首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Traditional chromatographic methods for the analysis of lignin‐derived phenolic compounds in environmental samples are generally time consuming. In this work, an ultra‐high performance supercritical fluid chromatography method with a diode array detector for the analysis of major lignin‐derived phenolic compounds produced by alkaline cupric oxide oxidation was developed. In an analysis of a collection of 11 representative monomeric lignin phenolic compounds, all compounds were clearly separated within 6 min with excellent peak shapes, with a limit of detection of 0.5–2.5 μM, a limit of quantification of 2.5–5.0 μM, and a dynamic range of 5.0–2.0 mM (R2 > 0.997). The new ultra‐high performance supercritical fluid chromatography method was also applied for the qualitative and quantitative analysis of lignin‐derived phenolic compounds obtained upon alkaline cupric oxide oxidation of a commercial humic acid. Ten out of the previous eleven model compounds could be quantified in the oxidized humic acid sample. The high separation power and short analysis time obtained demonstrate for the first time that supercritical fluid chromatography is a fast and reliable technique for the analysis of lignin‐derived phenols in complex environmental samples.  相似文献   

2.
Hydrosoluble trehalose lipid (a biosurfactant) was employed for the first time as a green extraction solution to extract the main antioxidant compounds (geniposidic acid, chlorogenic acid, caffeic acid, and rutin) from functional plant tea (Eucommia ulmoides leaves). Single‐factor tests and response surface methodology were employed to optimize the extraction conditions for ultrasound‐assisted micellar extraction combined with ultra‐high‐performance liquid chromatography in succession. A Box‐Behnken design (three‐level, three‐factorial) was used to determine the effects of extraction solvent concentration (1–5 mg/mL), extraction solvent volume (5–15 mL), and extraction time (20–40 min) at a uniform ultrasonic power and temperature. In consequence, the best analyte extraction yields could be attained when the trehalose lipid solution concentration was prepared at 3 mg/mL, the trehalose lipid solution volume was 10 mL and the extraction time was set to 35 min. In addition, the recoveries of the antioxidants from Eucommia ulmoides leaves analyzed by this analytical method ranged from 98.2 to 102%. These results indicated that biosurfactant‐enhanced ultrasound‐assisted micellar extraction coupled with a simple ultra‐high‐performance liquid chromatography method could be effectively applied in the extraction and analysis of antioxidants from Eucommia ulmoides leaf samples.  相似文献   

3.
《Electrophoresis》2018,39(14):1771-1776
An ionic liquid‐based headspace in‐tube liquid‐phase microextraction (IL‐HS‐ITLPME) in‐line coupled with CE is proposed. The method is capable of quantifying trace amounts of phenols in environmental water samples. In the newly developed method, simply by placing a capillary injected with ionic liquids (IL) in the HS above the aqueous sample, volatile phenols were extracted into the IL acceptor phase in the capillary. After extraction, electrophoresis of the phenols in the capillary was carried out. Extraction parameters such as the extraction time, extraction temperature, ionic strength, volume of the sample solution, and IL types were systematically investigated. Under the optimized conditions, enrichment factors for four phenols were from 1510 to 1985. The proposed method provided a good linearity, low limits of detection (below 5.0 ng/mL), and good repeatability of the extractions (RSDs below 6.7%, n = 6). This method was then utilized to analyze two real environmental samples of Xiaoxi Lake and tap water, obtaining acceptable recoveries and precisions. Compared with the usual HS‐ITLPME for CE, IL‐HS‐ITLPME‐CE is a simple, low cost, fast, and environmentally friendly preconcentration technique.  相似文献   

4.
This work about the development of yttria‐based polymeric coating using [bis(hydroxyethyl) amine] terminated polydimethylsiloxanes and yttrium trimethoxyethoxide inside the capillary. The coated capillary was utilized for online capillary microextraction and high‐performance liquid chromatography analysis. The prepared coating material was characterized using scanning electron microscopy, X‐ray photoelectron spectroscopy, energy dispersive X‐ray spectrometry, and thermogravimetric analysis. The coated capillary with polymer presented better extraction efficiency compared with the pure yttria‐based coated capillary with applicability in extreme pH environments (pH 0–pH 14). Excellent extraction towards polyaromatic hydrocarbons, aldehydes, ketones, alcohols, phenols, and amides was observed with limit of detection ranging from 0.18 to 7.35 ng/mL (S/N = 3) and reproducibility in between 0.6 and 6.8% (n = 3). Capillary‐to‐capillary extraction analysis has presented reproducibility between 4.1 and 9.9%. The analysis provided linear response for seven selected phenols in the range of 5–200 ng/mL with R2 values between 0.9971 and 0.9998. The inter‐day, intra‐day, and capillary‐to‐capillary reproducibility for phenols was also <10%. Real sample analysis by spiking 5, 50, and 200 ng/mL of phenols in wastewater and pool‐water produced recovery between 84.7 and 94.3% and reproducibility within 7.6% (n = 3).  相似文献   

