首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   35篇
  免费   2篇
化学   37篇
  2021年   7篇
  2019年   2篇
  2018年   1篇
  2016年   1篇
  2015年   2篇
  2013年   1篇
  2012年   1篇
  2011年   3篇
  2010年   1篇
  2008年   2篇
  2007年   4篇
  2006年   3篇
  2005年   3篇
  2004年   3篇
  2002年   2篇
  2001年   1篇
排序方式: 共有37条查询结果,搜索用时 15 毫秒
1.
An in‐house flow‐injection capillary electrophoresis with capacitively coupled contactless conductivity detection method was developed for the direct measurement of colistin in pharmaceutical samples. The flow injection and capillary electrophoresis systems are connected by an acrylic interface. Capillary electrophoresis separation is achieved within 2 min using a background electrolyte solution of 5 mM 2‐morpholinoethanesulfonic acid and 5 mM histidine (pH 6). The flow‐injection section allows for convenient filling of the capillary and sample introduction without the use of a pressure/vacuum manifold. Capacitively coupled contactless conductivity detection is employed since colistin has no chromophore but is cationic at pH 6. Calibration curve is linear from 20 to 150 mg/L, with a correlation coefficient (r2) of 0.997. The limit of quantitation is 20 mg/L. The developed method provides precision, simplicity, and short analysis time.  相似文献   
2.
This work presents a simple and innovative protocol employing a microfluidic paper-based analytical device (µPAD) for equipment-free determination of mercury. In this method, mercury (II) forms an ionic-association complex of tetraiodomercurate (II) ion (HgI42−(aq)) using a known excess amount of iodide. The residual iodide flows by capillary action into a second region of the paper where it is converted to iodine by pre-deposited iodate to liberate I2(g) under acidic condition. Iodine vapor diffuses across the spacer region of the µPAD to form a purple colored of tri-iodide starch complex in a detection zone located in a separate layer of the µPAD. The digital image of the complex is analyzed using ImageJ software. The method has a linear calibration range of 50–350 mg L−1 Hg with the detection limit of 20 mg L−1. The method was successfully applied to the determination of mercury in contaminated soil and water samples which the results agreed well with the ICP-MS method. Three soil samples were highly contaminated with mercury above the acceptable WHO limits (0.05 mg kg−1). To the best of our knowledge, this is the first colorimetric µPAD method that is applicable for soil samples including mercury contaminated soils from gold mining areas.  相似文献   
3.
Distribution and mobility of phosphorus in soil and sediment are usually studied by sequential extraction. In the extraction procedure, a sample is treated with a series of reagents to distinguish the phases to which phosphorus is associated such as carbonate and iron or manganese oxides, etc. There have been a number of extraction schemes presented for phosphorus. At present, all of the existing schemes are carried out batchwise. Phosphorus contents derived from all sequences are operationally defined and depend on experimental conditions.An extraction procedure, which is a continuous-flow-based technique, was recently proposed by our group for metals in soils and sediments. The extraction is carried out in a closed chamber through which extractants are passed sequentially. In this paper, the system was investigated using the extraction scheme of Hieltjes and Lijklema to study distribution of phosphorus in three certified reference materials (CRMs). A number of fractions were collected for each reagent for subsequent colorimetric determination. The results are compared with those obtained from a batch extraction. The summation of phosphorus contents of all phases were compared with the certified values and with the values obtained from total digestion. These results have demonstrated that the continuous extraction system developed is also applicable for fractionation of phosphorus. Advantage and disadvantage are discussed.  相似文献   
4.
A simple, sensitive and selective method for the determination of bromide in seawater by using a flow injection/stopped-flow detection technique was examined. The detection system was developed for a new kinetic-spectrophotometric determination of bromide in the presence of chloride matrix without any extraction and/or separation. The detection was based on the kinetic effect of bromide on the oxidation of methylene blue (MB) with hydrogen peroxide in a strongly acidic solution. Large amounts of chloride could enhance the sensitivity of the method as an activator. The decolorisation of the blue color of MB was used for the spectrophotometric determination of bromide at 746 nm. A stopped-flow approach was used to improve the sensitivity of the measurement and provide good linearity of the calibration over the range of 0-3.2 μg ml−1 of bromide. The relative standard deviation was 0.74% for the determination of 2.4 μg ml−1 bromide (n = 5). The detection limit (3σ) was 0.1 μg ml−1 with a sampling frequency of 12 h−1. The influence of potential interfering ions was studied. The proposed method was applied to the determination of bromide in seawater samples and provided satisfactory results.  相似文献   
5.
