首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Artificial neural network (ANN) and a hybrid principal component analysis-artificial neural network (PCA-ANN) classifiers have been successfully implemented for classification of static time-of-flight secondary ion mass spectrometry (ToF-SIMS) mass spectra collected from complex Cu–Fe sulphides (chalcopyrite, bornite, chalcocite and pyrite) at different flotation conditions. ANNs are very good pattern classifiers because of: their ability to learn and generalise patterns that are not linearly separable; their fault and noise tolerance capability; and high parallelism. In the first approach, fragments from the whole ToF-SIMS spectrum were used as input to the ANN, the model yielded high overall correct classification rates of 100% for feed samples, 88% for conditioned feed samples and 91% for Eh modified samples. In the second approach, the hybrid pattern classifier PCA-ANN was integrated. PCA is a very effective multivariate data analysis tool applied to enhance species features and reduce data dimensionality. Principal component (PC) scores which accounted for 95% of the raw spectral data variance, were used as input to the ANN, the model yielded high overall correct classification rates of 88% for conditioned feed samples and 95% for Eh modified samples.  相似文献   

2.
《Analytical letters》2012,45(14):2384-2393
Near infrared spectroscopy in combination with appropriate chemometric methods is an effective technique for quantitative analysis of parameters of interest for the pharmaceutical industry. In this study, the artificial neural network (ANN) was applied to monitor critical parameters (compression force, tablet hardness, mean particle size, and active pharmaceutical ingredient concentration of tablets) in the process of naproxen pharmaceutical preparation. The performance of ANN was compared to linear methods (partial least squares regression (PLS) and synergy interval partial squares (siPLS)). The ANN models for compression force, tablet hardness, mean particle size, and active pharmaceutical ingredient concentration of tablets yielded the low root mean square error of prediction (RMSEP) values of 0.936 KN, 0.302 kg, 4.49 mg, and 2.14 µm, respectively. The predictive ability of the PLS model was improved by siPLS with selection of spectral regions and the best performance among all calibration methods was showed by the nonlinear method (ANN). Effective models were built by using these approaches using near infrared spectroscopy.  相似文献   

3.
建立了中药口服固体制剂原辅料近红外(NIR)光谱数据库,采用模式识别方法研究了NIR光谱数据在物料分类和物性预测中的应用。使用便携式近红外光谱仪快速测量149批原辅料粉末的NIR漫反射光谱数据,并录入iTCM数据库。利用主成分分析(PCA)法探究NIR光谱数据对已知结构物料的分类能力,采用偏最小二乘(PLS)法研究了NIR光谱对原辅料物性参数和直接压片片剂性能的预测能力。经标准正态变量变换(SNV)+Savitzky-Golay(SG)平滑+一阶导数处理后的NIR光谱数据对微晶纤维素、乳糖、乙基纤维素、交联聚维酮和羟丙基甲基纤维素这5类辅料的区分能力较好。NIR光谱数据与原辅料粉末粒径、密度和吸湿性的相关性较强。NIR光谱信息作为物料物理性质的补充,可提高粉末直接压片片剂性能预测模型的性能。NIR光谱数据是iTCM数据库物性参数数据的补充,物性参数与NIR光谱数据的结合能更全面地表征原辅料的性质。  相似文献   

4.
In multivariate spectral calibration by principal component regression (PCR), the principal components (PCs) are calculated from the response data measured at all employed instrument channels; however some channels are redundant and their responses do not possess useful information. Thus, the extracted PCs possess mixed information from both useful and redundant channels. In this work, we propose a segmentation approach based on unsupervised pattern recognition to identify the most informative spectral region and then to construct a stable multivariate calibration model by PCR. In this method, the instrument channels are clustered into different segments via Kohonen self‐organization map. The spectral data of each segment are then subjected to PCA and the derived PCs are used as input variables for an inverse least square (ILS) regression model employing stepwise selection of the informative PCs. The proposed method was evaluated by the analysis of four simulated and six experimental data sets. It was found that our proposed method can model the above data sets with prediction errors lower than conventional partial least squares (PLS) and PCR methods. In addition, the prediction ability of our method was better than the previously reported models for these data sets. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
Differential Pulse Voltammetry has been used for the simultaneous determination of cysteine, tyrosine and trptophan on the unmodified glassy carbon electrode. In the analysis of these analytes in the same samples, the main difficulty is the high degree of overlapping of voltammograms. The relationships between the currents and the concentrations are complex and highly nonlinear. The predictive ability of principal component regression (PCR), partial least squares regression (PLS), genetic algorithm‐partial least squares regression (GA‐PLS) and principal component‐artificial neural networks (PC‐ANNs) were examined for simultaneous determination of three amino acids. For a regression model, everything that could not help in constructing the model may be considered as noise without further specification. PC‐ANN and GA‐PLS use significant data and show superiority over other applied multivariate methods. The proposed method was also applied satisfactorily to determination of analytes in some synthetic samples.  相似文献   

