首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   25篇
  免费   1篇
化学   21篇
数学   4篇
物理学   1篇
  2022年   2篇
  2021年   1篇
  2019年   1篇
  2015年   1篇
  2014年   1篇
  2013年   4篇
  2012年   5篇
  2011年   6篇
  2009年   1篇
  2003年   1篇
  2002年   2篇
  1985年   1篇
排序方式: 共有26条查询结果,搜索用时 125 毫秒
1.
Rapid detection of trace level anabolic steroids in urine is highly desirable to monitor the consumption of performance enhancing anabolic steroids by athletes. The present article describes a novel strategy for identifying the trace anabolic steroids in urine using Leidenfrost phenomenon assisted thermal desorption (LPTD) coupled to dielectric barrier discharge (DBD) ionization mass spectrometry. Using this method the steroid molecules are enriched within a liquid droplet during the thermal desorption process and desorbed all-together at the last moment of droplet evaporation in a short time domain. The desorbed molecules were ionized using a dielectric barrier discharge ion-source in front of the mass spectrometer inlet at open atmosphere. This process facilitates the sensitivity enhancement with several orders of magnitude compared to the thermal desorption at a lower temperature. The limits of detection (LODs) of various steroid molecules were found to be in the range of 0.05–0.1 ng mL−1 for standard solutions and around two orders of magnitude higher for synthetic urine samples. The detection limits of urinary anabolic steroids could be lowered by using a simple and rapid dichloromethane extraction technique. The analytical figures of merit of this technique were evaluated at open atmosphere using suitable internal standards. The technique is simple and rapid for high sensitivity and high throughput screening of anabolic steroids in urine.  相似文献   
2.
This paper deals with the dielectric barrier discharge (DBD) ion source composed of the outer cylindrical dielectric tube and the inner grounded metallic tube electrode. The sample gas is supplied through the inner ceramic tube. In this ion source, the DBD plasma is localized in the DBD tube so that the sample gases can be ionized just outside of the ceramic tube by the DBD excited helium gas without being exposed in the plasma jet. Besides, ambient air does not take part in the ionization of the sample vapor because ionization takes place inside the DBD ion source. Thus, this method is totally free from contaminants in ambient air. It was found that this ion source is capable of soft, high-sensitivity, and reproducible ionization. Application of this technique to the analysis of methamphetamine, carbaryl and basil leaf was given.  相似文献   
3.
We have examined several combinations of solvents with the aim of optimizing the ionization conditions for molecular diagnosis of malignant tumours by PESI-MS. Although the best conditions may depend on the actual species in the sample, the optimal conditions for renal cell carcinoma (RCC) were achieved by using alcohols. PESI-MS successfully delineated the differential expression of phospholipids (PCs) and triacylglycerols (TAGs) in noncancerous and RCC tissues by using these solvent systems. This study paves the way for the application of PESI-MS in medical samples.  相似文献   
4.
A group of rhenium (I) complexes including in their structure ligands such as CF3SO3‐, CH3CO2‐, CO, 2,2′‐bipyridine, dipyridil[3,2‐a:2′3′‐c]phenazine, naphthalene‐2‐carboxylate, anthracene‐9‐carboxylate, pyrene‐1‐carboxylate and 1,10‐phenanthroline have been studied for the first time by mass spectrometry. The probe electrospray ionization (PESI) is a technique based on electrospray ionization (ESI) that generates electrospray from the tip of a solid metal needle. In this work, mass spectra for organometallic complexes obtained by PESI were compared with those obtained by classical ESI and high flow rate electrospray ionization assisted by corona discharge (HF‐ESI‐CD), an ideal method to avoid decomposition of the complexes and to induce their oxidation to yield intact molecular cation radicals in gas state [M]+. and to produce their reduction yielding the gas species [M]–.. It was found that both techniques showed in general the intact molecular ions of the organometallics studied and provided additional structure characteristic diagnostic fragments. As the rhenium complexes studied in the present work showed strong absorption in the UV–visible region, particularly at 355 nm, laser desorption ionization (LDI) mass spectrometry experiments could be conducted. Although intact molecular ions could be detected in a few cases, LDI mass spectra showed diagnostic fragments for characterization of the complexes structure. Furthermore, matrix‐assisted laser desorption ionization (MALDI) mass spectra were obtained. Nor‐harmane, a compound with basic character, was used as matrix, and the intact molecular ions were detected in two examples, in negative ion mode as the [M]–. species. Results obtained with 2‐[(2E)‐3‐(4‐tert‐buthylphenyl)‐2‐methylprop‐2‐enylidene] malononitrile (DCTB) as matrix are also described. LDI experiments provided more information about the rhenium complex structures than did the MALDI ones. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
5.
The probe electrospray ionization (PESI) is an ESI‐based ionization technique that generates electrospray from the tip of a solid metal needle. In the present work, we describe the PESI mass spectra obtained by in situ measurement of soybeans and several nuts (peanuts, walnuts, cashew nuts, macadamia nuts and almonds) using different solid needles as sampling probes. It was found that PESI‐MS is a valuable approach for in situ lipid analysis of these seeds. The phospholipid and triacylglycerol PESI spectra of different nuts and soybean were compared by principal component analysis (PCA). PCA shows significant differences among the data of each family of seeds. Methanolic extracts of nuts and soybean were exposed to air and sunlight for several days. PESI mass spectra were recorded before and after the treatment. Along the aging of the oil (rancidification), the formation of oxidated species with variable number of hydroperoxide groups could be observed in the PESI spectra. The relative intensity of oxidated triacylglycerols signals increased with days of exposition. Monitoring sensitivity of PESI‐MS was high. This method provides a fast, simple and sensitive technique for the analysis (detection and characterization) of lipids in seed tissue and degree of oxidation of the oil samples. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
6.
