首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 875 毫秒
1.
Selected ion flow tube mass spectrometry (SIFT-MS) has been used to analyse on-line and in real time the exhaust gas emissions from a Caterpillar 3304 diesel engine under different conditions of load (idle and 50% of rated load) and speed (910, 1500 and 2200 rpm) using three types of fuel: an ultra-low-sulphur diesel, a rapeseed methyl ester and gas oil. SIFT-MS analyses of the alkanes, alkenes and aromatic hydrocarbons in the headspace of these fuels were also performed, but the headspace of the rapeseed methyl ester consists mainly of methanol and a compound with the molecular formula C4H8O. The exhaust gases were analysed for NO and NO2 using O2+* reagent ions and for HNO2 using H3O+ reagent ions. The following aldehydes and ketones in the exhaust gases were quantified by using the combination of H3O+ and NO+ reagent ions: formaldehyde, acetaldehyde, propenal, propanal, acetone, butanal, pentanal, butanone and pentanone. Formaldehyde, acetaldehyde and pentenal, all known respiratory irritants associated with sensitisation to asthma of workers exposed to diesel exhaust, are variously present within the range 100-2000 ppb. Hydrocarbons in the exhaust gases accessible to SIFT-MS analyses were also quantified as total concentrations of the various isomers of C3H4, C3H6, C4H6, C5H8, C5H10, C6H8, C6H10, C7H14, C6H6, C7H8, C8H10 and C9H12.  相似文献   

2.
用选择离子流动管质谱测定汽油和柴油蒸汽成分   总被引:2,自引:0,他引:2  
采用选择离子流动管质谱(SIFT/MS)装置,以H30^ 、N0^ 为初始离子对汽油和柴油蒸汽进行了研究,质谱分析表明,汽油和柴油主要由C—H化合物组成,包括烷烃、环烷烃、烯烃、炔烃、二烯烃以及芳香烃。在这几种成分中,烷烃都占有最大的比例;汽油蒸汽和柴油蒸汽最大的区别是柴油蒸汽中长链大分子的挥发性C—H化合物所占的比例远远高于汽油蒸汽。文中还给出了以H30^ 、N0^ 为初始离子所得到的汽油蒸汽的质谱图,以及汽油、柴油蒸汽中各种成分的定量分析结果。  相似文献   

3.
The value of the gas chromatography (GC) and selected ion flow tube mass spectrometry (SIFT-MS) combination for the analysis of trace gases is demonstrated by the quantification of acetone in air samples using the three precursor ions available to SIFT-MS, viz. H3O+, NO+ and O2+, and by the separation of the isomers 1-propanol and 2-propanol, and their analysis using H3O+ precursor ions. It is shown that the GC/SIFT-MS combination allows for accurate trace gas quantification obviating the regular, time-consuming calibrations that are usually required for the more commonly used detectors of GC systems, and the positive identification of isomers in mixtures that is often challenging using SIFT-MS alone. Thus, the GC/SIFT-MS combination paves the way to more confident analyses of complex mixtures such as exhaled breath.  相似文献   

4.
A selected ion flow tube (SIFT) experimental investigation has been carried out of the reactions of H3O+, NO+ and O2+ with NO, NO2, N2O and HNO2, in order to obtain the essential kinetic data for the analyses of these compounds in air using selected ion flow tube mass spectrometry (SIFT-MS). These investigations show that NO+ ions do not react at a significant rate with any of these NOx compounds and that H3O+ ions react only with HNO2 (product ions H2NO2+ (75%) and NO+ (25%)). O2+ ions react with NO (product ion NO+), NO2 (product ion NO2+) and HNO2 (product ions NO+ (75%), NO2+ (25%)), but not with N2O. We conclude that both NO and NO2 can be accurately quantified in air using only O2+ precursor ions and SIFT-MS when HNO2 is not present. However, when HNO2 is present it invariably co-exists with both NO and NO2 and then both H3O+ and O2+ precursor ions are needed to determine the partial pressures of NO, NO2 and HNO2 in the air mixture. We also conclude that currently N2O cannot be analysed in air using SIFT-MS.  相似文献   

