首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME) was applied for the extraction of six organophosphorous pesticides (OPPs) in water samples. The analytes considered in this study were determined by gas chromatography with mass spectrometry and included prophos, diazinon, chlorpyrifos methyl, methyl parathion, fenchlorphos and chlorpyrifos. Several extraction conditions (extraction solvent and elution/dispersion solvents nature, extraction solvent volume, elution solvent volume, water volume and sample volume) were tested for SPE-DLLME with these analytes and the best results were obtained using carbon tetrachloride as the extraction solvent and acetone as the elution/dispersion solvent. Calibration curves for the determination of OPPs in water samples were constructed in the concentration range of 10-100 ng/L. Limits of detection (LODs) ranged from 38 to 230 pg/L values that are below the maximum admissible level for drinking water (100 ng/L). Relative standard deviations (RSD) were between 8.6 and 10.4% for a fortification level of 100 ng/L. At the same fortification level, the relative recoveries (R.R.) of tap, well and irrigation water samples were in the range of 30.2-97.1%.  相似文献   

2.
Dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography and mass spectrometry (GC-MS) was applied to the determination of six organophosphorous pesticides (OPPs) in water samples. The analytes included in this study were prophos, diazinon, chlorpyrifos methyl, methyl parathion, fenchlorphos and chlorpyrifos. Several extraction and dispersion solvents were tested for dispersive liquid-liquid microextraction of these analytes and the best results were obtained using chloroform as extraction solvent and 2-propanol as dispersion solvent. Calibration curves of the analytes in water samples were constructed in the concentration range from 100 to 1100 ng/L for prophos, diazinon and methyl parathion and in the range from 100 to 1000 ng/L for chlorpyrifos methyl, fenchlorphos and chlorpyrifos. Limits of detection (LODs) were in the range of 1.5-9.1 ng/L and limits of quantification (LOQs) were in the range of 5.1-30.3 ng/L, below the maximum admissible level for drinking water. Relative standard deviations (RSDs) were between 6.5 and 10.1% in the concentration range of 100-1000 ng/L. The relative recoveries (%RRs) of tap, well and irrigation water samples fortified at 800 ng/L were in the range of 46.1-129.4%, with a larger matrix effect being detected in tap water.  相似文献   

3.
A novel method, dispersive liquid-liquid microextraction combined with liquid chromatography-fluorescence detection is proposed for the determination of three beta-blockers (metoprolol, bisoprolol, and betaxolol) in ground water, river water, and bottled mineral water. Some important parameters, such as the kind and volume of extraction and dispersive solvents, extraction time, pH, and salt effect were investigated and optimized. In the method, a suitable mixture of extraction solvent (60 μL carbon tetrachloride) and dispersive solvent (1 mL acetonitrile) were injected into the aqueous samples (5.00 mL) and the cloudy solution was observed. After centrifugation, the enriched analytes in the bottom CCl(4) phase were determined by liquid chromatography with fluorescence detection. Under the optimum conditions, the enrichment factors (EFs) for metoprolol, bisoprolol, and betaxolol were 180, 190, and 182, and the limits of detection (LODs) were 1.8, 1.4, and 1.0 ng L(-1) , respectively. A good linear relationship between the peak area and the concentration of analytes was obtained in the range of 3-150 ng L(-1) . The relative standard deviations (RSDs) for the extraction of 10 ng L(-1) of beta-blockers were in the range of 4.6-5.7% (n = 5). Compared with other methods, dispersive liquid-liquid microextraction is a very simple, rapid, sensitive (low limit of detection), and economical (only 1.06 mL volume of organic solvent) method, which is in compliance with the requirements of green analytical methodologies.  相似文献   

