首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   80篇
  免费   3篇
化学   29篇
数学   4篇
物理学   50篇
  2021年   2篇
  2020年   2篇
  2019年   1篇
  2016年   2篇
  2015年   3篇
  2013年   2篇
  2012年   1篇
  2011年   3篇
  2007年   2篇
  2006年   1篇
  2005年   2篇
  2004年   4篇
  2003年   3篇
  2002年   1篇
  2001年   1篇
  2000年   13篇
  1999年   4篇
  1998年   2篇
  1996年   2篇
  1995年   3篇
  1994年   3篇
  1993年   3篇
  1992年   4篇
  1991年   3篇
  1990年   2篇
  1989年   3篇
  1988年   2篇
  1987年   4篇
  1986年   3篇
  1985年   2篇
排序方式: 共有83条查询结果,搜索用时 859 毫秒
1.
Novel mixed valence states have been obtained by the treatment of cobaltous ferrocyanides (Co+2FeII) and ferricyanides (Co+2FeIII) in an ozone flow. The CN stretching bands occur at 2085 cm–1 for Co+2FeII and at 2160 cm–1 for Co+2FeIII. After the ozonization process of Co+2FeII, an intense band approximately at 2125 cm–1 is detected. This intermediate band must correspond to a mixed valence state of the type: FeII–CN–Co2+–NC–FeIII Mössbauer spectra recorded in situ during the ozonization of Co+2FeII show the presence of two components: a doublet with isomer shift and quadrupole splitting values close to the cobalti ferricyanide and a very broad line for the mixed valence state. From the Mössbauer and infrared spectra of the aged samples of the Co+2FeII after ozonization, a relaxation process to the initial state of the samples is observed but the mixed valence state is stable.  相似文献   
2.
3.
4.
5.
6.
7.
The study and extension of a simple automated clean-up method for polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) to a broad range of polychlorinated biphenyls (PCB) is described. The isolation of seven PCDD, ten PCDF, and three coplanar PCB (cPCB) is extended to eight monoortho substituted PCB and seven so-called "marker PCB" (Aroclor 1260) for fatty food samples. This enables quantification of 35 compounds - including all congeners with a WHO toxic equivalent factor (TEF)--in a single extraction and single purification step. The chromatographic behaviour of mono-ortho PCB and marker PCB on a variety of adsorbents, including basic alumina, has been studied. Partitioning of analytes through multi-column sequences is described and correlated with their structural and electronic properties, by use of molecular modelling calculations. The fractionation process available with the Power-Prep automated clean-up system enables rapid independent analysis of the different groups of compounds. Gas chromatography with high resolution mass spectrometry (GC-HRMS) is used for the PCDD/F and cPCB fraction and quadrupole ion-storage tandem in time mass spectrometry (GC-QISTMS) for analysis of the remaining PCB. A comparison study was performed on quality-control samples and real fatty food samples to evaluate the robustness of the new strategy compared with a reference method. On the basis of this simultaneous clean-up, a rapid simplified strategy for PCDD/F and selected PCB analysis determination is proposed for fatty food samples.  相似文献   
8.
Eppe G  Focant JF  Pirard C  Pauw ED 《Talanta》2004,63(5):1135-1146
Recent developments in trapping efficiency inside ion trap mass spectrometer permitted to lower instrument detection limit (IDL). An IDL of 200 fg μl−1 injected with a signal-to-noise ratio of 5:1 for tetrachlorodibenzo-p-dioxin (TCDD) was obtained by gas chromatography coupled to a quadrupole ion storage mass spectrometer in tandem mode (GC/MS/MS). Coupling large volume programmable temperature vaporizer (PTV-LV) injection to GC/MS/MS provides an alternative and complementary method to classical splitless-GC injection connected to high-resolution mass spectrometry (splitless-GC/HRMS) method for dioxin monitoring in food and feed.