5.
Selected ion flow tube mass spectrometry, (SIFT-MS), is a technique for simultaneous real-time quantification of several trace gases in air and exhaled breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas, using H(3)O(+), NO(+) and O(2)(+) reagent (precursor ions). Reactions between the precursor ions and the trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream mass spectrometer. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT-MS down to parts-per-billion (ppb) levels, obviating sample collection into bags or onto traps. Calibration using chemical standards is not required, as the concentrations are calculated using the known reaction rate constants and measured flow rates and pressures. SIFT-MS has been used for many pilot investigations in several areas of research, especially as a non-invasive breath analysis tool to investigate physiological processes in humans and animals, for clinical diagnosis and for therapeutic monitoring. Examples of the results obtained from several such studies are outlined to demonstrate the potential of SIFT-MS for trace gas analysis of air, exhaled breath and the headspace above liquids.  相似文献   

6.
A selected ion flow tube mass spectrometry (SIFT-MS) study of the reactions of H3O+, NO+ and O2+* ions with the ketones (M) 2-heptanone, 2-octanone, 2-nonanone, 2-undecanone and 2-aminoacetophenone has been conducted in preparation for studies of volatile emissions from bacteria. The H3O+ reactions all proceed rapidly via exothermic proton transfer, producing only MH+ ions that form their monohydrates when water vapour is present in the helium carrier gas. The O2+* reactions proceed rapidly via dissociative charge transfer producing parent cations M+* and some fragment ions. The NO+ reactions form the NO+M adduct ions at rates which are dependent on the pressure of the helium carrier gas. Combining the present NO+ kinetic data with those available from previous SIFT studies, the phenomenon of charge transfer complexing is clearly demonstrated. This results in adduct formation in these NO+/ketone reactions at or near the collisional rate. SIFT-MS spectra are presented to illustrate the simplicity of SIFT-MS analysis of ketones using both H3O+ and NO+ precursor ions.  相似文献   

7.
We have carried out a study of the reactions of H(3)O(+), NO(+) and O(2) (+), the commonly used precursor ions for selected ion flow tube mass spectrometry (SIFT-MS), with three anaesthetic gases, halothane, isoflurane and sevoflurane. The motivation for this study was to provide the necessary kinetic data that would allow the quantification of these anaesthetic gases in operating theatre air and in the breath of theatre staff and post-operative patients. A clear negative result from these experiments is that NO(+), although undergoing the simplest chemistry, is unsuitable for this SIFT-MS application. However, although the ion chemistry of H(3)O(+) and O(2) (+) with these compounds is very complex, there being several product ions in each reaction, many of which react rapidly with water molecules, monitor ions have been identified for all three anaesthetic gases when using H(3)O(+) and O(2) (+) as precursor ions. The detailed ion chemistry is discussed and the specific monitor ions are indicated. Hence, the feasibility of on-line breath monitoring is demonstrated by simple examples. These studies have opened the way to measurements in the clinical environment.  相似文献   

8.
We describe how selected ion flow tube mass spectrometry (SIFT-MS) can be used to determine the absolute humidity of air, breath and liquid headspace samples. This involves the determination of the relative count rates of the H3O+ ions and those H3O+.(H2O)(1,2,3) hydrate ions that inevitably form in the helium carrier gas when humid samples are being analysed by SIFT-MS using H3O+ precursor ions. This requires an understanding of the kinetics of hydrated hydronium ion formation, the involvement of mass discrimination in the analytical quadrupole mass spectrometer and the decreased diffusive loss of the heavier hydrates along the flow tube. Thus, we show that the humidity of breath and liquid headspace samples, typically at the few percent level, can be directly obtained on-line to the SIFT-MS instrument along with the concentrations of trace gases, which are present at much lower levels. We emphasise the value of parallel humidity measurements in ensuring good real-time sampling of breath and liquid headspace and the value of such measurements to trace gas analysis using SIFT-MS.  相似文献   

9.
选择离子流动管质谱及其在痕量气体分析中的应用   总被引:7,自引:1,他引:6  
王天舒 《分析化学》2005,33(6):887-893
选择离子流动管质谱(SIFT-MS)结合流动管技术、化学电离和质谱,有选择地使用F13O^ 、NO^ 和O2^ 初始离子,可在几秒之内对空气、呼吸气体和液表蒸气中的痕量气(如乙醇、乙醛、丙酮、氨和2-甲基丁二烯等,行多组分实时在线分析。介绍了选择离子流动管(SIFT)技术、SIFT-MS的分析方法及其物理和离子化学基础、SIFT-MS在不同领域的痕量气体分析中的应用。  相似文献   

