首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
In this article, a sensitive cloud point extraction procedure for the preconcentration of trace amounts of palladium, gold and nickel prior to their determination by flame atomic absorption spectrometry has been developed. The cloud point extraction method is based on the complexation of Pd(II), Au(II), and Ni(II) ions with 1-(2-pyridylazo)-2-naphthol and entrapping in non-ionic surfactant Triton X-114. The main factors affecting cloud point extraction efficiency, such as pH of sample solution, concentration of 1-(2-pyridylazo)-2-naphthol and Triton X-114, equilibration temperature and time, were investigated in detail. Under the optimized conditions, calibration curves were constructed for the determination of palladium, gold and nickel according to the general procedure. Linearity was maintained from 0.01 to 1.0 μg/mL for palladium, 10.0 μg/mL to 1.5 μg/mL for gold, and 10.0 μg/mL to 0.5 μg/mL for nickel. Detection limits based on three times the standard deviation of the blank divided by the slope of analytical curve (3Sb/m) for Pd(II), Au(III), and Ni(11) ions were 3.4, 3.9, and 2.4 μg/mL, respectively. Seven replicate determination of a mixture of 0.5 μg/mL palladium and gold and 0.2 μg/mL nickel gave a mean absorbance of 0.174, 0.150, and 0.201 with relative standard deviation ±1.5, ±1.3, and ±1.8%, respectively. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed method has been applied for determination of trace amount of palladium, gold and nickel in certified reference material and water samples with satisfactory results.  相似文献   

2.
The sorption behavior of a newly synthesized silica gel sorbent with thioetheric sites (STS) towards microgram levels of Au(III), Pt(IV) and Pd(II) was studied. Au(III) is quantitatively (>95%) sorbed in the pH region of 1–9. The sorption of Pt(IV) starts at pH 1 and does not exceed 25% in the entire pH region examined. The sorption of Pd(II) starts at pH 7 and reaches 80% at pH 9. The sorption of Au(III) on STS at pH 1 is not affected by milligram amounts of Ni(II), Zn(II), Fe(III), Cu(II), Pb(II), Cd(II) or Co(II). Au(III) is quantitatively eluted with a 5% aqueous solution of thiourea. The adsorption capacity of STS towards Au(III) is 195 mg g−1. The detection limit (DL) of Au(III) (3σ, n = 9) is 25 ng mL−1. The RSD at a level of 10 × DL is about 2%. Solid-phase extraction of trace amounts of Au(III) on the STS sorbent, followed by its flame AAS determination in the eluate was applied to the determination of gold in geological samples. The results obtained for the gold content in the samples were in good agreement with those of the ICP-AES analysis.  相似文献   

3.
p-Toluenesulfonylamide was immobilized on silica gel and on nm-sized silicium dioxide (SiO2). Their adsorption efficiency toward metal ions was investigated by the batch equilibrium technique. Although silica gel and nm-SiO2 have the same composition (silicon and oxygen), the difference in their sizes and surface structures results in distinct chemical activity and selectivity. At pH 4, the adsorption capacity of modified silica gel adsorbent was found to be 4.9, 5.0, 33.2, and 12.6 mg g−1 for Cr(III), Cu(II), Pb(II) and Zn(II), respectively. However, the adsorption capacity of nm-SiO2 adsorbent toward Cr(III) was 26.7 mg g−1 under ultrasonic dispersing. The potential application of p-toluenesulfonylamide-modified silica gel for simultaneous preconcentration of trace chromium, copper, lead and zinc from two standard reference materials and two food samples was performed with satisfactory results. Correspondence: Xijun Chang, Department of Chemistry, Lanzhou University, Lanzhou 730000, P.R. China  相似文献   

