the need for establishment of efficient gene targeting system in somatic cells. To investigate the efficiency of positive and negative selection for gene targeting in pig fetal fibroblast cells, pig alpha-1,3-galactosyl transferase (13-GT) gene was used for gene targeting. The neomycin phosphotransferase (Neo(r)) and herpes simplex virus-thymidine kinase (HSV-tk) genes were used as positive and negative selection markers in this experiment. Following transfection with targeting DNA construct, the pig fetal fibroblast cells were selected against resistance of G418 and gancyclovir. In DMEM medium containing 5 to 10% serum, Pig fetal fibroblast cells failed to proliferate during drug selection. Increasing serum concentration to 15% of medium yielded less senescent colonies of pig fetal fibroblast cells following drug selection that allowed enough cell colonies to screen genomic DNA. The frequency of gene targeting in pig fetal fibroblast cells with double drug selection was more than 10-fold efficient compared to that with G418 single selection. Double selection method with Neo' and HSV-tk genes could be useful for gene targeting in somatic cells for production of cloned animals carrying targeted endogenous genes.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号