首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   67篇
  免费   0篇
化学   53篇
物理学   14篇
  2022年   1篇
  2021年   1篇
  2018年   2篇
  2016年   2篇
  2015年   2篇
  2014年   3篇
  2013年   14篇
  2012年   7篇
  2011年   4篇
  2010年   4篇
  2009年   1篇
  2008年   4篇
  2007年   6篇
  2006年   1篇
  2005年   2篇
  2004年   3篇
  2003年   3篇
  2002年   1篇
  2001年   2篇
  1999年   2篇
  1998年   2篇
排序方式: 共有67条查询结果,搜索用时 17 毫秒
1.
Journal of Applied Spectroscopy - Three simple, sensitive, precise, and rapid spectrophotometric methods are developed and optimized for the assay of vardenafil in pharmaceutical formulations. The...  相似文献   
2.
3.
4.
5.
6.
7.
Doxycycline hyclate (DOX), a broad spectrum antibiotic with activity against a wide range of gram-positive and gram-negative bacteria, is widely used as a pharmacological agent and as an effector molecule in inducible gene expression system. Three simple, selective, rapid, accurate, precise and cost-effective spectrophotometric methods for the determination of DOX in bulk drug and in tablets have been developed and validated. First method (method A) is based on the measurement of absorbance of DOX in 0.1 M HCl at 240 nm. The second method (method B) is based on the measurement of yellow chromogen at 375 nm which is formed in 0.1 M NaOH. The third method is based on the measurement of 2: 1 complex formed between DOX and iron(III) in H2SO4 medium, the complex peaking at 420 nm (method C). The optimum conditions for all the three methods are optimized. Beer’s law was obeyed over the ranges 2.5–50.0, 1.50–30.0 and 10–100 g/mL for method A, method B and method C, respectively. The apparent molar absorptivity values are calculated to be 1.03 × 104, 1.73 × 104, and 5.21 × 103 L mol−1 cm−1 for method A, method B, and method C, respectively. The Sandell sensitivity, limit of detection (LOD) and limit quantification (LOQ) values are also reported. All the methods were validated in accordance with current ICH guidelines. The developed methods were employed with high degree of precision and accuracy for the estimation of total drug content in commercial tablet formulations of DOX.  相似文献   
8.
9.
Two simple, selective and sensitive spectrophotometric methods are described for the determination of pheniramine maleate (PAM) in pure and dosage forms. The method is based on the reaction of PAM with hypochlorite in the presence of Kolthoff buffer (phosphate-borate) of pH 7.0 to form the chloro derivative of PAM, destruction of the excess hypochlorite by nitrite ion (the chloro derivative of drug is unaffected under the optimized conditions) followed by the oxidation of iodide with the chloro derivative of PAM to iodine (I 3 ? which is either measured directly at 355 (method A) or reacted with starch to form a blue chromogen measurable at 590 nm (method B). The optimum conditions that affect the reaction were ascertained, and under these conditions linear relationship was obtained in the concentration ranges of 2–50 and 1–25 μg/mL PAM in methods A and B, respectively. The calculated molar absorptivity values are 7.26 × 103 and 1.28 × 104 L/(mol cm) for method A and method B, respectively. Sandell’s sensitivity values, limits of detection (LOD) and quantification (LOQ) are calculated as per ICH guidelines. The proposed methods were applied successfully to the determination of PAM in tablets and injection with good accuracy and precision and without interferences from common additives. The results obtained by the proposed methods were compared favourably with those of the reference method. The accuracy and reliability of the proposed methods were further checked by recovery studies via standard addition procedure.  相似文献   
10.
Four simple, selective and sensitive methods are described for the determination of levocetirizine dihydrochloride (LCT) in bulk drug and in tablets. The methods exploit the well-known analytical reaction between iodide and iodate in the presence of acid solution. Iodide present is oxidized by iodate in an amount equivalent to the HCl present in LCT to iodine and the liberated iodine is determined by four different procedures which inturn quantify LCT at varying detection range and sensitiveness. Two direct titrimetric procedures involve titration of iodine by thiosulphate either towards starch end point (method A) or potentiometrically (method B). Both the methods have a reaction stiochiometry of 1: 1 (LCT: liberated iodine) and have quantification ranges of 2–20 mg LCT for method A and method B. The liberated iodine is also measured spectrophotometrically at 350 nm (method C) or the iodine-starch complex measured at 570 nm (method D). In both the methods, the absorbance is found to be linearly dependent on the concentration of iodine which in turn is related to LCT concentration. The calibration curves are linear over 5–40 and 1.25–12.5 mg mL?1 LCT for method C and method D, respectively. The calculated molar absorptivity and Sandel sensitivity values are 1.0 × 104 L mol?1 cm?1 and 0.0435 mg cm?2, respectively for method C, and their respective values for method D are 2.9 × 104 L mol?1 cm?1 and 0.0156 mg cm?2. The intra-day and inter-day accuracy and precision studies were carried according to the ICH guidelines. The method was successfully applied to the analysis of two brands of tablets LCT. The accuracy was also checked by placebo blank and synthetic mixture analyses besides recovery study via standard addition procedure.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号