4.
A simple and highly selective method was developed for the routine determination of trace or ultratrace amounts of gold and palladium in geological and metallurgical samples. The method uses flow injection on-line preconcentration and separation with determination by flame atomic absorption spectrometry. Au and Pd in the sample are adsorbed on a 2-mercaptopyrimidine chemically modified silica gel (MPMSG) packed microcolumn in a 0.50M HCl medium and then eluted with 0.5 or 1.0% thiourea solution. The eluates are introduced into the flame atomic absorption spectrometer directly. With the use of a 0.85 mL microcolumn (about 0.14 g MPMSG packed), the present system tolerated concentrations of common base metal ions up to 25.0 mg/mL and concentrations of anions up to 100.0 mg/mL when Au(III) at 0.100 microg/mL and Pd(II) at 0.200 microg/mL were preconcentrated for 60 s with a sample flow rate of 5.0 mL/min. The limits of detection were 3.1 ng/mL for Au(III) and 6.1 ng/mL for Pd(II) with relative standard deviations of < or = 2.5%. The analytical results obtained by the proposed method for geological and metallurgical samples were in good agreement with the certified values.  相似文献   

5.
A water-insoluble chelating material, p-dimethylaminobenzylidenerhodanine on silica gel (DMABR—SG) is described for preconcentration of trace amounts of silver(I), gold(III) and palladium(II) from water samples. Radioactive tracers (110mAg and 195Au) were used to study the behavior of silver and gold; palladium was monitored spectrophotometrically as its 1-(2-pyridylazo)naphthol complex in chloroform. In batch experiments, silver was quantitatively retained on the DMABR—SG at acidities ranging from 1.7 M to pH 5, and gold from 3 M to pH 5; equilibrium was achieved within 1 min for both elements. From sea water, silver ion was completely retained at pH 1.0–6.5 and gold ion at pH 1.0–3.5. In the case of palladium, shaking for about 20 min was required for quantitative retention at pH 1.0–5.0 for aqueous solution and at pH 1.0–7.0 for sea water. The chelating capacity of the DMABR—SG was 23 μmol Ag, 11 μmol Au and 11 μmol Pd per g. Quantitative recovery of silver and gold on DMABR—SG columns from sea water was achieved at higher flow rates (1–2 l h-1 and 2–3 l h-1, respectively) than with other chelating resins, e.g., Chelex 100, palladium required slower flow rate (150 ml h-1). Silver retained on the DMABR—SG column was completely eluted with 20 ml of 2.5% sodium thiosulfate solution but palladium remained on the column. Silver, gold and palladium were quantitatively eluted with 20 ml of 0.1% thiourea in 0.1 M hydrochloric acid.  相似文献   

6.
A silica gel based sorbent containing rhodanine as functional group (RDSG) was prepared. Its adsorption and separation characteristics for Ag(I), Au(III) and Pd(II) were studied by flow-injection (FI) on-line preconcentration. Influence of different experimental parameters such as acidity, eluent, co-existing ions were investigated. Trace amounts of Ag, Au and Pd could be efficiently adsorbed by rhodanine-bonded silica gel from acidic solution and eluted with thiourea solution. Common co-existing ions exhibited virtually no interference to the preconcentration and determination. The adsorption capacity of RDSG was 0.0352, 0.107 and 0.122 mmol/g for Ag, Au and Pd, respectively. Detection limits of 0.004, 0.022 and 0.019 μg/mL for Ag, Au and Pd, respectively, were achieved with a sampling time of 60 s at a flow rate of 5.0 mL/min. The relative standard deviation were 0.5%, 0.9% and 1.7% for 0.040 μg/mL Ag, 0.200 μg/mL Au and 0.300 μg/¶mL Pd. The sorption property did not change after 1000 cycles of sorption-desorption. The contents of Ag and Au in three national certified ore samples and Pd in a secondary nickel alloy, an anode slime and a CoCl2 electrolytic solution were determined. The results showed good agreement with the certified values.  相似文献   

