首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 473 毫秒
1.
The composition of the ship's ballast water is complex and contains a large number of microalgae cells, bacteria, microplastics, and other microparticles. To increase the accuracy and efficiency of detection of the microalgae cells in ballast water, a new microfluidic chip for continuous separation of microalgae cells based on alternating current dielectrophoresis was proposed. In this microfluidic chip, one piece of 3‐dimensional electrode is embedded on one side and eight discrete electrodes are arranged on the other side of the microchannel. An insulated triangular structure between electrodes is designed for increasing the inhomogeneity of the electric field distribution and enhancing the dielectrophoresis (DEP) force. A sheath flow is designed to focus the microparticles near the electrode, so as to increase the suffered DEP force and improve separation efficiency. To demonstrate the performance of the microfluidic separation chip, we developed two species of microalgae cells (Platymonas and Closterium) and a kind of microplastics to be used as test samples. Analyses of the related parameters and separation experiments by our designed microfluidic chip were then conducted. The results show that the presented method can separate the microalgae cells from the mixture efficiently, and this is the first time to separate two or more species of microalgae cells in a microfluidic chip by using negative and positive DEP force simultaneously, and moreover it has some advantages including simple operation, high efficiency, low cost, and small size and has great potential in on‐site pretreatment of ballast water.  相似文献   

2.
微流控芯片液滴生成与检测技术研究进展   总被引:1,自引:0,他引:1  
微流控芯片液滴技术是一种操控微小体积液体的新技术,既可实现高通量微观样本的生成及控制,也可进行独立液滴的操作。分散的微液滴单元可作为理想的微反应器,在生物医药中的药物筛选、材料筛选和高附加值微颗粒材料合成领域展现出巨大的应用潜力。液滴微流控芯片是利用流体剪切力的改变,使互不相溶的两相流体在其界面处生成稳定、有序的液滴,目前微液滴的生成方法主要有水动力法、气动法、光控法和电动法等。基于液滴的微流控系统越来越多地被应用于执行复杂的多重反应、测量和分析,可以进行超小体积和超高吞吐量的化学和生物实验。对液滴微流控系统而言,液滴的速度、大小和内容物含量会影响最终的检验结果,因此对液滴形成速率和液滴的内容物含量的实时检测至关重要,目前最常用的液滴检测方法有光学检测技术与电学传感检测技术。对两相流液滴生成机理以及现有液滴生成技术开展了讨论分析,同时对液滴检测技术进行了评述。  相似文献   

3.
Packaging of microfluidic chips via interstitial bonding technique.   总被引:2,自引:0,他引:2  
In this paper, we describe an interstitial bonding technique for packaging of microfluidic chips. The cover plate is first placed on top of the microfluidic chip, followed by dispensing the UV-curable resin into the resin-loading reservoirs. With the interstitial space between the cover plate and the microfluidic chip connecting to the loading reservoirs, the UV-curable resin wicks through capillary force action and hydrostatic pressure generated by the liquid level in the resin-loading reservoirs. When reaching the microchannels, the UV-curable resin stops flowing into the microchannels due to the force balance between the surface tension and hydrostatic pressure. The assembly is then placed under the UV light, followed by further curing in the thermal oven. It is found that there is no leakage from the bonded microfluidic chips and a good DNA separation result was obtained by using the microfluidic chips as fabricated. This bonding technique is relatively simple and fast, which can be applied to the packaging of microfluidic chips made from hybrid materials with complicated designs as long as the interstitial space connects to the loading reservoirs.  相似文献   

