首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, a novel electrochemiluminescence (ECL) sensor for highly sensitive and selective detection of Pb(II) was developed based on Ru(bpy)32+ encapsulated UiO66 metal‐organic‐framework (Ru(bpy)32+?UiO66 MOF) and ?NH2 group functionalized silica (NH2?SiO2). The NH2?SiO2 with large surface area provided an excellent platform for the ECL sensor. As numerous exposed carboxyl groups were present on UiO66 backbone, the Ru(bpy)32+?UiO66 could be steadily immobilized to NH2?SiO2 by forming amide bonds. Meanwhile, the introduced UiO66 MOF which used for the encapsulation of Ru(bpy)32+, significantly enhanced the ECL efficiency of the proposed sensor, as it possessed a large specific surface area and porosity for the loading of Ru(bpy)32+. Moreover, a high quenching effect on ECL intensity was obtained in the presence of Pb(II) in the electrolyte. Under the optimal conditions, the quenched ECL intensity showed a good linear relationship within Pb(II) concentration in the range from 1.0×10?6 to 1.0×102 μM, with a detection limit of 1.0×10?7 μM (S/N=3). The proposed sensor for Pb(II) detection was simple in operation, rapid in testing, stable in signal, and showed a good anti‐interference ability to some other metal ions. Besides, its application for detecting Pb(II) in a real sample was also investigated here. This work provides a potential platform for metal ions detection in environmental monitoring field.  相似文献   

2.
《Analytical letters》2012,45(13):2077-2088
Abstract

An electrochemiluminescence (ECL) method for reduced nicotinamide adenine dinucleotide (NADH) was proposed by immobilizing tris(2,2′‐bipyridyl) ruthenium(II) (Ru(bpy)3 2+) in multiwall carbon nanotubes (MWCNTs)/Nafion composite membrane that was formed on glassy carbon electrode surface. The electrochemical and ECL behaviors of the immobilized Ru(bpy)3 2+ were investigated. The cyclic votammogram of the modified electrode in pH 7.0 phosphate buffer solution showed a couple of redox peaks at +1190 and +1060 mV at 100 mV/s. The composite film had a more open structure and a large surface area allowing faster diffusion of Ru(bpy)3 2+. The presence of MWCNTs resulted in the improved ECL sensitivity and longer‐term stability of the modified electrode. The modified electrode showed a linear response to NADH in the concentration range of 1.0×10?6 to 1.6×10?5 M with a detection limit of 8.2×10?7 M.  相似文献   

3.
A novel [Ru(bpy)2(dcbpy)NHS] labeling/aptamer‐based biosensor combined with gold nanoparticle amplification for the determination of lysozyme with an electrochemiluminescence (ECL) method is presented. In this work, an aptamer, an ECL probe, gold nanoparticle amplification, and competition assay are the main protocols employed in ECL detection. With all the protocols used, an original biosensor coupled with an aptamer and [Ru(bpy)2(dcbpy)NHS] has been prepared. Its high selectivity and sensitivity are the main advantages over other traditional [Ru(bpy)3]2+ biosensors. The electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM) characterization illustrate that this biosensor is fabricated successfully. Finally, the biosensor was applied to a displacement assay in different concentrations of lysozyme solution, and an ultrasensitive ECL signal was obtained. The ECL intensity decreased proportionally to the lysozyme concentration over the range 1.0×10?13–1.0×10?8 mol L?1 with a detection limit of 1.0×10?13 mol L?1. This strategy for the aptasensor opens a rapid, selective, and sensitive route for the detection of lysozyme and potentially other proteins.  相似文献   

4.
《Electroanalysis》2004,16(17):1401-1405
The immobilization of tris(2,2′‐bipyridyl)ruthenium(II), Ru(bpy)32+, at a glassy carbon electrode was achieved by entrapping the Ru(bpy)32+ in a vapor deposited titania sol‐gel membrane. The electrogenerated chemiluminescence (ECL) of the immobilized Ru(bpy)32+ was studied. The Ru(bpy)32+ modified electrode showed a fast ECL response to both oxalate and proline. The ECL intensity was linearly related to concentrations of oxalate and proline over the ranges from 20 to 700 μmol L?1 and 20 to 600 μmol L?1, respectively. The detection limits for oxalate and proline at 3σ were 5.0 μmol L?1 and 4.0 μmol L?1, respectively. This electrode possessed good precision and stability for oxalate and proline determinations. The electrogenerated chemiluminescence mechanism of proline system was discussed. This work provided a new way for the immobilization of Ru(bpy)32+ and the application of titania sol‐gel membrane in electrogenerated chemiluminescence.  相似文献   