This work describes development of a flow injection (FI) system for determination of iodide, based on the chemiluminescence (CL) reaction between iodine and luminol. Iodide in the sample zone is oxidized to iodine. Employment of a gas-diffusion (GD) unit allows for selective detection of the generated CL (425 nm). Preliminary results showed for concentrations of less than 2 mg L−1, that signals were irreproducible and that the calibration was not linear.In order to solve these problems, a method of ‘membrane conditioning’ was investigated, in which iodide stream was continuously merged with oxidant to generate I2 that conditioned the GD membrane and tubing. This minimized surface interaction between the active surface and the I2 generated from the samples, thus improving both precision and sensitivity. By employing membrane conditioning, it has been possible to reliably detect concentrations down to 0.1 mg L−1.At the optimized condition, an excellent linear calibration (r2 = 0.999) was obtained from 0.1 to 1.0 mg L−1. The method was successfully applied to determine iodide in some pharmaceutical products such as potassium iodide tablets and a liquid patent medicine. However, for vitamin tablets, ascorbic acid was found to interfere seriously by causing a negative signal.  相似文献   
6.
A simple and rapid method based on micro‐liquid chromatography using a synthetic monolithic capillary column was developed for determination of iohexol in human serums, a marker to evaluate the glomerular filtration rate. A hydrophilic methacrylic acid‐ethylene dimethacrylate monolith provided excellent selectivity and efficiency for iohexol with separation time of 3 min using a mobile phase of 40:60 v/v 50 mM phosphate buffer pH 5/methanol. Four serum protein removal, methods using perchloric acid, 50% acetonitrile, 0.1 M zinc sulfate, and centrifuge membrane filter were examined. The method of zinc sulfate was chosen due to its simplicity, compatibility with the mobile phase system, nontoxicity, and low cost. Interday calibration curves were conducted over iohexol concentrations range of 2–500 mg/L (R2 = 0.9997 ± 0.0001) with detection limit of 0.44 mg/L. Intra‐ and interday precisions for peak area and retention time were less than 2.8 and 1.4%, respectively. The method was successfully applied to serum samples with percent recoveries from 102 to 104. The method was applied to monitor released iohexol from healthy subject. Compared with the commercially available reversed‐phase high‐performance liquid chromatography method, the presented method provided simpler chromatogram, faster separation with higher separation efficiency and much lower sample and solvent consumption.  相似文献   
7.
A reverse flow injection method (rFIA) based on the Winkler titration chemistry, is reported for the determination of dissolved oxygen (DO) in natural waters. Manganese(II) sulfate is injected into a continuously flowing stream of sample and subsequently merges with a reagent stream of sodium hydroxide and sodium iodide. Manganese(II) hydroxide that is formed reacts with DO in the sample to form an oxidized manganese hydroxyoxide floc. Addition of 10% sulfuric acid dissolves this floc, and under acidic conditions, the triiodide ion formed is detected by photometry in a flow through cell at a wavelength of 440 nm. The method is rapid (48 measurements per h), repeatable (R.S.D. ca. 3%, n=3), and has a calculated detection limit of 0.25 mg l−1 (P=0.001). No interference from nitrite or ferrous ions was observed at concentrations typically found in natural waters. The method has been successfully applied to on-line measurement of DO in sediment respiration reactors.  相似文献   
8.