10.
Selected ion flow tube mass spectrometry, (SIFT-MS), involves the partial conversion of mass-selected precursor ions to product ions in their reactions with the trace gases in an air sample that is introduced into helium carrier gas in a flow tube. The precursor and product ions are then detected and counted by a downstream quadrupole mass spectrometer. Quantification of particular trace gases is thus achieved from the ratio of the total count rate of the product ions to that for the precursor ions. However, it is important to appreciate that in this ion chemistry the light precursor ions (usually H3O+ ions) are invariably converted to heavier product ions. Hence, the product ions diffuse to the flow tube walls more slowly and thus they are more efficiently transported to the downstream mass spectrometer sampling orifice. This phenomenon we refer to as diffusion enhancement. Further, it is a well-known fact that discrimination can occur against ions of large mass-to-charge ratio, (m/z), in quadrupole mass spectrometers. If not accounted for, diffusion enhancement usually results in erroneously high trace gas concentrations and mass discrimination results in erroneously low concentrations. In this experimental investigation, we show how both these counteracting effects can be accounted for to increase the accuracy of SIFT-MS quantification. This is achieved by relating the currents of ions of various m/z that arrive at the downstream mass spectrometer sampling orifice disc to their count rates at the ion detector after mass analysis. Thus, both diffusion enhancement and mass discrimination are parameterized as a function of m/z and these are combined to provide an overall discrimination factor for the particular analytical instrument.  相似文献   

11.
Sulfur impact on diesel emission control- A review   总被引:3,自引:0,他引:3  
The effect of sulfur on diesel emission control is reviewed in this paper. Diesel exhaust differs from that of petrol engine exhaust in two major characteristics. Firstly, diesel exhaust contains a far higher amount of particulate matter, and secondly, the exhaust is far leaner, that is, far more oxidizing than a typical exhaust from petrol engines. Under these conditions, the conventional three-way catalysts are not effective in reducing NOx . Emission from diesel engines is a complex phenomenon. The composition, the properties and the amount of these emissions depend on strictly technical parameters such as engine design and engine operation characteristics and on fuel and lube oil composition. Diesel fuel contains a small amount of sulfur which has an adverse effect even on the raw particulate emissions. The investigations on the effect of sulfur on hydrocarbons, CO and NOx abatement in diesel exhaust gas is reviewed together with the newest technologies to avoid catalyst deactivation by unwanted SO2 reactions.  相似文献   

12.
We report the results of a study of the reactions of H(3)O(+), NO(+) and O(2)(+.) ions with H(2)S. This study was undertaken to provide a thorough understanding of the ion chemistry required for accurate quantification of H(2)S in humid air by selected ion flow tube mass spectrometry (SIFT-MS). It shows that slow reactions occur between H(3)S(+), the primary product ions of the H(3)O(+)/H(2)S reaction, and the abundant H(2)O molecules present in humid air and breath. These reactions disturb somewhat the quantification of H(2)S by this analytical method, but the kinetic data obtained in this study facilitate precise quantification of H(2)S in humid air. This study also shows that NO(+) does not react with H(2)S, and that O(2)(+.) does react rapidly with H(2)S, but the product H(2)S(+.) ions react rapidly with H(2)O. Thus, NO(+) and O(2)(+.) cannot be used as precursor ion for analysis of H(2)S in moist air by SIFT-MS. A sample SIFT mass spectrum is shown from which H(2)S and several other volatile compounds have been quantified in a sample of cow rumen gas.  相似文献   

13.
We report a fast, sensitive, real-time method to measure monobromamine, monochloramine and dichloramine using selected ion flow tube mass spectrometry (SIFT-MS). Relative rate coefficients and product distributions are reported for the reagent ions H3O+ and O2 +. Rapid reactions with the haloamines were observed with H3O+ and O2 + but no fast reaction was found with NO+. A slow reaction between NO+ and dichloramine was observed. We demonstrate the feasibility of determining these compounds in a single human breath for which the limit of detection is approaching 10 parts per billion (ppb). We also report preliminary measurements of these compounds in the breath of individuals where the concentrations of bromamine and chloramine ranged from 10 to 150 ppb.  相似文献   

