首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 578 毫秒
1.
For two-dimensional reversed-phase liquid chromatography–gas chromatography (2D RPLC–GC), a specially-designed needle packed with a polymer-coated fibrous stationary phase was introduced as a novel interface. The bundle of synthetic fibers coated with polydimethylsiloxane (PDMS) was packed into the head section of the needle, and served as the extraction medium. Using the post-column dilution of the LC eluent by water and subsequent extraction with the needle interface, the analyte was successfully concentrated to the PDMS phase on the fibrous support in the needle. The concentrated analytes were directly injected to GC system by inserting the needle to a heated GC injector. 2D separations of aliphatic and aromatic hydrocarbons, and also kerosene-extract were performed with the off-line RPLC–GC system interfaced by the needle extractor. The results suggested that the fiber-packed needle interface could be one of the simple and effective approaches to develop an on-line coupled LC–GC system.  相似文献   

2.
天然产物研究一直是植物学、化学和药学的重要研究领域.通过从天然产物中寻找生物活性成分和先导物是创制新药的有效途径之一.有效成分的提取是天然产物研究中最基本和最关键的环节.超临界流体萃取(Supercritical fluid extraction,简称SFE)是近年来发展较快的一种新型样品提取技术.超临界CO2作为最常用的萃取剂已被用于天然药物中非极性和弱极性有效成分的提取,尤其是挥发性和热敏性的物质.此外,通过加入适当的添加剂还可有效地萃取极性化合物,和传统的化学方法相比,  相似文献   

3.
建立了以香烟过滤嘴纤维作吸附剂,在线固相萃取-高效液相色谱(SPE—HPLC)测定水中邻硝基苯甲酸、对硝基苯胺、邻硝基苯酚、3-氯硝基苯四种硝基类化合物的方法。邻硝基苯甲酸、对硝基苯胺、邻硝基苯酚、3-氯硝基苯分别在0.006~4.80、0.003~2.40、0.002~1.60、0.002~1.60mg/L范围内峰面积与浓度呈线性关系,相关系数分别为0.9994、0.9996、0.9997和0.9996;检出限(S/N=3)分别为1.0、0.8、0.6,0.6μg/L;富集倍数分别为28.2、176.6、172.1、153.3。该法用于河水中四种硝基类化合物的测定,回收率为85.41%~116.44%,相对标准偏差在1.1%~5.4%范围内。  相似文献   

4.
《Analytical letters》2012,45(15):2349-2355
An on-line SPE-HPLC method using a cigarette filter as the sorbent was developed and applied to analyze the aniline derivatives in water samples. A preconcentration column packed with cigarette filters was used to replace a conventional sample loop on the injector valve of an HPLC for on-line SPE. With the consumption of a 7.5 mL sample solution, the enhancement factors ranged from 287 to 349 in comparison with direct injections of 20 μL sample solution. The detection limits (S/N = 3) for preconcentration of 7.5 mL of sample solution ranged from 0.27 to 5.46 μg/L at a sample throughput of 6 samples per hour.  相似文献   

5.
A new analytical technique combining on-line supercritical fluid chromatography with capillary gas chromatography has been developed. The supercritical fluid sample effluent is decompressed through a restrictor directly into a conventional capillary gas chromatographic injection port. This technique allows for not only direct (100%) sample transfer from the supercritical fluid chromatograph to the gas chromatograph but also for selective or multi-step heartcutting of various sample peaks as they elute from the supercritical fluid chromatograph. Heartcut times are determined by monitoring the responses from the flame ionization or ultraviolet absorbance detectors on the supercritical fluid chromatograph. This report describes the operational setup and provides the results of heartcut reproducibility experiments using normal hydrocarbon and aromatic test mixtures. Results from studies where operational parameters were varied, such as GC injector temperature, will also be provided. The potential usefulness of this new technique for selective heartcutting will also be demonstrated using complex hydrocarbon streams.  相似文献   

