首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Farrerol is a 2,3‐dihydro‐flavonoid isolated from rhododendron. In this study, a sensitive and selective ultra‐high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method was developed for the determination of farrerol in rat plasma. Liquid–liquid extraction by ethyl ether was used for sample preparation. Chromatographic separation was achieved on an Agilent UHPLC XDB‐C18 column (2.1 × 100 mm, 1.8 μm) with water and methanol (30:70, v /v) as the mobile phase. An electrospray source was applied and operated in negative ion mode; selection reaction monitoring was used for quantification using target fragment ions m/z 299 → 179 for farrerol and m/z 267 → 252 for internal standard. Calibration plots were linear in the range of 2.88–1440 ng/mL for farrerol in rat plasma. Intra‐ and inter‐day precisions were <11.6%, and the accuracy ranged from −13.9 to 11.9%. The UHPLC–MS/MS method was successfully applied in pharmacokinetics and bioavailability studies of farrerol in rats.  相似文献   

2.
In the current study, a simple, sensitive and rapid analytical method for the determination of dexamethasone was developed and applied to a pharmacokinetic study in nude mice. Using testosterone as an internal standard, a liquid chromatography–tandem mass spectrometry (LC‐MS/MS) approach after one‐step precipitation with acetonitrile was validated and used to determine the concentrations of dexamethasone in nude mice plasma. The method utilized a simple isocratic reverse phase separation over a Dionex C18 column with a mobile phase composed of acetonitrile–water (40:60, v/v). The analyte was detected by a triple quadrupole tandem mass spectrometer via electrospray and multiple reaction monitoring was employed to select both dexamethasone at m/z 393.0/147.1 and testosterone at m/z 289.5/97.3 in the positive ion mode. The calibration curves were linear (r >0.99) ranging from 2.5 to 500 ng/mL with a lower limit of quantitation of 2.5 ng/mL. The relative standard deviation ranged from 1.69 to 9.22% while the relative error ranged from ?1.92 to ?8.46%. This method was successfully applied to a preclinical pharmacokinetic study of dexamethasone and its pharmacokinetics was characterized by a two‐compartment model with first‐order absorption in female nude mice. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid and sensitive liquid chromatography–tandem mass spectrometric method (LC‐MS/MS) for the determination of bromotetrandrine in rat plasma has been developed and applied to pharmacokinetic study in Sprague–Dawley (SD) rats after a single oral administration. Sample preparation involves a liquid–liquid extraction with n‐hexane–dichlormethane (65:35, containing 1% 2‐propanol isopropyl alcohol, v/v). Bromotetrandrine and brodimoprim (internal standard, IS) were well separated by LC with a Dikma C18 column using methanol–ammonium formate aqueous solution (20 mm ) containing 0.5% formic acid (60:40, v/v) as mobile phase. Detection was performed on a triple quadrupole mass spectrometer in multiple reaction monitoring mode. The ionization was optimized using ESI(+) and selectivity was achieved using MS/MS analysis, m/z 703.0 → 461.0 and m/z 339.0 → 281.0 for bromotetrandrine and IS, respectively. The present method exhibited good linearity over the concentration range of 20–5000 ng/mL for bromotetrandrine in rat plasma with a lower limit of quantification of 20 ng/mL. The intra‐ and inter‐day precisions were 2.8–7.5% and 3.2–8.1%, and the intra‐ and inter‐day accuracy ranged from ?4.8 to 8.2% and ?5.6 to 6.2%, respectively. The method was successfully applied to a pharmacokinetic study after a single oral administration to SD rats with bromotetrandrine of 50 mg/kg. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
