1.
The detection of volatile organic compounds (VOCs) in human breath can be useful for the clinical routine diagnosis of several diseases in a non-invasive manner. Traditional methods of breath analysis have some major technical problems and limitations. Membrane extraction with a sorbent interface (MESI), however, has many advantages over current methods, including good selectivity and sensitivity, and is well suited for breath analysis. The aim of this project was to develop a simple and reproducible sampling device and method based on the MESI system for breath analysis. The feasibility and validity of the MESI system was tested with real human breath samples. Internal standard calibration methods were used for the quantitative analysis of various breath samples. Calibration curves for some main components (target analytes such as acetone and pentane) were determined in the research. The optimized stripping-side and feeding-side gas velocities were determined. The use of breath CO2 as an internal standard for the analysis of breath VOCs is an effective method to solve the difficulties associated with variations in the target analyte concentrations in a sample, which are attributed to mass losses and different breathing patterns of different subjects. In this study, the concentration of breath acetone was successfully expressed normalized to CO2 as in the alveolar air. Breath acetone of healthy males and females profiled at different times of the day was plotted using the MESI system, and results were consistent with the literature. This technique can be used for monitoring breath acetone concentrations of diabetic patients and for applications with other biomarker monitoring.  相似文献   

2.
质子转移反应质谱在线检测痕量挥发性有机物*   总被引:1,自引:0,他引:1  
质子转移反应质谱是近年来兴起的一种痕量挥发性有机物在线检测技术,它可以在秒量级的时间内获得ppt量级的探测灵敏度,已经广泛的应用在环境污染监测、医学诊断、食品成分和质量检验等领域。本文介绍了它的工作原理和装置结构,给出了一些痕量挥发性有机物检测的例子,以及作者实验室使用该技术检测挥发性有机物的初步研究结果,并对该在线检测技术的发展方向进行了展望。  相似文献   

3.
Over the last few years, breath analysis for the routine monitoring of metabolic disorders has attracted a considerable amount of scientific interest, especially since breath sampling is a non-invasive technique, totally painless and agreeable to patients. The investigation of human breath samples with various analytical methods has shown a correlation between the concentration patterns of volatile organic compounds (VOCs) and the occurrence of certain diseases. It has been demonstrated that modern analytical instruments allow the determination of many compounds found in human breath both in normal and anomalous concentrations. The composition of exhaled breath in patients with, for example, lung cancer, inflammatory lung disease, hepatic or renal dysfunction and diabetes contains valuable information. Furthermore, the detection and quantification of oxidative stress, and its monitoring during surgery based on composition of exhaled breath, have made considerable progress. This paper gives an overview of the analytical techniques used for sample collection, preconcentration and analysis of human breath composition. The diagnostic potential of different disease-marking substances in human breath for a selection of diseases and the clinical applications of breath analysis are discussed.  相似文献   

4.
Human breath analysis is a powerful and especially a non-invasive technique for the monitoring and hopefully also for the diagnosis of respiratory diseases, including chronic obstructive pulmonary disease (COPD). The exhaled breath of 95 patients suffering COPD and of 35 healthy controls was investigated using an Ion Mobility Spectrometer (IMS) coupled to a Multi-Capillary Column (MCC) without any pre-separation or pre-enrichment. Starting with the results from a Mann–Whitney-Wilcoxon rank sum test to find analytes with the highest potential with respect to differentiation, box and whisker plots, metabolic maps and probability charts were introduced and compared. In addition, the sensitivity, specificity, positive and negative predictive values and the accuracy of the relation were also summarized. The findings were compared to the results of a principal component analysis. Finally, decision trees were introduced to visualize the interdependencies between the analytes and the classifications. The application of these biostatistical methods with simultaneous inclusion of several VOCs for disease classification by ion mobility spectrometry of human breath will provide much more information than using single peaks and single concentration dependencies for disease classification and discrimination of various groups. Towards the future application of potential biomarkers for clinical diagnostic procedures, complex analytical methods, such as ion mobility spectrometry, need statistical and bioinformatical tools which are simple in application, visualize the results and support decisions on the basis of the data obtained from measurements of analytes in exhaled human breath.  相似文献   