7.
The present study was undertaken to develop a novel adsorbent for heavy metal ions, and this paper presents the synthesis and characterization of a composite material-silica gel microspheres encapsulated by salicyclic acid functionalized polystyrene (SG-PS-azo-SA) with a core-shell structure. SG-PS-azo-SA was used to investigate the adsorption of Mn(II), Co(II), Ni(II), Fe(III), Hg(II), Zn(II), Cd(II), Cr(VI), Pd(II), Cu(II), Ag(I), and Au(III) from aqueous solutions. The results revealed that SG-PS-azo-SA has better adsorption capacity for Cu(II), Ag(I) and Au(III). Langmuir and Freundlich isotherm models were applied to analyze the experimental data, the best interpretation for the experimental data was given by the Langmuir isotherm equation with the maximum adsorption capacity for Cu(II), Ag(I), and Au(III) at 1.288 mmol g−1, 1.850 mmol g−1 and 1.613 mmol gt-1, respectively. Thus, silica gel encapsulated by salicyclic acid functionalized polystyrene (SG-PS-azo-SA) is favorable and useful for the removal of Cu(II), Ag(I) and Au(III) metal ions.  相似文献   

8.
Silica gel was firstly functionalised with aminopropyltrimethoxysilane obtaining the aminopropylsilica gel (APSG). The APSG was reacted subsequently with morin yielding morin-bonded silica gel (morin-APSG). The structure was investigated and confirmed by elemental and thermogravimetric analyses, IR and (13)C NMR spectral studies. Morin-APSG was found to be highly stable in common organic solvents, acidic medium (<2molL(-1) HCl, HNO(3)) or alkaline medium up to pH 8. The separation and preconcentration of Ag(I), Au(III), Pd(II), Pt(II) and Rh(III) from aqueous medium using morin-APSG was studied. The optimum pH values for the separation of Ag(I), Au(III), Pd(II), Pt(II) and Rh(III) on the sorbent are 5.7, 2.2, 3.7, 3.7 and 6.8, giving rise to separation efficiencies of 43.9, 85.9, 97.7, 60.9 and 91.0%, respectively, where the activity was found to be >90% in the presence of acetate ion. The ion sorption capacity of morin-APSG towards Cu(II) at pH 5.5 was found to be 0.249mmolg(-1) where the sorption capacities of Ag(I) and Pd(II) were 0.087 and 0.121mmolg(-1) and 0.222 and 0.241mmolg(-1) at pH 2.2 and 5.7, respectively. This indicates a 1:1 and 1:2 morin/metal ratios at pH 2.2 and 5.7, respectively. Complete elution of the sorbed metal ions was carried out using 10mL (0.5molL(-1) HCl+0.01molL(-1) thiourea) in case of Au(III), Pd(II), Pt(II) and Rh(III) and 10mL 0.5molL(-1) HNO(3) in case of Ag(I). Morin-APSG was successfully employed in the separation and preconcentration of the investigated precious metal ions from some spiking water samples yielding 100-folds concentration factor. The relative standard deviation (R.S.D.) and the T-test (|t|(1)) were calculated.  相似文献   

9.
A silica gel based sorbent containing rhodanine as functional group (RDSG) was prepared. Its adsorption and separation characteristics for Ag(I), Au(III) and Pd(II) were studied by flow-injection (FI) on-line preconcentration. Influence of different experimental parameters such as acidity, eluent, co-existing ions were investigated. Trace amounts of Ag, Au and Pd could be efficiently adsorbed by rhodanine-bonded silica gel from acidic solution and eluted with thiourea solution. Common co-existing ions exhibited virtually no interference to the preconcentration and determination. The adsorption capacity of RDSG was 0.0352, 0.107 and 0.122 mmol/g for Ag, Au and Pd, respectively. Detection limits of 0.004, 0.022 and 0.019 microg/mL for Ag, Au and Pd, respectively, were achieved with a sampling time of 60 s at a flow rate of 5.0 mL/min. The relative standard deviation were 0.5%, 0.9% and 1.7% for 0.040 microg/mL Ag, 0.200 microg/mL Au and 0.300 microg/mL Pd. The sorption property did not change after 1,000 cycles of sorption-desorption. The contents of Ag and Au in three national certified ore samples and Pd in a secondary nickel alloy, an anode slime and a CoCl2 electrolytic solution were determined. The results showed good agreement with the certified values.  相似文献   