14.
Smith D  Spaněl P 《The Analyst》2011,136(10):2009-2032
The topic of ambient gas analysis has been rapidly developed in the last few years with the evolution of the exciting new techniques such as DESI, DART and EESI. The essential feature of all is that analysis of trace gases can be accomplished either in the gas phase or those released from surfaces, crucially avoiding sample collection or modification. In this regard, selected ion flow tube mass spectrometry, SIFT-MS, also performs ambient analyses both accurately and rapidly. In this focused review we describe the underlying ion chemistry underpinning SIFT-MS through a discourse on the reactions of different classes of organic and inorganic molecules with H(3)O(+), NO(+) and O(2)(+)˙ studied using the SIFT technique. Rate coefficients and ion products of these reactions facilitate absolute SIFT-MS analyses and can also be useful for the interpretation of data obtained by the other ambient analysis methods mentioned above. The essential physics and flow dynamics of SIFT-MS are described that, together with the reaction kinetics, allow SIFT-MS to perform absolute ambient analyses of trace compounds in humid atmospheric air, exhaled breath and the headspace of aqueous liquids. Several areas of research that, through pilot experiments, are seen to benefit from ambient gas analysis using SIFT-MS are briefly reviewed. Special attention is given to exhaled breath and urine headspace analysis directed towards clinical diagnosis and therapeutic monitoring, and some other areas researched using SIFT-MS are summarised. Finally, extensions to current areas of application and indications of other directions in which SIFT-MS can be exploited for ambient analysis are alluded to.  相似文献   

15.
Selected ion flow tube mass spectrometry (SIFT-MS) has been employed to study the ion-molecule reactions of 17 alkyl esters reacting with the common SIFT-MS reagent ions, H3O+, H3O+.nH2O (n = 1, 2, 3), NO+, and O2+. The majority of reactions were observed to proceed at or near collision rate, with the exception of H3O+.3H2O, which was found to be slow for 8 of 17 alkyl esters. Unexpected product ions in the form of the parent carboxylic acid cation were observed to arise from the H3O+ and NO+ reactions of some alkyl esters. The observed reactions have been probed by the ab initio CBS-4M and G2(MP2,SVP) methods. The postulated reaction pathway involves a 1,5 H atom migration from a beta-carbon onto the carbonyl oxygen.  相似文献   

16.
Basil (Ocimum basilicum) is an important flavourant plant which constitutes the major ingredient of the pasta sauce 'Pesto alla Genovese'. The characteristic smell of basil stems mainly from a handful of terpenoids (methyl cinnamate, eucalyptol, linalool and estragole), the concentration of which varies according to basil cultivars. The simple and rapid analysis of the terpenoid constituents of basil would be useful as a means to optimise harvesting times and to act as a quality control process for basil-containing foodstuffs. Classical analytical techniques such as gas chromatography/mass spectrometry (GC/MS) are, however, slow, technically demanding and therefore less suitable for routine analysis. A new chemical ionisation technique which allows real-time quantification of traces gases, Selected Ion Flow Tube Mass Spectrometry (SIFT-MS), was therefore utilised to determine its usefulness for the assay of terpenoid concentrations in basil and pesto sauce headspace. Trace gas analysis was performed using the NO(+) precursor ion which minimised interference from other compounds. Character-impacting compound concentration was measured in basil headspace with good reproducibility and statistically significant differences were observed between cultivars. Quantification of linalool in pesto sauce headspace proved more difficult due to the presence of interfering compounds. This was resolved by careful selection of reaction product ions which allowed us to detect differences between various commercial brands of pesto. We conclude that SIFT-MS may be a valid tool for the fast and reproducible analysis of flavourant terpenoids in basil and basil-derived foodstuffs.  相似文献   

