首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
《Electroanalysis》2005,17(17):1517-1522
In this paper, we report the first attempt to use humic acid (HA) as modifiers to prepare the organic‐inorganic hybrid modified glassy carbon electrodes based on HA‐silica‐PVA (poly(vinyl alcohol)) sol‐gel composite. Electroactive species of tris(2,2′‐bipyridyl)ruthenium(II) (Ru(bpy) ) can easily incorporate into the HA‐silica‐PVA films to form Ru(bpy) modified electrodes. The amount of Ru(bpy) incorporated in the composite films strongly depends on the amount of HA in the hybrid sol. Electrochemical and electrogenerated chemiluminescence (ECL) of Ru(bpy) immobilized in HA‐silica composite films coated on a glassy carbon electrode have been studied with tripropylamine (TPA) as the coreactant. The analytical performance of this modified electrode was evaluated in a flow injection analysis (FIA) system with a homemade flow cell. The as‐prepared electrode showed good stability and high sensitivity. The detection limits (S/N=3) were 0.050 μmol L?1 for TPA and 0.20 μmol L?1 for oxalate, and the linear ranges were from 0.10 μmol L?1 to 1.0 mmol L?1 for TPA and from 1.0 μmol L?1 to 1.0 mmol L?1 for oxalate, respectively. The resulting electrodes were stable over two months.  相似文献   

2.
A novel electrogenerated chemiluminescence (ECL) sensor based on Ru(bpy)32+‐doped titania (RuDT) nanoparticles dispersed in a perfluorosulfonated ionomer (Nafion) on a glassy carbon electrode (GCE) was developed in this paper. The electroactive component‐Ru(bpy)32+ was entrapped within the titania nanoparticles by the inverse microemulsion polymerization process that produced spherical sensors in the size region of 38±3 nm. The RuDT nanoparticles were characterized by electrochemical, transmission electron and scanning microscopy technology. The Ru(bpy)32+ encapsulation interior of the titania nanoparticles maintains its ECL efficiency and also reduces Ru(bpy)32+ leaching from the titania matrix when immersed in water due to the electrostatic interaction. This is the first attempt to prepare the RuDT nanoparticles and extend the application of electroactive component‐doped nanoparticles into the field of ECL. Since a large amount of Ru(bpy)32+ was immobilized three‐dimensionally on the electrode, the Ru(bpy)32+ ECL signal could be enhanced greatly, which finally resulted in the increased sensitivity. The ECL analytical performance of this ECL sensor for tripropylamine (TPA) was investigated in detail. This sensor shows a detection limit of 1 nmol/L for TPA. Furthermore, the present ECL sensor displays outstanding long‐term stability.  相似文献   

3.
An ultrasensitive electrogenerated chemiluminescence (ECL) immunoassay was proposed by using magnetic nanobeads (MNBs) as the carrier of ECL labels for ECL emission amplification. Carcinoembryonic antigen (CEA) and MNBs were initially immobilized on a platform in 1 : 1 molar ratio via sandwich immunoreaction. Subsequently, the MNBs were released from the platform and labeled with Ru(bpy)32+ species. After the MNBs with Ru(bpy)32+ were immobilized on an Au electrode, ECL of the Ru(bpy)32+ was measured for CEA determination. A linear relation between the ECL intensity and CEA concentration was obtained in a range of 1×10?14 to 3×10?13 mol/L (2.0 to 60 pg/mL) with a limit of detection of 8.0×10?15 mol/L (1.6 pg/mL).  相似文献   

4.
Electrochemical behavior and electrogenerated chemiluminescence (ECL) of tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) immobilized in poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate)-poly(vinyl alcohol) (PEDOT/PSS-PVA) composite films via ion-exchange have been investigated with tripropylamine (TPA) as the co-reactant at a glassy carbon electrode. The immobilized Ru(bpy)32+ performed a surface-controlled electrode reaction. The Ru(bpy)32+ modified electrode showed a fast ECL response to TPA, and was used for the ECL detection of TPA with high sensitivity. The ECL intensity was linearly related to concentrations of TPA over the range from 0.50 μmol L−1 to 0.80 mmol L−1, and the detection limit was 0.10 μmol L−1 (S/N = 3). The as-prepared electrode exhibited good precision and long-term stability for TPA determination.  相似文献   