10.
The functional group capacity and the percentage of functional group conversion of crosslinked polystyrene resin bearing N-methyl-2-thioimidazole (MTIR) synthesized under optimum conditions are as high as 4.08 mmol/g resin and 96.0%, respectively. The apparent activation energies of sorption of MTIR for Au(III) and Pt(IV) are 13.1 and 13.4 kJ/mol, respectively. The sorption behavior of MTIR for Au(III), Pt(IV), and Pd(II) obeys the Freundlich and Langmuir isotherms. The sorption capacities of MTIR for Au(III), Pt(IV), and Pd(II) are as high as 4.33, 2.12, and 2.33 mmol/g resin, respectively. Au(III), Pt(IV), and Pd(II) adsorbed on MTIR can be eluted quantitatively by the eluant. The resin can be regenerated easily and reused without an obvious decrease in the sorption capacity for Au(III) and Pd(II). The resin has high sorption selectivity for noble metal ions. Au(III) can be separated quantitatively in the presence of high concentrations of Cu2+, Fe3+, Ni2+, and Mn2+. The recovery of platinum from the spent industrial catalysts is 98.6% by MTIR. The preconcentration and separation of palladium and platinum from the anode deposits of electrolysis of crude copper have been investigated. The resin may have potential industrial uses.  相似文献   

11.
2-Mercapto-N-2-naphthylacetamide (thionalide) on silica gel is used for rapid preconcentration of μg l?1 levels of palladium(II) from aqueous solution, followed by atomic absorption spectrometric measurement. In batch experiments, palladium was quantitatively retained on the gel from solutions 5 M in acid to pH 8; equilibrium was achieved within 10 s. The chelating capacity of the gel was 7.5 μmol Pd g?1 at pH < 4. The effect of flow rate on retention was studied. Palladium retained on the column was completely eluted with 20 ml of 0.2 M thiourea in 0.1 M hydrochloric acid. The palladium concentration in sea water is shown to be < 0.3 μg l?1.  相似文献   

12.
Amidinothiourea immobilized glass bead (AGB) was applied as the microcolumn packing for the flow-injection online separation and preconcentration of Au(III) and Pd(II) coupled with FAAS determination. The peak-area absorbance (A) and the peak-height absorbance (H) were all used as the evaluating modes. Au(III) and Pd(II) in 0.50 M HCl solution were absorbed onto AGB completely and then eluted into AAS with thiourea solution. Base metal ions with a concentration of 2.0 mg/mL and anions with a concentration of 20.0 mg/mL caused no interference in the determination of Au(III) and Pd(II). The LODs of Au(III) and Pd(II) for a preconcentration time of 60 s with a sampling flow rate of 5.0 mL/min for 0.20 μg/mL of Au(III) and 0.30 μg/mL of Pd(II) were 2.7 and 6.5 ng/mL with the H mode and 4.6 and 10.2 ng/mL with the A mode, respectively. The RSD of seven replicate determinations of 0.20 μg/mL of Au(III) and 0.30 μg/mL of Pd(II) were 0.018 and 0.024 for the H mode and 0.013 and 0.018 for the A mode, respectively. The method was successfully applied to the determination of Au and Pd in real samples. __________ From Zhurnal Analiticheskoi Khimii, Vol. 60, No. 10, 2005, pp. 1023–1029. Original English Text Copyright ? 2005 by Liu, Pu, Su. The text was submitted by the authors in English.  相似文献   

