A comparative analysis has been made of the amounts of lipids and their fatty-acid compositions in the seeds of the lines of agenetic collection of cotton plants of the speciesGossypium hirsutum and their hybrids and the variety Tashkent-1. The results obtained on the fatty-acid compositions of some hybrids make it possible to recommend the use of individual lines of cotton plants as donors for improving the food-value indices of cottonseed oil.Institute of Chemsitry of Plant Substances, Academy of Sciences of the Uzbek SSR, Tashkent. V. I. Lenin Tashkent State University. Translated from Khimiya Prirodnykh Soedinenii, No. 2, pp. 173–176, March–April, 1991. 相似文献
This study aims to experimentally examine the energy-saving potential by using R-134a filled separated two-phase thermosiphon loop (STPTL) for data center applications. A parametric study had been made to compare the energy consumption of two data center racks. Two fin-and-tube heat exchangers were attached to one of the racks to form two individual thermosiphon loops. The experiments were carried out subject to different operating conditions, including three ambient temperatures (20 °C, 23 °C, and 27 °C) and filling ratios ranging from 30 to 90% in association with heating loads ranging between 1.5 kW and 6 kW. Parametric influences regarding concentrated heat loading or uniform heat loading are studied. It was found that an appreciable energy-savings can be obtained at high filling ratios and a maximum of 49% energy-saving with the assistance of thermosiphon is observed. Accordingly, the rising of system pressure will result in noticeable savings. Relative to the uniform heat loading of the data rack, the thermosiphon shows even more energy-saving potential in concentrated heat loading. This phenomenon is more pronounced at a lower ambient temperature like 20 °C. On the other hand, there is no appreciable energy-saving for the thermosiphon between concentrated and uniform heating loads when the ambient temperature is high (27 °C). Furthermore, the influence of airflow rate was also investigated under various ambient temperatures with a 90% filling ratio and a heating load of 6 kW. The results revealed that the lower airflow rate in the thermosiphon yields comparatively better energy-saving than the higher flow rate. The study on the influence of using two STPTLs indicated that 15–23% energy-saving can be achieved at a 90% filling ratio and 6 kW heating load for all the studied ambient conditions if compared with testing each loop separately. Lower thermal resistance is seen at the higher filling ratios, ambient temperatures, and heating loads.
Let R be a discrete complete valuation ring, with algebraically closedresidue field. Let X be a semi-stable R-curve, with smooth generic fibre. In this paper we study tame coverings of X. 相似文献
Fluorinated amorphous carbon (a-C:F) films e.g. plasma polymerised perfluorocyclobutane have long attracted much consideration due to their low surface energy, hydrophobicity, low refractive index, good electrical and thermal insulation and good thermal stability. Although a-C:F films have many advantages, hydrophobic stability over time in air and water remains a major concern. In this study, the effects of weathering conditions on the hydrophobicity of fluorocarbon films prepared from perfluorocyclobutane precursors were examined using water contact angle measurements. It was found that the high initial hydrophobicity of as-deposited films degrades rapidly in humid conditions. The stability of hydrophobicity can be significantly improved when a suitable treatment such as annealing is employed. The mechanism of weathering was explained with the help of a number of morphological and chemical characterisation techniques such as Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), Fourier Transform Infrared Spectroscopy (FTIR) and X-ray Photoelectron Spectroscopy (XPS). In particular, XPS results demonstrated that a reduction in the overall amount of -CF3 radical, oxygenation of surface fluorides and the formation of an overlayer all influence the degradation of fluorocarbon in aquatic environment. 相似文献