4.
Lin YH  Yang YW  Chen YD  Wang SS  Chang YH  Wu MH 《Lab on a chip》2012,12(6):1164-1173
This study reports the utilisation of an optically switched dielectrophoretic (ODEP) force for the manipulation and assembly of cell-encapsulating alginate microbeads in a microfluidic perfusion cell culture system for bottom-up tissue engineering. One of the key features of this system is the ODEP force-based mechanism, which allows a commercial projector to be coupled with a computer to manipulate and assemble cell-encapsulating microbeads in an efficient, manageable, and user-friendly manner. Another distinctive feature is the design of the microfluidic cell culture chip, which allows the patterned cell-encapsulating microbeads to be cultivated on site under culture medium perfusion conditions. For demonstrating its application in bottom-up cartilage tissue engineering, chondrocyte-encapsulating alginate microbeads varying in encapsulated cell densities were generated. The manipulation forces associated with operating the alginate microbeads were experimentally evaluated. The results revealed that the measured manipulation forces increased with increases in both the applied electric voltage and the number of cells in the alginate microbeads. Nevertheless, the observed manipulation force was found to be independent of the size of the cell-free alginate microbeads. It can be speculated that the friction force may influence the estimation of the ODEP force within the experimental conditions investigated. In this study, chondrocyte-encapsulating alginate microbeads with three different cell densities were manipulated and assembled in the proposed microfluidic system to form a compact sheet-like cell culture construct that imitates the cell distribution in the cross-section of native articular cartilage. Moreover, the demonstration case also showed that the cell viability of the cultured cells in the microfluidic system remained as high as 96 ± 2%. In this study, four sheet-like cell culture constructs were stacked to create a larger assembled cell culture construct. The cell distribution inside the cell culture construct was further confirmed by a confocal microscopy observation, which showed that the distribution was similar to that in native articular cartilage. As a whole, the proposed system holds great promise as a platform for engineering tissue constructs with easily tunable inner cell distributions.  相似文献   

5.
生化芯片上探测器的总体性能将影响整个芯片分析系统的检出限、检测速度和适用范围等指标,是芯片分析系统的一个关键部分.针对生化芯片检测区的检测体积小、样品剂量少以及与生化芯片集成等特殊要求,设计了易于集成在芯片内的,用分光光度法对混合后液体的消逝波吸收光谱探测的方法.  相似文献   

6.
设计了一种单螺旋通道的聚二甲基硅氧烷(Poly(dimethylsiloxane),PDMS)微流控芯片,用于副溶血性弧菌气溶胶的快速有效富集。该芯片的特征在于其通道呈螺旋分布,且通道内部含有均匀分布的鱼骨形结构。结果表明,在不同富集时间段内,采用该芯片方法捕获的细菌总数均远高于传统落板法。对于传统落板法无法有效捕获的低浓度样本(10~4CFU/mL)的缺陷,该方法的优势在于:芯片内部的螺旋通道可增大对气溶胶中微生物的离心力;鱼骨形结构的设计增加了待测样品与芯片内壁间的接触几率。此外,以无鱼骨形的螺旋芯片作为对照,验证了鱼骨形结构对于高效富集的意义。此芯片设计巧妙、易于制备、高效便携、富集效果较好,在气溶胶污染严重的水产加工等场所具有较大的应用前景。  相似文献   

7.
任苹  刘京  蔺日胜  刘杨  黄美莎  胡胜  徐友春  李彩霞 《色谱》2018,36(7):599-607
建立了常染色体单核苷酸多态性(SNPs)复合检测芯片体系,用于未知个体的族群来源推断。基于前期筛选的74-SNPs组合,采用竞争性等位基因特异性聚合酶链式反应(PCR)的原理构建SNPs的扩增体系,在微流控芯片的每个反应孔内完成一个SNP的检测,通过高通量PCR微流控芯片实现了其中72个SNPs的同步检测。芯片的扩增由平板PCR仪完成,反应孔的荧光信号通过激光共聚焦扫描仪检测,最终通过提取的荧光值进行结果分析。使用该芯片检测获得52份样本的SNPs分型,分型结果的准确率为100%。以57个人群的3628个样本为参考人群数据库,进行20份样本的族群来源推断,推断结果与样本的实际来源一致。本研究建立的常染色体72个SNPs微流控芯片体系可以有效地进行SNP多态性分析检测,基于参考数据库,20份检测样本族群推断的准确性为100%。  相似文献   

