全文获取类型
收费全文 | 352篇 |
免费 | 17篇 |
国内免费 | 1篇 |
专业分类
化学 | 264篇 |
晶体学 | 1篇 |
力学 | 18篇 |
数学 | 46篇 |
物理学 | 41篇 |
出版年
2023年 | 2篇 |
2022年 | 2篇 |
2021年 | 10篇 |
2020年 | 28篇 |
2019年 | 29篇 |
2018年 | 25篇 |
2017年 | 26篇 |
2016年 | 26篇 |
2015年 | 14篇 |
2014年 | 31篇 |
2013年 | 37篇 |
2012年 | 25篇 |
2011年 | 28篇 |
2010年 | 18篇 |
2009年 | 15篇 |
2008年 | 9篇 |
2007年 | 9篇 |
2006年 | 6篇 |
2005年 | 11篇 |
2004年 | 5篇 |
2003年 | 4篇 |
2002年 | 2篇 |
1997年 | 1篇 |
1984年 | 1篇 |
1980年 | 1篇 |
1977年 | 1篇 |
1976年 | 2篇 |
1970年 | 1篇 |
1967年 | 1篇 |
排序方式: 共有370条查询结果,搜索用时 15 毫秒
1.
Leila Torkian Mostafa M. Amini Tayebeh Gorji Omid Sadeghi 《Arabian Journal of Chemistry》2019,12(7):1315-1321
In this study, multiwalled carbon nanotube (MWCNT) was modified by the pyridine group using a silane agent and characterized by infrared spectroscopy (IR), thermal analysis (TG/DTA), and elemental analysis (CHN) and scanning electron microscopy (SEM). The application of this sorbent was investigated in determination of lead ions in aqueous samples, using flame atomic absorption spectrometry (FAAS). Through this study, different parameters such as pH and sample flow rate on adsorption process and eluent concentration, volume and flow rate were optimized. The limit of detection (LOD), the relative standard deviation and the recovery of the method were 2 ng mL?1, 1.3% and 99.7%, respectively. Two standard reference materials (NIST 1571 and NIST 1572) were used to verify accuracy of this method. Finally, the sorbent was successfully applied for extraction and determination of low levels of Pb(II) ions in aqueous samples. 相似文献
2.
Ti(IV) as TiCl3(O3SCF3) and TiO(O2CCF3)2 are used as efficient catalysts for oxidative coupling of aliphatic, aromatic and heteroaromatic thiols to their disulfides in the presence of NaI under air atmosphere. 相似文献
3.
A kinetic spectrophotometric method for determination of trace nitrite in two dynamic ranges (2–100 and 100–500 ng/mL) based on its catalytic effect on the reaction between methylthymol blue and potassium bromate in acidic (sulfuric acid) media is described. The reaction was monitored spectrophotometrically by measuring the decreasing color of methylthymol blue at 437 nm by the fixed‐time method of 4.0 min at 30°C. The detection limit is 0.6 ng/mL, and the relative standard deviations for 50.0 and 250.0 ng/mL nitrite are 1.6% and 1.3%, respectively. The method was used for the determination of nitrite in water samples. 相似文献
4.
Behzad Haghighi Mohammad Reza Hussaindokht Mohammad Reza Bozorgmehr Naser Seyed Matin 《中国化学快报》2007,18(9):1154-1158
In this paper five equations of state are tested for checking their ability to predict the Joule-Thomson inversion curve.These five equations of state are:Mohsennia-Modarres-Mansoori(MMM),Ji-Lemp(JL),modified Soave-Redlich-Kwang(SRK)equation of state by Graboski(MSRK1),modified SRK equation of state by Peneloux and Rauzy(MSRK2),and modified Peng-Robinson (PR)equation of state by Rauzy(PRmr).The investigated equations of state give good prediction of the low-temperature branch of the inversion curve,except for MMM equation of state.The high-temperature branch and the peak of the inversion curve have been observed,in general,to be sensitive to the applied equation of state.The values of the maximum inversion temperature and maximum inversion pressure are calculated for each component used in this work. 相似文献
5.
Behzad Zeynizadeh 《中国化学会会志》2005,52(3):525-530
α,β‐Unsaturated aldehydes and ketones were reduced readily and exclusively to their corresponding allylic alcohols with NaBH4 and catalytic amounts of titanyl acetylacetonate at room temperature. Reduction reactions were carried out in CH3CN or THF. This reducing system was also efficient for the reduction of α‐diketones and acyloins to their corresponding vicinal diols in CH3CN. 相似文献
6.