4.
A method was developed for viable and rapid determination of seven polychlorinated biphenyls (PCBs) in water samples with vortex-assisted liquid-liquid microextraction (VALLME) using gas chromatography-mass spectrometry (GC-MS). At first, the most suitable extraction solvent and extraction solvent volume were determined. Later, the parameters affecting the extraction efficiency such as vortex extraction time, rotational speed of the vortex, and ionic strength of the sample were optimized by using a 2(3) factorial experimental design. The optimized extraction conditions for 5 mL water sample were as follows: extractant solvent 200 μL of chloroform; vortex extraction time of 2 min at 3000 rpm; centrifugation 5 min at 4000 rpm, and no ionic strength. Under the optimum condition, limits of detection (LOD) ranged from 0.36 to 0.73 ng/L. Mean recoveries of PCBs from fortified water samples are 96% for three different fortification levels and RSDs of the recoveries are below 5%. The developed procedure was successfully applied to the determination of PCBs in real water and wastewater samples such as tap, well, surface, bottled waters, and municipal, treated municipal, and industrial wastewaters. The performance of the proposed method was compared with traditional liquid-liquid extraction (LLE) of real water samples and the results show that efficiency of proposed method is comparable to the LLE. However, the proposed method offers several advantages, i.e. reducing sample requirement for measurement of target compounds, less solvent consumption, and reducing the costs associated with solvent purchase and waste disposal. It is also viable, rapid, and easy to use for the analyses of PCBs in water samples by using GC-MS.  相似文献   

5.
A novel ultrasound-assisted surfactant-enhanced emulsification microextraction (UASEME) technique has been proposed by using low-density extraction solvents. In the proposed technique, Tween 80 and cyclohexane were injected into 5-mL glass test tubes with conical bottoms, containing 5.00 mL of a water sample that was located inside the ultrasonic bath. When the extraction process was finished, the glass test tube was sealed with a rubber plug and then placed upside down in a centrifuge. The finely dispersed droplets of cyclohexane collected at the conical bottom of test tube because the density of cyclohexane is less than of water, and the PAHs were concentrated in the cyclohexane. Next, 5 μL of the cyclohexane that collected at the conical bottom was removed using a 10-μL microsyringe and injected into high performance liquid chromatography coupled with fluorescence detection (HPLC-FLD) for analysis. The proposed method avoided the use of chlorinated solvents, which have been widely used as extraction solvents in a normal UASEME assay. Parameters that affected the extraction efficiency, such as the type and volume of the extraction solvent, the type and concentration of the surfactant, and the ultrasound emulsification time and salt addition, were investigated and optimised for the method. Under the optimum conditions, the enrichment factors ranged between 90 and 247. The limits of detection of the method were 0.6-62.5 ng L(-1). Good recoveries and repeatability of the method for the eleven PAHs were also obtained. The proposed UASEME technique has been demonstrated to be simple, practical and environmentally friendly for the determination of PAH residues in real water samples.  相似文献   

6.
Dispersive liquid-liquid microextraction and gas chromatography-flame photometric detection (DLLME-GC-FPD) were performed for the speciation of butyl and phenyltin compounds in water samples after derivatization with sodium tetraethylborate (NaBEt4). Some important parameters, such as pH, amount of NaBEt4, derivatization time, kind and volume of extraction and disperser solvents, extraction time and salt effect were investigated and optimized. High enrichment factors (825-1036) and low detection limits (0.2-1 ng L(-1)) were obtained under the optimum conditions. The calibration graphs were linear in the range of 0.5-1000 ng L(-1) (as Sn) for the target analytes. The relative standard deviations (RSDs) for the extraction of 20 ng L(-1) (as Sn) of butyl and phenyltin compounds varied from 2.3 to 5.9% (n=7) and from 4.1 to 8.8% (n=7) with and without using internal standard, respectively. Seawater and river water samples were successfully analyzed using the proposed method and the relative recoveries of the studied compounds in the water samples, at spiking levels of 10.0 and 100 ng L(-1) (as Sn) were obtained to be 82.5-104.7%.  相似文献   