8.
微流控芯片系统在单细胞研究中的应用   总被引:2,自引:0,他引:2  
高健  殷学锋  方肇伦 《化学进展》2004,16(6):975-983
微流控芯片具有网络式通道结构,扩展了在细胞和亚细胞水平进行生命科学研究的能力,为单细胞研究提供了一个新的平台.在微流控芯片通道中,人们利用气压、液压和电压,或利用介电电泳、光学陷阱、行波介电电泳以及磁场等技术,可以操纵细胞通过或驻留在通道内的任意位置,从而使单细胞计数、筛选以及胞内组分分析等操作大大简化.本文对微流控芯片系统在血液流变学、单细胞操纵与计数以及单细胞胞内组分分析中的应用进行了综述,介绍了用于单细胞研究的多种微芯片系统,讨论了芯片上进行单细胞操纵的各种方法  相似文献   

9.
《先进技术聚合物》2018,29(5):1487-1496
High‐performance polymer‐based frictional materials have become increasingly important to improve the mechanical output properties of ultrasonic motors. This study discussed the friction and wear behavior of 2 dominating frictional materials of polymer composites for ultrasonic motors, polyimide (PI), and polytetrafluoroethylene (PTFE) filled by aramid fibers (AF) and molybdenum disulfide (MoS2). To explore the wear mechanisms, the tribo‐pair contact stress was theoretically characterized, and the interface temperature rise was numerically predicted. The predictions showed that the flash temperature on asperity tips could reach the glass transition temperature of the polymer materials. The experimental results indicated that the contact stress and sliding speed have a small effect on the friction of the PI composite but influence considerably the friction of the PTFE composite. A higher contact stress brings about a higher specific wear rate, but a higher sliding speed reduces the wear rate. Compared with AF/MoS2/PTFE, the AF/MoS2/PI has much better tribological performance under high loads and speeds.  相似文献   

10.
Song W  Psaltis D 《Lab on a chip》2011,11(14):2397-2402
We presented a pneumatically tunable 2 × 2 optofluidic switch for on-chip light routing that was controlled by compressed air. The device was fabricated with an optically clear elastomer-polydimethylsiloxane (PDMS)-by soft-lithography. The optical switching is realized with a tunable air-gap mirror by which the light is deflected due to total internal reflection in the bypass state. When the device is subjected to high pressure, the air gap collapses and hence the light will be switched to the crossover state. The device had a switching speed of more than 5 Hz and an extinction ratio of 8 dB. This switch can be readily integrated with other microfluidic circuits. We demonstrated a simple reconfigurable optical waveguide circuit for dual-channel microfluidic spectroscopy measurement on a chip.  相似文献   

11.
Hong JW  Chung KH  Yoon HC 《The Analyst》2008,133(4):499-504
An application of a novel polymer microfluidic chip for sample exchange via natural capillary forces for immuno-analysis is described. The microfluidic device was designed to achieve sample replacement by capillary force only, which would therefore be suitable for point-of-care-testing. Complete and automatic replacement of the sample in the reaction chamber with another one makes the chip able to mimic affinity chromatography and immunoassay processes. The microfluidic chip was made using polymer replication techniques, which were suitable for fast and cheap fabrication. Micrometre-sized polystyrene beads were used for the functionalization of biomolecules. Dinitrophenyl (DNP) and anti-DNP antibody coordination was employed on the chip for fluorescence analysis. DNP was immobilized on the polymer beads via a pre-adsorbed dendrimer layer and the beads were placed in the reaction chamber. Fluorescein tagged anti-DNP was successfully observed by a fluorescence microscope after the completion of the entire flow sequence. A calibration curve was registered based on the anti-DNP concentration. A multiplex sensing was accomplished by adding biotin/streptavidin coordination to the system. DNP and biotin conjugated beads were placed in the reaction chamber in an ordered fashion and biospecific bindings of anti-DNP antibody and streptavidin were observed at their expected sites. A ratiometric analysis was carried out with different concentration ratios of anti-DNP/streptavidin. The microfluidic chip described in this work could be applied to various biological and chemical analyses using integrated washing steps or fluid replacement steps with minimum sample handling.  相似文献   