CE methods with capacitively coupled contactless conductivity detection (C4D) were developed for the enantiomeric separation of the following stimulants: amphetamine (AP), methamphetamine (MA), ephedrine (EP), pseudoephedrine (PE), norephedrine (NE) and norpseudoephedrine (NPE). Acetic acid (pH 2.5 and 2.8) was found to be the optimal background electrolyte for the CE‐C4D system. The chiral selectors, carboxymethyl‐β‐cyclodextrin (CMBCD), heptakis(2,6‐di‐O‐methyl)‐β‐cyclodextrin (DMBCD) and chiral crown ether (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid (18C6H4), were investigated for their enantioseparation properties in the BGE. The use of either a single or a combination of two chiral selectors was chosen to obtain optimal condition of enantiomeric selectivity. Enantiomeric separation of AP and MA was achieved using the single chiral selector CMBCD and (hydroxypropyl)methyl cellulose (HPMC) as the modifier. A combination of the two chiral selectors, CMBCD and DMBCD and HPMC as the modifier, was required for enantiomeric separation of EP and PE. In addition, a combination of DMBCD and 18C6H4 was successfully applied for the enantiomeric separation of NE and NPE. The detection limits of the enantiomers were found to be in the range of 2.3–5.7 μmol/L. Good precisions of migration time and peak area were obtained. The developed CE‐C4D method was successfully applied to urine samples of athletes for the identification of enantiomers of the detected stimulants.  相似文献   
9.
In vitro cultures of scarlet flax (Linum grandiflorum L.), an important ornamental flax, have been established as a new possible valuable resource of lignans and neolignans for antioxidant and anti-inflammatory applications. The callogenic potential at different concentrations of α-naphthalene acetic acid (NAA) and thidiazuron (TDZ), alone or in combinations, was evaluated using both L. grandiflorum hypocotyl and cotyledon explants. A higher callus induction frequency was observed on NAA than TDZ, especially for hypocotyl explants, with a maximum frequency (i.e., 95.2%) on 1.0 mg/L of NAA. The presence of NAA (1.0 mg/L) in conjunction with TDZ tended to increase the frequency of callogenesis relative to TDZ alone, but never reached the values observed with NAA alone, thereby indicating the lack of synergy between these two plant growth regulators (PGRs). Similarly, in terms of biomass, NAA was more effective than TDZ, with a maximum accumulation of biomass registered for medium supplemented with 1.0 mg/L of NAA using hypocotyls as initial explants (DW: 13.1 g). However, for biomass, a synergy between the two PGRs was observed, particularly for cotyledon-derived explants and for the lowest concentrations of TDZ. The influence of these two PGRs on callogenesis and biomass is discussed. The HPLC analysis confirmed the presence of lignans (secoisolariciresinol (SECO) and lariciresinol (LARI) and neolignan (dehydrodiconiferyl alcohol [DCA]) naturally accumulated in their glycoside forms. Furthermore, the antioxidant activities performed for both hypocotyl- and cotyledon-derived cultures were also found maximal (DPPH: 89.5%, FRAP 866: µM TEAC, ABTS: 456 µM TEAC) in hypocotyl-derived callus cultures as compared with callus obtained from cotyledon explants. Moreover, the anti-inflammatory activities revealed high inhibition (COX-1: 47.4% and COX-2: 51.1%) for extract of hypocotyl-derived callus cultures at 2.5 mg/L TDZ. The anti-inflammatory action against COX-1 and COX-2 was supported by the IC50 values. This report provides a viable approach for enhanced biomass accumulation and efficient production of (neo)lignans in L. grandiflorum callus cultures.  相似文献   
10.
The electrochemical determination of iodide was studied at boron-doped diamond thin film electrodes (BDD) using cyclic voltammetry (CV) and flow-injection (FI) analysis, with amperometric detection. Cyclic voltammetry of iodide was conducted in a phosphate buffer pH 5. Experiments were performed using glassy carbon (GC) electrode as a comparison. Well-defined oxidation waves of the quasi-reversible cyclic voltammograms were observed at both electrodes. Voltammetric signal-to-background ratios (S/B) were comparable. However, the GC electrode gives much greater in the background current as usual. The potential sweep rate dependence exhibited that the peak current of iodide oxidation at 1 mM varied linearly (r2 = 0.998) with the square root of the scan rate, from 0.01 to 0.30 V s−1. This result indicates that the reaction is a diffusion-controlled process with negligible adsorption on BDD surface, at this iodide concentration. Results of the flow-injection analysis show a highly reproducible amperometric response. The linear working range was observed up to 200 μM (r2 = 0.999). The detection limit, as low as 0.01 μM (3σ of blank), was obtained. This method was successfully applied for quantification of iodide contents in nuclear emergency tablets.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号