首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   25篇
  免费   0篇
化学   14篇
数学   1篇
物理学   10篇
  2017年   1篇
  2010年   1篇
  2009年   3篇
  2006年   4篇
  2004年   2篇
  2002年   4篇
  2000年   1篇
  1999年   3篇
  1994年   1篇
  1993年   2篇
  1992年   1篇
  1988年   1篇
  1987年   1篇
排序方式: 共有25条查询结果,搜索用时 931 毫秒
1.
2.
Regulating arsenic species in drinking waters is a reasonable objective, since the various species have different toxicological impacts. However, developing robust and sensitive speciation methods is mandatory prior to any such regulations. Numerous arsenic speciation publications exist, but the question of robustness or ruggedness for a regulatory method has not been fully explored. The present work illustrates the use of anion exchange chromatography coupled to ICP-MS with a commercially available "speciation kit" option. The mobile phase containing 2 mM NaH(2)PO(4) and 0.2 mM EDTA at pH 6 allowed adequate separation of four As species (As(III), As(V), MMAA, DMAA) in less than 10 min. The analytical performance characteristics studied, including method detection limits (lower than 100 ng L(-1) for all the species evaluated), proved the suitability of the method to fulfill the current regulation. Other parameters evaluated such as laboratory fortified blanks, spiked recoveries, and reproducibility over a certain period of time produced adequate results. The samples analyzed were taken from water utilities in different areas of the United States and were provided by the U.S. EPA. The data suggests the speciation setup performs to U.S. EPA specifications but sample treatment and chemistry are also important factors for achieving good recoveries for samples spiked with As(III) as arsenite and As(V) as arsenate.  相似文献   
3.
A reversed phase ion-pairing high performance liquid chromatographic (RPIP-HPLC) method is developed for the separation of two phosphorus herbicides, Glufosinate and Glyphosate as well as Aminomethylphosphonic acid (AMPA), the major metabolite of Glyphosate. Tetrabutylammonium hydroxide is used as the ion-pairing reagent in conjunction with an ammonium acetate/acetic acid buffering system at pH 4.7. An inductively coupled plasma mass spectrometer (ICP-MS) is coupled to the chromatographic system to detect the herbicides at m/z = 31P. Historically, phosphorus has been recognized as one of the elements difficult to analyze in argon plasma. This is due to its relatively high ionization potential (10.5 eV) as well as the inherent presence of the polyatomic interferences 14N16O1H+ and 15N16O+ overlapping its only isotope at m/z = 31. An octapole reaction cell is utilized to minimize the isobaric polyatomic interferences and to obtain the highest signal-to-background ratio. Detection limits were found to be in the low ppt range (25-32 ng/l). The developed method is successfully applied to the analysis of water samples collected from the Ohio River and spiked with a standard compounds at a level of 20 microg/l.  相似文献   
4.
High-performance chelation ion chromatography (HPCIC) was employed to retain cationic Cr(III) on an anion-exchange column and hence allow the separation of the two most prevalent forms of chromium, Cr(II) and Cr(VI). A mobile phase of nitric acid was utilized at pH = 1.5; additionally, 2,6-pyridinedicarboxylic acid was used at a concentration of 6 mM. Additives with different structural characteristics were used in an effort to elucidate retention mechanisms. Inductively-coupled plasma mass spectrometry was used for chromium detection. A collision cell was utilized to reduce chloride-based polyatomic ions that may interfere with the detection of Cr(III), and a detection limit study yielded levels in the low part-per-billion range. The newly developed method was applied to the chromatographic analysis of samples of an incubation medium containing Cr(VI) incubated with cell nuclei.  相似文献   
5.
Mass spectrometry continues to tackle many complicated tasks, and ongoing research seeks to simplify its instrumentation as well as sampling. The desorption electrospray ionization (DESI) source was the first ambient ionization source to function without extensive gas requirements and chromatography. Electrospray techniques generally have low efficiency for ionization of nonpolar analytes and some researchers have resorted to methods such as direct analysis in real time (DART) or desorption atmospheric pressure chemical ionization (DAPCI) for their analysis. In this work, a carbon nanotube fiber ionization (nanoCFI) source was developed and was found to be capable of solid phase microextraction (SPME) of nonpolar analytes as well as ionization and sampling similar to that of direct probe atmospheric pressure chemical ionization (DP-APCI). Conductivity and adsorption were maintained by utilizing a corona pin functionalized with a multi-walled carbon nanotube (MWCNT) thread. Quantitative work with the nanoCFI source with a designed corona discharge pin insert demonstrated linearity up to 0.97 (R2) of three target PAHs with phenanthrene internal standard.
Graphical Abstract ?
  相似文献   
6.
Selenoproteins have been identified in a diverse range of organisms, including bacteria and animals. Their occurrence and role in the plant kingdom are, however, less well-understood. This work investigated the water-soluble selenium-containing proteins extracted from a selenium-accumulating plant species (Brassica juncea) and a nonaccumulator species (Helianthus annuus) exposed to varying forms and concentrations of selenium. Firstly, protein extracts were analyzed by size exclusion chromatography coupled to inductively coupled plasma mass spectrometry; specific detection was achieved by monitoring characteristic isotopes. Then, proteolytic digests of the plant extracts were analyzed by reversed phase chromatography coupled to ICP–MS in order to investigate selenoamino acid and selenopeptide content. Selenomethionine was observed to be the primary constituent of the proteins of the nonaccumulator plant, while selenocystine and selenomethionine were found in the same proportion in the accumulator extract. One main selenium-containing species was present at higher levels in the root digests than in the leaf digests; levels were greater in the nonaccumulator than in the accumulator plant.  相似文献   
7.
