首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Different reversed-phase liquid chromatography (LC) columns of conventional dimensions were coupled to an ultraviolet photodiode array detector (UV-DAD) and a magnetic sector-type spectrometer, equipped with an electrospray ionization (ESI) source, by a laboratory-made flow splitter. A mixture of three flavonoid-O-glycosides was employed to examine the effects of the solvent composition, the flow rate, the stationary phase, the pH and the organic acid added, on the chromatographic separation, the UV-DAD detection, the ESI process and the entire LC system with ESI-MS and UV-DAD detection. In the positive ion mode, methanol containing 1% acetic acid was by far the most sensitive in ESI-MS analysis, whereas an acetonitrile/water mobile phase containing 0.5% formic acid was proved to give the best sensitivity in LC/ESI-MS/UV-DAD analysis. In the negative ion mode, the highest sensitivity was obtained with a mobile phase containing 0.1% formic acid, while addition of bases decreased the sensititvity. The optimal flow rate was higher in negative ESI (20-50 micro L/min) than in positive ESI (5 micro L/min), and the percentage of organic phase had an influence on the sensitivity of ESI-MS detection. With regard to the selection of a suitable C(18) reversed-phase LC column, a column which is well end-capped is to be preferred, because residual silanol groups appear to impair the separation of flavonoid glycosides. The optimized LC/ESI-MS/UV-DAD method was applied to a commercial Crataegus extract, which is used in phytomedicine to treat cardiovascular problems and is known to be rich in flavonoids. It is demonstrated how UV spectra and first-order ESI mass spectra allow a fast characterization of flavonoids, even if reference compounds are not available or at hand.  相似文献   

2.
A comparison of different separation methods (high-performance liquid chromatography (HPLC), capillary HPLC (CHPLC) and pressurized capillary electrochromatography (pCEC)) coupled on-line with mass spectrometry (MS) is undertaken using the separation of a crude extract of ergot fungus (secalis cornuti) as an example. New and simple setups for a two-dimensional CHPLC coupled on-line with electrospray ionization (ESI)-MS (2D-CHPLC-MS) as well as for capillary size-exclusion chromatography performed under pCEC conditions and coupled on-line with ESI-MS (CSEC-pCEC-MS) are shown. In addition, an improved method for column packing is presented.  相似文献   

3.
The potential of nonaqueous capillary electrophoresis was investigated for the simultaneous separation of fluoxetine hydrochloride, its meta-isomer, and other related compounds. The resolution of these compounds was compared in aqueous and nonaqueous media. Baseline separation of the studied solutes required a buffer electrolyte solution composed of 25 mM ammonium acetate and 1 M acetic acid in acetonitrile, an applied voltage of 30 kV and a temperature of 20 degrees C. Selectivity was considerably affected by the nature of the solvent (water, methanol, and acetonitrile). Moreover, substituting acetate by formate in the background electrolyte resulted in migration time changes, which were attributed to an ion-pairing phenomenon. Finally, the method was successfully coupled on-line with electrospray ionization-mass spectrometry (ESI-MS) and allowed significant selectivity and sensitivity enhancement. The effect of ESI-MS parameters, such as nebulizing gas pressure, sheath liquid composition and flow rate, on resolution and method sensitivity was also discussed.  相似文献   

4.
This work illustrates the practical use of combined microbore reversed-phase high-performance liquid chromatography (RP-HPLC) with electrospray ionization mass spectrometry (ESI-MS) in protein identification. The approach consisted of the detection of the abnormal beta-globin chain by ESI-MS analysis of mixtures of intact globins, which simultaneously provided their molecular masses. Separation of the polypeptide globin chains was carried out using microbore C4 RP-HPLC on-line with ESI-MS. Direct peptide-mapping ESI-MS without previous chromatographic separation was performed in order to identify tryptic peptides from whole blood. For the sequence confirmation of the abnormal peptide containing the mutation point, C18 RP-HPLC tryptic separation of the globin mixture on-line with collision-induced dissociation (CID) fragmentation was done. The y series ions allowed the identification of the hemoglobin (Hb) variant as [beta134(H12) Val > Ala]. This new Hb was named Hb Mataró, after the city where it was detected.  相似文献   