5.
A time‐saving method was applied to synthesize methyltrimethoxy‐modified magnetic mesoporous silica with or without p‐toluenesulfonic acid as the catalyst for magnetic solid‐phase extraction. The synthesized materials were systematically characterized. Results demonstrated that methyltrimethoxy modified magnetic mesoporous silica with p‐toluenesulfonic acid as the catalyst has a relatively smaller aperture and extreme hydrophobicity (water contact angle of 135°). To evaluate the feasibility of these prepared materials as effective adsorbents, it was combined with gas chromatography and electron capture detection to determine 26 polychlorinated biphenyls in environmental water. The result revealed that methyltrimethoxy modified magnetic mesoporous silica with p‐toluenesulfonic acid as the catalyst had the best extraction efficiency and recovery. Under the optimized extracted conditions, the proposed method showed good linearity within the concentration range of 5 to 200 ng/L with correlation coefficients of 0.9969 to 0.9999. The limits of detection and quantification based on signal‐to‐noise ratios of 3 and 10 were in the range of 0.16 to 0.91 and 0.52 to 3.0 ng/L, respectively. The polychlorinated biphenyl concentrations in environmental water samples were successfully determined using the developed method. PCB008 and PCB110 were 4.05 and 8.52 ng/L in Red‐Star lake water (Hubei Province, China), respectively.  相似文献   

6.
The separation of a compound of interest from its structurally similar homologues to produce high‐purity natural products is a challenging problem. This work proposes a novel method for the separation of iristectorigenin A from its structurally similar homologues by ionic‐liquid‐based ultrasound‐assisted extraction and the subsequent screening and isolation of potential α‐glucosidase inhibitors via ultrafiltration and semipreparative high‐performance liquid chromatography. Ionic‐liquid‐based ultrasound‐assisted extraction was successfully applied to the extraction of tectorigenin, iristectorigenin A, irigenin, and irisflorentin from Belamcanda chinensis . The optimum conditions for the efficient extraction of isoflavones were determined as 1.0 M 1‐ethyl‐3‐methylimidazolium tetrafluoroborate with extraction time of 30 min and a solvent to solid ratio of 30 mL/g. Ultrafiltration with liquid chromatography and mass spectrometry was applied to screen and identify α‐glucosidase inhibitors from B. chinensis , followed by the application of semipreparative high‐performance liquid chromatography to separate and isolate the active constituents. Four major compounds including tectorigenin, iristectorigenin A, irigenin, and irisflorentin were screened and identified as α‐glucosidase inhibitors, and then the four active compounds abovementioned were subsequently isolated by semipreparative high‐performance liquid chromatography (99.89, 88.97, 99.79, and 99.97% purity, respectively). The results demonstrate that ionic liquid extraction can be successfully applied to the extraction of isoflavones from B. chinensis .  相似文献   

7.
The total saccharides content of Lycium barbarum L. is very high, and a high temperature would result in saccharide decomposition and the emergence of a large amount of water. Moreover, the volatile compounds from the fruit of L. barbarum L. are rather low in concentration. Hence, it is difficult for a conventional headspace method to study the volatile compounds from the fruit of L. barbarum L. Since headspace‐trap gas chromatography with mass spectrometry is an excellent method for trace analysis, a headspace‐trap gas chromatography with mass spectrometry method based on low‐temperature (30°C) enrichment and multiple headspace extraction was developed to explore the volatile compounds from the fruit of L. barbarum L. The headspace of the sample was extracted in 17 cycles at 30°C. Each time, the compounds extracted were concentrated in the trap (Tenax TA and Tenax GR, 1:1). Finally, all the volatile compounds were delivered into the gas chromatograph after thermal desorption. With the method described above, a total of 57 compounds were identified. The identification was completed by mass spectral search, retention index, and accurate mass measurement.  相似文献   