7.
Ionic liquid-based dispersive liquid-liquid microextraction was developed for the extraction and preconcentration of aromatic amine from environmental water. A suitable mixture of extraction solvent (100 μL, 1-butyl-3-methylimidazolium hexafluorophoshate) and dispersive solvent (750 μL, methanol) were injected into the aqueous samples (10.00 mL), forming a cloudy solution. After centrifuging, enriched analytes in the sediment phase were determined by HPLC-UV. The effect of various factors, such as the extraction and dispersive solvent, sample pH, extraction time and salt effect were investigated. Under optimum conditions, enrichment factors for 2-anilinoethanol, o-chloroaniline and 4-bromo-N,N-dimethylaniline were above 50 and the limits of detection (LODs) were 0.023, 0.015 and 0.026 ng/mL, respectively. Their linear ranges were 0.8-400 ng/mL for 2-anilinoethanol, 0.5-200 ng/mL for o-chloroaniline and 0.4-200 ng/mL for 4-bromo-N,N-dimethylaniline, respectively. Relative standard deviations (RSDs) were below 5.0%. The relative recoveries from samples of environmental water were in the range of 82.0-94.0%. Compared with other methods, dispersive liquid-liquid microextraction is simple, rapid, sensitive and economical.  相似文献   

8.
吴翠琴  雷金妹  李韵灵  王韵靓  陈迪云  龚剑 《色谱》2014,32(12):1362-1367
建立了一种基于离子液体的分散液液微萃取技术结合柱前荧光衍生高效液相色谱(IL-DLLME-HPLC-FL)对8种磺胺类药物进行检测的方法,并成功应用于实际环境水样的分析。实验考察了萃取参数对磺胺萃取效率的影响及衍生产物的稳定性。最佳实验条件:以40 μL [C6MIM]PF6]为萃取剂,0.1 mL丙酮为分散剂,对pH=4且不含NaCl的水溶液进行不超声的分散液液微萃取,并衍生化反应6 h。结果表明:在最佳实验条件下,该法在0.2~10 μg/L和10~500 μg/L两个浓度范围内线性良好,线性相关系数r ≥0.9989;检出限为0.08~0.5 μg/L (S/N=3)。对实验室自来水、湖水、珠江水、池塘水分别加标5、50、200 μg/L的回收率为87.2%~101.4%,相对标准偏差为3.7%~6.2%。该法环保、简便,可用于测定实际水样中磺胺类药物。  相似文献   

9.
张建华  黄颖  陈晓秋  陈金花  李辉  陈国南 《色谱》2009,27(6):799-803
建立了简便、快速、有效的分散液-液微萃取-高效液相色谱-荧光检测(DLLME-HPLC-FLD)测定环境水样中15种多环芳烃(PAHs)的方法。重点探讨了萃取剂的种类和用量、分散剂的种类和用量以及萃取时间等对PAHs萃取效率的影响。在优化的条件下,评价了方法的可靠性。15种PAHs在0.01~10 μg/L范围内呈良好的线性关系,相关系数r均不小于0.9913,峰面积的相对标准偏差(RSD)在2.3%~4.7%之间(n=6)。在优化条件下,富集因子和萃取回收率良好,分别为674~1032和67.4%~103.2%,15种PAHs的检出限(S/N=3)在0.0003~0.002 μg/L之间。建立的方法应用于敖江水样中PAHs的检测,平均加标回收率在79.5%~92.3%之间,RSD在4.3%~6.7%范围内(n=5)。该方法适用于环境水样中痕量PAHs的分析。  相似文献   

10.
建立了采用超声辅助分散液液微萃取技术结合高效液相色谱法(UA-DLLME-HPLC)对4种邻苯二甲酸酯(PAEs)进行富集、检测的方法,并成功应用于实际水样分析。实验中采用富集因子来评价萃取效率,考察并优化了影响萃取效率的主要因素,包括萃取剂类型和用量、分散剂类型和用量、超声时间、离子强度、萃取时间和pH值等。结果表明: 在最佳萃取条件下,该法对4种PAEs(邻苯二甲酸二甲酯、邻苯二甲酸二乙酯、邻苯二甲酸二丁酯和邻苯二甲酸二正辛酯)具有较高的富集能力,富集因子分别为71、144、169和159;检出限分别为3.78、1.77、3.07和3.30 μg/L。对实验室自来水、某品牌矿泉水以及湖水分别加标50、200及500 μg/L的回收率为82.99%~114.47%,相对标准偏差为1.93%~8.31%。该法简便、快速、环保,可以用于测定实际水样中的PAEs类增塑剂。  相似文献   