5.
A carbon fiber paste electrode using ionic liquid as the binder (CFILE) was fabricated. The electrochemical characteristics of the electrode was examined in ferro‐/ferricyanide solution and showed better conductivity and reversibility when compared with graphite paste‐ionic liquid electrode (GPILE) and a little better than that on the carbon nanotube paste‐ionic liquid electrode (CNTILE). Glyphosate (GLY), a pesticide, exhibited excellent catalysis to the oxidation of Ru(bpy)2+3 on CFILE and brought an obvious enhancement to the electrochemiluminescence (ECL) intensity of Ru(bpy)2+3. Based on the catalytic ability of GLY, a simple ECL method for GLY detection had been established. Under optimum conditions, the enhanced ECL intensities were found to had linearly respond to the GLY concentration between 3.0×10?7 and 3.0×10?5 mol/L, and the detection limit (S/N=3) was 2.0×10?7 mol/L. The electrode also showed excellent sensitivity in detecting GLY‐spiked soybean samples. The linear range for GLY in soybean samples was 1.0×10?6–4.0×10?5 mol/L and the detection limit was 5.0×10?7 mol/L, equal to 8.45 µg GLY in per gram of soybean. The detection limit in soybean sample was lower than the USA, EU regulation and so on. If the method is coupled with the separation technology, it can be applied to detect the GLY in the contaminated samples.  相似文献   

6.
Tripropylamine (TPA) is a highly toxic and carcinogenic compound, therefore, TPA concentration in water must be monitored to protect health and the environment. In this paper, an electrochemiluminescent (ECL) sensor was fabricated by immobilising Ru(bpy)32+‐modified CuO nanoparticles (NPs) on a TiO2 nanotube array (TN) electrode. Compared to an ECL sensor fabricated by immobilising Ru(bpy)32+ on a TN only electrode, the as‐prepared sensor displays a 30 % enhanced ECL signal and a detection limit of 9.6×10?10 M at a signal‐to‐noise ratio=3 with the concentration of TPA in a range 1×10?9 to 1×10?5 M. The results from this study indicated a new approach for the enhancement of performance of ECL sensor in detecting TPA in water.  相似文献   

7.
《Electroanalysis》2004,16(3):169-174
A fast and sensitive approach to detect reserpine in urine using micellar electrokinetic capillary chromatography with electrochemiluminescence (ECL) of Ru(bpy)32+ detection is described. Using a 25 μm i.d. capillary as separation column, the ECL detector was coupled to the capillary in the absence of an electric field decoupler. Field‐amplified injection was used to minimize the effect of ionic strength in the sample and to achieve high sensitivity. In this way, the sample was analyzed directly without any pretreatment. The method was validated for reserpine in the urine over the range of 1×10?6?1×10?4 mol/L with a correlation coefficient of 0.996. The RSD for reserpine at a level of 5 μmol/L was 4.3%. The LOD (S/N=3) was estimated to be 7.0×10?8 mol/L. The average recoveries for 10 μmol/L reserpine spiked in human urine were 94%.  相似文献   

8.
An electrogenerated chemiluminescence (ECL) sensor for reduced glutathione was developed based on $ \mathrm{Ru}\left( {\mathrm{bpy}} \right)_3^{2+ } $ -doped silica nanoparticles-modified gold electrode (Ru-DSNPs/Au). These uniform Ru-DSNPs (about 58?+?4 nm) were prepared by a water-in-oil microemulsion method and characterized by transmission electron microscope and scanning electron microscope. With such a unique immobilization method, a considerable $ \mathrm{Ru}\left( {\mathrm{bpy}} \right)_3^{2+ } $ was immobilized three dimensionally on the electrode, which could greatly enhance the ECL response and thus result in an increased sensitivity. The ECL analytical performances of this sensor for reduced glutathione based on the quenched ECL emission of $ \mathrm{Ru}\left( {\mathrm{bpy}} \right)_3^{2+ } $ have been investigated in detail. Under the optimum condition, the ECL intensity was linear with the reduced glutathione concentration in the range of 1.0?×?10?9 to 1.0?×?10?4?mol?L?1 (R?=?0.9971). This method has been successfully applied for the determination of reduced glutathione in serum samples with satisfactory results. The as-prepared ECL sensor for the determination of reduced glutathione displayed good sensitivity and stability.  相似文献   