8.
A simple, rapid, sensitive, and environmentally friendly method, based on modified dispersive liquid–liquid microextraction coupled with high‐performance liquid chromatography was developed for the simultaneous determination of five biogenic amines in fermented food samples. Biogenic amines were derivatized with 9‐fluorenylmethyl chloroformate, extracted by vortex‐assisted surfactant‐enhanced emulsification liquid–liquid microextraction, and then analyzed by high‐performance liquid chromatography. Five biogenic amine compounds were separated within 30 min using a C18 column and gradient elution with acetonitrile and 1% acetic acid. Factors influencing the derivatization and extraction efficiency such as type and volume of extraction solvent, type, and concentration of surfactant, pH, salt addition, and vortex time were optimized. Under the optimum conditions, the method provided the enrichment factors in the range of 161–553. Good linearity was obtained from 0.002–0.5 mg/L for cadaverine and tyramine, 0.003–1 mg/L for tryptamine and histamine, and 0.005–1 mg/L for spermidine with coefficient of determination (R2) > 0.992. The limits of detection ranged from 0.0010 to 0.0026 mg/L. The proposed method was successfully applied to analysis of biogenic amines in fermented foods such as fermented fish (plaa‐som), wine and beer where good recoveries were obtained in the range of 83.2–112.5%  相似文献   

9.
A rapid analytical method based on online solid‐phase extraction with high‐performance liquid chromatography and mass spectrometry has been established and applied to the determination of tannin compounds that may cause adverse effects in traditional Chinese medicine injections. Different solid‐phase extraction sorbents have been compared and the elution buffer was optimized. The performance of the method was verified by evaluation of recovery (≥40%), repeatability (RSD ≤ 6%), linearity (r2 ≥ 0.993), and limit of quantification (≤0.35 μg/mL). Five tannin compounds, gallic acid, cianidanol, gallocatechin gallate, ellagic acid, and penta‐O‐galloylglucose, were identified with concentrations ranging from 3.1–37.4 μg/mL in the analyzed traditional Chinese medicine injections.  相似文献   

10.
A broad forensic screening method for 256 analytes in whole blood based on a fully automated SPE robotic extraction and ultra‐high‐performance liquid chromatography (UHPLC) with TOF‐MS with data‐independent acquisition has been developed. The limit of identification was evaluated for all 256 compounds and 95 of these compounds were validated with regard to matrix effects, extraction recovery, and process efficiency. The limit of identification ranged from 0.001 to 0.1 mg/kg, and the process efficiency exceeded 50% for 73 of the 95 analytes. As an example of application, 1335 forensic traffic cases were analyzed with the presented screening method. Of these, 992 cases (74%) were positive for one or more traffic‐relevant drugs above the Danish legal limits. Commonly abused drugs such as amphetamine, cocaine, and frequent types of benzodiazepines were the major findings. Nineteen less frequently encountered drugs were detected e.g. buprenorphine, butylone, cathine, fentanyl, lysergic acid diethylamide, m‐chlorophenylpiperazine, 3,4‐methylenedioxypyrovalerone, mephedrone, 4‐methylamphetamine, p‐fluoroamphetamine, and p‐methoxy‐N‐methylamphetamine. In conclusion, using UHPLC–TOF‐MS screening with data‐independent acquisition resulted in the detection of common drugs of abuse as well as new designer drugs and more rarely occurring drugs. Thus, TOF‐MS screening of blood samples constitutes a practical way for screening traffic cases, with the exception of δ‐9‐tetrahydrocannabinol, which should be handled in a separate method.  相似文献   

11.
In this study, a novel technique is proposed for preparation of an efficient and unbreakable metal‐wire‐supported solid‐phase microextraction fiber. A sol–gel film was deposited on electrophoretically deposited carbon nanotubes on a stainless‐steel wire. The applicability of the fiber was evaluated through the extraction of some aromatic pollutants as model compounds from the headspace of aqueous samples in combination with gas chromatography and mass spectrometry. The parameters affecting the structure and extraction efficiency of the fiber (including the type of solvent, time, and potential for electrophoretic deposition) and the parameters affecting the extraction efficiency (such as coating type, salt content, extraction temperature, and time) were investigated. The results showed that the film thickness will be increased by increasing the potential and time duration. Finally, the characterization of the deposited film was accomplished by scanning electron microscopy and thermogravimetric analysis. After the optimization of the extraction parameters, the limit of detection of less than 20 pg/mL was achieved, and the calibration curves were all linear (r 2 ≥ 0.9737), in the range from 50 to 500 pg/mL. The solid‐phase microextraction fiber has a high mechanical strength; good stability and long service life, making it potentially applicable in the extraction of trace polycyclic aromatic hydrocarbons from aqueous samples.  相似文献   