5.
An electrogenerated chemiluminescence (ECL) sensor for reduced glutathione was developed based on $ \mathrm{Ru}\left( {\mathrm{bpy}} \right)_3^{2+ } $ -doped silica nanoparticles-modified gold electrode (Ru-DSNPs/Au). These uniform Ru-DSNPs (about 58?+?4 nm) were prepared by a water-in-oil microemulsion method and characterized by transmission electron microscope and scanning electron microscope. With such a unique immobilization method, a considerable $ \mathrm{Ru}\left( {\mathrm{bpy}} \right)_3^{2+ } $ was immobilized three dimensionally on the electrode, which could greatly enhance the ECL response and thus result in an increased sensitivity. The ECL analytical performances of this sensor for reduced glutathione based on the quenched ECL emission of $ \mathrm{Ru}\left( {\mathrm{bpy}} \right)_3^{2+ } $ have been investigated in detail. Under the optimum condition, the ECL intensity was linear with the reduced glutathione concentration in the range of 1.0?×?10?9 to 1.0?×?10?4?mol?L?1 (R?=?0.9971). This method has been successfully applied for the determination of reduced glutathione in serum samples with satisfactory results. The as-prepared ECL sensor for the determination of reduced glutathione displayed good sensitivity and stability.  相似文献   

6.
Mesoporous titania‐Nafion composite doped with carbon nanotube (CNT) has been used for the immobilization of tris(2,2′‐bipyridyl)ruthenium(II) (Ru(bpy)32+) and alcohol dehydrogenase on an electrode surface to yield a highly sensitive and stable electrogenerated chemiluminescence (ECL) ethanol biosensor. The presence of CNT in the composite film increases not only the sensitivity of the ECL biosensor but also the long‐term stability of the biosensor. The present biosensor responds linearly to ethanol in the wide concentration ranges from 1.0×10?5 M to 1.0×10?1 M with a detection limit of 5.0×10?6 M (S/N=3). The present ECL ethanol biosensor exhibited higher ECL response compared to that obtained with the ECL biosensor based on the corresponding composite without CNT. The present CNT‐based ECL biosensor showed good long‐term stability with 75% of its initial activity retained after 2 weeks of storage in 50 mM phosphate buffer at pH 7.0.  相似文献   

7.
A simple, selective and sensitive “signal-on” electrogenerated chemiluminescence (ECL) biosensing method was developed for matrix metalloproteinase 2 (MMP-2). Ru(bpy)32+, gold nanoparticles (AuNPs) and Nafion were modified onto glassy carbon electrode (GCE) to form Ru(bpy)32+/AuNPs/Nafion/GCE as sensitive ECL platform and then ferrocene (Fc) labeled peptide was assembled onto the modified electrode to form ECL biosensing platform. The ECL intensity increased when the ECL biosensing electrode reacted with MMP-2 because of MMP-2-induced cleavage of Fc labeled peptide. The ECL method was applied to determine MMP-2 with detection limit of 0.3 ng/mL and one-step recognition, which is promising for point-of-care test of protease.  相似文献   

8.
本文应用核酸适配体构建了一种新型的电致化学发光检测蛋白体系。两个核酸适配体结合凝血酶的两个不同位点,利用这两核酸适配体与凝血酶的高亲和力构建三明治传感体系检测凝血酶。一个核酸适配体固定在金电极上用来捕获凝血酶,另一个标记有包裹电致化学发光活性物Ru(bpy)32+的二氧化硅纳米颗粒,用来检测电致化学发光信号。此核酸适配体传感器对凝血酶具有特异识别性,电致化学发光信号与凝血酶的浓度直接相关,非特异性识别的牛血红蛋白、牛血清白蛋白不干扰测定。由于在检测的核酸适配体上标记的纳米颗粒包裹有多个发光活性物,因此大大提高了发光效率和灵敏度,此法对凝血酶的线性响应范围为2.0 fmol•L-1~2.0 pmol•L-1,检测限可达1.0 fmol•L-1。  相似文献   