5.
Reversed-phase chromatography is the most common means of separation for small drug molecules. However, polar drugs may suffer from poor retention and peak shape in reversed-phase high-performance liquid chromatography (RP-HPLC). Hydrophilic interaction liquid chromatography (HILIC) provides a viable alternative to RP-HPLC and is an excellent way to separate polar compounds. This paper describes a HILIC/ESI-MS/MS assay for the determination of acyclovir from rat plasma, amniotic fluid, placental tissue, and fetal tissue. The isocratic separation utilizes an underivatized silica column with an acetonitrile/formate buffer mobile phase (80:20). The method is validated over a range of 50 ng/mL to 50 micro g/mL with % error and % relative standard deviation of <15% over 3 days. All samples are prepared by acetonitrile protein precipitation, which yields high recovery (>84% for acyclovir). This assay can be applied to the pharmacokinetic study of the placental transfer of acyclovir.  相似文献   

6.
Electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) and liquid chromatography coupled with on-line mass spectrometry (LC/MS/MS) were applied to characterize saponins in crude extracts from Panax ginseng. The MS(n) data of the [M - H](-) ions of saponins can provide structural information on the sugar sequences of the saccharide chains and on the sapogins of saponins. By ESI-MS(n), non-isomeric saponins and isomeric saponins with different aglycones can be determined rapidly in plant extracts. LC/MS/MS is a good complementary analytical tool for determination of isomeric saponins. These approaches constitute powerful analytical tools for rapid screening and structural assignment of saponins in plant extracts.  相似文献   

7.
Electrospray ionization tandem mass spectrometry (ESI-MS/MS) and ultraviolet diode array detection (UV-DAD), coupled on-line to reversed phase high performance liquid chromatography (HPLC), was used for the characterization of hydroxyalkyl derivatives of cob(I)alamin. The reduced form of vitamin B12, cob(I)alamin, denoted a supernucleophile due to its high nucleophilic strength, has shown promise as an analytical tool in studies of electrophilically reactive compounds in vitro and in vivo. A method for analysis of DNA-phosphate adducts was developed earlier utilizing the supernucleophilicity of cob(I)alamin to transfer alkyl groups from the phosphotriester configuration in DNA, with the formation of a Co-substituted alkyl-cobalamin (alkyl-Cbl) complex. For the purpose of identification and quantification of alkyl-Cbls at high sensitivity, an MS/MS method has been developed with application to a number of 2-hydroxyalkyl-cobalamins (OHalkyl-Cbls). The precursor oxiranes were reacted with cob(I)alamin, followed by clean-up and mass spectrometric analysis of the resulting OHalkyl-Cbls. It was found that ionization was highly dependent on solvent composition. By using acetonitrile/water/trifluoroacetic acid (TFA) (eluent I), the base peak was the doubly protonated molecule [M + 2H](2+), whereas acetonitrile/water/1-methylpiperidine (eluent II) yielded the singly protonated molecule [M + H](+) as the base peak. Excellent separation was obtained with eluent II, with good separation between stereoisomers, thus enabling the characterization of these by means of UV spectra. Limits of quantitation for 2-hydroxypropyl-cobalamin (OHPr-Cbl) were 0.2 and 2 pg/microL (or 0.1 and 1 fmol/microL) using selected ion recording (SIR) with eluent I and II, respectively. The obtained detection level should be sufficient for analysis of alkyl-Cbls from a wide range of toxicological applications.  相似文献   