A reliable and sensitive ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed for the determination of zanubrutinib in the plasma of beagle dogs. The column used was an Acquity BEH C18 column (2.1 mm × 50 mm, 1.7 μm), maintained at 40°C with an injection volume of 2 μl. The gradient elution program was as follows: 0–1 min, 10–10% A; 1–1.1 min, 10–90% A; 1.1–2.1 min, 90–90% A; 2.1–2.2 min, 90–10% A; 2.2–3.0 min, 10–10% A. Mobile phase A was 0.1% formic acid, B was acetonitrile, and the total analysis time was 3 min. The mass spectrometry was performed in positive ion mode, and the scanning mode was multi-reaction monitoring mode with electrospray ionization as the ion source; m/z 472.2 → 455.01 for zanubrutinib and m/z 441.03 → 137.99 for ibrutinib (internal standard). The plasma samples were processed by protein precipitation. The standard curve showed good linearity (r2 = 0.999 8) in the range of 1.0–1,000 ng/ml (zanubrutinib) with a low limit of quantification of 1 ng/ml. Also, the intra-day and inter-day precision (RSD) was <5.88% and the accuracy (RE) ranged from −1.56 to 1.08%; the recoveries of zanubrutinib in beagle plasma ranged from 90.12 to 93.53% (RSD 1.67–6.42%) and the ME values of zanubrutinib were 98.70–101.06% (RSD 5.37–8.49%, n = 6). All values meet US Food and Drug Administration requirements. A rapid, highly selective and sensitive method for the determination of zanubrutinib concentration in plasma by UPLC–MS/MS was successfully developed. This method is suitable for pharmacokinetic studies in beagle dogs by following oral administration of zanubrutinib.  相似文献   

5.
A simple, practical, accurate and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and fully validated for the quantitation of guanfacine in beagle dog plasma. After protein precipitation by acetonitrile, the analytes were separated on a C18 chromatographic column by methanol and water containing 0.1% (v/v) formic acid with a gradient elution. The subsequent detection utilized a mass spectrometry under positive ion mode with multiple reaction monitoring of guanfacine and enalaprilat (internal standard) at m/z 246.2 → 159.0 and m/z 349.2 → 205.9, respectively. Good linearity was obtained over the concentration range of 0.1–20 ng/mL for guanfacine in dog plasma and the lower limit of quantification of this method was 0.1 ng/mL. The intra‐ and inter‐day precisions were <10.8% relative standard deviation with an accuracy of 92.9–108.4%. The matrix effects ranged from 89.4 to 100.7% and extraction recoveries were >90%. Stability studies showed that both analytes were stable during sample preparation and analysis. The established method was successfully applied to an in vivo pharmacokinetic study in beagle dogs after a single oral dose of 4 mg guanfacine extended‐release tablets. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for the simultaneous determination of metacavir and its two metabolites in rat plasma was developed and validated. Tinidazole was used as an internal standard and plasma samples were pretreated with one‐step liquid–liquid extraction. In addition, these analytes were separated using an isocratic mobile phase on a reverse‐phase C18 column and analyzed by MS in the selected reaction monitoring mode. The monitored precursor to product‐ion transitions for metacavir, 2′,3′‐dideoxyguanosine, O‐methylguanine and the internal standard were m/z 266.0 → 166.0, m/z 252.0 → 152.0, m/z 166.0 → 149.0 and m/z 248.0 → 202.0, respectively. The standard curves were found to be linear in the range of 1–1000 ng/mL for metacavir, 5–5000 ng/mL for 2′,3′‐dideoxyguanosine and 1–1000 ng/mL for O‐methylguanine in rat plasma. The precision and accuracy for both within‐ and between‐batch determination of all analytes ranged from 2.83 to 9.19% and from 95.86 to 111.27%, respectively. No significant matrix effect was observed. This developed method was successfully applied to an in vivo pharmacokinetic study after a single intravenous dose of 20 mg/kg metacavir in rats. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
Morinda officinalis is a famous traditional Chinese medicine containing iridoid glycoside compounds, such as monotropein and deacetylasperulosidic acid. The aim of the study was to develop a novel and sensitive liquid chromatography–tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of the two isomeric iridoid glycosides and then evaluate their pharmacokinetic properties in rats. Selected‐reaction monitoring mode was employed for quantification of two analytes in rat plasma. The calibration curves were linear over their respective concentration range with correlation coefficient >0.995 for both analytes. Precision for monotropein and deacetylasperulosidic acid ranged from 2.5 to 11.9% relative standard deviation, and the accuracy of two analytes was ?2.0–3.7 and ?6.4–10.7% relative error, respectively. This method was successfully applied in pharmacokinetic study after oral administration of M. officinalis extract in rats. The results provided a basis for further research on the bioactivity of M. officinalis. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