6.
并行捕集柱SFE-HPLC在线联用系统的构建及应用   总被引:1,自引:0,他引:1  
在前期研究的基础上, 发展了采用自动十通阀/并行捕集柱接口构建了SFE和HPLC在线联用的新装置, 并利用该系统对灵芝子实体的超临界萃取过程进行实时监测.  相似文献   

7.
The popular solid phase micro extraction (SPME) device and method is compared with SnifProbe (Gordin and Amirav in J Chromatogr A 903:155–172, 2000) in their application for coffee aroma sampling for its analysis. The main difference between SPME and SnifProbe is in the relative motion of the sampled air. While SPME is based on static air sampling and the achievement of equilibrium, SnifProbe is based on active air pumping through the adsorption trap. A second important difference concerns the sample introduction into the GC injector for its intra injector thermal desorption. SPME is based on the use of a special syringe for sample introduction without any change to the injector, while SnifProbe requires a ChromatoProbe for sample introduction. We found that as a result of these differences, while SnifProbe provides a more faithful (representative) headspace and aroma sample collection, SPME is characterized by major compound dependent sample bias. In addition, SnifProbe enabled much faster sample collection than SPME. Since SnifProbe uses the ChromatoProbe for sample introduction into the GC, bigger sample collection/trapping devices such as silicone tubing can be used, and as a result, over ten times superior SnifProbe sensitivity (versus SPME) was demonstrated. Additional SnifProbe and SPME features are compared and discussed.  相似文献   

8.
In this study, a sorbent was immobilized inside a needle resulting in the development of a needle trap (NT) device. This device was applied to extract organic components from gaseous samples and to introduce an enriched mixture into a conventional gas chromatography (GC) injector. Construction of this simple and integrated sampling/extraction/sample introduction device was optimized by considering different ways to immobilize a sorbent in the needle, packing single and multiple-layer sorbent beds, and applying different desorption strategies into the GC injector. A carrier gas system was modified to minimize the carryover for the needle trap with a sealed tip (NT-1), and a narrow-neckliner was used for the blunt-tip needle trap (NT-2). Breakthrough in the device was investigated by connecting two NT-2 devices in series. The needle trap performed very well as an exhaustive spot sampler, as well as in a time-weighted average (TWA) operation. The linear velocity of the mobile phase has no influence on the sampling rate of the needle trap. Validation results against the standard NIOSH 1501 method using charcoal tubes for indoor air surveys demonstrated good accuracy for the NT approach. The reproducibility of the NT-2 was about 1% for benzene. The detection limits for FID detection and for 25 ml gas sample were 0.23 ng/l, 2.10 ng/l and 1.12 ng/l for benzene, ethylbenzene and o-xylene, respectively.  相似文献   

9.
An on-line solid-phase extraction (SPE) protocol using the cigarette filter as sorbent coupled with high-performance liquid chromatography (HPLC) was developed for simultaneous determination of trace naphthalene (NAPH), phenanthrene (PHEN), anthracene (ANT), fluoranthene (FLU), benzo(b)fluoranthene (BbF), benzo(k)fluoranthene (BkF), benzo(a)pyrene (BaP), and benzo(ghi)perylene (BghiP) in water samples. To on-line interface solid-phase extraction to HPLC, a preconcentration column packed with the cigarette filter was used to replace a conventional sample loop on the injector valve of the HPLC for on-line solid-phase extraction. The sample solution was loaded and the analytes were then preconcentrated onto the preconcentration column. The collected analytes were subsequently eluted with a mobile phase of methanol-water (95:5). HPLC with a photodiode array detector was used for their separation and detection. The detection limits (S/N = 3) for preconcentrating 42 mL of sample solution ranged from 0.9 to 58.6 ng L(-1) at a sample throughput of 2 samples h(-1). The enhancement factors were in the range of 409-1710. The developed method was applied to the determination of trace NAPH, PHEN, ANT, FLU, BbF, BkF, BaP and BghiP in local river water samples. The recoveries of PAHs spiked in real water samples ranged from 87 to 115%. The precisions for nine replicate measurements of a standard mixture (NAPH: 4.0 microg L(-1), PHEN: 0.40 microg L(-1), ANT: 0.40 microg L(-1), FLU: 2.0 microg L(-1), BbF: 1.6 microg L(-1), BkF: 2.0 microg L(-1), BaP: 2.0 microg L(-1), BghiP: 1.7 microg L(-1)) were in the range of 1.2-5.1%.  相似文献   