5.
The development of efficient protocols for cancer diagnosis remains highly challenging. An emerging approach relies on the detection in exhaled breath of volatile organic compounds (VOC) produced by tumours. In this context, described here is a novel strategy in which a VOC‐based probe is converted selectively in malignant tissues, by a tumour‐associated enzyme, for releasing the corresponding VOC. The latter is then detected in the exhaled breath as a tumour marker for cancer diagnosis. This approach allows the detection of several different tumours in mice, the monitoring of tumour growth and tumour response to chemotherapy. Thus, the concept of “induced volatolomics” provides a new way to explore biological processes using VOC‐based probes that could be adapted to many biomedical applications.  相似文献   

6.
曹雨虹  张明勇  刘敏  洪战英 《色谱》2019,37(3):265-273
神经递质(NTs)是神经传递的内源性化学信使,在大脑功能中发挥重要作用。中枢神经系统中神经递质浓度的变化与许多精神和生理疾病有关。神经递质的测定已成为疾病诊断和监测以及治疗干预的重要手段,有效的神经递质体内监测对于疾病诊疗乃至新药研发都至关重要。该文就近年来神经递质的检测方法,包括仪器检测法、电化学检测法以及一些新型检测方法等进行综述,并总结了目前神经递质检测在一些疾病研究中的应用进展。  相似文献   

7.
The detection of chemical compounds in exhaled human breath presents an opportunity to determine physiological state, diagnose disease or assess environmental exposure. Recent advancements in metabolomics research have led to improved capabilities to explore human metabolic profiles in breath. Despite some notable challenges in sampling and analysis, exhaled breath represents a desirable medium for metabolomics applications, foremost due to its non-invasive, convenient and practically limitless availability. Several breath-based tests that target either endogenous or exogenous gas-phase compounds are currently established and are in practical and/or clinical use. This review outlines the concept of breath analysis in the context of these unique tests and their applications. The respective breath biomarkers targeted in each test are discussed in relation to their physiological production in the human body and the development and implementation of the associated tests. The paper concludes with a brief insight into prospective tests and an outlook of the future direction of breath research.  相似文献   

8.
严枫  鞠熀先 《化学进展》2007,19(12):1852-1860
将分析化学与临床诊断相结合,发展临床检测新原理、新方法已成为人类健康的前沿领域之一,其中免疫分析,特别是多标志物同时免疫检测新方法的发展,与细胞检测已成为人们关注的课题。本文综述了近3年来这方面的研究进展, 并简要介绍了免分离、准无试剂和全无试剂安培免疫分析,空间分辨多通道安培芯片,底物区带分辨、通道分辨和通道-底物区带二维分辨化学发光免疫分析等多种免疫分析新概念,细胞检测与表面增殖监测、细胞毒效应研究与药敏检测新方法,对其在肿瘤临床诊断中的应用也作了总结。  相似文献   

9.
Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO3 nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (∼20 ppb) with short response (10–15 s) and recovery times (35–70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80–90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques.  相似文献   

10.
Rapid on-site detection of pathogenic bacteria with high sensitivity and specificity is becoming an urgent need in public health assurance, medical diagnostics, environmental monitoring, and food safety fields. Despite being reliable and widely used, the existing methods of bacteria detection are cumbersome and time-consuming, which is not conducive to field detection. Microfluidic lab-on-a-chip technology has provided a detective tool for various analytes, due to its miniaturization, portabilit...  相似文献   

11.
Process analysis using ion mobility spectrometry   总被引:7,自引:0,他引:7  
Ion mobility spectrometry, originally used to detect chemical warfare agents, explosives and illegal drugs, is now frequently applied in the field of process analytics. The method combines both high sensitivity (detection limits down to the ng to pg per liter and ppbv/pptv ranges) and relatively low technical expenditure with a high-speed data acquisition. In this paper, the working principles of IMS are summarized with respect to the advantages and disadvantages of the technique. Different ionization techniques, sample introduction methods and preseparation methods are considered. Proven applications of different types of ion mobility spectrometer (IMS) used at ISAS will be discussed in detail: monitoring of gas insulated substations, contamination in water, odoration of natural gas, human breath composition and metabolites of bacteria. The example applications discussed relate to purity (gas insulated substations), ecology (contamination of water resources), plants and person safety (odoration of natural gas), food quality control (molds and bacteria) and human health (breath analysis).  相似文献   

