首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For the first time, the high‐density solvent‐based solvent de‐emulsification dispersive liquid–liquid microextraction (HSD‐DLLME) was developed for the fast, simple, and efficient determination of chlorophenols in water samples followed by field‐enhanced sample injection with reverse migrating micelles in CE. The extraction of chlorophenols in the aqueous sample solution was performed in the presence of extraction solvent (chloroform) and dispersive solvent (acetone). A de‐emulsification solvent (ACN) was then injected into the aqueous solution to break up the emulsion, the obtained emulsion cleared into two phases quickly. The lower layer (chloroform) was collected and analyzed by field‐enhanced sample injection with reverse migrating micelles in CE. Several important parameters influencing the extraction efficiency of HSD‐DLLME such as the type and volume of extraction solvent, disperser solvent and de‐emulsification solvent, sample pH, extraction time as well as salting‐out effects were optimized. Under the optimized conditions, the proposed method provided a good linearity in the range of 0.02–4 μg/mL, low LODs (4 ng/mL), and good repeatability of the extractions (RSDs below 9.3%, n = 5). And enrichment factors for three phenols were 684, 797, and 233, respectively. This method was then utilized to analyze two real environmental samples from wastewater and tap water and obtained satisfactory results. The obtained results indicated that the developed method is an excellent alternative for the routine analysis in the environmental field.  相似文献   

2.
A simple in‐line single drop liquid–liquid–liquid microextraction (SD‐LLLME) coupled with CE for the determination of two fluoroquinolones was developed. The method is capable to quantify trace amount of analytes in water samples and to improve the sensitivity of CE detection. For the SD‐LLLME, a thin layer of organic phase was used to separate a drop of 0.1 M NaOH hanging at the inlet of the capillary from the aqueous donor phase. By this way, the analytes were extracted to the acceptor phase through the organic layer based on their acidic/basic dissociation equilibrium. The drop was immersed into the organic phase during 10 min for extraction and then it is directly injected into the capillary for the analysis. Parameters such as type and volume of organic solvent phase, aqueous donor, and acceptor phases and extraction time and temperature were optimized. The enrichment factor was calculated, resulting 40‐fold for enrofloxacin (ENR) and sixfold for ciprofloxacin (CIP). The linear range were 20–400 μg/L for ENR and 60–400 μg/L for CIP. The detection limits were 10.1 μg/L and 55.3 μg/L for ENR and CIP, respectively, and a good reproducibility was obtained (4.4% for ENR and 5.6% for CIP). Two real water samples were analysed applying the new method and the obtained results presented satisfactory recovery percentages (90–100.3%).  相似文献   

3.
An ionic liquid-based single-drop microextraction (IL-SDME) procedure using IL as an extractant on-line coupled to capillary electrophoresis (CE) is proposed. The method is capable of quantifying trace amounts of phenols in environmental water samples. For the SDME of three phenols, a 2.40 nL IL microdrop was exposed for 10 min to the aqueous sample and then was directly injected into the capillary column for analysis. Extraction parameters such as the extraction time, the IL single-drop volume, pH of the sample solution, ionic strength, volume of the sample solution and the extraction temperature were systematically investigated. Detection limits to three phenols were less than 0.05 μg mL−1, and their calibration curves were all linear (R2 ≥ 0.9994) in the range from 0.05 to 50 μg mL−1. And enrichment factors for three phenols were 156, 107 and 257 without agitation, respectively. This method was then utilized to analyze two real environmental samples from Yellow River and tap water, obtaining satisfactory results. Compared with the usual SDME for CE, IL-SDME–CE is a simple, low-cost, fast and environmentally friendly preconcentration technique.  相似文献   

4.
A rapid liquid phase extraction employing a novel hydrophobic surfactant‐based room temperature ionic liquid (RTIL), tetrabutylphosphonium dioctyl sulfosuccinate ([4C4P][AOT]), coupled with capillary electrophoretic‐UV (CE‐UV) detection is developed for removal and determination of phenolic compounds. The long‐carbon‐chain RTIL used is sparingly soluble in most solvents and can be used to replace volatile organic solvents. This fact, in combination with functional‐surfactant‐anions, is proposed to reduce the interfacial energy of the two immiscible liquid phases, resulting in highly efficient extraction of analytes. Several parameters that influence the extraction efficiencies, such as extraction time, RTIL type, pH value, and ionic strength of aqueous solutions, were investigated. It was found that, under acidic conditions, most of the investigated phenols were extracted from aqueous solution into the RTIL phase within 12 min. Good linearity was observed over the concentration range of 0.1–80.0 μg/mL for all phenols investigated. The precision of this method, expressed as RSD, was determined to be within 3.4–5.3% range. The LODs (S/N = 3) of the method were in the range of 0.047–0.257 μg/mL. The proposed methodology was successfully applied to determination of phenols in real water samples.  相似文献   