12.
A novel ionic‐liquid‐based vortex‐simplified matrix solid‐phase dispersion method using 2,6‐dimethyl‐β‐cyclodextrin was established by ultra high performance liquid chromatography coupled with a photodiode array detector. 2,6‐Dimethyl‐β‐cyclodextrin was first used as a promising adsorbent in this proposed method for simultaneous determination of eight compounds in Gardeniae fructus. These compounds are terpenoids (geniposidic acid, genipin‐1‐β‐D‐gentiobioside, geniposide, 8‐o‐acetyl shanzhiside methyl ester), crocins (crocin‐I, crocin‐II), quinic acid derivatives (chlorogenic acid), and flavonoids (isoquercitrin), respectively. Several parameters were investigated in the adsorption and desorption processes to obtain the optimal conditions, including 2,6‐dimethyl‐β‐cyclodextrin as sorbent, 0.5 mL 100 mM 1‐dodecyl‐3‐methylimidazolium hydrogen sulfate as the extraction solvent, 2:1 of sample/sorbent ratio, grinding for 2 min and vortexing for 60 s. The recoveries of the eight compounds ranged from 96.6 to 100% (<3.50%). The limits of detection and quantification were in the range of 0.02–0.30 and 0.06–1.25  μg/mL, respectively. Meanwhile, a good linearity was attained with r values (>0.9997). The established method showed higher extraction efficiency and less reagent consumption than traditional matrix solid phase dispersion and ultrasonic‐assisted extraction. Hence, it could be applied for sample preparation and analysis of natural products.  相似文献   

13.
The frankincense resins, secreted from Boswellia species, are an uncommon example of a natural raw material where every class of terpenoids is present in similar proportions. Diterpenoids (serratol, incensole, and incensole acetate) are used to discriminate samples from different species and origins. Headspace solid‐phase microextraction has been used for frankincense analysis, although it requires long sampling time for medium‐ to low‐volatility markers; headspace solid‐phase microextraction under vacuum can overcome this limit. Gas chromatography is used for analysis but the separation of incensole and serratol needs polar stationary phases. In this study, we develop a method to discriminate frankincenses based on vacuum‐assisted headspace solid‐phase microextraction combined with fast gas chromatography‐mass spectrometry with ionic liquid–based stationary phases. The optimized conditions for solid samples were: air evacuation below 0°C, 15 min of incubation time, and 15 min of extraction time. Losses of volatiles due to vial air‐evacuation in the presence of the sample were minimized by sample amount above 100 mg and low sample temperature. Fast gas chromatography provides the baseline separation of all markers in 20 min. By applying vacuum sampling and fast gas chromatography, the total analysis was reduced to 50 min compared to 120 min (60 min sampling plus 60 min analysis) as previously reported. The method was successfully applied to commercial frankincense samples.  相似文献   

14.
Xanthii fructus (XF), the fruit of Xanthium sibiricum Patr., is a traditional Chinese materia medica commonly used to treat allergic rhinitis and other rhinitis diseases. To uncover the mechanism of the stir‐frying process and its effect on the pharmacokinetic behavior of active compounds in model rats, four active compounds—chlorogenic acid, 4‐caffeoylquinic acid, 1,5‐O‐dicaffeoylquinic acid and apigenin—were selected based on previous spectrum‐effect experiments. High performance liquid chromatography tandem triple quadrupole mass spectrometry (UPLC–QqQ–MS) technology, an accurate and feasible method, was applied to measure the concentration of these four compounds in rat plasma. This validated method can accurately measure the concentration of each compound at each sampling point of rat plasma. This validated method shows good linearity, extraction recoveries, matrix effects, intra‐ and inter‐day precision and stabilities. Compared with the XF group, the maximum plasma concentration (Cmax) value of 1,5‐O‐dicaffeoylquinic acid decreased remarkably (p < 0.05) after oral administration of stir‐fried Xanthii fructus (SXF) extract, while the other compounds showed no significant difference. The mean residence time value of chlorogenic acid (p < 0.05) and 1,5‐O‐dicaffeoylquinic acid (p<0.01) after oral administration of SXF extraction demonstrated significant differences compared with the XF group, while the other two compounds showed no statistical difference, indicating that the stir‐frying process prolonged the effect time and delayed the removal time of chlorogenic acid and 1,5‐O‐dicaffeoylquinic acid. The values of the area under the plasma concentration–time curve from zero to the last quantifiable time‐point, the area under the plasma concentration–time curve from zero to infinity, the time to maximum concentration and the elimination half‐life of four compounds in the SXF group showed no statistically significant difference from the XF group. From this data, we speculated that the stir‐frying process can not only keep the absorption of 4‐caffeoylquinic acid and apigenin, but also increase the effect time of chlorogenic acid and 1,5‐O‐dicaffeoylquinic acid, which could be the mechanism underlying the stir‐frying process enhancing the effects of XF.  相似文献   