A simple modification to a commercially available gas chromatograph isotope ratio mass spectrometer (GC/IRMS) allows rapid and precise determination of the stable isotopes ((13)C and (18)O) of CO(2) at ambient CO(2) concentrations. A sample loop was inserted downstream of the GC injection port and used to introduce small volumes of air samples into the GC/IRMS. This procedure does not require a cryofocusing step and significantly reduces the analysis time. The precisions for delta(13)C and delta(18)O of CO(2) at ambient concentration were +/-0.164 and +/-0.247 per thousand, respectively. This modified GC/IRMS was used to test the effects of storage on the (18)O and (13)C isotopic ratios of CO(2) at ambient concentrations in four container types. On average, the change in the (13)C-CO(2) and (18)O-CO(2) ratios of samples after one week of storage in glass vials equipped with butyl rubber stoppers (Bellco Glass Inc.) were depleted by 0.12 and by 0.20 per thousand, respectively. The (13)C ratios in aluminum canisters (Scotty II and IV, Scott Specialty Gasses) after one month of storage were depleted, on average, by 0.73 and 2.04 per thousand, respectively, while the (18)O ratios were depleted by 0.38 and 1.20 per thousand for the Scotty II and IV, respectively. After a month of storage in electropolished containers (Summa canisters, Biospheric Research Corporation), the (13)C-CO(2) and (18)O-CO(2) ratios were depleted, on average, by 0.26 and enriched by 0.30 per thousand, respectively, close to the precision of measurements. Samples were collected at a mature hardwood forest for CO(2) concentration determination and isotopic analysis. A comparison of CO(2) concentrations determined with an infrared gas analyzer and from sample voltages, determined on the GC/IRMS concurrent with the isotopic analysis, indicated that CO(2) concentrations can be determined reliably with the GC/IRMS technique. The (13)C and (18)O ratios of nighttime ecosystem-respired CO(2), determined from the intercept of Keeling plots, were -26.11 per thousand (V-PDB) and -8.81 per thousand (V-PDB-CO(2)), respectively. 相似文献
7.
8.
Saeed Nojavan Tayebeh Gorji Saied Saeed Hosseiny Davarani Amin Morteza-Najarian 《Analytica chimica acta》2014
There are numerous published reports about dispersive liquid phase microextraction of the wide range of substances, however, till now no broadly accepted systematic and purpose oriented selection of extraction solvent has been proposed. Most works deal with the optimization of available solvents without adequate pre-consideration of properness. In this study, it is tried to compare the performances of low- and high-density solvents at the same conditions by means of novel type of extraction vessel with head and bottom conical shape. Extraction efficiencies of seven basic pharmaceutical compounds using eighteen common organic solvents were studied in this work. It was much easier to work with high-density solvents and they mostly showed better performances. This work shows that although exact predicting the performance of the solvents is multifaceted case but the pre-consideration of initial selection of solvents with attention to the physiochemical properties of the desired analytes is feasible and promising. Finally, the practicality of the method for extraction from urine and plasma samples was investigated. 相似文献
9.
Masoud Behzad Karel Samec Sang-In Bak Yacine Kadi Claudio Tenreiro Seung-Woo Hong Jong-Seo Chai 《Journal of Radioanalytical and Nuclear Chemistry》2014,299(2):1001-1006
A worldwide challenge in the near future will be to find a way of producing radioisotopes in sufficient quantity without relying on research reactors. The motivation for this innovative work on targets lies in the accelerator-based production of radioisotopes using a neutron converter target as in the transmutation by adiabatic resonance crossing concept. Thermal analysis of a multi-channel helium cooled device is performed with the computational fluid dynamics code CFX. Different boundary conditions are taken into account in the simulation process and many important parameters such as maximum allowable solid target temperature as well as uniform inlet velocity and outlet pressure changes in the channels are investigated. The results confirm that the cooling configuration works well; hence such a solid target could be operated safely and may be considered for a prototype target. 相似文献
10.
There has been a considerable interest in recent years in developing polymer gel matrices for many important applications such as 2DE for quantization and separation of a variety of proteins and drug delivery system to control the release of active agents. However, a well‐defined knowledge of the ultrastructures of the gels has been elusive. In this study, we report the characterization of two different polymers used in 2DE: Gelatin, a naturally occurring polymer derived from collagen (protein) and agar, a polymer of polysaccharide (sugar) origin. Low‐temperature SEM is used to examine the internal structure of these gels in their frozen natural hydrated states. Results of this study show that both polymers have an array of hollow cells that resembles honeycomb structures. While agar pores are almost circular, the corresponding Gaussian curve is very broad exhibiting a range of radii from nearly 370 to 700 nm. Gelatin pores are smaller and more homogeneous reflecting a narrower distribution from nearly 320 to 650 nm. Overall, these ultrastructural findings could be used to correlate with functions of the polymers. 相似文献