9.
The electrochemical behavior of electrochemical deposition of Au nanoparticles onto a glassy carbon electrode (GCE) and its application for the electrocatalytic electrogenerated chemiluminescence (ECL) of Ru(bpy)32+ in an aqueous solution without coreaction are investigated in this report. The modification of GCE by Au nanoparticles results in excellent catalysis of the ECL of Ru(bpy)32+. The effects of various factors, such as potential scan range, the presence of nitrogen and oxygen, and the scan rate on Ru(bpy)32+. ECL peaks, were systematically studied. This article has provided insight into the design of an Au-nanoparticle-modified electrode for ECL, analytical and catalytic applications. Published in Russian in Elektrokhimiya, 2008, Vol. 44, No. 9, pp. 1127–1132. The text was submitted by the authors in English.  相似文献   

10.
Guo Z  Shen Y  Zhao F  Wang M  Dong S 《The Analyst》2004,129(7):657-663
The electrochemical and electrogenerated chemiluminescence of Ru(bpy)(3)(2+) immobilized in [clay/Ru(bpy)(3)(2+)](n) multilayer films by layer-by-layer assembly were investigated. The stable multilayer films of clay and Ru(bpy)(3)(2+) were assembled by alternate adsorption of negatively charged clay platelets and positively charged Ru(bpy)(3)(2+) from their aqueous dispersions. UV-vis spectroscopy, quartz crystal microbalance (QCM), cyclic voltammetry, and electrogenerated chemiluminescence (ECL) were used to monitor the immobilization of Ru(bpy)(3)(2+) and the regular growth of the [clay/Ru(bpy)(3)(2+)](n) multilayer films. The multilayer films modified electrode was used for the ECL detection of tripropylamine (TPA) and oxalate. The proposed novel immobilized method exhibited good stability, reproducibility and high sensitivity for the determination of TPA and oxalate, which mainly resulted from the contributing of clay nanoparticles with appreciable surface area, special structural features and unusual intercalation properties. Detection limits were 20 and 100 nM for TPA and oxalate, respectively and the linear concentration range extended from 60 nM to 0.66 mM for TPA.  相似文献   

11.
Lei R  Xu X  Xu D  Zhu G  Li N  Liu H  Li K 《Analytica chimica acta》2008,625(1):13-21
Anodic Ru(bpy)32+ electrogenerated chemiluminescence (ECL) can be enhanced by polyphenols in alkaline solution. Spin trapping-electron spin resonance (ESR) experiments verified that reactive oxygen species (ROS) were generated during the electrolysis of Ru(bpy)32+ in alkaline solution, and oxidation of quercetin enhanced Ru(bpy)32+ ECL at anodic potential by producing additional ROS. This ECL enhancement can be used to analyze real sample and evaluate antioxidant activity of polyphenols.  相似文献   

12.
Mesoporous films of platinized carbon nanotube–zirconia–Nafion composite have been used for the immobilization of tris(2,2′‐bipyridyl)ruthenium (II) (Ru(bpy)32+) on an electrode surface to yield a solid‐state electrogenerated chemiluminescence (ECL) sensor. The composite films of Pt–CNT–zirconia–Nafion exhibit much larger pore diameter (3.55 nm) than that of Nafion (2.82 nm) and thus leading to much larger ECL response for tripropylamine (TPA) because of the fast diffusion of the analyte within the films. Due to the conducting and electrocatalytic features of CNTs and Pt nanoparticles, their incorporation into the zirconia–Nafion composite films resulted in the decreased electron transfer resistance within the films. The present ECL sensor based on the Pt–CNT–zirconia–Nafion gave a linear response (R2=0.999) for TPA concentration from 3.0 nM to 1.0 mM with a remarkable detection limit (S/N=3) of 1.0 nM, which is much lower compared to those obtained with the ECL sensors based on other types of sol‐gel ceramic–Nafion composite films such as silica–Nafion and titania–Nafion.  相似文献   