11.
采用分散液相微萃取净化技术,建立了快速测定猪尿中盐酸克伦特罗和氯霉素残留的高效液相色谱-串联质谱分析方法.取5 mL猪尿样品,分别加入5 ngD9-盐酸克伦特罗和D5-氯霉素内标,调节pH至10.0,加入10% NaC1,经250 μL三氯甲烷和750 μL异丙醇分散萃取后离心,转移下层沉淀,氮吹后以甲醇水溶液定容,采...  相似文献   

12.
A dispersive liquid-liquid microextraction (DLLME) procedure coupled with GC/MS detection is described for preconcentration and determination of some organophosphorus and azole group pesticides from water samples. Experimental conditions affecting the DLLME procedure were optimized by means of an experimental design. A mixture of 60 microL chlorobenzene (extraction solvent) and 750 microL acetonitrile (disperser solvent), 3.5 min extraction time, and 7.5 mL aqueous sample volume were chosen for the best recovery by DLLME. The linear range was 1.6-32 microg/L. The LOD ranged from 48.8 to 68.7 ng/L. The RSD values for organophosphorus and azole group pesticides at spiking levels of 3, 6, and 9 microg/L in water samples were in the range of 1.1-12.8%. The applicability and accuracy of the developed method were determined by analysis of spiked water samples, and the recoveries of the analyzed pesticides from artesian, stream, and tap waters at spiking levels of 3, 6, and 9 microg/L were 89.3-105.6, 89.5-103.0, and 92.0-111.3%, respectively.  相似文献   

13.
We describe a method for ionic liquid based dispersive liquid-liquid microextraction of Co(II), Cu(II), Mn(II), Ni(II) and Zn(II), followed by their determination via flow injection inductively coupled plasma optical emission spectrometry. The method is making use of the complexing agent 1-(2-thenoyl)-3,3,3-trifluoracetone, the ionic liquid 1-hexyl-3-methyl imidazolium bis(trifluoromethylsulfonyl)imide, and of ethanol as the dispersing solvent. After extraction and preconcentration, the sedimented ionic liquid (containing the target analytes) is collected, diluted with 1-propanol, and introduced to the ICP-OES. Effects of pH, ionic strength, ligand to metal molar ratio, volumes of extraction and disperser solvents on the performance of the microextraction were optimized in a half-fractional factorial design. The significant parameters were optimized using a face-centered central composite design. The method has detection limits between 0.10 and 0.20?ng?mL?1 of the metal ions, preconcentration factors between 79 and 102, linear responses in 0.25 to 200?ng?mL?1 concentration ranges, and relative standard deviations of 3.4 to 6.0%. The method was successfully applied to the analysis of drinking water, a fish farming pond water, and waste water from an industrial complex.
Figure
Ionic liquid based dispersive liquid-liquid microextraction of Co, Cu, Mn, Ni and Zn followed by determination via flow injection inductively coupled plasma optical emission spectrometry  相似文献   

14.
Dispersive liquid-liquid microextraction (DLLME) and high performance liquid chromatography-diode array detection (HPLC-DAD) was presented for extraction and determination of Irganox 1010, Irganox 1076 and Irgafos 168 (antioxidants) in aqueous samples. Carbon tetrachloride at microliter volume level and acetonitrile were used as extraction and dispersive solvents, respectively. The main advantages of method are high speed, high enrichment factor, high recovery, good repeatability and extraction solvent volume at μL level. Limit of detection for analytes is between 3 and 7 ng mL−1. One variable at a time optimization and response surface modeling were used to obtain optimum conditions for microextraction procedure and nearly same experimental conditions were obtained using both optimization methods. Recoveries in the ranges 78-86% and 84-110% were obtained by one variable at a time and response surface modeling, respectively. Using tap water and packed water as matrices do not show any detrimental effect on the extraction recoveries and enrichment factors of analytes.  相似文献   