6.
This study compares the performance of partial least squares (PLS) regression analysis and artificial neural networks (ANN) for the prediction of total anthocyanin concentration in red-grape homogenates from their visible-near-infrared (Vis-NIR) spectra. The PLS prediction of anthocyanin concentrations for new-season samples from Vis-NIR spectra was characterised by regression non-linearity and prediction bias. In practice, this usually requires the inclusion of some samples from the new vintage to improve the prediction. The use of WinISI LOCAL partly alleviated these problems but still resulted in increased error at high and low extremes of the anthocyanin concentration range. Artificial neural networks regression was investigated as an alternative method to PLS, due to the inherent advantages of ANN for modelling non-linear systems. The method proposed here combines the advantages of the data reduction capabilities of PLS regression with the non-linear modelling capabilities of ANN. With the use of PLS scores as inputs for ANN regression, the model was shown to be quicker and easier to train than using raw full-spectrum data. The ANN calibration for prediction of new vintage grape data, using PLS scores as inputs, was more linear and accurate than global and LOCAL PLS models and appears to reduce the need for refreshing the calibration with new-season samples. ANN with PLS scores required fewer inputs and was less prone to overfitting than using PCA scores. A variation of the ANN method, using carefully selected spectral frequencies as inputs, resulted in prediction accuracy comparable to those using PLS scores but, as for PCA inputs, was also prone to overfitting with redundant wavelengths.  相似文献   

7.
基于小波系数的近红外光谱局部建模方法与应用研究   总被引:2,自引:0,他引:2  
局部建模方法使用与预测样本相似的样本建立模型,可解决光谱响应与浓度之间的非线性问题,扩大模型的适用范围,提高预测准确度。采用小波变换进行数据压缩并利用小波系数之间的欧氏距离作为光谱相似性的判据,实现了近红外光谱定量分析的局部建模方法,避免了样本之间的依赖性。将所建立的方法用于烟草样品中氯含量的测定,100次重复计算得到的预测集均方根误差(RMSEP)平均值为0.0665,标准偏差(σ)为0.0045,优于全局建模和基于主成分的局部建模方法。  相似文献   

8.
The near-infrared(NIR) diffuse reflectance spectroscopy was used to study the content of Berberine in the processed Coptis. The allocated proportions of Coptis to ginger, yellow liquor or Evodia rutaecarpa changed according to the results of orthogonal design as well as the temperature. For as withdrawing the full and effective information from the spectral data as possible, the spectral data was preprocessed through first derivative and multiplicative scatter correetion(MSC) according to the optimization results of different preprocessing methods. Firstly, the model was established by partial least squares(PLS); the coefficient of determination(R2) of the prediction was 0.839, the root mean squared error of prediction(RMSEP) was 0.1422, and the mean relative error(RME) was 0.0276. Secondly, for reducing the dimension and removing noise, the spectral variables were highly effectively compressed via the wavelet transformation(WT) technology and the Haar wavelet was selected to decompose the spectral signals. After the wavelet coefficients from WT were input into the artificial neural network(ANN) instead of the spectra signal, the quantitative analysis model of Berberine in processed Coptis was established. The R^2 of the model was 0.9153, the RMSEP was 0.0444, and the RME was 0.0091. The values of appraisal index, namely R^2, RMSECV, and RME, indicate that the generalization ability and prediction precision of ANN are superior to those of PLS. The overall results show that NIR spectroscopy combined with ANN can be efficiently utilized for the rapid and accurate analysis of routine chemical compositions in Coptis. Accordingly, the result can provide technical support for the further analysis of Berberine and other components in processed Coptis. Simultaneously, the research can also offer the foundation of quantitative analysis of other NIR application.  相似文献   

9.
Simultaneous determination of several elements (U, Ta, Mn, Zr and W) with inductively coupled plasma atomic emission spectrometry (ICP-AES) in the presence of spectral interference was performed using chemometrics methods. True comparison between artificial neural network (ANN) and partial least squares regression (PLS) for simultaneous determination in different degrees of overlap was investigated. The emission spectra were recorded at uranium analytical line (263.553 nm) with a 0.06 nm spectral window by ICP-AES. Principal component analysis was applied to data and scores on 5 dominant principal components were subjected to ANN. A 5-5-5 (input, hidden and output neurons) network was used with linear transfer function after both hidden and output layers. The PI,S model was trained with five latent variables and 20 samples in calibration set. The relative errors of predictions (REP) in test set were 3.75% and 3.56% for ANN and PLS respectively.  相似文献   