12.
免标记光学生物传感器研究进展   总被引:1,自引:0,他引:1  
张爱芹  王嫚  张辉  金军  申刚义 《化学通报》2018,81(1):21-28,44
免标记光学生物传感器因分析样品无需标记、强特异性、动态测量、无损检测、分析速度快等诸多优点,在化学、药学及生物等诸多领域中得到了快速发展和广泛应用。本文重点介绍了当前发展成熟且具代表性的四种免标记光学生物传感器,即表面等离子体共振传感器、光波导光模光谱传感器、椭圆偏振光学传感器以及反射干涉传感器,对每种传感器的原理结构、方法发展及在生化分析等相关领域中的最新应用进行了总结和论述;在此基础上,对它们各自的性能进行了优劣比较;最后对免标记光学生物传感器的发展前景进行了展望。  相似文献   

13.
Most of the current analytical methods depend largely on laboratory-based analytical techniques that require expensive and bullky equipment,potentially incur costly testing,and involve lengthy detection processes.With increasing requirements for point-of-care testing(POCT),more attention has been paid to miniaturized analytical devices.Miniaturized electrochemical(MEC)sensors,including different material-based MEC sensors(such as DNA-,paper-,and screen electrode-based),have been in strong demand in analytical science due to their easy operation,portability,high sensitivity,as well as their short analysis time.They have been applied for the detection of trace amounts of target through measuring changes in electrochemical signal,such as current,voltage,potential,or impedance,due to the oxidation/reduction of chemical/biological molecules with the help of electrodes and electrochemical units.MEC sensors present great potential for the detection of targets including small organic molecules,metal ions,and biomolecules.In recent years,MEC sensors have been broadly applied to POCT in various fields,including health care,food safety,and environmental monitoring,owing to the excellent advantages of electrochemical(EC)technologies.This review summarized the state-of-the-art advancements on various types of MEC sensors and their applications in POCT.Furthermore,the future perspectives,opportunities,and challenges in this field are also discussed.  相似文献   

14.
CE has been used widely as an analytical tool with high separation power taking advantage of size, charge-to-size ratio, or isoelectric point of various analytes. In combination with detection methods, such as UV absorption, electrochemical detection, fluorescence, or mass spectrometry (MS), it allows the separation and detection of inorganic and organic ions, as well as complex compounds, such as polypeptides, nucleic acids, including PCR amplicons from viruses or bacteria. Recent interest in identification of biomarkers of diseases using body fluids leads to development of CE-MS techniques. These applications allowed identification of new potential biomarkers for clinical diagnosis and monitoring of therapeutic interventions. In this report, we present a technical overview of various CE techniques and discuss their applications in clinical medicine.  相似文献   

15.
Detection of biomarkers for disease by noninvasive methods is critical for the early diagnosis and screening of disease, enabling prompt treatment. Breath biosensors are a viable option as the exhaled breath contains several biomarkers linked to lung cancer, oxidative stress, diabetes, and other diseases. Breath analysis has been achieved by advanced analytical techniques such as gas chromatography and infrared spectroscopy. However, electrochemical enzymatic breath biosensors offer a cost-effective, sensitive platform for biomarker detection without complex analysis and interpretation by trained laboratory personnel. This review aims to summarize recent advances in the field of electrochemical enzymatic breath biosensors and offer future opportunities from other applications of nonelectrochemical enzymatic breath biosensors.  相似文献   

16.
The current status of plasma-catalysis research and the associated possible applications are outlined. A basic explanation of plasma chemistry is given, which is then used as a foundation to indicate the research vector for the ongoing development of various applications. As an example of an environmental application, volatile organic compound decomposition using plasma-catalysis is discussed in depth, from the fundamental concept to the current industrial application status. As a potential application of plasma-catalysis towards the realization of a future “hydrogen society”, ammonia synthesis is discussed in terms of current social attitudes and regulations, along with historical developments. Additionally, up-to-date information on the fundamentals of the nonthermal plasma interaction with a catalyst is provided.  相似文献   

