首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   4篇
  2016年   2篇
  2011年   2篇
排序方式: 共有4条查询结果,搜索用时 906 毫秒
1
1.
A simple and rapid method for preconcentration of carbamate insecticides, including methomyl, propoxur, carbofuran, carbaryl, isoprocarb, methiocarb and promecarb, has been developed. It was based on a liquid-liquid microextraction using a [C4MIM][PF6] room temperature ionic liquid as an extraction solvent prior to analysis by high performance liquid chromatography with UV detection. Experimental parameters affecting the extraction performance, such as the volumes of sample, extractant and dissolving solvent, and extraction time, were studied. Under the selected conditions, the enrichment factors in the range between 10 and 25 could be achieved with the limit of detection in the range of 2-40 μg L−1, and with the relative standard deviations of lower than 0.6 and 10.2% for retention time and peak area, respectively. The proposed method offers advantages in reduction of the exposure danger to toxic solvents used in the conventional liquid-liquid extraction, simplicity of the extraction processes, rapidity, and sensitivity enhancement. The method was demonstrated to apply to the analysis of fruit and natural surface water samples.  相似文献   
2.
A technique of ultrasound-assisted low density solvent based dispersive liquid-liquid microextraction was developed for the determination of four phthalate esters, including dimethyl phthalate(DMP), diethyl phthalate(DEP), di-n-butyl phthalate(DnBP) and di(2-ethylhexyl) phthalate(DEHP) in bottled water samples. A low density solvent, toluene, was selected as extraction solvent. In the extraction process, a mixture of 15 μL of toluene(extraction solvent) and 100 μL of methanol(disperser solvent) was rapidly injected into 1.0 mL of water samples. A cloudy solution was formed after ultrasounded for 5 min, and then centrifuged at 5000 r/min for 5 min. The enriched analytes in the floating phase were determined by means of gas chromatograph. Under the optimum conditions, the enrichment factors were found to be in a range of 29-67, and the recoveries were ranged from 81.2% to 103.9%. The limits of the detection were in a range of 3.8-5.6 μg/L. The proposed method was applied to the extraction and determination of phthalate esters in bottled water samples, and the concentrations of phthalate esters found in the water samples were below the allowable levels.  相似文献   
3.
4.
A sequential injection‐bead injection‐lab‐on‐valve system was hyphenated to HPLC for online renewable micro‐solid‐phase extraction of carbamate insecticides. The carbamates studied were isoprocarb, methomyl, carbaryl, carbofuran, methiocarb, promecarb, and propoxur. LiChroprep® RP‐18 beads (25–40 μm) were employed as renewable sorbent packing in a microcolumn situated inside the LOV platform mounted above the multiposition valve of the sequential injection system. The analytes sorbed by the microcolumn were eluted using 80% acetonitrile in 0.1% acetic acid before online introduction to the HPLC system. Separation was performed on an Atlantis C‐18 column (4.6×150 mm, 5 μm) utilizing gradient elution with a flow rate of 1.0 mL/min and a detection wavelength at 270 nm. The sequential injection system offers the means of performing automated handling of sample preconcentration and matrix removal. The enrichment factors ranged between 20 and 125, leading to limits of detection (LODs) in the range of 1–20 μg/L. Good reproducibility was obtained with relative standard deviations of <0.7 and 5.4% for retention time and peak area, respectively. The developed method has been successfully applied to the determination of carbamate residues in fruit, vegetable, and water samples.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号