10.
In this study, the simultaneous determination of paracetamol, ibuprofen and caffeine in pharmaceuticals by chemometric approaches using UV spectrophotometry has been reported as a simple alternative to using separate models for each component. Spectra of paracetamol, ibuprofen and caffeine were recorded at several concentrations within their linear ranges and were used to compute the calibration mixture between wavelengths 200 and 400 nm at an interval of 1 nm in methanol:0.1 HCl (3:1). Partial least squares regression (PLS), genetic algorithm coupled with PLS (GA-PLS), and principal component-artificial neural network (PC-ANN) were used for chemometric analysis of data and the parameters of the chemometric procedures were optimized. The analytical performances of these chemometric methods were characterized by relative prediction errors and recoveries (%) and were compared with each other. The GA-PLS shows superiority over other applied multivariate methods due to the wavelength selection in PLS calibration using a genetic algorithm without loss of prediction capacity. Although the components show an important degree of spectral overlap, they have been determined simultaneously and rapidly requiring no separation step. These three methods were successfully applied to pharmaceutical formulation, capsule, with no interference from excipients as indicated by the recovery study results. The proposed methods are simple and rapid and can be easily used in the quality control of drugs as alternative analysis tools.  相似文献   

11.
This work describes a novel experimental design aimed at building a calibration set constituted by samples containing a different number of components. The algorithm performs a reiteration process to maintain the number of samples at the lower value as possible and to ensure an homogeneous presence of all the concentration levels. The mixture design was applied to a drug system composed by one-to-four components in different combination. The resolution of the system was performed by three multivariate UV spectrophotometric methods utilizing principal component regression (PCR) and partial last squares (PLS1 and PLS2) algorithms. The calibration set was composed by 61 references on four concentration levels, including 15 samples for each quaternary, ternary and binary composition and 16 one-component samples. The calibration models were optimized through a careful selection of number of factors and wavelength zones, in such a way as to remove interferences from instrumental noise and excipients present in the pharmaceutical formulations. The prediction power of the regression models were verified and compared by analysis of an external prediction set. The models were finally used to assay pharmaceutical specialities containing the studied drugs in one-to-four formulations.  相似文献   

12.
We developed a method for determination of ascorbic acid in pharmaceutical preparations containing various excipients by using near infrared diffuse reflectance spectroscopy and two different calibration methods, viz. stepwise multiple linear regression (SMLR) and partial least-squares (PLS) regression, which provided comparable results and resulted in prediction errors of 1-2%. However, the PLS method provided somewhat better results with the more complex samples.  相似文献   

13.
In this work, a strategy was proposed to discriminate Polygoni Multiflori Radix (PMR) and its adulterant (Cynanchi Auriculati Radix, CAR). Ultra‐high performance liquid chromatography (UHPLC) fingerprints were established to analyze samples containing PMR, CAR and mixtures simultaneously. Multivariate classification methods were applied to analyze the obtained UHPLC fingerprints, including principal component analysis (PCA), partial least square discriminant analysis (PLS‐DA), soft independent modeling of class analogy (SIMCA), support vector machine discriminant analysis (SVMDA) and counter‐propagation artificial neural network (CP‐ANN). A plot of PCA score showed that PMR and CAR samples belonged to separate clusters (PMR class and CAR class), and samples of mixtures were located near PMR or CAR classes. Analysis by PLS‐DA, SVMDA and CP‐ANN performed well for recognition and prediction in terms of PMR and CAR samples. Moreover, the PLS‐DA method performed best in the detection of adulterated samples, even if the adulterant was about 25%.  相似文献   

14.
In the present study, chemometric analysis of visible spectral data of phospho-and silico-molybdenum blue complexes was used to develop artificial neural networks (ANNs) for the simultaneous determination of the phosphate and silicate. Combinations of principal component analysis (PCA) with feed-forward neural networks (FFNNs) and radial basis function networks (RBFNs) were built and investigated. The structures of the models were simplified by using the corresponding important principal components as input instead of the original spectra. Number of inputs and hidden nodes, learning rate, transfer functions and number of epochs and SPREAD values were optimized. Performances of methods were tested with root mean square errors prediction (RMSEP, %), using synthetic solutions. The obtained satisfactory results indicate the applicability of this ANN approach based on PCA input selection for determination in highly spectral overlapping. The results obtained by FFNNs and by RBF networks were compared. The applicability of methods was investigated for synthetic samples, for detergent formulations, and for a river water sample.  相似文献   

15.
偏最小二乘与人工神经网络联用对70个饲料样品建立起天门冬氨酸(Asp)、谷氨酸(Glu)、丝氨酸(Ser)和组氨酸(His)4种氨基酸含量的预测校正模型,以样品平行扫描光谱验证校正模型预测的准确性和重现性。用偏最小二乘法将原始数据压缩为主成分,采用单隐层的反向传播网络建模。取前3个主成分的12个数据输入网络,以Kolmogorov定理为依据,经过实验确定中间层的神经元个数为25,初始训练迭代次数为1000。偏最小二乘-反向传播网络模型对样品4个组分含量的预测决定系数(R2)分别为:0.981、0.997、0.979、0.946;样品平行扫描光谱预测值的标准偏差分别为:0.020、0.029、0.017、0.023。本研究为近红外快速检测在组分含量较低的样品实现多组分同时测定提供了思路。  相似文献   