A simple and sensitive analytical method based on ultraperformance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) has been developed for determination of moclobemide in human brain cell monolayer as an in vitro model of blood–brain barrier. Brucine was employed as the internal standard. Moclobemide and internal standard were extracted from cell supernatant by ethyl acetate after alkalinizing with sodium hydroxide. The UPLC separation was performed on an Acquity UPLCTM BEH C18 column (50 × 2.1 mm, 1.7 µm, Waters, USA) with a mobile phase consisting of methanol–water (29.5:70.5, v/v); the water in the mobile phase contained 0.05% ammonium acetate and 0.1% formic acid. Detection of the analytes was achieved using positive ion electrospray via multiple reaction monitoring mode. The mass transitions were m/z 269.16 → 182.01 for moclobemide and m/z 395.24 → 324.15 for brucine. The extraction recovery was 83.0–83.4% and the lower limit of quantitation (LLOQ) was 1.0 ng/mL for moclobemide. The method was validated from LLOQ to 1980 ng/mL with a coefficient of determination greater than 0.999. Intra‐ and inter‐day accuracies of the method at three concentrations ranged from 89.1 to 100.9% for moclobemide with precision of 1.1–9.6%. This validated method was successfully applied to bidirectional transport study of moclobemide blood–brain barrier permeability. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
In the present study, an effective high performance liquid chromatography–tandem mass spectrometric (HPLC/MS/MS) method was developed and validated to simultaneously determine bupropion (BUP), quetiapine (QUE) and escitalopram (ESC) in human plasma using carbidopa as the internal standard. Chromatographic separation was achieved on a Waters Sun Fire C18 column using reversed‐phase chromatography. The MS/MS experiment was performed in positive ion multiple reaction monitoring mode to produce product ions of m/z 240.3 → 184.2 for BUP, 384.2 → 253.1 for QUE, 325.3 → 109.3 for ESC and 227.2 → 181.2 for the internal standard. The method showed good linearity (R2 ≥ 0.997), precision (relative standard deviation ≤7.5%), satisfactory intra‐ and interday accuracy (88.4–113.0%) and acceptable extraction recovery (87.2–115.0%), matrix effect (84.5.5?108.7%) and stability (92.3?103.5%). The method was successfully applied to determine the concentrations of BUP, QUE and ESC in human plasma samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the determination of GDC‐0425 concentrations in human plasma has been developed and validated. Supported liquid extraction was used to extract plasma samples (50 μL) and the resulting samples were analyzed using reverse‐phase chromatography and mass spectrometry coupled with a turbo‐ionspray interface. The mass analysis of GDC‐0425 was performed using multiple reaction monitoring transitions in positive ionization mode. The method was validated over the calibration curve range of 1.00–1000 ng/mL using linear regression and 1/x2 weighting. Within‐run relative standard deviation ranged from 0.8 to 5.1%, while between‐run RSD varied from 1.9 to 4.7% for QCs. The accuracy ranged from 90.0 to 101.0% of nominal for within‐run and from 94.0 to 100.0% of nominal for between‐run. Overall extraction recovery was 87.4% for GDC‐0425 and 87.9% for GDC‐0425‐d9. Stability of GDC‐0425 was established in human plasma for 374 days at ?20 and ?70 °C and established in reconstituted sample extracts for 88 h when stored at 2–8 °C. Stable‐labeled internal standard was used to minimize matrix effects. This assay was used to characterize the pharmacokinetics of GDC‐0425 in cancer patients.  相似文献   

11.