15.
A hyphenated strategy by off‐line coupling of 1,1′‐diphenyl‐2‐picrylhydrazyl‐high‐performance liquid chromatography, high‐speed countercurrent chromatography, and preparative high‐performance liquid chromatography was established to screen and separate antioxidants from ethyl acetate fraction of the roots of Polygonum multiflorum. Under the targeted guidance of 1,1′‐diphenyl‐2‐picrylhydrazyl‐high‐performance liquid chromatography experiment, 12 compounds were identified as potential antioxidants and readily isolated by high‐speed counter‐current chromatography and preparative high‐performance liquid chromatography. Ultraviolet spectroscopy, mass spectrometry, and 1H NMR spectroscopy were employed to identify their structures, which were assigned as gallic acid ( 1 , 6.2 mg, 98.28%), catechin ( 2 , 8.8 mg, 90.69%), epicatechin ( 3 , 4.1 mg, 96.71%), polydatin ( 4 , 5.3 mg, 94.91%), 2,3,5,4′‐tetrahydroxy stilbene‐2‐Οβ‐D‐glucoside ( 5 , 20.2 mg, 95.23%), piceatannol ( 6 , 5.3 mg, 96.85%), rutin ( 7 , 5.4 mg, 97.92%), resveratrol ( 8 , 5.2 mg, 96.94%), isorhapontigenin ( 9 , 11.4 mg, 94.81%), hyperoside ( 10 , 9.7 mg, 98.52%), rhein ( 11 , 4.9 mg, 97.46%), and emodin ( 12 , 8.2 mg, 95.74%). Notably, compounds 6 and 9 were isolated from Polygonum multiflorum for the first time. In addition, antioxidant activity of compounds 1–12 were evaluated, and compounds 1–8 and 10 exhibited stronger antioxidant activity than ascorbic acid (positive control). These results indicated that the proposed method is a highly efficient strategy to screen and isolate antioxidants from complex natural products.  相似文献   

16.
A readily applicable method was developed to determine the concentration level of zaltoprofen, a non‐steroidal antiinflammatory drug from the propionic acid family, in human plasma. This method is based on manual‐shaking‐assisted dispersive liquid–liquid microextraction coupled with liquid chromatography with ultraviolet detection. Factors affecting the extraction efficiency were screened and optimized by experimental design using fractional factorial and central composite designs, respectively. Optimal conditions were: 220 μL of C2H4Cl2 (extraction solvent), 5 mL of 3.75% w/v NaCl aqueous solution at pH 2.0, and manual shaking for 13 s (65 times). The resulting extraction method yielded a reasonable enrichment factor of 18.0 (±0.6, = 3) and extraction recovery of 86.0% (±3.3%, = 3). The established method was validated for selectivity, linearity, precision, accuracy, matrix effect, recovery, dilution integrity, and stability, and it met the acceptable criteria for all of the tested parameters. Specifically, the method was linear in the range of 0.16–50.0 mg/L, precise (< 8.8% RSD), accurate (–7.5–5.6% deviation), and showed negligible matrix effects (96.1–106.4%) with high absolute recovery (94.5–97.7%). Compared with previous methods involving labor‐intensive liquid–liquid extraction or non‐specific protein precipitation, our method allows the simple, rapid, and efficient determination of zaltoprofen using the most affordable analytical instrument, liquid chromatography with ultraviolet detection.  相似文献   