12.
Mixing a small amount of magnetic beads and regents with large volume samples evenly in microcavities of a microfluidic chip is always the key step for the application of microfluidic technology in the field of magnetophoresis analysis. This article proposes a microfluidic chip for DNA extraction by magnetophoresis, which relies on bubble rising to generate turbulence and microvortices of various sizes to mix magnetic beads with samples uniformly. The construction and working principle of the microfluidic chip are introduced. CFD simulations are conducted when magnetic beads and samples are irritated by the generation of gas bubbles with the variation of supply pressures. The whole mixing process in the microfluidic chip is observed through a high-speed camera and a microfluidic system when the gas bubbles are generated continuously. The influence of supply pressure on the mixing characteristics of the microfluidic chip is investigated and discussed with both simulation and experiments. Compared with magnetic mixing, bubble mixing can avoid the magnetic beads gather phenomenon caused by magnetic forces and provide a rapid and high efficient solution to realize mixing small amount of regents in large volume samples in a certain order without complex moving structures and operations in a chip. Two applications of mixing with the proposed microfluidic chip are also carried out and discussed.  相似文献   

13.
This study develops an improved method for generating aluminum mold inserts used in the replication of polymer‐based microfluidic chip. Since molding masters that are suitable for microfluidic chip replication must have features whose dimensions are of the order of tens to hundreds of microns, micro electrical discharge machining is employed herein to fabricate an aluminum mold insert of a microfluidic chip. The width and depth of the aluminum mold insert for the microfluidic chip are 61.50 and 49.61 µm, respectively. The surface roughness values of the microchannel and the sample reservoir in aluminum mold insert for the microfluidic chip are 53.9 and 34.3 nm, respectively. PMMA material is adopted as the molded microfluidic chip that is produced by micro‐hot embossing molding. The PMMA material can replicate the microchannel and sample reservoir very well when the aluminum mold insert is used in micro‐hot embossing molding. The results indicate that the most important parameter in the replication of molded microfluidic chip is the embossing pressure, which is also the most important parameter in determining the surface roughness of the molded microfluidic chip. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Huang CJ  Lin JL  Chen PH  Syu MJ  Lee GB 《Electrophoresis》2011,32(8):931-938
This study presents a new microfluidic system capable of precise measurements of two important biomarkers, urea and creatinine, automatically. In clinical applications, high levels of these two biomarkers are early indicators of nephropathy or renal failure and should be monitored on a regular basis. The microfluidic system is composed of a microfluidic chip, a control circuit system, a compressed air source and several electromagnetic valves to form a handheld system. The microfluidic chip is fabricated by using micro-electromechanical systems and microfluidic techniques comprising electrochemical sensor arrays and polydimethylsiloxane-based microfluidic structures such as micropumps/micromixers, normally closed valves and microchannels. The microfluidic system performs a variety of critical processes including sample pretreatment, mixing, transportation and detection on a single chip. The experimental results show that the entire procedure takes approximately 40 min, which is much faster than the traditional method (more than 6 h). Furthermore, the total sample volume consumed in each operation is only 0.1 mL, which is significantly less than that required in a large system (5 mL). The developed automatic microfluidic system may provide a powerful platform for further clinical applications.  相似文献   

15.
微流控芯片由于具有试剂和样品用量少、分析速度快、分离效率高、体积小等优点,近几年发展迅速,已应用于医药、化学和生物等领域.本文就微流控芯片的最新研究进展以及它在药物分析中的应用作简要的综述.引用参考文献58篇.  相似文献   