An LC‐MS/MS method for the determination of GDC‐0980 (apitolisib) concentrations in dog plasma has been developed and validated for the first time to support pre‐clinical drug development. Following protein precipitation with acetonitrile, the resulting samples were analyzed using reverse‐phase chromatography on a Metasil AQ column. The mass analysis was performed on a triple quadruple mass spectrometer coupled with an electrospray interface in positive ionization mode. The selected reaction monitoring transitions monitored were m/z 499.3 → 341.1 for GDC‐0980 and m/z 507.3 → 341.1 for IS. The method was validated over the calibration curve range 0.250–250 ng/mL with linear regression and 1/x2 weighting. Relative standard deviation (RSD) ranged from 0.0 to 10.9% and accuracy ranged from 93.4 to 113.6% of nominal. Stable‐labeled internal standard GDC‐0980‐d8 was used to minimize matrix effects. This assay was used for the measurement of GDC‐0980 dog plasma concentrations to determine toxicokinetic parameters after oral administration of GDC‐0980 (0.03, 0.1 and 0.3 mg/kg) to beagle dogs in a GLP toxicology study. Peak concentration ranged from 3.23 to 84.9 ng/mL. GDC‐0980 was rapidly absorbed with a mean time to peak concentration ranging from 1.3 to 2.4 h. Mean area under the concentration–time curve from 0 to 24 hours ranged from 54.4 to 542 ng h/mL. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
Celosin A (CA), a natural compound isolated from Celosia argentea L., has been shown significant hepatoprotective effect on AHNP‐induced liver injury. This study described a rapid and sensitive ultra‐high‐pressure liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) assay for determination of CA in rat plasma. Methanol‐mediated precipitation was used for sample pretreatment. Chromatographic separation was achieved on a T3 column with gradient elution using water and acetonitrile as mobile phase. Determination was obtained using an electrospray ionization source in negative selected reaction monitoring mode at the transitions of m/z 793.3 → m/z 661.2 and m/z 955.6 → m/z 793.2 for CA and IS, respectively. The assay was linear over the concentration range 0.25–2500 ng/mL (r > 0.995) with a lowest limit of quantification (LLOQ) of 0.25 ng/mL. The intra‐ and inter‐day precisions (RSD) were 1.65–9.84 and 2.46–13.49%, respectively, while accuracy (RR) ranged from 96.21 to 99.45%, respectively. The recovery ranged from 95.09 to 102.22% and the matrix effect from 98.29 to 100.13%. The analyte was stable under the tested storage conditions. The method has been successfully applied to a preclinical pharmacokinetic study in rats after a single intravenous (2 mg/kg) or oral (50 mg/kg) administration. The oral bioavailability of CA was ~1.94%; in addition, there was no difference between male and female rats. This is the first time of the use of an UHPLC–MS/MS method for determination of CA concentration in rat plasma and for evaluation of its pharmacokinetic behavior.  相似文献   

13.
In this work, a sensitive and selective ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method for determination of hupehenine in rat plasma was developed and validated. After addition of imperialine as an internal standard (IS), protein precipitation by acetonitrile–methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 416.3 → 98.0 for hupehenine, and m/z 430.3 → 138.2 for IS. Calibration plots were linear throughout the range 2–2000 ng/mL for hupehenine in rat plasma. Mean recoveries of hupehenine in rat plasma ranged from 92.5 to 97.3%. Relative standard deviations of intra‐day and inter‐day precision were both <6%. The accuracy of the method was between 92.7 and 107.4%. The method was successfully applied to a pharmacokinetic study of hupehenine after either oral or intravenous administration. For the first time, the bioavailability of hupehenine was reported as 13.4%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