9.
When the concentration of dodecyl benzene sulfonic acid sodium salt (SDBS) is 0.7 mmol·L?1, the electrochemical and electrochemiluminescence (ECL) intensity of Ru(bpy)32+‐chlorpheniramine maleate (CPM) system at the Au electrode were studied. The results showed that compared with the absence of SDBS, enhancement of the ECL intensity was 14‐fold at Au electrode. Base on this, an ECL method was established for efficient and simple determination of CPM at Au electrode. Under the optimum experimental condition, the enhanced ECL intensities had good linear relationship with the concentration of CPM in the range of 1.0×10?4–1.0×10?7 mol·L?1, and a linear regression equation was obtained as follows: I (counts)=48.805×106c+394.03 (r=0.9975), the detection limit for CPM was 1.4×10?8 mol·L?1. The RSD for 5 times determinations of 1.0×10?5 mol·L?1 CPM was 3.2%. The results of recovery test were between 96.3%–102.5%, and the RSD of recovery test (n=5) was 2.7%. In addition, eleven kinds of tertiary amines‐Ru(bpy)32+ systems were investigated in the absence and presence of SDBS. The results showed that the enhancement of SDBS on ECL intensity of tertiary amines‐Ru(bpy)32+ systems was universal.  相似文献   

10.
Yulong Gao  Tao Wang  Fengyu Liu 《中国化学》2016,34(12):1297-1303
The electrochemiluminescence (ECL) of the Ru(phen)32+/thymine (T) system at bare and graphene oxide (GO)‐modified glassy carbon (GC) electrodes was utilized to determine Hg2+ in tap water. The ECL intensity of Ru(phen)32+ was considerably enhanced by the addition of thymine because of the occurrence of ECL reaction between them. Subsequently, the ECL intensity of Ru(phen)32+/T system rapidly decreased with the addition of Hg2+ because of the formation of a T‐Hg2+‐T complex. A linear response (R2=0.9914) was obtained over a Hg2+ concentration range of 1.0×10?9 mol/L to 1.0×10?5 mol/L with a detection limit of 3.4×10?10 mol/L at a bare GC electrode in 0.1 mol/L phosphate buffer (pH=8.0). The detection limit can be further reduced to 4.2×10?12 mol/L after modification of the GC electrode by GO. To verify its applicability, the proposed method was utilized to determine Hg2+ in tap water and simulated wastewater. The method exhibited good reproducibility and stability and thus reveals the possibility of developing a novel ECL detection method for Hg2+.  相似文献   

11.
A new method to estimate the leucine aminopeptidase (LAP, EC 3.4.11.1) activity using capillary electrophoresis coupled with electrochemiluminescence (ECL) is described. The liberated proline produced by LAP catalyzing the hydrolysis reaction of leucin–proline was used as an ECL coreagent to enhance Ru(bpy)32+ ECL signals efficiently. The detection limit for proline was 2.88 × 10?6 m (signal‐to‐noise ratio 3), which was equal to 9.60 × 10?8 units of LAP being used to catalyze leucin–proline for 1 min. The Michaelis constant Km (2.07 × 10?2 mol/L) and the maximum reaction velocity Vmax (1.06 × 10?5 mol/L/min) of LAP for leucin–proline are reported. The reaction conditions including the concentration of metal ions, incubation temperature and pH were optimized. This method was successfully applied to detect LAP activity in plasma and the results were in good agreement with that obtained by the clinical method. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Many cathodic electrochemiluminescence (ECL) systems require very negative potentials; it is difficult to achieve stable cathodic ECL in aqueous solutions because of hydrogen evolution and instability of intermediates. In this study, tricresyl phosphate-based carbon paste electrode (CPE) was used to achieve cathodic ECL. It exhibits no obvious hydrogen evolution even at a potential up to ?1.6 V and dramatically stabilizes electrogenerated [Ru(bpy)3]+. Therefore, a reversible wave of [Ru(bpy)3]2+/1+ in aqueous solutions at carbon electrode has been observed for the first time, and cathodic ECL of [Ru(bpy)3]2+/S2O 8 2? has been achieved. Under the optimum conditions, the plots of the ECL versus the concentration of S2O 8 2? are linear in the range of 10?6 to 10?2 M with the detection limit of 3.98?×?10?7 M. Common anions have no effect on the ECL intensity of the [Ru(bpy)3]2+/S2O 8 2? system. Since CPEs have been widely used, CPEs with high hydrogen evolution potential are versatile platforms for electrochemical study and cathodic ECL study.  相似文献   

