1.
This article gives an analytical, computational, and experimental treatment of the spatial resolution encoded in unfocused regions of focused ultrasound beams. This topic is important in diagnostic ultrasound since ultrasound array systems are limited to a single transmit focal point per acoustic transmission, hence there is a loss of spatial resolution away from the transmit focus, even with the use of dynamic receive focusing. It is demonstrated that the spatial bandwidth of a Gaussian-apodized beam is approximately constant with depth, which means that there is just as much encoded spatial resolution away from the transmit focus as there is in the focal region. The practical application of this principle is discussed, an algorithm for retrospectively focusing signals from unfocused regions of fixed-focus beams is presented, and a quantitative comparison between the authors' methods and dynamic-receive beamforming is provided.  相似文献   
2.
Experiments by Gittings, Bandyopadhyay and Durian (Europhys. Lett. 65, 414 (2004)) demonstrate that light possesses a higher probability to propagate in the liquid phase of a foam due to total reflection. The authors term this observation photon channelling which we investigate in this article theoretically. We first derive a central relation in the work of Gitting et al. without any free parameters. It links the photon's path-length fraction f in the liquid phase to the liquid fraction ɛ. We then construct two-dimensional Voronoi foams, replace the cell edges by channels to represent the liquid films and simulate photon paths according to the laws of ray optics using transmission and reflection coefficients from Fresnel's formulas. In an exact honeycomb foam, the photons show superdiffusive behavior. It becomes diffusive as soon as disorder is introduced into the foams. The dependence of the diffusion constant on channel width and refractive index is explained by a one-dimensional random-walk model. It contains a photon channelling state that is crucial for the understanding of the numerical results. At the end, we shortly comment on the observation that photon channelling only occurs in a finite range of ɛ.  相似文献   
3.
This paper proposes an efficient array beam-forming method using spatial matched filtering (SMF) for ultrasonic imaging. In the proposed method, ultrasonic waves are transmitted from an array subaperture with fixed transmit focus as in conventional array imaging. At receive, radio frequency echo signals from each receive channel are passed through a spatial matched filter that is constructed based on the system transmit-receive spatial impulse response. The filtered echo signals are then summed without time delays. The filter concentrates and spatially registers the echo energy from each element so that the pulse-echo impulse response of the summed output is focused with acceptably low side lobes. Analytical beam pattern analysis and simulation results using a linear array show that this spatial filtering method can improve lateral resolution and contrast-to-noise ratio as compared with conventional dynamic receive focusing (DRF) methods. Experimental results with a linear array are consistent but point out the need to address additional practical issues. Spatial filtering is equivalent to synthetic aperture methods that dynamically focus on both transmit and receive throughout the field of view. In one common example of phase aberrations, the SMF method was degraded to a degree comparable to conventional DRF methods.  相似文献   
4.
The use of infrared laser-assisted fluorination to release oxygen from milligram quantities of silicates or other oxide mineral grains is a well-established technique. However, relatively few studies have reported the optimisation of this procedure for oxygen-17 isotope measurements. We describe here details of an analytical system using infrared (10 μm) laser-assisted fluorination, in conjunction with a dual inlet mass spectrometer of high resolving power ( approximately 250) to provide (17)O and (18)O oxygen isotope measurements from 0.5-2 mg of silicates or other oxide mineral grains. Respective precisions (1) of typically 0.08 and 0.04 per thousand are obtained for the complete analytical procedure. Departures from the mass-dependent oxygen isotope fractionation line are quantified by Delta(17)O; our precision (1) of such measurements on individual samples is shown to be +/-0.024 per thousand. In turn, this permits the offset between parallel, mass-dependent fractionation lines to be characterised to substantially greater precision than has been possible hitherto. Application of this system to investigate the (17)O versus (18)O relationship for numerous terrestrial whole-rock and mineral samples, of diverse geological origins and age, indicates that the complete data set may be described by a single, mass-dependent fractionation line of slope 0.5244+/- 0.00038 (standard error). Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
5.
Fast atom bombardment, combined with high-energy collision-induced tandem mass spectrometry, has been used to investigate gas-phase metal-ion interactions with captopril, enalaprilat and lisinopril, all angiotensin-converting enzyme inhibitors.Suggestions for the location of metal-binding sites are presented. For captopril, metal binding occurs most likely at both the sulphur and the nitrogen atom. For enalaprilat and lisinopril, binding preferably occurs at the amine nitrogen. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
6.
A maximum-likelihood (ML) strategy for strain estimation is presented as a framework for designing and evaluating bioelasticity imaging systems. Concepts from continuum mechanics, signal analysis, and acoustic scattering are combined to develop a mathematical model of the ultrasonic waveforms used to form strain images. The model includes three-dimensional (3-D) object motion described by affine transformations, Rayleigh scattering from random media, and 3-D system response functions. The likelihood function for these waveforms is derived to express the Fisher information matrix and variance bounds for displacement and strain estimation. The ML estimator is a generalized cross correlator for pre- and post-compression echo waveforms that is realized by waveform warping and filtering prior to cross correlation and peak detection. Experiments involving soft tissuelike media show the ML estimator approaches the Cramer-Rao error bound for small scaling deformations: at 5 MHz and 1.2% compression, the predicted lower bound for displacement errors is 4.4 microns and the measured standard deviation is 5.7 microns.  相似文献   
7.
A method for estimating structural properties of random media is described. The size, number density, and scattering strength of particles are estimated from an analysis of the radio frequency (rf) echo signal power spectrum. Simple correlation functions and the accurate scattering theory of Faran [J.J. Faran, J. Acoust. Soc. Am. 23, 405-418 (1951)], which includes the effects of shear waves, were used separately to model backscatter from spherical particles and thereby describe the structures of the medium. These methods were tested using both glass sphere-in-agar and polystyrene sphere-in-agar scattering media. With the appropriate correlation function, it was possible to measure glass sphere diameters with an accuracy of 20%. It was not possible to accurately estimate the size of polystyrene spheres with the simple spherical and Gaussian correlation models examined because of a significant shear wave contribution. Using the Faran scattering theory for spheres, however, the accuracy for estimating diameters was improved to 10% for both glass and polystyrene scattering media. It was possible to estimate the product of the average scattering particle number density and the average scattering strength per particle, but with lower accuracy than the size estimates. The dependence of the measurement accuracy on the inclusion of shear waves, the wavelength of sound, and medium attenuation are considered, and the implications for describing the structure of biological soft tissues are discussed.  相似文献   
8.
9.
The effects on the radiation response of Harwell polymethylmethacrylate (PMMA) dosimeters of dose-rate, radiation type, temperature during irradiation and post-irradiation storage, and post-irradiation stability, are of importance to the operators of commercial irradiation facilities.

This paper describes recent studies of the effects of some of these parameters on the radiation response of Harwell Red 4034, Amber 3042, and Gammachrome YR Perspex dosimeters, and provides data on batch to batch variation and shelf-life.  相似文献   

10.
A linear array beamforming method for ultrasonic B-mode imaging using spatial matched filtering (SMF) and a rectangular aperture geometry was recently proposed Kim et al., [J. Acoust. Soc. Am. 120, 852-861 (2006)]. This letter extends those results to include circularly symmetric apertures. SMF applied to annular arrays can improve the lateral resolution and echo signal-to-noise ratio as compared with conventional dynamic-receive delay-sum beamforming. At high frequencies, where delay and sum beamforming is problematic, SMF showed greatly improved target contrast over an extended field of view.  相似文献   