13.
A sensitive and selective kinetic catalytic spectrophotometric method has been described for the determination of trace amounts of palladium(II). The method is based on the catalytic effects of palladium(II) on the reduction reactions of Dahlia Violet with sodium dihydrogen hypophosphite (NaH2PO2) in a sulfuric acid medium. Under optimal conditions, trace amounts of palladium(II) can be determined. A good linear range has been obtained in the concentration range of Pd(II) over 0.001–0.028 μg/mL with a detection limit of 5.9 × 10−10 g/mL. The method has been successfully applied to the determination of palladium(II) in ore and soil samples. The relative standard deviation was less than 5.0% (n = 11). The coexisting ions were eliminated by preconcentration and separation on sulphydryl dextran gel with satisfactory results. The text was submitted by the authors in English.  相似文献   

14.
A method was established for the preconcentration of trace Au(III), Pd(II) and Pt(IV) by activated carbon modified with 3,4-dihydroxycinnamic acid. The separation and preconcentration conditions of analytes were investigated, such as effects of pH, the contacting time, the sample ?ow rate and volume, the elution condition and the interfering ions. At a pH of 1.0, the maximum static sorption capacity of the sorbent was found to be 374.8, 96.6 and 137.5 mg g?1 for Au(III), Pd(II) and Pt(IV), respectively. The adsorbed metal ions were effectively eluted with 2.0 mL of 4% thiourea in 0.5 M HCl solution and determined by inductively coupled plasma optical emission spectrometry. The detection limit (3σ) of this method defined by IUPAC was found to be 0.12, 0.18 and 0.32 ?g L?1 for Au(III), Pd(II) and Pt(IV), respectively. The relative standard deviation (RSD) was lower than 3.0% (n = 8) towards standard solutions. The method has been validated by analysing certified reference materials and successfully applied to the determination of trace Au(III), Pd(II) and Pt(IV) in road sediments samples.  相似文献   

15.
The nucleophilic addition of alcohols, amines and phenol to unactivated alkenes catalyzed by cationic gold and palladium becomes limited due to the fast reduction into metallic gold under reaction conditions. The presence of CuCl2 retards the reduction of Au(III) and Pd", strongly increasing the turnover number of gold and palladium catalysts. It is shown that new Au(III)-CuCl2 and Pd(II)-CuCl2 catalysts are active and selective for the nucleophilic addition of alcohols, amines and phenol to unactivated alkenes.  相似文献   

16.
By using the adsorbent Saccharomyces cerevisiae immobilized on sepiolite an adsorption-elution method was developed for the preconcentration of Cu, Zn, and Cd followed by flame atomic absorption spectrometry (FAAS). Recoveries were 98.3 ± 0.4% for Cu, 94.2 ± 0.3% for Zn, and 99.04 ± 0.04% for Cd at 95% confidence level obtained by the column method. The influence of sea water matrix elements on the separation of the trace elements was also assessed by using the column procedure. The breakthrough capacities were found to be 74 μmol/g for copper, 128 μmol/g for zinc and 97 μmol/g for cadmium. After optimization the proposed method was applied to the trace metal determination in sea and river water. Received: 8 June 1998 / Revised: 8 September 1998 / Accepted: 16 September 1998  相似文献   

17.
Iglesias M  Anticó E  Salvadó V 《Talanta》2003,59(4):651-657
A preconcentration method is developed for the on-line determination of palladium in complex matrices with flame atomic absorption spectrometry (FAAS). The flow system comprised of a minicolumn filled with polyamine Metalfix-Chelamine resin which is highly selective for Pt(IV), Au(III) and Pd(II). Best preconcentration conditions are established by testing different resin quantities, sample and eluent solution volumes, and adsorption and elution steps flow rates. Sample volumes of 4.7 ml of palladium solutions resulted in an enrichment factor of twenty at the optimum hydrodynamic conditions. This value can be increased by injecting larger volumes of sample solution. The method is sensitive, easy to operate and permitted the determination of sub-mg l−1 levels of palladium with a detection limit of 0.009 mg l−1. The resin was used up to 60 times in consecutive retention-elution cycles without any appreciable deterioration in its performance. The applicability of this method was tested by determining the palladium content in synthetic geological samples as well as in the pellet-type used car catalyst reference material.  相似文献   