16.
We present a microfluidic cell-culture chip that enables trapping, cultivation and release of selected individual cells. The chip is fabricated by a simple hybrid glass-SU-8-PDMS approach, which produces a completely transparent microfluidic system amenable to optical inspection. Single cells are trapped in a microfluidic channel using mild suction at defined cell immobilization orifices, where they are cultivated under controlled environmental conditions. Cells of interest can be individually and independently released for further downstream analysis by applying a negative dielectrophoretic force via the respective electrodes located at each immobilization site. The combination of hydrodynamic cell-trapping and dielectrophoretic methods for cell releasing enables highly versatile single-cell manipulation in an array-based format. Computational fluid dynamics simulations were performed to estimate the properties of the system during cell trapping and releasing. Polystyrene beads and yeast cells have been used to investigate and characterize the different functions and to demonstrate biological compatibility and viability of the platform for single-cell applications in research areas such as systems biology.  相似文献   

17.
集成核酸提取的实时荧光PCR微全分析系统将核酸提取、PCR扩增与实时荧光检测进行整合,在同一块微流控芯片上实现了核酸分析过程的全自动和全封闭,具有试剂用量少、分析速度快、操作简便等优点。本研究采用微机械加工技术制作集成核酸提取微流控芯片的阳极模,使用组合模具法和注塑法制作具有3D通道的PDMS基片,与玻璃基底通过等离子体键合封装成集成核酸提取芯片。构建了由微流体速度可调节(0~10 mL/min)的驱动控制装置、温控精度可达0.1℃的TEC温控平台、CCD检测功能模块等组成的微全分析系统。以人类血液裂解液为样品,采用硅胶膜进行芯片上核酸提取。系统根据设置好的时序自动执行,以2 mL/min的流体驱动速度完成20μL裂解液上样、清洗;以1 mL/min的流体驱动速度完成DNA洗脱,抽取PCR试剂与之混合注入到反应腔。提取的基因组DNA以链上内参基因GAPDH为检测对象,并以传统手工提取为对照,在该系统平台上进行PCR扩增和熔解曲线分析实验。片上PCR扩增结果显示,扩增曲线明显,Ct值分别为25.3和26.9。扩增产物进行熔解曲线分析得到的熔解温度一致,均为89.9℃。结果表明,此系统能够自动化、全封闭的在微流控芯片上完成核酸提取、PCR扩增与实时定量分析。  相似文献   

18.
This article reports the integration of the fiber optic-particle plasmon resonance (FO-PPR) biosensor with a microfluidic chip to reduce response time and improve detection limit. The microfluidic chip made of poly(methyl methacrylate) had a flow-channel of dimensions 4.0 cm × 900 μm × 900 μm. A partially unclad optical fiber with gold or silver nanoparticles on the core surface was placed within the flow-channel, where the volume of the flow space was about 14 μL. Results using sucrose solutions of various refractive indexes show that the refractive index resolution improves by 2.4-fold in the microfluidic system. The microfluidic chip is capable of delivering a precise amount of biological samples to the detection area without sample dilution. Several receptor/analyte pairs were chosen to examine the biosensing capability of the integrated platform: biotin/streptavidin, biotin/anti-biotin, DNP/anti-DNP, OVA/anti-OVA, and anti-MMP-3/MMP-3. Results show that the response time to achieve equilibrium can be shortened from several thousand seconds in a conventional liquid cell to several hundred seconds in a microfluidic flow-cell. In addition, the detection limit also improves by about one order of magnitude. Furthermore, the normalization by using the relative change of transmission response as the sensor output alleviate the demand on precise optical alignment, resulting in reasonably good chip-to-chip measurement reproducibility.  相似文献   

19.
Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.  相似文献   

20.
Parallel analysis of biomolecules on a microfabricated capillary array chip   总被引:2,自引:0,他引:2  
Shen Z  Liu X  Long Z  Liu D  Ye N  Qin J  Dai Z  Lin B 《Electrophoresis》2006,27(5-6):1084-1092
This paper focused on a self-developed microfluidic array system with microfabricated capillary array electrophoresis (mu-CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda-lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high-voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号