17.
In this study, we have developed a method to assess adenosine 5?‐triphosphate by adsorptive extraction using surface adenosine 5′‐triphosphate‐imprinted polymer over polystyrene nanoparticles (412 ± 16 nm) for selective recognition/separation from urine. Molecularly imprinted polymer was synthesized by emulsion copolymerization reaction using adenosine 5′‐triphosphate as a template, functional monomers (methacrylic acid, N‐isopropyl acrylamide, and dimethylamino ethylmethacrylate) and a crosslinker, methylenebisacrylamide. The binding capacities of imprinted and non‐imprinted polymers were measured using high‐performance liquid chromatography with UV detection with a detection limit of 1.6 ± 0.02 µM of adenosine 5′‐triphosphate in the urine. High binding affinity (QMIP, 42.65 µmol/g), and high selectivity and specificity to adenosine 5′‐triphosphate compared to other competitive nucleotides including adenosine 5?‐diphosphate, adenosine 5?‐monophosphate, and analogs such as adenosine, adenine, uridine, uric acid, and creatinine were observed. The imprinting efficiency of imprinted polymer is 2.11 for urine (QMIP, 100.3 µmol/g) and 2.51 for synthetic urine (QMIP, 48.5 µmol/g). The extraction protocol was successfully applied to the direct extraction of adenosine 5′‐triphosphate from spiked human urine indicating that this synthesized molecularly imprinted polymer allowed adenosine 5′‐triphosphate to be preconcentrated while simultaneously interfering compounds were removed from the matrix. These submicron imprinted polymers over nano polystyrene spheres have a potential in the pharmaceutical industries and clinical analysis applications.  相似文献   

18.
A new analytical method for the simultaneous determination of trace levels of seven prohibited N‐nitrosamines (N‐nitrosodimethylamine, N‐nitrosoethylmethylamine, N‐nitrosopyrrolidine, N‐nitrosodiethylamine, N‐nitrosopiperidine, N‐nitrosomorpholine, and N‐nitrosodiethanolamine) in cosmetic products has been developed. The method is based on vortex‐assisted reversed‐phase dispersive liquid–liquid microextraction, which allows the extraction of highly polar compounds, followed by liquid chromatography with mass spectrometry. The variables involved in the extraction process were studied to obtain the highest enrichment factor. Under the selected conditions, 75 μL of water as extraction solvent was added to 5 mL of n‐hexane sample solution and assisted by vortex mixing during 30 s to form the cloudy solution. The method was successfully validated showing good linearity (0.5–50 ng/mL), enrichment factors up to 65 depending on the target compound, limits of detection values of 1.8–50 ng/g, and good repeatability (RSD < 9.8%). Finally, the proposed method was applied to different cosmetic samples. Quantitative relative recovery values (80–113%) were obtained, thus showing that matrix effects were negligible. The achieved analytical features of the proposed method, besides of its simplicity and affordability, make it useful to perform the quality control of cosmetic products to ensure the safety of consumers.  相似文献   

19.
A new facile magnetic micro‐solid‐phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite‐MCM‐41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite‐MCM‐41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05–500 μg/L (r 2 = 0.996–0.999). Good limits of detection (0.008–0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n  = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1–115.4%. Results indicate that magnetite micro‐solid‐phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.  相似文献   

20.
A new highly sensitive and environmentally friendly analytical method, using low‐temperature partition extraction and ultra‐high‐performance liquid chromatography with tandem mass spectrometry, without the use of a labeled analyte, was developed and validated to determine and quantify urinary S‐phenylmercapturic acid in urine samples. The World Health Organization, in its guidelines for air quality in Europe, recognizes that benzene is carcinogenic to humans and there is no safe level of exposure. Urinary S‐phenylmercapturic acid is a sensitive and specific biological marker of exposure to benzene. The new analytical method, extraction, and analysis, were linear in the working range between 0.1 and 200.0 μg/L, precise (relative standard deviation lower than 6.0%), accurate (97.0–105.0%), and sensitive. The method's limits of detection and quantification were 0.02 and 0.084 μg/L, respectively. The recovery with the low‐temperature partition extraction was 96.1%, with relative standard deviation less than 3.8%. The method is simple, accurate, and reproducible, and has been successfully applied in the evaluation of nonoccupational exposure to benzene, by urinary S‐phenylmercapturic acid in urine samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号