5.
This article describes a new, rapid and sensitive method for the determination of chlorotoluron, diethofencarb and chlorbenzuron from water samples with temperature‐controlled ionic liquid‐dispersive liquid‐phase microextraction. In the preconcentration procedure, ionic liquid 1‐hexyl‐3‐methylimidazolium hexafluorophosphate [C6MIM] [PF6] was employed as the extraction solvent. The parameters, such as volume of [C6MIM] [PF6], sample pH, extraction time, centrifuging time, temperature and salting‐out effect, were investigated in detail. Under the optimal extraction conditions, it has been found that three analytes had excellent LODs (S/N=3) in the range of 0.04–0.43 μg/L. The RSDs (n=6) were in the range of 1.3–4.7%. The proposed method was evaluated with lake water, tap water and melted snow water samples. The experimental results indicated that the proposed method had excellent prospect and would be widely used in the future.  相似文献   

6.
In this study, a green, rapid, and simple method, ionic‐liquid‐magnetized stirring bar liquid‐phase microextraction was developed for the determination of naphthoquinones, including shikonin and β,β′‐dimethylacrylshikonin, in Zicao. This method permits active magnetic stirring, extraction, and pre‐enrichment in a single device simultaneously, so the extract is conveniently collected. The analytes were extracted from the sample to ionic liquid‐magnetized stirring bar, then the analyte‐adsorbed magnetized stirring bar can be readily isolated from the sample solution by a magnet. The key experimental parameters were investigated and optimized, including the type and volume of ionic liquid, extraction time, salt concentration, stirring speed, and pH. The recoveries were in the range of 89.47–102.38%, and good reproducibilities were obtained with relative standard deviation below 5.36%. Compared with the conventional extraction methods, the proposed method is quicker and more effective.  相似文献   

7.
An easy, quick, and green method, microwave‐assisted liquid–liquid microextraction based on solidification of ionic liquid, was first developed and applied to the extraction of sulfonamides in environmental water samples. 1‐Ethy‐3‐methylimidazolium hexafluorophosphate, which is a solid‐state ionic liquid at room temperature, was used as extraction solvent in the present method. After microwave irradiation for 90 s, the solid‐state ionic liquid was melted into liquid phase and used to finish the extraction of the analytes. The ionic liquid and sample matrix can be separated by freezing and centrifuging. Several experimental parameters, including amount of extraction solvent, microwave power and irradiation time, pH of sample solution, and ionic strength, were investigated and optimized. Under the optimum experimental conditions, good linearity was observed in the range of 2.00–400.00 μg/L with the correlation coefficients ranging from 0.9995 to 0.9999. The limits of detection for sulfathiazole, sulfachlorpyridazine, sulfamethoxazole, and sulfaphenazole were 0.39, 0.33, 0.62, and 0.85 μg/L, respectively. When the present method was applied to the analysis of environmental water samples, the recoveries of the analytes ranged from 75.09 to 115.78% and relative standard deviations were lower than 11.89%.  相似文献   

8.
A sensitive method for the determination of mexiletine and lidocaine using surfactant‐assisted dispersive liquid–liquid microextraction coupled with capillary electrophoresis was developed. Triton X‐100 and dichloromethane were used as the dispersive agent and extraction solvent, respectively. After the extraction, mexiletine and lidocaine were analyzed using capillary electrophoresis with ultraviolet detection. The detection sensitivity was further enhanced through the use of field‐amplified sample stacking. Under optimal extraction and stacking conditions, the calibration curves were linear over a concentration range of 0.05–1.00 μM for mexiletine and 0.03–1.00 μM for lidocaine. The limits of detection (signal‐to‐noise ratio of 3) were 0.01 and 0.01 μM for mexiletine and lidocaine, respectively. An approximately 1141‐ to 1250‐fold improvement in sensitivity was observed for the two analytes compared with the injection of a standard solution without the surfactant‐assisted dispersive liquid–liquid microextraction and field‐amplified sample stacking procedures. This developed method was successfully applied to the determination of mexiletine and lidocaine in human urine and serum samples. Both precision and accuracy for urine and serum samples were less than 8.7 and 6.7%, respectively. The recoveries of the two analytes from urine and serum samples were 54.7–64.9% and 16.1–56.5%, respectively.  相似文献   