18.
A simple and highly selective flow injection (FI) on-line preconcentration and separation flame atomic absorption spectrometric (FAAS) method was developed for the determinations of trace amounts of silver, gold and palladium. The selective preconcentration of the noble metals was achieved in a wide range of sample acidity (0.1-6 M HNO3 or HCl) on a microcolumn packed with amidinothioureido-silica gel (ATuSG). The analytes retained on the column were effectively eluted with 5.0% thiourea solution. The analytical procedure was optimized for sample acidity, elution, interferences, flow rate of sampling and eluting, and concentration of sample. Common co-existing cations and anions did not interfere with the preconcentration and determination of the three metals. At a sample loading flow rate of 4.5 ml min−1 with 60 s preconcentration, detection limits (3σ) of 1.1 ng ml−1 Ag, 13 ng ml−1 Au and 17 ng ml−1 Pd were obtained. The precisions (R.S.D., n=11) were 1.2% for Ag, 1.2% for Au and 1.7% for Pd, respectively. The detection limits can be further improved by increasing sample volume. The analytical results obtained by the proposed method for a number of standard reference materials were in good agreement with the certified values.  相似文献   

19.
Physico-chemical characteristics and sorption activity of carbon, organosilica sorbents and their modified forms towards proteins, possessing specific activity, and cholerae vibrio have been studied. It was found, that carbon materials modified by copper (II) effectively extracts cholerae vibrio (100%) and may be recommended for disinfection of drinking water. Sorption capacity of organosilica sorbents and their modified by copper (II) forms towards pathogenic microflora (E.coli, St.aureus, Ps.aeruginosa) depending on the composition of the sorbents, concentration of the modified reagent, pH of medium have been evaluated. The rows of the increase of sorption of pathogenic microorganisms by synthetic sorbents in water-salt solutions were established: Al(III)<Zn(II)<Cu (II). It was shown that inhibiting effect of modified synthetic organosilica and natural sorbents towards such pathogenic microorganisms as E-coli, St.aureus Ps.aeruginosa and fungus Bacillus pyocyaneus accordingly is equal 80–98%.  相似文献   

20.
A new sorbent based on cysteine modified silica gel (SiG-cys) was prepared and studied for preconcentration and separation of noble metals Au(III), Pd(II), Pt(II), Pt(IV). Its extraction efficiency was examined by batch and column solid phase extraction procedures. Laboratory experiments performed showed that sorbent is characterized with high selectivity, permiting quantitative sorption (93–97%) of noble metals Au, Pd and Pt from acidic media 0.1–2 mol L? 1 HCl and unsignificant sorption (less than 2%) for common base metals like Cu, Fe, Mn and Zn. The analytes retained on the sorbent are effectively eluted with 0.1 mol L? 1 thiourea in 0.1 mol L? 1 HCl and measured by ETAAS or ICP OES under optimal instrumental parameters. The sorbent showed high mechanical and chemical stability and extraction efficiency was not changed after 500 cycles of sorption/desorption. The sorbent was successfully applied in analyticals procedures for preconcentration and determination of Au, Pd and Pt in geological and soil samples. Detection limits (3σ criteria) achieved, depending on the instrumental methods used are: ETAAS (0.005 μg L? 1 for Au in river and sea water, 0.002 μg g? 1 for Au in copper ore and copper concentrate); ICP OES (0.03 μg L? 1 for Pd and 0.06 μg L? 1 for Pt in river and sea water, 0.006 μg g? 1 for Pd in copper ore and copper concentrate and 0.002 μg g? 1 for soluble Pt in soil). The accuracy of the procedures developed was confirmed by added/found method for sea and river water; by the analysis of national certified materials (copper ore and copper concentrate for Au and Pd) and by determination of the sum of soluble Pt(II) + Pt(IV) in spiked soil samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号