17.
In order to improve their bioapplications, inorganic nanoparticles (NPs) are usually functionalized with specific biomolecules. Peptides with short amino acid sequences have attracted great attention in the NP functionalization since they are easy to be synthesized on a large scale by the automatic synthesizer and can integrate various functionalities including specific biorecognition and therapeutic function into one sequence. Conjugation of peptides with NPs can generate novel theranostic/drug delivery nanosystems with active tumor targeting ability and efficient nanosensing platforms for sensitive detection of various analytes, such as heavy metallic ions and biomarkers. Massive studies demonstrate that applications of the peptide–NP bioconjugates can help to achieve the precise diagnosis and therapy of diseases. In particular, the peptide–NP bioconjugates show tremendous potential for development of effective anti-tumor nanomedicines. This review provides an overview of the effects of properties of peptide functionalized NPs on precise diagnostics and therapy of cancers through summarizing the recent publications on the applications of peptide–NP bioconjugates for biomarkers (antigens and enzymes) and carcinogens (e.g., heavy metallic ions) detection, drug delivery, and imaging-guided therapy. The current challenges and future prospects of the subject are also discussed.  相似文献   

18.
Respiratory illness demands pragmatic clinical monitoring and diagnosis to curb numerous fatal diseases in all aged groups. Due to the complicated instrumentation, long amplification periods, and restricted number of simultaneous detections, present clinically available multiplex diagnostic technologies are difficult to deploy the onsite diagnostic platforms. The futuristic assessment of medical diagnosis eases the respiratory monitoring using exhaled breath, due to the simple and comfort non-invasive detecting techniques. Carbon dioxide (CO2) stands as a promising biomarker and has been identified in exhaled breath samples that distinguish different respiratory issues. State-of-the-art CO2 gas sensing strategies are recognized with the growth of modern telecommunication technologies for real-time respiratory illness monitoring and diagnosis using exhaled breath. The presented article reviews the existing CO2 gas sensors and their developments towards medical applications. With that, the advancement of infrared (IR) CO2 gas sensors with distinguished light and sensing properties in detecting respiratory disorders are overviewed. The development of optimal CO2 gas sensing strategy incorporated with Internet of Things (IoT) technology is over-reviewed. The hurdles encountered in the existing research and future preference with real-time CO2 monitoring and diagnosing respiratory disorders with the advancement attained in IR sensing technology and IoT networking are highlighted.  相似文献   

19.
Chemiluminescence (CL) is an important method for quantification and analysis of various macromolecules. A wide range of CL agents such as luminol, hydrogen peroxide, fluorescein, dioxetanes and derivatives of oxalate, and acridinium dyes are used according to their biological specificity and utility. This review describes the application of luminol chemiluminescence (LCL) in forensic, biomedical, and clinical sciences. LCL is a very useful detection method due to its selectivity, simplicity, low cost, and high sensitivity. LCL has a dynamic range of applications, including quantification and detection of macro and micromolecules such as proteins, carbohydrates, DNA, and RNA. Luminol-based methods are used in environmental monitoring as biosensors, in the pharmaceutical industry for cellular localization and as biological tracers, and in reporter gene-based assays and several other immunoassays. Here, we also provide information about different compounds that may enhance or inhibit the LCL along with the effect of pH and concentration on LCL. This review covers most of the significant information related to the applications of luminol in different fields.  相似文献   

20.
Ion mobility spectrometry (IMS) is an analytical technique used for fast and sensitive detection of illegal substances in customs and airports, diagnosis of diseases through detection of metabolites in breath, fundamental studies in physics and chemistry, space exploration, and many more applications. Ion mobility spectrometry separates ions in the gas‐phase drifting under an electric field according to their size to charge ratio. Ion mobility spectrometry disadvantages are false positives that delay transportation, compromise patient's health and other negative issues when IMS is used for detection. To prevent false positives, IMS measures the ion mobilities in 2 different conditions, in pure buffer gas or when shift reagents (SRs) are introduced in this gas, providing 2 different characteristic properties of the ion and increasing the chances of right identification. Mobility shifts with the introduction of SRs in the buffer gas are due to clustering of analyte ions with SRs. Effective SRs are polar volatile compounds with free electron pairs with a tendency to form clusters with the analyte ion. Formation of clusters is favored by formation of stable analyte ion‐SR hydrogen bonds, high analytes' proton affinity, and low steric hindrance in the ion charge while stabilization of ion charge by resonance may disfavor it. Inductive effects and the number of adduction sites also affect cluster formation. The prediction of IMS separations of overlapping peaks is important because it simplifies a trial and error procedure. Doping experiments to simplify IMS spectra by changing the ion‐analyte reactions forming the so‐called alternative reactant ions are not considered in this review and techniques other than drift tube IMS are marginally covered.  相似文献   