8.
A reversed-phase high-performance liquid chromatography/electrospray ionisation mass spectrometry (RP-HPLC/ESI-MS) method was developed and validated for the simultaneous determination of ten major active components in Ginkgo biloba extract (bilobalide, ginkgolides A, B, C, quercetin, kaempferol, isorhamnetin, rutin hydrate, quercetin-3-beta-D-glucoside and quercitrin hydrate) which have not been previously reported to be quantified in a single analysis. The ten components exhibit baseline separation in 50 min by C18 chromatography using a water/1:1 (v/v) methanol/acetonitrile gradient. Quantitation was performed using negative ESI-MS in selected ion monitoring (SIM) mode. Good reproducibility and recovery were obtained by this method. The sensitivity of both UV and different mass spectrometry modes (full scan, selected ion monitoring (SIM), and selected reaction monitoring (SRM)) were compared and both quantitation with and without internal standard were evaluated. The analysis of Ginkgo biloba commercial products showed remarkable variations in the rutin and quercetin content as well as the terpene lactone contents although all the products satisfy the conventional quality control method.  相似文献   

9.
以1-(4-异丙基)苯基-3-甲基-5-吡唑啉酮(PPMP)为衍生化试剂在氨水介质中对壳寡糖链进行衍生化,衍生化产物用RP-HPLC分离和ESI-MS分析。结果表明在确定的衍生化条件下,PPMP和壳寡糖的衍生化产物主要为单分子衍生物,此单分子PPMP衍生物在ESI-MS的正负离子模式下均有较好的响应,并且在RP-HPLC柱上能够实现很好的分离。据此建立了PPMP柱前衍生HPLC/ESI-MS在线联用检测壳寡糖混合物组成的方法。该法可作为壳寡糖样品在质量控制、构效关系研究等方面的方法参考。  相似文献   

10.
This work describes the development and application of an on-line liquid chromatography/mass spectrometry (LC/MS) method using hydrophilic interaction chromatography (HILIC) coupled to negative ion mode electrospray ionisation ion trap mass spectrometry (ESI-MS) for the analysis of highly polar carbohydrate-related metabolites commonly found in plants, ranging from reducing and non-reducing sugars and sugar alcohols to sugar phosphates. Using this method, separation and detection of a mixture of eight authentic standard compounds containing glucose (Glc), sucrose (Suc), raffinose, verbascose, mannitol, maltitol, glucose-6-phosphate (Glc6P) and trehalose-6-phosphate (Tre6P) were achieved in less than 15 min. The method is rapid, robust, selective, and sensitive, with limits of detection (LODs) ranging from 0.2 microM obtained for neutral sugars, to 1.0 microM obtained for sugar alcohols, and 2.0 microM obtained for negatively charged sugar phosphates. We have studied the negative ion collision-induced dissociation (CID) fragmentation behaviour of the non-reducing raffinose family oligosaccharides (RFOs) raffinose, stachyose, and verbascose. Mainly Bi and Ci glycosidic and Ai cross-ring structurally informative cleavages are observed. We have applied this HILIC/ESI-MS method for the analysis of Arabidopsis thaliana wild-type Columbia-0 (Col-0) and its starchless phosphoglucomutase mutant (pgm1) leaf extracts. The method was used to quantify Glc, Suc, raffinose, and Glc6P in A. thaliana extracts. Data obtained using this HILIC/ESI-MS method were compared with those obtained using a comparable porous graphitic carbon-based LC/ESI-MS method.  相似文献   

11.
Synthetic oligonucleotides (ODNs) are routinely analyzed using capillary gel electrophoresis (CGE) for size-sieving based separations as well as electrospray mass spectrometry (ESI-MS) for identification. On-line coupling of these methods is therefore desired in order to combine the analytical capabilities provided by both methods. Performance of on-line CGE-ESI-MS systems is influenced by various parameters, and choice of optimal conditions is crucial for successful coupling experiments. In this study, we explore characteristics of the on-line coupled CGE-ESI-MS system for ODN analysis. Effects of CGE buffer concentration, capillary length, separation and orifice voltage on CGE separation and MS detection of a phosphodiester ODN mixture were examined. Attention was paid to the influence of the interface, such as geometry of capillary alignment, sheath liquid flow-rate and sheath liquid composition on performance of the system.  相似文献   