13.
《Analytical letters》2012,45(11):2311-2326
ABSTRACT

The effects of heteropoly acids and Triton X-100 on electrochemiluminescence (ECL) of Ru(bpy)3 2+ are investigated. Triton X-100 prevents the oxidation of oxalate and results in an increase of the ECL signal. H5SiW11VO40 prevents the direct oxidation of oxalate and makes the electrochemical behavior of Ru(bpy)3 2+ less reversible, which leads to a decrease of the ECL signal. In contrast, H3PMo12O40 has negligible effect on ECL intensity. Some possible reasons for the effects on the ECL of Ru(bpy)3 2+ are discussed based on the adsorption of SiW11VO40 5? on electrode surface and the ion association between SiW11VO40 5? and Ru(bpy)3 2+. The signal of ECL decreases linearly with the concentration of heteropoly acid in the range from 2x10?6 to 1x10?4 mol 1?1. The results indicate that ECL of Ru(bpy)3 2+ is a potential sensitive and selective detection method for heteropoly acids and hence for the elements comprised in them.  相似文献   

14.
《Electroanalysis》2005,17(7):589-598
The effect of 30 phenols and anilines on typical Ru complex electrochemiluminescence (ECL) was systematically investigated under different conditions. It was found that all the tested compounds showed an ECL inhibiting signal. The magnitude of ECL inhibition was related to the position of the substituting group in the benzene ring and decreased in the following order: meta‐>ortho‐>para‐. The oxidation potential of the tested compounds, the ECL spectra and UV‐visible absorption spectra of Ru(bpy) /tripropylamine (TPrA) in the presence of phenols and anilines, and the direct ECL between Ru(bpy) and phenols/aniline were studied. The mechanism of ECL inhibition has been proposed due to energy transfer from the excited state Ru(bpy) to a quinone or ketone or their polymer formed by electro‐oxidation of phenols and anilines. The potential of analytical application was explored by use of the inhibited ECL. The results demonstrate that numerous compounds are detectable with the detection limits in the range of 10?8–10?9 mol/L for Ru(bpy) /TPrA system and in the range of 10?6–10?7 mol/L for Ru(bpy) /C2O system, respectively.  相似文献   

15.
A novel electrogenerated chemiluminescence (ECL) sensor based on natural clay and ionic liquid was fabricated. Tris(2,2′‐bipyridine)ruthenium(II) (Ru(bpy)32+) was immobilized on natural clay surface through simple adsorption. An ECL sensor was prepared by mixing Ru(bpy)32+‐incorporated clay, graphite powder and an ionic liquid (1‐butyl‐3‐methylimidazolium hexafluorophosphate) as the binder. The electrochemical behavior and ECL of the immobilized Ru(bpy)32+ was investigated. It was observed that the ECL of immobilized Ru(bpy)32+ was activated by the ionic liquid. The proposed ECL sensor showed high sensitivity to tri‐n‐propylamine (TPrA) and the detection limit was found to be 20 pM. In addition, the ECL sensor displayed good stability for TPrA detection and long‐term storage stability.  相似文献   

16.
A simple, selective and sensitive “signal-on” electrogenerated chemiluminescence (ECL) biosensing method was developed for matrix metalloproteinase 2 (MMP-2). Ru(bpy)32+, gold nanoparticles (AuNPs) and Nafion were modified onto glassy carbon electrode (GCE) to form Ru(bpy)32+/AuNPs/Nafion/GCE as sensitive ECL platform and then ferrocene (Fc) labeled peptide was assembled onto the modified electrode to form ECL biosensing platform. The ECL intensity increased when the ECL biosensing electrode reacted with MMP-2 because of MMP-2-induced cleavage of Fc labeled peptide. The ECL method was applied to determine MMP-2 with detection limit of 0.3 ng/mL and one-step recognition, which is promising for point-of-care test of protease.  相似文献   