Dexmedetomidine (Dex) is a selective central α2‐agonist with anesthetic properties and has been used in clinical practice for sedation in the intensive care unit (ICU) after operations. In this study, an analytical assay for the determination of Dex in a small amount of plasma was developed for the application to pediatric ICU trials. The quantification of Dex was constructed using the original stable isotope Dex‐d3 for electrospray ionization‐tandem mass spectrometry (ESI‐MS/MS) in the selected reaction monitoring mode. A rapid ultra‐performance liquid chromatography technique was adopted using ESI‐MS/MS with a runtime of 3 min. Efficacious concentration levels (50 pg/mL to 5 ng/mL) could be evaluated using a very small amount of plasma (10 μL) from patients. The lower limit of the quantification was 5 pg/mL in the plasma (100 µL). For sample preparation, a solid‐phase extraction was used along with the OASIS‐HLB cartridge type. Recovery values ranged from 98.8 to 100.3% for the intra‐ [relative standard deviation (RSD), 0.9–1.3%] and inter‐ (RSD, 0.9–1.5%) day assays. A stable test had recovery values that ranged from 97.8 to 99.7% with an RSD of 1.0–1.9% for the process/wet extract, bench‐top, freeze–thaw and long‐term tests. This method was used to measure the Dex levels in plasma from pediatric ICU patients. In the clinical ICU trial, the small amount of blood (approximate plasma volume, 200 μL) remaining from blood gas analysis was reused and targeted for the clinical analysis of Dex in plasma. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
A hydrophilic interaction chromatography‐tandem mass spectrometric method (HILIC/MS/MS) for the determination of irbesartan in human plasma was developed. Irbesartan and losartan (internal standard) were extracted from human plasma with ethyl acetate at acidic pH. The analytes were analyzed on a Luna HILIC column with the mobile phase of ACN–ammonium formate (50 mM, pH 6.5) (96:4, v/v) and detected by ESI MS/MS in the selected reaction monitoring mode. The standard curve was linear (r2 = 0.9981) over the concentration range of 10–2500 ng/mL and the lower LOQ was 10 ng/mL using 100 μL of plasma sample. The CV and relative error for intra‐ and interassay at four QC levels were 2.9 to 8.1% and –2.7 to 2.3%, respectively. There were less absolute and relative matrix effects for irbesartan and losartan. The present method was successfully applied to the pharmacokinetic study of irbesartan after oral dose of irbesartan (150 mg tablet) to male healthy volunteers.  相似文献   

16.
A novel, simple and rapid ultraperformance liquid chromatography/tandem mass spectrometry (UPLC‐MS/MS) assay was established for quantification of saxagliptin in rat plasma. Plasma samples were processed by liquid–liquid extraction with ethyl acetate and chromatographed on a C18 column (2.1 × 50 mm i.d., 1.7 µm). The mobile phase consisted of methanol and 0.1% formic acid (40:60, v/v). Multiple reaction monitoring transitions were performed for detection in positive‐ion mode with an electrospray ionization source. The calibration curve was linear over the concentration range of 0.5–100 ng/mL (R2 > 0.99). All accuracy values were between 90.62 and 105.60% relative error and the intra‐ and inter‐day precisions were less than 9.66% relative standard deviation. Extraction recovery was more than 81.01% and the matrix effect ranged from 90.27 to 109.15%. After validation, the method was applied to a pharmacokinetic study where healthy rats were orally given 0.5 mg/kg saxagliptin. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
This study established a rapid and reliable approach using liquid chromatography–tandem mass spectrometry for the simultaneous determination of cinnamic acid, vanillic acid and protocatechuic acid in rat plasma. This is the first report on a comparative pharmacokinetic study of dispensing granules and standard decoction of Cinnamomum cassia twigs in rats. After liquid–liquid extraction by ethyl acetate, the plasma samples were subjected to LC–MS/MS for multiple reaction monitoring. The standard curves showed good linear regression (r2 > 0.9991) in the range of 10.0–16000 ng/mL. The intra‐ and inter‐day accuracy and precision were found to be within 15% of the nominal concentration. The recoveries of the three phenolics ranged from 88.7 to 105.7%. Finally, this approach was successfully applied to pharmacokinetic analysis of the three phenolics after oral administration of standard decoction and dispensing granules of C. cassia twigs in rats. Although the values of AUC0–t of vanillic acid and protocatechuic acid in standard decoction group were larger than those of the dispensing granule group, no significant difference was observed for the two groups. Of note, the elimination rates of vanillic acid were slower in the standard decoction group than the dispensing granule group.  相似文献   

18.