9.
In this work, a simple, fast, sensitive, and environmentally friendly method was developed for preconcentration and quantitative measurement of bisphenol A in water samples using gas chromatography with mass spectrometry. The preconcentration approach, namely biosorption‐based dispersive liquid‐liquid microextraction with extractant removal by magnetic nanoparticles was performed based on the formation of microdroplet of rhamnolipid biosurfactant throughout the aqueous samples, which accelerates the mass transfer process between the extraction solvent and sample solution. The process is then followed by the application of magnetic nanoparticles for easy retrieval of the analyte‐containing extraction solvent. Several important variables were optimized comprehensively including type of disperser solvent and desorption solvent, rhamnolipid concentration, volume of disperser solvent, amount of magnetic nanoparticles, extraction time, desorption time, ionic strength, and sample pH. Under the optimized microextraction and gas chromatography with mass spectrometry conditions, the method demonstrated good linearity over the range of 0.5–500 µg/L with a coefficient of determination of R= 0.9904, low limit of detection (0.15 µg/L) and limit of quantification (0.50 µg/L) of bisphenol A, good analyte recoveries (84–120%) and acceptable relative standard deviation (1.8–14.9%, = 6). The proposed method was successfully applied to three environmental water samples, and bisphenol A was detected in all samples.  相似文献   

10.
Task‐specific ionic liquid‐based ultrasound‐assisted dispersive liquid–liquid microextraction was used for the preconcentration of cadmium(II), cobalt(II), and lead(II) ions in tea samples, which were subsequently analyzed by liquid chromatography with UV detection. The proposed method of preconcentration is free of volatile organic compounds, which are often used as extractants and dispersing solvents in classic techniques of microextraction. A task‐specific ionic liquid trioctylmethylammonium thiosalicylate was used as an extractant and a chelating agent. Ultrasound was used to disperse the ionic liquid. After microextraction, the phases were separated by centrifugation, and the ionic liquid phase was solubilized in methanol and directly injected into the liquid chromatograph. Selected microextraction parameters, such as the volume of ionic liquid, the pH of the sample, the duration of ultrasound treatment, the speed and time of centrifugation, and the effect of ionic strength, were optimized. Under optimal conditions an enrichment factor of 200 was obtained for each analyte. The limits of detection were 0.002 mg/kg for Cd(II), 0.009 mg/kg for Co(II), and 0.013 mg/kg for Pb(II). The accuracy of the proposed method was evaluated by an analysis of the Certified Reference Materials (INCT‐TL‐1, INCT‐MPH‐2) with the recovery values in the range of 90–104%.  相似文献   

11.
The determination of 15 pyrethroids in soil and water samples was carried out by gas chromatography with mass spectrometry. Compounds were extracted from the soil samples (4 g) using solid–liquid extraction and then salting‐out assisted liquid–liquid extraction. The acetonitrile phase obtained (0.8 mL) was used as a dispersant solvent, to which 75 μL of chloroform was added as an extractant solvent, submitting the mixture to dispersive liquid–liquid microextraction. For the analysis of water samples (40 mL), magnetic solid‐phase extraction was performed using nanocomposites of magnetic nanoparticles and multiwalled carbon nanotubes as sorbent material (10 mg). The mixture was shaken for 45 min at room temperature before separation with a magnet and desorption with 3 mL of acetone using ultrasounds for 5 min. The solvent was evaporated and reconstituted with 100 μL acetonitrile before injection. Matrix‐matched calibration is recommended for quantification of soil samples, while water samples can be quantified by standards calibration. The limits of detection were in the range of 0.03–0.5 ng/g (soil) and 0.09–0.24 ng/mL (water), depending on the analyte. The analyzed environmental samples did not contain the studied pyrethroids, at least above the corresponding limits of detection.  相似文献   

12.
A novel microextraction method, termed microwave‐assisted ionic liquid/ionic liquid dispersive liquid–liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high‐performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1‐hexyl‐3‐methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1‐hexyl‐3‐methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1‐butyl‐3‐methylimidazolium tetrafluoroborate. In addition, an ion‐pairing agent (NH4PF6) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00–250.00 μg/L, with the correlation coefficients of 0.9982–0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7–105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples.  相似文献   