13.
《Analytical letters》2012,45(11):2311-2326
ABSTRACT

The effects of heteropoly acids and Triton X-100 on electrochemiluminescence (ECL) of Ru(bpy)3 2+ are investigated. Triton X-100 prevents the oxidation of oxalate and results in an increase of the ECL signal. H5SiW11VO40 prevents the direct oxidation of oxalate and makes the electrochemical behavior of Ru(bpy)3 2+ less reversible, which leads to a decrease of the ECL signal. In contrast, H3PMo12O40 has negligible effect on ECL intensity. Some possible reasons for the effects on the ECL of Ru(bpy)3 2+ are discussed based on the adsorption of SiW11VO40 5? on electrode surface and the ion association between SiW11VO40 5? and Ru(bpy)3 2+. The signal of ECL decreases linearly with the concentration of heteropoly acid in the range from 2x10?6 to 1x10?4 mol 1?1. The results indicate that ECL of Ru(bpy)3 2+ is a potential sensitive and selective detection method for heteropoly acids and hence for the elements comprised in them.  相似文献   

14.
A highly sensitive and stable tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)32+ immobilized in the ECL sensor by adsorption of Ru(bpy)32+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both titania-Nafion composite films without CNT and pure Nafion films. The present Ru(bpy)32+ ECL sensor based on the MWCNT-titania--Nafion composite gave a linear response (R2 = 0.999) for TPA concentration from 50 nM to 1.0 mM with a remarkable detection limit (S/N = 3) of 10 nM while the ECL sensors based on titania-Nafion composite without MWCNT, pure Nafion films, and MWCNT-Nafion composite gave a detection limit of 0.1 μM, 1 μM, and 50 nM, respectively. The present ECL sensor showed outstanding long-term stability (no signal loss for 4 months).  相似文献   

15.
利用静电吸附作用将联吡啶钌[Ru(bpy)32+]负载到巯基化MCM-41介孔二氧化硅纳米颗粒上, 通过金-巯键修饰法将负载后的MCM-41固定在金电极表面, 发展了一种基于MCM-41负载联吡啶钌的电致化学发光传感器, 并研究了其电化学及电致化学发光行为. 基于三聚氰胺与增敏剂三正丙胺氨基结构的相似性, 将负载Ru(bpy)32+的MCM-41电致化学发光传感器用于三聚氰胺的检测, 获得了良好的检测效果, 为检测三聚氰胺提供了一种快速、简便的方法. 同时, 该研究为Ru(bpy)32+在电极表面的固定化提供了新思路.  相似文献   

16.
The electrochemical and electrogenerated chemiluminescence (ECL) properties of indium tin oxide (ITO) electrodes modified with poly(4-vinylpyridine) (PVP)-bound Ru(bpy)2Cl+ (where bpy = 2,2′-bipyridine) have been studied. In a sodium oxalate solution, two irreversible oxidation waves as well as two ECL emission waves were observed during the potential scan in the range 0.4-1.4 V (versus Ag/AgCl/saturated KCl reference). The first ECL wave appeared at ca. 0.8 V, which was caused by the excited-state Ru2+* generated through a bimolecular redox reaction between electrogenerated Ru3+ and the strong reducing agent, CO2. The latter was formed via a Ru3+-mediated oxidation of oxalate. Direct oxidation of oxalate was not involved in the first ECL process. The second ECL wave started at ca. 1.1 V, which was also from the excited-state Ru2+* generated via the redox reaction between Ru3+ and CO2. However, both direct and Ru3+-mediated oxidation of oxalate contributed to the formation of CO2. The important role of the direct oxidation of oxalate in the ECL mechanism of PVP-bound Ru(bpy)2Cl+/oxalate system was demonstrated. The relative contribution of direct oxidation of oxalate to the observed ECL depended upon the surface concentration of PVP-bound Ru2+, the concentration of oxalate and the electrode potential applied.  相似文献   

17.
A novel electrogenerated chemiluminescence (ECL) sensor based on natural clay and ionic liquid was fabricated. Tris(2,2′‐bipyridine)ruthenium(II) (Ru(bpy)32+) was immobilized on natural clay surface through simple adsorption. An ECL sensor was prepared by mixing Ru(bpy)32+‐incorporated clay, graphite powder and an ionic liquid (1‐butyl‐3‐methylimidazolium hexafluorophosphate) as the binder. The electrochemical behavior and ECL of the immobilized Ru(bpy)32+ was investigated. It was observed that the ECL of immobilized Ru(bpy)32+ was activated by the ionic liquid. The proposed ECL sensor showed high sensitivity to tri‐n‐propylamine (TPrA) and the detection limit was found to be 20 pM. In addition, the ECL sensor displayed good stability for TPrA detection and long‐term storage stability.  相似文献   