10.
Summary A new dual injector solvent focussing and elution technique developed for high-performance liquid chromatography (HPLC) greatly improves chromatographic efficiency for the on-line analysis of C18 solid-phase extraction (SPE) cartridges. Solutions containing three benzene homologs were used to characterize the dual injector analysis technique and to compare the chromatographic efficiency of this method with conventional SPE analysis methods. Sampling was performed off-line using a glass precolumn cartridge (3 mm i.d. × 30 mm) packed with 15–35 μm C18 silica. On-line cartridge analysis was achieved with two injection valves in either serial or parallel configuration. The injection loop of the first valve contains the eluting solvent, and the cartridge holder is connected in place of the injection loop of the second valve. When an injection is made, both valves are turned to the inject position, and the solvent plug is forced through the cartridge, focussing the analyte at the solvent front as it elutes the cartridge. Solvent focussing at the head of the column, resulting from preconditioning of the column with a small plug of water during injection, further minimizes the variance of the injection plug and improves the chromatographic efficiency. The technique has potential applications to environmental and biological fluid analysis where analyte preconcentration and resolution from the sample matrix components may be difficult with current SPE methods.  相似文献   

11.
A sampling system for high resolution gas-liquid chromatography, based on the dynamic solvent effect, is described. Volatiles are accumulated off-line in a concentrator/injector and delivered to the column using an on-line inlet. Volatiles may be accumulated from gaseous or liquid matrices; they may be transferred to these by gas sparging or solvent extraction of any type of sample. The sampling technique is quantitatively precise; e.g. coefficients of variation of peak percentage areas better than 5% for a range of solutes at a concentration of 2:107. Examples of the application of the sampling system are presented.  相似文献   

12.
A simple and versatile system is described for the on-line coupling of SFE to capillary GC. The interfacing consists of a programmed temperature vaporizer (PTV) injector. With this injector it is possible to combine solute trapping, elimination of a high flow of extraction fluid, and quantitative transfer of solutes to the seperation column. The problems caused by impurities in the extraction fluid in on-line SFE-GC are discussed. Simple methods are described for the purification of commercially available carbon dioxide. The trapping efficiency of the PTV injector is studied. Applications of the SFE-PTV-GC system are given for the analysis of polymer anti-degradants, polar compounds, and samples with environmental relevance.  相似文献   

13.
A highly selective imprinted amino-functionalized silica gel sorbent was prepared by combining a surface molecular imprinting technique with a sol-gel process for on-line solid-phase extraction-HPLC determination of trace pentachlorophenol (PCP) in water samples. The PCP-imprinted amino-functionalized silica sorbent was characterized by FT-IR, SEM, nitrogen adsorption and the static adsorption experiments. The imprinted functionalized silica gel sorbent exhibited high selectivity and offered a fast kinetics for the adsorption and desorption of PCP. The prepared sorbent was shown to be promising for on-line solid-phase extraction for HPLC determination of trace levels of PCP in environmental samples. With a sample loading flow rate of 5 ml min(-1) for 2 min, an enhancement factor of 670 and a detection limit (S/N = 3) of 6 ng l(-1) were achieved at a sample throughput of five samples h(-1). The precision (RSD) for nine replicate on-line sorbent extractions of 10 microgl(-1) PCP was 3.8%. The sorbent also offered good linearity (r = 0.9997) for on-line solid-phase extraction of trace levels of PCP. The method was applied to the determination of PCP in local lake water, river water and wastewater samples.  相似文献   