16.
Near-infrared reflection spectroscopy (NIRS) was used in combination with principal component analysis (PCA) and partial least squares (PLS) regression to determine the silica packing properties, whether endcapped (EC) or non-endcapped, and the amount of surface total carbon coverage (%). A preparation technique for the reproducible analysis of bulk materials is covered as well as spectral data pretreatments to enhance prediction accuracy of the PLS models. Especially derivatives and scatter correction methods turned out to be well suited. A standard error of prediction (SEP) of 0.57% C for the determination of the total carbon load of octadecylated (C18) silica was found. In case of the C18-EC silica a SEP of 0.51% carbon gives rise to a robust and accurate model. The presented method allows the simultaneous determination of several parameters, e.g. particle and pore size or surface modifications, from a single spectrum and is amenable to implementation for in-line or on-line analysis in the silica producing industry.  相似文献   

17.
The UV spectrophotometric analysis of a multicomponent mixture containing paracetamol, caffeine, tripelenamine and salicylamide by using multivariate calibration methods, such as principal component regression (PCR) and partial least-squares regression (PLS), was described. The calibration set was based on 47 reference samples, consisting of quaternary, ternary, binary and single-component mixtures, with the aim to develop models able to predict the concentrations of unknown samples containing as many as one-to-four components. The calibration models were optimized by an appropriate selection of the number of factors as well as wavelength ranges to be used for building up the data matrix and excluding any information about the interfering excipients included in pharmaceutics. The PCR and PLS models were compared and their predictive performance was inferred by a successful application to the assays of synthetic mixtures and pharmaceutical formulations.  相似文献   

18.
The complementary use of partial least-squares (PLS) multivariate calibration and artificial neural networks (ANNs) for the simultaneous spectrophotometric determination of three active components in a pharmaceutical formulation has been explored. The presence of non-linearities caused by chemical interactions was confirmed by a recently discussed methodology based on Mallows augmented partial residual plots. Ternary mixtures of chlorpheniramine, naphazoline and dexamethasone in a matrix of excipients have been resolved by using PLS for the two major analytes (chlorpheniramine and naphazoline) and ANNs for the minor one (dexamethasone). Notwithstanding the large number of constituents, their high degree of spectral overlap and the occurrence of non-linearities, rapid and simultaneous analysis has been achieved, with reasonably good accuracy and precision. No extraction procedures using non-aqueous solvents are required.  相似文献   

19.
A simple and reliable method for simultaneous spectrophotometric determination of iron(II) and cobalt(II) has been established. The method is based on complex formation with 1‐(2‐pyridylazo)‐2‐naphtol (PAN) in a micellar medium. Despite a spectral overlap, Fe2+ and Co2+ have been simultaneously determined with chemometric approaches involving principal component artificial neural network (PC‐ANN), principal component regression (PCR) and partial least squares (PLS). Various synthetic mixtures of iron and cobalt were assessed and the results obtained by the applications of these chemometric approaches were evaluated and compared. It was found that the PC‐ANN method afforded relatively better precision than that of PCR or PLS. The proposed method permits detection limits of 0.05 and 0.07 ng mL?1 for Co and Fe, respectively. The influences of pH, ligand amount, solvent percentage and time on the absorbance were also investigated. The proposed method was also applied satisfactorily for the determination of Fe(II) and Co(II) in real and synthetic samples.  相似文献   

20.
The performances of three multivariate analysis methods—partial least squares (PLS) regression, secured principal component regression (sPCR) and modified secured principal component regression (msPCR)—are compared and tested for the determination of human serum albumin (HSA), γ-globulin, and glucose in phosphate buffer solutions and blood glucose quantification by near-infrared (NIR) spectroscopy. Results from the application of PLS, sPCR and msPCR are presented, showing that the three methods can determine the concentrations of HSA, γ-globulin and glucose in phosphate buffer solutions almost equally well provided that the prediction samples contain the same spectral information as the calibration samples. On the other hand, when some potential spectral features appear in new measurements, sPCR and msPCR outperform PLS significantly. The reason for this is that such spectral features are not included during calibration, which leads to a degradation in PLS prediction performance, while sPCR and msPCR can improve their predictions for the concentrations of the analytes by removing the uncalibrated features from the original spectra. This point is demonstrated by successfully applying sPCR and msPCR to in vivo blood glucose measurements. This work therefore shows that sPCR and msPCR may provide possible alternatives to PLS in cases where some uncalibrated spectral features are present in measurements used for concentration prediction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号