15.
付博  张吉苹  周璐  姜晖 《色谱》2017,35(5):533-537
建立了漂浮液滴固化分散液液微萃取(DLLME-SFO)方法,以脂肪酸作为萃取剂,以甲醇作为分散剂,与高效液相色谱联用检测了环境水样中3种烷基苯酚。对影响前处理方法的因素进行了详细考察,在最佳萃取条件(60μL萃取剂辛酸、600μL分散剂甲醇、pH值为2.0~8.0、10 mL水样中加入0.5 g NaCl)下,3种烷基苯酚在20~1 500μg/L范围内具有良好的线性关系,相关系数不小于0.998 5,3种目标化合物的检出限为0.45~0.61μg/L,富集倍数为145~169,实际样品中3个水平的加标回收率为80.1%~109.9%。该方法将脂肪酸作为萃取剂,与HPLC联用实现了烷基苯酚的富集与检测,为环境水样中烷基苯酚的检测提供了对环境友好的前处理新方法。  相似文献   

16.
Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry-selective ion monitoring (GC-MS-SIM) was applied to the determination of methyl tert-butyl ether (MTBE) in water samples. The effect of main parameters affecting the extraction efficiency was studied simultaneously. From selected parameters, volume of extraction solvent, volume of dispersive solvent, and salt concentration were optimized by means of experimental design. The statistical parameters of the derived model were R(2)=0.9987 and F=17.83. The optimal conditions were 42.0 μL for extraction solvent, 0.30 mL for disperser solvent and 5% (w/v) for sodium chloride. The calibration linear range was 0.001-370 μg L(-1). The improved detection limit with the aid of chemometrics was 0.3 ng L(-1). The relative standard deviation (RSD) with n=9 for 0.1 mg L(-1) MTBE in water with and without internal standard was 2.7% and 3.1%, respectively. Under the optimal conditions, the relative recoveries of spiked MTBE in different water samples were in the range of 100-105%.  相似文献   

17.
张吉苹  蒋新娣  黄薇  秦倩  周乔 《色谱》2018,36(5):458-463
建立了基于分子络合的分散液液微萃取(DLLME)方法,以磷酸三丁酯为萃取剂,以甲醇为分散剂,与高效液相色谱联用检测了环境水样中麦草畏和2,4-二氯苯氧乙酸(2,4-D酸)2种苯氧羧酸类除草剂,对影响前处理效果的因素(包括水样的pH值、萃取剂的种类和体积、分散剂的种类和体积、反萃液的pH值、反萃液的体积和盐浓度等)进行了详细考察,在最佳萃取条件下(水样体积10 mL,水样的pH值为0~1.0、100 μL磷酸三丁酯萃取剂、1000 μL甲醇分散剂、0.01 mol/L的氢氧化钾反萃液的体积为80 μL),2种苯氧羧酸类除草剂在0.50~1000 μg/L范围内具有良好的线性,相关系数不小于0.9985,麦草畏和2,4-D酸的检出限分别为0.44 μg/L和0.49 μg/L,富集倍数分别为85和90,在实际样品中的加标回收率为75.7%~104.0%。该方法基于分子络合反应机理,将新型萃取剂磷酸三丁酯应用于分散液液微萃取,与HPLC联用实现了麦草畏和2,4-D酸的富集与检测,为环境水样中苯氧羧酸类除草剂的检测提供了新的前处理方法。  相似文献   