17.
《Electroanalysis》2003,15(9):803-811
Ru(II) tris‐bipyridine based ECL sensors were produced by embedding the complex inside silica glass thin films deposited via a sol‐gel dipping procedure on K‐glass conducing substrates. Films were prepared starting from a pre‐hydrolyzed ethanolic solution of Si(OC2H5)4 and Ru(bpy)3Cl2. Transparent, crack‐free and homogeneous reddish silica layers, having a thickness of 200±20 nm, were obtained. The films, either deposited at room temperature or thermally annealed at 100, 200 and 300 °C for 30 h, were structurally and chemically characterized. Ru(bpy)3Cl2 thermal stability was previously checked by thermogravimetric analysis (TGA). The films were investigated by X‐Ray photoelectron spectroscopy (XPS), secondary ion mass spectrometry (SIMS) and UV‐vis spectroscopy. XPS in‐depth profiles revealed a homogeneous distribution of the ruthenium complex inside the silica thin layers. SIMS data suggested that the embedded Ru(bpy)3Cl2 did not react with oxygen inside the oxygen‐rich silica matrix to give Ru‐O bonds. Electrochemical and ECL characterization of the thin film electrodes were made by means of cyclic voltammetry (CV) and controlled potential step experiments. The ECL sensor showed a diffusive redox behavior of the Ru(bpy)32+/Ru(bpy)33+ system. Light emission produced from the reaction between oxalic acid and the electrogenerated Ru(bpy)33+ was larger and stable when thermally treated electrodes were used after a suitable hydration period. The 300 °C treated sample was the best performing sensor both in terms of low complex leakage and sensitivity. Calibration plots relative to oxalic acid were obtained both in stationary and in flowing solutions in the concentration range 2×10?6?3×10?4 M. A linear behavior appeared in the former case, while in the latter a slight curvature was evident as a consequence of a finite diffusion time of the analyte inside the thin film. The signal repeatability, obtained by multiple 100 μL of 10?5 M oxalic acid injections in flowing solutions, was better than 4%. The obtained detection limit (computed as three times the standard deviation of the base‐line noise) was 10?6 M as oxalic acid.  相似文献   

18.
A approach was successfully employed for constructing a solid‐state electrochemiluminescence (ECL) immunosensor by layer‐by‐layer self‐assembly of multiwall carbon nanotubes (MWCNTs)‐Nafion composite film, Ru(bpy)32+/nano‐Pt aggregates (Ru‐PtNPs) and Pt nanoparticles (PtNPs). The influence of Pt nanoparticles on the ECL intensity was quantitatively evaluated by calculating the electroactive surface area of different electrodes with or without PtNPs to immobilize Ru(bpy)32+. The principle of ECL detection for target α‐fetoprotein antigen (AFP) was based on the increment of resistance after immunoreaction, which led to a decrease in ECL intensity. The linear response range was 0.01–10 ng mL?1 with the detection limit of 3.3 pg mL?1. The immunosensor exhibited advantages of simple preparation and operation, high sensitivity and good selectivity.  相似文献   

19.
Electrochemiluminescence (ECL) and electrochemistry are reported for a heterometallic soft salt, [Ru(dtbubpy)3][Ir(ppy)2(CN)2]2 ( [Ir][Ru][Ir] ), consisting of a 2:1 ratio of complementary charged Ru and Ir complexes possessing two different emission colors. The [Ru]2+ and [Ir]? moieties in the [Ir][Ru][Ir] greatly reduce the energy required to produce ECL. Though ECL intensity in the annihilation path was enhanced 18× relative to that of [Ru(bpy)3]2+, ECL in the co‐reactant path with tri‐n‐propylamine was enhanced a further 4×. Spooling spectroscopy gives insight into ECL mechanisms: the unique light emission at 634 nm is due to the [Ru]2+* excited state and no [Ir]?* was generated in either route. Overall, the soft salt system is anticipated to be attractive and suitable for the development of efficient and low‐energy‐cost ECL detection systems.  相似文献   

20.
A novel electrogenerated chemiluminescence (ECL) sensor based on Ru(bpy)32+‐doped titania (RuDT) nanoparticles dispersed in a perfluorosulfonated ionomer (Nafion) on a glassy carbon electrode (GCE) was developed in this paper. The electroactive component‐Ru(bpy)32+ was entrapped within the titania nanoparticles by the inverse microemulsion polymerization process that produced spherical sensors in the size region of 38±3 nm. The RuDT nanoparticles were characterized by electrochemical, transmission electron and scanning microscopy technology. The Ru(bpy)32+ encapsulation interior of the titania nanoparticles maintains its ECL efficiency and also reduces Ru(bpy)32+ leaching from the titania matrix when immersed in water due to the electrostatic interaction. This is the first attempt to prepare the RuDT nanoparticles and extend the application of electroactive component‐doped nanoparticles into the field of ECL. Since a large amount of Ru(bpy)32+ was immobilized three‐dimensionally on the electrode, the Ru(bpy)32+ ECL signal could be enhanced greatly, which finally resulted in the increased sensitivity. The ECL analytical performance of this ECL sensor for tripropylamine (TPA) was investigated in detail. This sensor shows a detection limit of 1 nmol/L for TPA. Furthermore, the present ECL sensor displays outstanding long‐term stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号