12.
A reversed-phase high-performance liquid chromatography/electrospray ionisation mass spectrometry (HPLC/ESI-MS) method has been developed to conclusively differentiate the epimers betamethasone and dexamethasone and various esterification products (betamethasone and dexamethasone 21-acetate, betamethasone and dexamethasone 21-phosphate, betamethasone 17-valerate, betamethasone 21-valerate and betamethasone 17,21-dipropionate) in counterfeit drugs. Good separation with baseline resolution of all epimers or isomers was obtained on a Zorbax Eclipse XDB or Luna C8 column, using a step gradient with mobile phases of 0.05 M ammonium acetate and acetonitrile. Betamethasones can also be distinguished by the relative abundance of their m/z 279 ion in the positive electrospray tandem mass spectra. The LC/MS or LC/MS/MS method developed was successfully applied to the analysis of drug product samples, i.e. creams and tablets.  相似文献   

13.
A rapid method for detection and quantification of metabolites of specific olive oil phenolic compounds (hydroxytyrosol monoglucuronide, hydroxytyrosol monosulfate, tyrosol glucuronide, tyrosol sulfate and homovanillic acid sulfate) in low-density lipoprotein (LDL) fractions by solid-phase extraction (SPE) and high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) is described. A 3 microm particle size fast C18 Luna column, 5 cm x 2.0 mm I.D., was used at a flow rate of 0.6 mL/min with a mobile phase consisting of 0.1% (v/v) formic acid (A) and acetonitrile (B). A linear gradient profile was used for separation at column temperature 40 degrees C. The proposed chromatographic procedure is rapid without loosing its separation efficiency and sensitivity. Validation proofs were carried out for the method described, showing a linear system (r>0.99) and a recovery of 81.9 and 101.3% for hydroxytyrosol and homovanillic acid, respectively. The results show that this method is effective and can be used in routine analysis.  相似文献   

14.
Mass spectrometry (MS) is one of the most powerful instrumental techniques for protein analysis. The electrospray ionization (ESI) approach is known to be very gentle and at the same time compatible with liquid separation techniques such as HPLC and CE. However, ESI is known to be susceptible to salts and impurities, which often cause a dramatic decrease in sensitivity due to the suppression of the ionization of the product of interest. For this reason, LC-ESI-MS coupling has so far been largely limited to reversed-phase chromatography with its hydro-organic mobile phases. Other chromatographic techniques are typically "linked" to ESI-MS by time consuming, off-line desalting steps. On-line microdialysis has been proposed as a solution to this dilemma. In this paper, we introduce an improved microdialysis system, which enlarges the number of putative applications, thus allowing chromatographic separations of biological compounds to be directly coupled to MS detection with little to no loss in time or chromatographic resolution. Examples include separations by affinity, ion-exchange and size-exclusion chromatography, all of which were connected successfully to the ESI-MS detector via the on-line microdialyzer. We propose that, using this system, any kind of chromatography technique can be coupled to ESI-MS, thus enabling for example application in quality control or process monitoring of many bioproduction and downstream processes.  相似文献   

15.
Saponins in Platycodi Radix (platycosides) exhibit potent biological activities in mammalian systems, including several beneficial effects such as anti-inflammatory, immunomodulatory and anti-obesity activities. In this study, we developed a new HPLC separation coupled with evaporative light scattering detector (ELSD) for the simultaneous quantitative determination of ten major saponins in Platycodi Radix. Simultaneous separation of these saponins was achieved on a C18 analytical column. The mobile phase consisted of a gradient of aqueous acetonitrile. The method was validated for linearity, precision, accuracy, limit of detection and quantification. Electrospray ionization mass spectrometry (ESI-MS) and liquid chromatography coupled with on-line mass spectrometry (LC-ESI MS/MS) were applied to identify platycosides in the purified fractions and in the crude extract. Under ESI-MS/MS conditions, the fragmentation patterns of [M-H]- ions exclusively show signals corresponding to cleavage of the glycosidic bonds, thus allowing a rapid identification of saponins in the crude extract of Platycodi Radix. The validated HPLC method provides a new basis of overall assessment on quality of Platycodi Radix, and ESI-MS/MS and LC-ESI MS/MS approaches offers analytical tools for a rapid screening of platycosides in the crude extract.  相似文献   