Determination of an individual's aggregate dietary ingestion of pesticides entails analysis of a difficult sample matrix. Permethrin-specific molecularly imprinted polymer (MIP) solid-phase extraction cartridges were developed for use as a sample preparation technique for a composite food matrix. Vortexing with acetonitrile and centrifugation were found to provide optimal extraction of the permethrin isomers from the composite foods. The acetonitrile (with 1% acetic acid) was mostly evaporated and the analytes reconstituted in 90:10 water/acetonitrile in preparation for molecularly imprinted solid-phase extraction. Permethrin elution was accomplished with acetonitrile and sample extracts were analyzed by isotope dilution gas chromatography–ion trap mass spectrometry. Quantitation of product ions provided definitive identification of the pesticide isomers. The final method parameters were tested with fortified composite food samples of varying fat content (1%, 5%, and 10%) and recoveries ranged from 99.3% to 126%. Vegetable samples with incurred pesticide levels were also analyzed with the given method and recoveries were acceptable (81.0–95.7%). Method detection limits were demonstrated in the low ppb range. Finally, the applicability of the MIP stationary phase to extract other pyrethroids, specifically cyfluthrin and cypermethrin, was also investigated.  相似文献   
8.
Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) has been used to determine the mass of a double-stranded 500 base-pair (bp) polymerase chain reaction (PCR) product with an average theoretical mass of the blunt-ended (i.e. unadenylated) species of 308 859.35 Da. The PCR product was generated from the linearized bacteriophage Lambda genome which is a double-stranded template. Utilization of ethanol precipitation in tandem with a rapid microdialysis step to purify and desalt the PCR product was crucial to obtain a precise mass measurement. The PCR product (0.8 pmol/μL) was electrosprayed from a solution containing 75% acetonitrile, 25 mM piperidine, and 25 mM imidazole and was infused at a rate of 200 nL/min. The average molecular mass and the corresponding precision were determined using the charge-states ranging from 172 to 235 net negative charges. The experimental mass and corresponding precision (reported as the 95% confidence interval of the mean) was 309 406 +/- 27 Da (87 ppm). The mass accuracy was compromised due to the fact that the PCR generates multiple products when using Taq polymerase due to the non-template directed 3'-adenylation. This results in a mixture of three PCR products with nearly identical mass (i.e. blunt-ended, mono-adenylated and di-adenylated) with unknown relative abundances that were not resolved in the spectrum. Thus, the experimental mass will be a weighted average of the three species which, under our experimental conditions, reflects a nearly equal concentration of the mono- and di-adenylated species. This report demonstrates that precise mass measurements of PCR products up to 309 kDa (500 bp) can be routinely obtained by ESI-FTICR requiring low femtomole amounts. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
9.
The potential of chromium to bind to DNA isolated directly from soil microbial communities was investigated in this study. An analytical scheme was developed to distinguish between chromium bound to DNA and its fragments or chromium contained elsewhere in an environmental DNA extract. DNA was extracted from chromium-contaminated soils and purified using DNA clean-up resins. Size-exclusion chromatography was employed due to its advantages in the separation and molecular weight approximation of large biomolecules. It was coupled with two on-line detection systems (spectrophotometric and inductively coupled plasma mass spectrometric) to study the binding of chromium to DNA or other components in a DNA extract. A collision cell was pressurized with helium to remove diatomic and polyatomic interferents resulting from the chosen mobile phase. Chromium peaks were observed in both the large and small molecular weight regions of the chromatogram; to further confirm that the environmentally extracted DNA contained Cr, the subsequently purified DNA was examined for total Cr using flow injection ICP–MS to accommodate small sample volumes. DNA samples isolated from the two soils examined contained 0.5–0.7 ppb Cr, indicating that DNA isolated directly from a chromium-contaminated soil has chromium bound to the nucleic acids.  相似文献   
10.
Polybrominated diphenyl ethers (PBDEs) fall into the class of compounds known as brominated flame retardants and their incorporation in a multitude of products is responsible for saving numerous lives. However, toxicology studies have alerted researchers to the potential adverse health effects that may develop as a result of prolonged or extreme exposure to these compounds. Frequent disposal and subsequent leaching has focused concern on environmental concentrations and current reports cite increasing levels. Method development continues in support of this research and the present work examines the feasibility of utilizing gas chromatography ion trap mass spectrometry operating in positive ion chemical ionization mode. In the evaluation of reagents for chemical ionization (methane, methanol and acetonitrile), comparative results of all three reagents demonstrated more difficult protonation as the number of bromine atoms increased. Methane, possessing the lowest proton affinity, provided the highest response for the analytes. Further, when methane chemical ionization was compared to electron impact ionization, the tetra-congener showed approximately 8× greater sensitivity and the penta- and hexa-congeners demonstrated approximately 2× greater. CI parameters, such as ionization and reaction times, were optimized to provide the highest analyte response and this was followed by the investigation of the employment of MSn. In the this mode, optimal excitation amplitude delivered sufficient fragmentation while maintaining maximum signal, yielding final instrument detection limits in the sub µg L− 1 range.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号