An injection volume of 10 μl was found to be the best compromise between the sensitivity requirements and the robustness required for a high throughput method. PTV-LV-GC/MS/MS and Splitless-GC/HRMS were compared by performing analysis on five different matrices such as beef fat, yolk eggs, milk powder, animal feed and serum samples covering a concentration range of two orders of magnitude (i.e. 0.2–25 ng WHO-TEQ kg−1). An analysis of variance (ANOVA) was carried out. Fisher tests pointed out that the method effect for all the 2,3,7,8 congeners was not significant, indicating that the null hypothesis (H0: μ12=…=μn) was not rejected. Moreover, the interaction effects between methods and matrices were not significant for most of the 2,3,7,8 congeners. However, three congeners (2,3,7,8-TCDF; 1,2,3,4,7,8-HxCDD and 1,2,3,4,6,7,8-HpCDD) were characterized by P-values lower than the significance level (=0.05). In toxic equivalence (TEQ), the study showed that no significant bias was observed between the two methods. Consequently, PTV-LV-GC/MS/MS is an attractive technique and can be used as a cost effective complementary method to HRMS for dioxin levels monitoring in food and feed.  相似文献   

9.
Comprehensive two-dimensional gas chromatography with isotope-dilution time-of-flight mass spectrometry (GC × GC-IDTOFMS) was used to measure polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF), and coplanar polychlorinated biphenyl (cPCB) concentrations in ash, sediment, vegetation, and fish samples. The GC × GC capability was achieved by using a quad jet, dual stage, thermal modulator. Zone compression of the GC peaks from modulation resulted in a significant increase of the signal intensity over classical GC-IDTOFMS. The GC × GC column set used an Rtx-Dioxin 2 phase as the first dimension (1D) and an Rtx-500 as the second dimension (2D). The chromatographic separation of the 17 PCDD/Fs and the 4 cPCBs was attained in 1D except for 2,3,7,8-TCDD and CB126 for which deconvoluted ion currents (DIC) were required to be reported separately. The Rtx-500 phase separated the bulk matrix interfering compounds from the target analytes in 2D. The instrumental limit of detection (iLODs) was 0.5 pg for 2,3,7,8-TCDD. The calibration curves showed good correlation coefficients for all the compounds investigated in the concentration range of 0.5–200 pg. GC × GC-IDTOFMS results compared favorably to those from conventional isotope-dilution one-dimensional gas chromatography-high resolution mass spectrometry (GC-IDHRMS). The comprehensive mass analysis of the TOFMS further permitted the identification of other contaminants of concern in the samples.  相似文献   
10.
A comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC x GC-TOF-MS) experimental setup was tested for the measurement of seven 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs), ten 2,3,7,8-substituted polychlorinated dibenzofurans (PCDFs), four non-ortho-polychlorinated biphenyls (PCBs), eight mono-ortho-PCBs, and six indicator PCBs (Aroclor 1260) in foodstuff samples. A 40m RTX-500 (0.18mm I.D., 0.10 microm df) was used as the first dimension (1D) and a 1.5 m BPX-50 (0.10mm I.D., 0.10 microm df) as the second dimension (2D). The GC x GC chromatographic separation was completed in 45 min. Quantification was performed using 13C-label isotope dilution (ID). Isotope ratios of the selected quantification ions were checked against theoretical values prior to peak assignment and quantification. The dynamic working range spanned three orders of magnitude. The lowest detectable amount of 2,3,7,8-TCDD was 0.2 pg. Fish, pork, and milk samples were considered. On a congener basis, the GC x GC-ID-TOF-MS method was compared to the reference GC-ID high resolution mass spectrometry (HRMS) method and to the alternative GC-ID tandem-in-time quadrupole ion storage mass spectrometry (QIST-MS/MS). PCB levels ranged from low picogram (pg) to low nanogram (ng) per gram of sample and data compared very well between the different methods. For all matrices, PCDD/Fs were at a low pg level (0.05-3 pg) on a fresh weight basis. Although congener profiles were accurately described, RSDs of GC x GC-ID-TOF-MS and GC-QIST-MS/MS were much higher than for GC-ID-HRMS, especially for low level pork and milk. On a toxic equivalent (TEQ) basis, all methods, including the dioxin-responsive chemically activated luciferase gene expression (DR-CALUX) assay, produced similar responses. A cost comparison is also presented.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号