14.
The sulfonamides (SAs) have been widely used as effective chemotherapeutics and growth promoters in animals' feeding, but their residues could be a potential danger to human health due to their carcinogenic potency and possible antibiotic resistance. Development of a simple and sensitive method for the determination of SAs residues in food of animal origin, therefore, is of great significance. An on-line solid-phase extraction (SPE) method using multiwalled carbon nanotubes as sorbent coupled with high-performance liquid chromatography (HPLC) for simultaneous determination of 10 sulfonamides (SAs) in eggs and pork was developed. The adsorptive potential of carbon nanotubes for solid-phase extraction of sulfonamides was investigated for the first time in the present paper. To on-line interface solid-phase extraction with HPLC, a conventional sample loop on the six-port injector valve of the HPLC was replaced by a preconcentration column packed with carbon nanotubes. The analytes in water solution were preconcentrated onto the preconcentration column and subsequently eluted with mobile phase of methanol-water (22:78). The developed on-line solid-phase extraction method for HPLC permitted the current HPLC separation and the next preconcentration proceeded in parallel, and thus allows one determination finished within 35 min. The RSD of 10 SAs for nine replicate measurements of a standard mixture of 1 microgl(-1) were in the range of 2.5-7.8%. The method was applied to the determination of trace sulfadiazin (SDZ), sulfamerazine (SMR), sulfadimidine (SDMD), sulfathiazole (STZ), sulfamoxol (SMO), sulfamethizole (SMT), sulfamethoxypyridazine (SMP), sulfachlorpyridazine (SCP), sulfadoxin (SDX) and sulfisoxazole (SIA) in eggs and pork. The results indicated that the proposed method was simple, cost-effective and sensitive.  相似文献   

15.
The use of the extracting syringe (ESy), a fully automated membrane-based extraction technique, for analysis of phthalate esters in complex aqueous samples has been investigated. The ESy, working as an autosampler that combines the extraction process and injection into the gas chromatograph (GC) in one single step, is placed on top of the GC equipped with a flame ionisation detector. The aqueous samples are loaded in a tray and automatically extracted by employing microporous membrane liquid-liquid extraction principle. After the extraction, the extract is directly injected into the GC's programmable temperature vaporisation injector. Six different phthalate esters were used as model compounds. Four extraction solvents were tested and the addition of sample organic modifier was examined.Toluene was the optimal solvent to use for extraction. Due to the large variation in polarity of phthalate esters, 50% methanol as organic modifier had to be added to the samples so as to extract the most nonpolar phthalate esters; di-2-ethylhexylphthalate and di-n-octylphthalate, whereas the other four relatively polar phthalate esters were extracted from unmodified samples. No significant difference between extraction of river water, leachate water from a landfill and reagent water was noted, except for minor deviations. The extraction time was 20 min for extraction of a 1-mL sample, resulting in a good linearity for all aqueous media investigated, good enrichment factors (54-110 folds) and low LOD values (0.2-10 ng mL−1) and relative standard deviation (%R.S.D.; 0.9-3.7%).  相似文献   

16.
Abstract

In the Netherlands for the determination of more than 400 pesticides thirteen multi residue methods and about 170 single residue methods are in use. A literature search learns that about 200 pesticides are gaschromatography (GC) amenable, that quantitative extraction procedures exist and these pesticides also give good recovery when gelpermeation (GPC) is used for cleanup of extracts. A strategy is discussed to develop a universal multi pesticide method, especially paying attention to plant material, using a universal very sensitive detection system, e.g. the ion trap detector.

Experimental data obtained with diverging matrices are presented together with some thoughts on on-line GPC-GC combinations, using a temperature programmable injector in the GC system.  相似文献   

17.
侯英  杨蕾  王保兴  徐济仓  杨勇  杨燕  曹秋娥  谢小光 《色谱》2006,24(6):601-605
应用搅拌棒吸附萃取法(SBSE)提取烟用香料的化学成分,并利用热脱附(TD)和色谱-质谱联用(GC-MS)进行分析。对影响萃取效果的因素(萃取时间和氯化钠的加入量)进行了考察,并采用正交试验法对影响热脱附的3个主要因素(脱附温度、脱附时间和冷阱温度)进行了优化,得到了较优的实验条件。对方法的重现性进行了考察,同一样品6次测定所得30个组分的峰面积的相对标准偏差(RSD)平均值小于10%,说明所建立方法的重现性较好。在样品中鉴别出酯类、酮类和醛类等30种不同化学组分,这些物质反映了该香料的香气特点。实验证明SBSE和TD适用于烟用香料的快速分析测定。  相似文献   