18.
Ultrasound-assisted emulsification microextraction and dispersive liquid-liquid microextraction were compared for extraction of ephedrine, norephedrine, and pseudoephedrine from human urine samples prior to their determination by capillary electrophoresis. Formation of a microemulsion of the organic extract with an aqueous solution (at pH 3.2) containing 10% methanol facilitated the direct injection of the final extract into the capillary. Influential parameters affecting extraction efficiency were systematically studied and optimized. In order to enhance the sensitivity further, field-amplified sample injection was applied. Under optimum extraction and stacking conditions, enrichment factors of up to 140 and 1750 as compared to conventional capillary zone electrophoresis were obtained resulting in limits of detection of 12-33 μg/L and 1.0-2.8 μg/L with dispersive liquid-liquid microextraction and ultrasound-assisted emulsification microextraction when combined with field-amplified sample injection. Calibration graphs showed good linearity for urine samples by both methods with coefficients of determination higher than 0.9973 and percent relative standard deviations of the analyses in the range of 3.4-8.2% for (n = 5). The results showed that the use of ultrasound to assist microextraction provided higher extraction efficiencies than disperser solvents, regarding the hydrophilic nature of the investigated analytes.  相似文献   

19.
Coacervates made of surfactant aggregates, namely aqueous and reverse micelles and vesicles, were firstly used as solvents in single-drop microextraction (SDME) and proposed for the extraction and concentration of chlorophenols prior to liquid chromatography. The formation of coacervate drops in the needle tip of conventional microsyringes depended on the type of intermolecular forces established between the surfactant headgroups making up the supramolecular aggregates; hydrogen bond interactions were strong enough to permit the formation of spherical drops. Stability of 1-50 microL coacervate drops was achieved by introducing the microsyringe needle tip in a PTFE rod, the end of which had been machined out with a heated flanging-tool to get circular flanges (diameters in the range 3.5-6 mm). The parameters affecting the efficiency of single-drop coacervative microextraction (SDCME) were investigated using vesicular coacervates as a solvent and 2-chlorophenol (CP), 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TCP) and pentachlorophenol (PCP) as model analytes. Coacervative microextraction dynamics fit to the general rate equation of liquid-liquid extraction. The effect of variables such as extraction time, drop volume, stirring rate, pH and temperature, on the extraction of chlorophenols was similar to that described for organic solvent drops. Electrolyte concentrations above 0.1 M caused drop instability. Under the optimum conditions, detection limits were in the range 0.1-0.3 microg L(-1). The relative standard deviation was between 4.3 and 5.6 at 20 microg L(-1) spiked level. The method was applied to the determination of the four chlorophenols in wastewater, superficial water from a reservoir and groundwater and the recoveries were in the range 79 and 106% at 5-20 microg L(-1) spiked level.  相似文献   

20.
This work compares two miniaturised sample preparation methods, solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HF-LPME), in combination with gas chromatography coupled to tandem mass spectrometry with a triple quadrupole analyzer for the determination of 77 pesticides in drinking water. In the case of SPME, extraction temperature and time were optimized by experimental design, although other parameters, as desorption time, pH, and ionic strength, were also evaluated. The extraction and desorption solvents [octanol/dihexyl ether (75:25, v/v) and cyclohexane, respectively], as well as the extraction and desorption time, ionic strength, and pH, were studied for the HF-LPME procedure. Under the optimal conditions, recoveries (70.2–113.5% for SPME and 70.0–119.5% for HF-LPME), intra-day precision (2.1–19.4% for SPME and 4.3–22.5% for HF-LPME), inter-day precision (5.2–21.5% for SPME and 8.4–27.3% for HF-LPME), and limits of detection, between 0.1 and 28.8 ng/L for SPME and 0.2 and 47.1 ng/L for HF-LPME and overall uncertainty (9.6–25.2% for SPME and 13.3–27.5% for HF-LPME) were established for both extraction procedures. Finally, the proposed methods were successfully applied to the analysis of 41 drinking water samples, and similar results were obtained with both extraction approaches.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号