18.
Chemiluminescence emission intensity is modulated by modulating the potential of a working electrode which is used to generate a key species in the electrogenerated Chemiluminescence (ECL) reaction. The emission is monitored synchronously using a lock-in amplifier. The reactions used in the characterization are luminol with hydrogen peroxide and tris(2,2-bipyridyl)ruthenium (II) (or Ru(bpy) 3 2+ ) with oxalate. Modulation widths of ± 50 mV yield maximum signals for luminol when centered at 0.45 V (vs Ag/AgCl) and for Ru(bpy) 3 2+ when centered at 1.05 V. The resulting signal decreases with increasing modulation frequency and shows that luminol/H2O2 is a faster ECL system than Ru(bpy) 3 2+ /oxalate. Working curves for luminol and for oxalate have essentially the same linear range and slope with the modulated potential approach as with a DC electrode potential. This approach provides capability for differentiating the analytical signal from constant background emission or stray light.  相似文献   

19.
Ru(bpy) 3 2+ electrogenerated chemiluminescence (CL) has rapidly gained importance as a sensitive and selective detection method in analytical science. The Ru(bpy) 3 2+ ECL is observed when Ru(bpy) 3 3+ reacts with Ru(bpy) 3 + and yields an excited state Ru(bpy) 3 2+* . ECL emission can also be obtained when a variety of oxidants and reductants react with the reduced or oxidized forms of Ru(bpy) 3 2+ . Either the reductant or the oxidant can be treated as an analyte. The Ru(bpy) 3 2+ ECL is used as a detection method for the determination of oxalate and a variety of amine-containing analytes without derivatization in flowing streams such as flow injection and HPLC. When the ECL format is used as a detector for HPLC, unstable post-column reagent addition can often be eliminated and, the problems of both sample dilution and band broadening can be avoided because the Ru(bpy) 3 3+ species are generatedin situ in the reaction/observation flow cell. Since NADH is sensitively detected with the Ru(bpy) 3 2+ ECL, many clinically important analytes can be detected by coupling them to dehydrogenase enzymes that utilize -nicotinamide adenine cofactors to convert NAD+ to NADH. Ru(bpy) 3 2+ -derivatives are used as CL labels for immunoassay and PCR assay with Ru(bpy) 3 2+ /tripropylamine ECL system. The Ru(bpy) 3 2+ ECL label can be sensitively determined at subpicomolar concentrations, along with an extremely wide dynamic range of greater than six orders of magnitude. Furthermore, it can eliminate disposal and lifetime problems inherent in radio immunoassays. In this paper, basic principles of the Ru(bpy) 3 2+ ECL are discussed. In addition, analytical applications of the Ru(bpy) 3 2+ ECL are illustrated with examples.  相似文献   

20.
Electrochemiluminescence (ECL) of tris(2,2′‐bipyridine)ruthenium, Ru(bpy)32+ in the presence of various co‐reactants, such as tripropylamine (TPA), oxalate ion (C2O42?), ascorbic acid (H2A) and dehydroascorbic acid (DHA), were investigated under ultrasound irradiation. In sono‐ECL experiments, an indium‐thin‐oxide (ITO) was used as working electrode, and a titanium tipped sonic horn probe (diameter 2 mm) which operated at a frequency of 20 kHz was set in the front of the ITO electrode. Under the ultrasound irradiation, ECL signals were found to be significantly enhanced when TPA and C2O42? were used as co‐reactants, only slightly enhanced in Ru(bpy)32+/DHA system, but total quenched in Ru(bpy)32+/H2A system. The difference of Ru(bpy)32+ ECL behaviors for various co‐reactant could to be due to the different kinetics of catalytic reactions associated in ECL schemes. ECL quenching effect observed in Ru(bpy)32+/H2A system was suggested to be due to electron transfer (ET) route between the excited state *Ru(bpy)32+ and ascorbate anion HA? diffused from the bulk solution, where the diffusional HA? species served as electron donor. The effect becomes more pronounced upon sonication because the effective collision frequency between *Ru(bpy)32+ and HA? would be significantly increased by the enhanced mass transport effect of ultrasound.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号