Immediate diagnosis of human specimen is an essential prerequisites in medical routines. This study aimed to establish a novel cancer diagnostics system based on probe electrospray ionization-mass spectrometry (PESI-MS) combined with statistical data processing. PESI-MS uses a very fine acupuncture needle as a probe for sampling as well as for ionization. To demonstrate the applicability of PESI-MS for cancer diagnosis, we analyzed nine cases of clear cell renal cell carcinoma (ccRCC) by PESI-MS and processed the data by principal components analysis (PCA). Our system successfully delineated the differences in lipid composition between non-cancerous and cancerous regions. In this case, triacylglycerol (TAG) was reproducibly detected in the cancerous tissue of nine different individuals, the result being consistent with well-known profiles of ccRCC. Moreover, this system enabled us to detect the boundaries of cancerous regions based on the expression of TAG. These results strongly suggest that PESI-MS will be applicable to cancer diagnosis, especially when the number of data is augmented.  相似文献   
7.
A group of rhenium (I) complexes including in their structure ligands such as CF(3)SO(3)-, CH(3)CO(2)-, CO, 2,2'-bipyridine, dipyridil[3,2-a:2'3'-c]phenazine, naphthalene-2-carboxylate, anthracene-9-carboxylate, pyrene-1-carboxylate and 1,10-phenanthroline have been studied for the first time by mass spectrometry. The probe electrospray ionization (PESI) is a technique based on electrospray ionization (ESI) that generates electrospray from the tip of a solid metal needle. In this work, mass spectra for organometallic complexes obtained by PESI were compared with those obtained by classical ESI and high flow rate electrospray ionization assisted by corona discharge (HF-ESI-CD), an ideal method to avoid decomposition of the complexes and to induce their oxidation to yield intact molecular cation radicals in gas state [M](+·) and to produce their reduction yielding the gas species [M](-·). It was found that both techniques showed in general the intact molecular ions of the organometallics studied and provided additional structure characteristic diagnostic fragments. As the rhenium complexes studied in the present work showed strong absorption in the UV-visible region, particularly at 355?nm, laser desorption ionization (LDI) mass spectrometry experiments could be conducted. Although intact molecular ions could be detected in a few cases, LDI mass spectra showed diagnostic fragments for characterization of the complexes structure. Furthermore, matrix-assisted laser desorption ionization (MALDI) mass spectra were obtained. Nor-harmane, a compound with basic character, was used as matrix, and the intact molecular ions were detected in two examples, in negative ion mode as the [M](-·) species. Results obtained with 2-[(2E)-3-(4-tert-buthylphenyl)-2-methylprop-2-enylidene] malononitrile (DCTB) as matrix are also described. LDI experiments provided more information about the rhenium complex structures than did the MALDI ones.  相似文献   
8.
This is a follow-up paper of our previous report on an ion source, which was operated at an operating pressure higher than the atmospheric pressure. Besides having more working gas for desolvation, the reduction of mean free path of electrons in a higher pressure environment increases the threshold voltage for gaseous breakdown, thus enabling a stable electrospray for the sample solution with high surface tension without the occurrence of electric discharge. In our previous work, the ion source was not coupled directly to the mass spectrometer and significant amount of ions were lost before entering the vacuum of the mass spectrometer. In this paper, we report the new design of our second prototype in which, by using a modified ion transport capillary, the pressurized ESI ion source was coupled directly to the first pumping stage of the mass spectrometer without additional modification on the vacuum pumping system. Demonstrations of the new ion source on the sensitive detection of native proteins from aqueous solution in both positive and negative ion modes are presented.  相似文献   
9.

A validated high-performance thin-layer chromatography (HPTLC) method was developed for the simultaneous quantification of oleanolic acid, β-sitosterol and lupeol in the bulb of Urginea indica Kunth. Separation of metabolites was done in mobile phase using toluene‒ethyl acetate‒methanol‒acetone (7:2:0.2:0.2, V/V) and quantification was done after derivatization by dipping in aninsaldehyde‒sulphuric acid; densitometric scan was performed at 530 nm. The proposed method for quantification was linearly calibrated in the range of 200‒1000 ng/spot for oleanolic acid and β-sitosterol; 100‒500 ng/spot for lupeol, and it was found specific and repeatable. The RF values were found at 0.44 ± 0.03, 0.55 ± 0.05 and 0.68 ± 0.08, limit of detection and limit of quantification were 1.045, 0.524, 0.525 µg/spot and 3.167, 1.588, 1.592 µg/spot for oleanolic acid, β-sitosterol and lupeol, respectively. Precision and recovery study for sample and standards were within the limit of the International Council for Harmonization guidelines. Oleanolic acid, β-sitosterol and lupeol were found to be 0.113%, 0.105% and 0.036%, respectively, in methanolic extract of plant on dry weight basis. This study will help in checking routine quality control of herbal drugs as well as herbal formulations containing U. indica.

  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号