13.
A novel design of hollow‐fiber liquid‐phase microextraction containing multiwalled carbon nanotubes as a solid sorbent, which is immobilized in the pore and lumen of hollow fiber by the sol–gel technique, was developed for the pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples. The proposed method utilized both solid‐ and liquid‐phase microextraction media. Parameters that affect the extraction of polycyclic aromatic hydrocarbons were optimized in two successive steps as follows. Firstly, a methodology based on a quarter factorial design was used to choose the significant variables. Then, these significant factors were optimized utilizing central composite design. Under the optimized condition (extraction time = 25 min, amount of multiwalled carbon nanotubes = 78 mg, sample volume = 8 mL, and desorption time = 5 min), the calibration curves showed high linearity (R 2 = 0.99) in the range of 0.01–500 ng/mL and the limits of detection were in the range of 0.007–1.47 ng/mL. The obtained extraction recoveries for 10 ng/mL of polycyclic aromatic hydrocarbons standard solution were in the range of 85–92%. Replicating the experiment under these conditions five times gave relative standard deviations lower than 6%. Finally, the method was successfully applied for pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples.  相似文献   

14.
A novel dispersive liquid‐phase microextraction method without dispersive solvents has been developed for the enrichment and sensitive determination of triclosan and triclocarban in environmental water samples prior to HPLC‐ESI‐MS/MS. This method used only green solvent 1‐hexyl‐3‐methylimidazolium hexafluorophosphate as extraction solvent and overcame the demerits of the use of toxic solvents and the instability of the suspending drop in single drop liquid‐phase microextraction. Important factors that may influence the enrichment efficiencies, such as volume of ionic liquid, pH of solutions, extraction time, centrifuging time and temperature, were systematically investigated and optimized. Under optimum conditions, linearity of the method was observed in the range of 0.1–20 μg/L for triclocarban and 0.5–100 μg/L for triclosan, respectively, with adequate correlation coefficients (R>0.9990). The proposed method has been found to have excellent detection sensitivity with LODs of 0.04 and 0.3 μg/L, and precisions of 4.7 and 6.0% (RSDs, n=5) for triclocarban and triclosan, respectively. This method has been successfully applied to analyze real water samples and satisfactory results were achieved.  相似文献   

15.
An automated three‐phase hollow fiber liquid‐phase microextraction based on two immiscible organic solvents followed by high‐performance liquid chromatography with UV–Vis detection method was applied for the extraction and determination of exemestane, letrozole, and paclitaxel in water and urine samples. n‐Dodecane was selected as the supported liquid membrane and its polarity was justified by trioctylphosphine oxide. Acetonitrile was used as an organic acceptor phase with desirable immiscibility having n‐dodecane. All the effective parameters of the microextraction procedure such as type of the organic acceptor phase, the supported liquid membrane composition, extraction time, pH of the donor phase, hollow fiber length, stirring rate, and ionic strength were evaluated and optimized separately by a one variable at‐a‐time method. Under the optimal conditions, the linear dynamic ranges were 1.8–200 (R2 = 0.9991), 0.9–200 (R2 = 0.9987) and 1.2–200 μg/L (R2 = 0.9983), and the limits of detection were 0.6, 0.3, and 0.4 μg/L for exemestane, letrozole, and paclitaxel, respectively. To evaluate the capability of the proposed method in the analysis of biological samples, three different urinary samples were analyzed under the optimal conditions. The relative recoveries of the three pharmaceuticals were in the range of 91–107.3% for these three analytes.  相似文献   

16.
The present work describes a simple route to magnetize MIL‐53(Al)‐NH2 sorbent for rapid extraction of phenol residues from environmental samples. To extend the applications and performances of the metal‐organic frameworks in the field of adsorption materials, we combined the properties of metal‐organic frameworks and magnetite to decrease the extraction time and simplify the extraction process as well. In this study, a simple and quick vortex‐assisted dispersive magnetic solid phase extraction method for the extraction of ten United States Environmental Protection Agency's priority phenols from water samples prior to analysis by high‐performance liquid chromatography with photodiode array detection was proposed. The developed method exhibits a rapid enrichment of the target analytes within 10 s for extraction and 10 s for desorption. Low detection limits of 1.8‐41.7 µg/L and quantitation limits of 6.0‐139.0 µg/L with the relative standard deviations for intra‐ and interday analyses less than 12% were achieved. Satisfactory recoveries in the range of 80‐111% with the relative standard deviations less than 11% demonstrated that Fe3O4/MIL‐53(Al)‐NH2 is promising sorbent in the field of magnetic solid‐phase extraction for environmental samples.  相似文献   