16.
High-flow pneumatically assisted electrospray ionization mass spectrometry (ESI-MS) has been extensively used for the characterization and determination of peptides and peptide hormones available for biomedical research and therapeutic applications. The aim of this study was to optimize a method of characterization and determination of a mixture of peptide hormones with therapeutic interest by liquid chromatography (LC) coupled to ESI-MS. In this work the linear solvation energy relationship methodology was used in order to optimize the mobile phase to be used in the LC separation of the peptide hormone series and the operational parameters of the source and analyzer of ESI were also optimized to obtain the best signal stability and the highest sensitivity. To validate the proposed method for peptide hormone analysis, quality parameters were determined and satisfactory results were obtained. Likewise, the method detection limit was picomole level for most of the peptides employing selected-ion monitoring of the [M+nH]n+ ions.  相似文献   

17.
A method for the quantification of clindamycin in animal plasma using high-performance liquid chromatography combined with electrospray ionization mass spectrometry (LC/ESI-MS/MS) is presented. Lincomycin is used as the internal standard. The sample preparation includes a simple deproteinization step with trichloroacetic acid. Chromatographic separation is achieved on an RP-18 Hypersil column using gradient elution with 0.01 M ammonium acetate and acetonitrile as mobile phase. Good linearity was observed in the range 0-10 microg ml(-1). The limit of quantification of the method is 50 ng ml(-1) and the limit of detection is 1.3 ng ml(-1). The method was shown out to be of use for pharmacokinetic studies of clindamycin formulations in dogs.  相似文献   

18.
A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, which combines on-line sample extraction through turbulent flow chromatography with a monolithic column separation, has been developed for direct injection analysis of drugs and metabolites in human plasma samples. By coupling a monolithic column into the system as the analytical column, the method enables running 'dual-column' extraction and chromatography at higher flow rates, thus significantly reducing the time required for the transfer and mixing of extracted fraction onto the separation column as well as the time for gradient separation. A strategy of assessing and reducing the matrix suppression effect on the on-line extraction LC/MS/MS has also been discussed. Experiments for evaluating the resolution, peak shape, sensitivity, speed, and matrix effect were conducted with dextromethorphan and its metabolite dextrorphan as model compounds in human plasma matrix. It was demonstrated that the total run time for this assay with a baseline separation of two analytes is less than 1.5 min.  相似文献   

19.
A rapid method is presented for the determination of 4 nitroimidazoles in poultry and swine muscle and eggs by liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS). Samples were extracted with acetonitrile, then evaporated the organic phase. After filtration, the extract was directly injected into the LC/ESI-MS/MS system. The LC separation was made on a C8 column by applying a gradient composed of water and acetonitrile. Overall average recoveries ranged from 50-86% for egg, 66-115% for poultry muscle, and 79-111% for swine muscle. The decision limits ranged from 0.05-0.25 microg/kg for egg, 0.07-0.27 microg/kg for poultry muscle, and 0.07-0.26 microg/kg for swine muscle; and detection capabilities ranged from 0.51-0.68 microg/kg for egg, 0.41-0.75 microg/kg for poultry muscle, and 0.53-0.78 microg/kg for swine muscle.  相似文献   

20.
A new method for the simultaneous analysis of some benzoxazolinones, aminophenoxazinones and malonamic acids was developed based on liquid chromatography (LC) coupled to mass spectrometry (MS), using electrospray ionization (ESI) and operating in positive mode. Different ESI-MS parameters, such as fragmentor voltage, capillary voltage, drying gas flow, nebulizer gas pressure and drying gas temperature, were optimized in order to obtain structural information and to achieve maximum sensitivity. Chromatographic separation was performed by a reversed-phase LC column using a linear gradient of water and methanol. Quality assurance of the developed method was assessed by measuring parameters as linearity, sensitivity, repeatability and reproducibility. Quantification method based on the use of internal standard was developed, selecting synthetic 2-methoxy-2H-1,4-benzoxazin-3(4H)-one as internal standard. Good correlations were obtained for all analytes relative to this compound in the range of 0.05-1.5 ng/microL. Instrumental detection limits were between 0.02 and 0.2 ng/microL. Repeatability and reproducibility studies showed acceptable coefficient of variation values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号