首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Measurement of PCDDs, PCDFs, and non-ortho-PCBs by comprehensive two-dimensional gas chromatography-isotope dilution time-of-flight mass spectrometry (GC x GC-IDTOFMS)
Authors:Focant Jean-François  Reiner Eric J  Macpherson Karen  Kolic Terry  Sjödin Andreas  Patterson Donald G  Reese Shawn L  Dorman Frank L  Cochran Jack
Institution:

a Centers for Disease Control and Prevention (CDC), National Center for Environmental Health (NCEH), Division of Laboratory Sciences (DLS), Organic Analytical Toxicology (OAT) Branch, 4770 Buford Hwy NE, Mail Stop F-17, Atlanta, GA 30341, USA

b Ministry of Environment, 125 Resources Road, Toronto, Ont., Canada M9P 3V6

c Folsom Lake College, 100 Clarkesville Road, Folsom, CA 95630, USA

d Restek Corporation, 110 Benner Circle, Bellefonte, PA 16823-8812, USA

e LECO Corporation, 815 Pilot Road, Suite C, Las Vegas, NV 89119, USA

Abstract:Comprehensive two-dimensional gas chromatography with isotope-dilution time-of-flight mass spectrometry (GC × GC-IDTOFMS) was used to measure polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF), and coplanar polychlorinated biphenyl (cPCB) concentrations in ash, sediment, vegetation, and fish samples. The GC × GC capability was achieved by using a quad jet, dual stage, thermal modulator. Zone compression of the GC peaks from modulation resulted in a significant increase of the signal intensity over classical GC-IDTOFMS. The GC × GC column set used an Rtx-Dioxin 2 phase as the first dimension (1D) and an Rtx-500 as the second dimension (2D). The chromatographic separation of the 17 PCDD/Fs and the 4 cPCBs was attained in 1D except for 2,3,7,8-TCDD and CB126 for which deconvoluted ion currents (DIC) were required to be reported separately. The Rtx-500 phase separated the bulk matrix interfering compounds from the target analytes in 2D. The instrumental limit of detection (iLODs) was 0.5 pg for 2,3,7,8-TCDD. The calibration curves showed good correlation coefficients for all the compounds investigated in the concentration range of 0.5–200 pg. GC × GC-IDTOFMS results compared favorably to those from conventional isotope-dilution one-dimensional gas chromatography-high resolution mass spectrometry (GC-IDHRMS). The comprehensive mass analysis of the TOFMS further permitted the identification of other contaminants of concern in the samples.
Keywords:Polychlorinated dibenzo-p-dioxins (PCDDs)  Polychlorinated dibenzofurans (PCDFs)  Coplanar polychlorinated biphenyls (cPCBs)  Comprehensive two-dimensional gas chromatography (GC × GC)  Time-of-flight mass spectrometry (TOFMS)
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号