17.
Nitric oxide reagent gas has been found to improve the sensitivty and robustness of the atmospheric pressure corona discharge ionization (APCDI) process. Sensitivity has been increased by a factor of 20-100, depending on the compound, over APCDI without nitric oxide. The robustness (defined as the sensitivity to matrix interferences) of APCDI in the presence of water has been improved by a factor of 3 over normal APCDI. These improvements are due in part to a modification of the commercial inlet system and ionization chamber that allows the chamber and sample gases to be heated to 100 and 350 °C, respectively. Nitric oxide was chosen as the reagent gas because of the variety and selectivity of its interaction with hydrocarbons with differing functional groups. Product ions of nitric oxide ionization and their subsequent tandem mass spectra are presented and discussed for selected alkanes, alkenes, alkylbenzenes, alcohols, aldehydes, and an ether. A tandem mass spectrometry (unique parent ion-daughter ion transition) method was developed to quantify componds of specific interest in vehicle emissions. The absolute sensitivty for these compounds, under ideal conditions, was determined and ranges from 0.006 ppb for xylene (most sensitive) to 80 ppb for C8 (or larger) normal alkanes. Routine sensitivity for real-world samples was in the single parts per billion range for aromatic and olefinic species. Potential applications include the real-time, on-line monitoring of selected hydrocarbons in automobile exhaust.  相似文献   

18.
Selected ion flow tube mass spectrometry (SIFT-MS) detects and quantifies in real time the trace gases, M, in air/breath samples introduced directly into a flow tube. Inevitably, relatively large partial pressures of water vapour are introduced with the sample and the water molecules become involved in the ion chemistry on which this analytical technique depends. When H(3)O(+) ions are used as the precursors for chemical ionisation and SIFT mass spectrometric analyses of M, they generally result in the formation of MH(+) ions. Also, when water vapour is present the H(3)O(+) ions are partially converted to hydrated hydronium ions, H(3)O(+).(H(2)O)(1,2,3). The latter may act as precursor ions and produce new product ions like MH(+).(H(2)O)(1,2,3) via ligand switching and association reactions. This ion chemistry and the product ions that result from it must be accounted for in accurate analyses by SIFT-MS. In this paper we describe the results of a detailed SIFT study of the reactions involved in the quantification of acetone, ethyl acetate, diethyl ether, methanol, ethanol, ammonia and methyl cyanide by SIFT-MS in the presence of water vapour. This study was undertaken to provide the essential data that allows more accurate analyses of moist air and breath by SIFT-MS to be achieved. It is shown using our standard analysis procedure that the error of SIFT-MS quantification caused by the presence of water vapour is typically 15%. An improved analysis procedure is then presented that is shown to reduce this error to typically 2%. Additionally, some fundamental data have been obtained on the association reactions of protonated organic molecules, MH(+) ions, with water molecules forming MH(+).H(2)O monohydrate ions. For some types of M, reaction sequences occur that lead to the formation of dihydrate and trihydrate ions.  相似文献   

19.
A new method has been developed for the determination of the isotope abundance ratios of deuterium, D, and oxygen-18, 18O, in water vapor (and water) using selected ion flow tube mass spectrometry (SIFT-MS). H3O+ ions are injected into the helium carrier gas where they associate with the H2O and HDO molecules in a sample of water introduced into the carrier gas. The D and 18O contents of the product cluster ions H8DO4+ and H9(18)OO3+ at m/e = 74 and 75, respectively, are determined by reference to the majority cluster ion H9O4+ at m/e = 73. Allowance is made for the contribution of the H8(17)OO3+ ions to the m/z = 74 ions. Absolute isotopic ratios are measured within seconds without the need for precalibration of the SIFT-MS instrument, currently to an accuracy of better than 2%.  相似文献   

20.
采用选择离子流动管质谱(SIFT-MS)法,顶空取样后,以H3O+,NO+或O2+为初始离子,定量分析了17种大蒜酶解液挥发性有机硫化合物。结果表明:有机硫化合物主要为二烯丙基硫醚、甲基烯丙基硫醚、硫代亚磺酸酯和硫醇,其中二烯丙基二硫醚浓度为137 g/m3,二烯丙基三硫醚浓度为13.4 g/m3,甲基烯丙基二硫醚浓度为8.98 g/m3,它们分别占17种有机硫化合物总含量的77.3%,7.58%和5.08%(相对含量);本研究采用顶空取样方法测出大蒜素的浓度为5.63 g/m3,相对含量为3.20%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号