18.
An automated, simple and sensitive method based on selective pressurized liquid extraction (SPLE) was developed for the analysis of polycyclic aromatic hydrocarbons in sewage sludge samples. The new sample preparation procedure consists of on-line clean-up by inclusion of sorbents in the extraction cell, and combines elevated temperatures and pressures with liquid solvents to achieve fast and efficient removal of target analytes from complex sewage sludge matrices. The effects of various operational parameters (e.g. sample pretreatment, extraction solvent, temperature, pressure, static time, etc.) on the performance of SPLE procedure were carefully investigated, obtaining the best results when SPLE conditions were fixed at 140 °C, 1500 psi, static time of 5 min and n-hexane as extraction solvent. A new programmed temperature vaporization–gas chromatography–tandem mass spectrometry method based on large volume injection (PTV–LVI–GC–MS/MS) was also developed and analytical determinations were performed by high performance liquid chromatography coupled with fluorescence detection and GC–MS/MS. The extraction yields for the different compounds obtained by SPLE ranged from 84.8% to 106.6%. Quantification limits obtained for all of these studied compounds (between 0.0001 and 0.005 μg g−1, dry mass) were well below the regulatory limits for all compounds considered. To test the accuracy of the SPLE technique, the optimized methodology was applied to the analysis of a certified reference material (sewage sludge (BCR088)) and a reference material (sewage sludge (RTC-CNS312-04)), with excellent results.  相似文献   

19.
毕月玲  许桐  陈利琴 《色谱》2021,39(12):1306-1313
生物单胺包括儿茶酚胺类以及5-羟色胺等,在中枢神经系统中扮演着非常关键的角色,也是临床上诊断神经内分泌肿瘤疾病的重要生物标志物。由于这类单胺类物质的强化学极性导致传统吸附材料对其吸附效果不佳,从复杂生物样本中同时检测更多的生物单胺存在挑战性。该文建立了一种基于聚冠醚纳米纤维在线固相萃取检测尿液中3种儿茶酚胺(多巴胺、肾上腺素、去甲肾上腺素)和5-羟色胺的方法。采用静电纺丝法制备聚二苯并-18-冠-6醚-聚苯乙烯复合纳米纤维(PCE-PS),制成装填纤维的固相萃取(PFSPE)柱,再将PFSPE柱与HPLC进行在线联用。该在线PFSPE-HPLC方法采用双三元泵进行样品富集净化和分析,左泵连接PFSPE柱,进行样品富集净化;右泵连接分析柱进行样品分离检测。控制切换阀的切换,实现样品富集后洗脱至分析柱中分离检测。结果表明,在线PFSPE-HPLC检测尿液儿茶酚胺(多巴胺、肾上腺素、去甲肾上腺素)和5-羟色胺在1~200 ng/mL范围内有良好的线性关系,线性相关系数达0.996以上。3种儿茶酚胺和5-羟色胺的检出限(S/N=3)分别为1和2.5 ng/mL,定量限(S/N=10)分别为2.5和5 ng/mL。空白尿液和实际尿液加标回收率在83.5%~117.7%之间,日内精密度<10%。PCE-PS复合纳米纤维在多次使用后无明显变化,具有良好的稳定性,可重复使用达95次以上。在线PFSPE-HPLC方法能够集样品在线前处理与分析检测于一体,省时省力,实现分析过程的高度自动化。该方法成功应用于尿液中3种儿茶酚胺和5-羟色胺的检测,可以为临床上相关疾病检测诊断和研究提供有力的技术支持。  相似文献   

20.
Summary The repeatability and discrimination of a home-made splitter injector, operated under various conditions, towards a C-6 to C-24 test sample were investigated. Other different test samples were analysed to prove the integrity of the injector. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号