Sparstolonin B (SsnB), a spontaneous isocoumarin compound isolated from the tuber of Scirpus yagara Ohwi. (Cyperaceae), possesses potent anti‐inflammatory and antitumor activity. In the present study, a rapid and simple UHPLC/MS/MS method for determination of SsnB in rat plasma was developed and validated. Plasma samples were pretreated by liquid–liquid extraction with ethyl acetate containing rhein as an internal standard and separated on a C18 column at 35 °C, with a gradient mobile phase consisting of acetonitrile and water containing 0.2% (v/v) formic acid within 2.1 min. MS/MS detection was accomplished in multiple reaction monitoring mode with negative electrospray ionization. The precursor–product ion transitions were m/z 266.9 [M–H]?m/z 211.0 for SsnB and m/z 283.2 [M–H]?m/z 239.0 for IS. The intra‐ and inter‐day precision (RSD) was <8.98% and the accuracy (RE) ranged from ?7.40 to 4.50%. The extraction recoveries ranged from 96.28 to 97.30%. The pharmacokinetic parameters were calculated using Win Nonlin53 software. The absolute bioavailability of SsnB was estimated to be 6.98%. The proposed method was successfully applied to a pharmacokinetic study of SsnB in rats after intravenous administration with a dose of 0.5 mg/kg and oral administration at a dose of 5 mg/kg. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
A simple and sensitive method based on ultra‐high‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) has been developed for the determination of TM‐2, which was a novel semi‐synthetic taxane derivative in beagle dog plasma. Cabazitaxel was chosen as internal standard. Following extraction by methyl tert‐butyl ether, the chromatographic separation was achieved on a Thermo Syncronis C18 column (50 × 2.1 mm, 1.7 µm) by gradient elution within a runtime of 3.5 min. The mobile phase consisted of (A) acetonitrile and (B) 2 mmol/L ammonium acetate in water. The detection was accomplished using positive ion electrospray ionization in multiple reaction monitoring mode. The MS/MS ion transitions were monitored at m/z 812.39 → 551.35 for TM‐2 and 836.36 → 555.26 for IS, respectively. The method was linear for TM‐2 (r = 0.9924) ranging from 2.5 to 1000 ng/mL. The intra‐day and inter‐day precisions (relative standard deviation) were within 8.0 and 17.6%, respectively, and the accuracy (relative error) was less than 2.3%. The extraction recovery ranged from 83.1 to 97.1%. The reliable method was successfully applied to a pharmacokinetic study of TM‐2 in beagle dogs after intravenous drip with different doses of 0.6, 1.2, and 2.4 mg/kg, respectively. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

20.
A simple, sensitive and specific UHPLC–MS/MS method for quantification of plantagoguanidinic acid (PGA) in rat plasma was applied to investigate the pharmacokinetic behavior in vivo , using protopine as internal standard. The chromatography was separated on a Phenomenex® Luna‐C18 column (2.1 × 150 mm, 3.0 μm) within 7.0 min using a mobile phase consisting of acetonitrile–0.1% formic acid solution under gradient elution at a flow rate of 0.4 mL/min. Prepared samples were monitored by multiple reaction monitoring mode, with the target fragmentions m/z 226.2 → 84.2 for PGA and m/z 354.2 → 188.9 for IS in positive electrospray ionization. The calibration curve of PGA was linear throughout the range 1–1000 ng/mL (r = 0.9962). The lower limit of quantitation in plasma for PGA was 0.1 ng/mL, and the recovery was >88.6%. Intra‐ and interday accuracy ranged from −8.6 to 4.9%. Furthermore, this validated method was successfully used for a pre‐clinical pharmacokinetic study of PGA at a single dose of 20 and 5 mg/kg in rats via oral and intravenous administration. The study showed that PGA was absorpted rapidly and eliminated gradually with a greater absolute oral bioavailability of 70.1% in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号