17.
A hydroxyl‐functionalized ionic liquid, 1‐hydroxyethyl‐3‐methylimidazolium bis(trifluoromethanesulfonyl)imide, was employed in an improved dispersive liquid‐phase microextraction method coupled with ultra high performance liquid chromatography for the enrichment and determination of three estrogens and bisphenol A in environmental water samples. The introduced hydroxyl group acted as the H‐bond acceptor that dispersed the ionic liquid effectively in the aqueous phase without dispersive solvent or external force. Fourier transform infrared spectroscopy indicated that the hydroxyl group of the cation of the ionic liquid enhanced the combination of extractant and analytes through the formation of hydrogen bonds. The improvement of the extraction efficiency compared with that with the use of alkyl ionic liquid was proved by a comparison study. The main parameters including volume of extractant, temperature, pH, and extraction time were investigated. The calibration curves were linear in the range of 5.0–1000 μg/L for estrone, estradiol, and bisphenol A, and 10.0–1000 μg/L for estriol. The detection limits were in the range of 1.7–3.4 μg/L. The extraction efficiency was evaluated by enrichment factor that were between 85 and 129. The proposed method was proved to be simple, low cost, and environmentally friendly for the determination of the four endocrine disruptors in environmental water samples.  相似文献   

18.
Simultaneous derivatization and air‐assisted liquid–liquid microextraction using an organic that is solvent lighter than water has been developed for the extraction of some parabens in different samples with the aid of a newly designed device for collecting the extractant. For this purpose, the sample solution is transferred into a glass test tube and a few microliters of acetic anhydride (as a derivatization agent) and p‐xylene (as an extraction solvent) are added to the solution. After performing the procedure, the homemade device consists of an inverse funnel with a capillary tube placed into the tube. In this step, the collected extraction solvent and a part of the aqueous solution are transferred into the device and the organic phase indwells in the capillary tube of the device. Under the optimal conditions, limits of detection and quantification for the analytes were obtained in the ranges of 0.90–2.7 and 3.0–6.1 ng/mL, respectively. The enrichment and enhancement factors were in the ranges of 370–430 and 489–660, respectively. The method precision, expressed as the relative standard deviation, was within the range of 4–6% (= 6) and 4–9% (= 4) for intra‐ and interday precisions, respectively. The proposed method was successfully used for the determination of methyl‐, ethyl‐, and propyl parabens in cosmetic, hygiene and food samples, and personal care products.  相似文献   

19.
In this study, for the first time, salt‐assisted liquid–liquid extraction was performed in a microchannel system. The proposed design is based on the increase of contact surface area between target analytes and extracting phase during the sample and extracting phase transfer in microchannel. In this method, first sample solution, extracting solvent, and salt were mixed by stirrer and simultaneously delivered into a microchannel using a syringe pump. In order to optimize the influential parameters on the extraction efficiency of the proposed method, zidovudine and tenofovir disoproxil fumarate were selected as model analytes. The main parameters such as extracting solvent and its volume, salt amount, pH of sample solution, and microchannel shape, length, and its inner diameter were investigated and optimized. Under the optimized conditions, the proposed method was linear in the range of 0.1–30 µg/mL and R2 coefficients were equal to 0.9922 and 0.9947 for zidovudine and tenofovir disoproxil fumarate, respectively. Extraction efficiency of the proposed method was compared with conventional salt‐assisted liquid–liquid extraction. The results show that the proposed design has higher extraction efficiency than conventional salt‐assisted liquid–liquid extraction. Finally, the proposed method was successfully applied for the determination of zidovudine and tenofovir disoproxil fumarate in plasma samples.  相似文献   

20.
An environmentally friendly ionic liquids dispersive liquid–liquid microextraction (IL‐DLLME) method coupled with high‐performance liquid chromatography (HPLC) for the determination of antihypertensive drugs irbesartan and valsartan in human urine samples was developed. The HPLC separations were accomplished in less than 10 min using a reversed‐phase C18 column (250 × 4.60 mm i.d., 5 µm) with a mobile phase containing 0.3 % formic acid solution and methanol (v/v, 3:7; flow rate, 1.0 mL/min). UV absorption responses at 236 nm were linear over a wide concentration range from 50 µg/mL to the detection limits of 3.3 µg/L for valsartan and 1.5 µg/L for irbesartan. The effective parameters on IL‐DLLME, such as ionic liquid types and their amounts, disperser solvent types and their volume, pH of the sample and extraction time were studied and optimized. The developed IL‐DLLME‐HPLC was successfully applied for evaluation of the urine irbesartan and valsartan profile following oral capsules administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号