首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Amphiphilic graft copolymers having ultrahigh molecular weight poly(styrene-alt-maleic anhydride) (SMA) backbones and methoxyl poly(ethylene glycol) (MPEG) grafts were synthesized via the esterification between anhydride groups with hydroxyl groups. The synthesized graft copolymers, SMA-g-MPEGs, were used as additives in the preparation of polyethersulfone (PES) membranes via phase inversion process. X-ray photoelectron spectroscopy (XPS) analysis showed the comb-like graft copolymers spontaneously segregated to membrane surface during membrane formation. Water contact angle measurements and water absorbance experiments indicated the PES/SMA-g-MPEG blend membranes were much more hydrophilic than pure PES membrane. The blend membranes had stronger protein adsorption resistance than pure PES membrane did. After washed using de-ionized water for 25 days, the blend membranes exhibited higher hydrophilicity and stronger protein adsorption resistance. This phenomenon was attributed to the further accumulation of SMA-g-MPEG additives on membrane surface in aqueous conditions. SMA-g-MPEGs can be well preserved in membrane near-surface and not lost during membrane washing due to their high molecular weight and comb-like architecture.  相似文献   

2.
Hydrophilic modification of ultrafiltration membranes was achieved through blending of Pluronic F127 with poly(ether sulfone) (PES). The chemical composition and morphology changes of the membrane surface were confirmed by water contact angle, X-ray photoelectron spectroscopy, scanning electron microscopy, and protein adsorption measurements. The decreased static water contact angle with an increase in the Pluronic F127 content indicated an increase of surface hydrophilicity. XPS analysis revealed enrichment of PEO segments of Pluronic F127 at the membrane surface. The apparent protein adsorption amount decreased significantly from 56.2 to 0 microg/cm(2) when the Pluronic F127 content varied from 0% to 10.5%, which indicated that the blend membrane had an excellent ability to resist protein adsorption. The ultrafiltration experiments revealed that the Pluronic F127 content had little influence on the protein rejection ratio and pure water flux. Most importantly, at a high Pluronic F127 content membrane fouling, especially irreversible fouling, has been remarkably reduced. The flux recoveries of blend membranes reached as high as 90% after periodic cleaning in three cycles.  相似文献   

3.
A novel TiO2 nanoparticle self-assembly membrane was prepared based on ultrahigh molecular weight poly(styrene-alt-maleic anhydride)/poly(vinylidene fluoride) (SMA/PVDF) blend membrane. TiO2 nanoparticle solution was beforehand prepared via the controlled hydrolysis of titanium tetraisopropoxide. The diameter (10 nm or less) and anatase crystal structure were analyzed using transmission electron microscopy (TEM) and X-ray diffraction (XRD). The SMA/PVDF blend membranes prepared by the phase inversion method were immersed into the TiO2 nanoparticle solution for a week to produce TiO2 self-assembly membranes. The chemical compositions in membrane surface were analyzed by X-ray photoelectron spectroscopy (XPS). The membrane morphologies were measured by scanning electron microscopy (SEM). Finally, the membrane hydrophilicity, protein anti-fouling property and the molecular weight cutoff (MWCO) were characterized by water contact angle measurement, static protein absorption and filtration experiments, respectively. It is demonstrated that, in comparison to PVDF/SMA blend membrane, the permeability and anti-fouling ability of TiO2 self-assembly membranes were significantly improved.  相似文献   

4.
Hyperbranched polyester-grafted poly(vinylidene fluoride) (HBPE-g-PVDF) was synthesized and used as additive in preparation of PVDF blend membranes. HBPE-g-PVDF copolymer was characterized with FTIR and TGA techniques. The prepared membranes were also characterized with SEM, AFM and contact angle measurement. The performance of prepared membranes as nanofiltration membrane was studied by pure water flux (PWF), salt rejection, dynamic and static fouling tests. The results showed that hydrophilicity of prepared membranes greatly increased after blending, and their pore size and pore size distribution and so PWF of blend membranes increased.  相似文献   

5.
Poly(vinylidene fluoride) (PVDF) membranes were hydrophilic modified with hydroxyl group terminated hyperbranched poly(amine‐ester) (HPAE). Fourier transform infrared spectroscopy (FT‐IR) was used to study the chemical change of PVDF membranes. X‐ray photoelectron spectroscopy (XPS) indicated that some HPAE molecules were retained in PVDF membrane through polymer chain coiling. The presence of HPAE would improve the hydrophilicity of PVDF membrane. Scanning electron microscopy (SEM) was employed to characterize the morphology of different membranes. The thermodynamic stability for PVDF/DMAc/HPAE/Water system was characterized by the determination of the gelation values. Precipitation kinetics for PVDF/DMAc/HPAE/Water system was studied by precipitation time measurement. The water contact angle indicated that the hydrophilicity and the biocompatibility corresponding to protein adsorption of PVDF membrane were improved significantly after blending with hydrophilic HPAE molecules. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
Polyacrylonitrile (PAN) was blended with polyvinylidine fluoride (PVDF) at various ratios and made into membranes. The hemocompatibility of the resulting membranes was evaluated based on human plasma proteins adsorption, platelet adhesion, thrombus formation, and blood coagulation time. The PAN/PVDF blends exhibited partial miscibility according to the inward shifting of their two glass transition temperatures. The microstructures of blend membranes examined using atomic force microscopy (AFM) indicated that the roughness increased with the PVDF content, and the phase separation was too severe to form a membrane when the PVDF content was more than 30%. The water contact angle of PAN/PVDF blend membranes increased with the PVDF content. By blending with 20 wt% apolar PVDF the adsorption of blood proteins could be reduced, and hence the platelet adhesion and thrombus formation was also reduced. However, when the PVDF content was 30 wt%, severe thrombogenicity was observed due probably to the more porous structure of blend membrane. These results demonstrated that the hemocompatibility would be improved for PAN/PVDF blend membranes with appropriate hydrophilicity and roughness. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

7.
朱宝库 《高分子科学》2010,28(3):337-346
<正>High density polyethylene(HDPE)/polyethylene-block-poly(ethylene glycol)(PE-b-PEG) blend porous membranes were prepared via thermally induced phase separation(TIPS) process using diphenyl ether(DPE) as diluent.The phase diagrams of HDPE/PE-b-PEG/DPE systems were determined by optical microscopy and differential scanning calorimetry(DSC).By varying the content of PE-b-PEG,the effects of PE-b-PEG copolymer on morphology and crystalline structure of membranes were studied by scanning electron microscopy(SEM) and wide angle X-ray diffraction(WAXD). The chemical compositions of whole membranes and surface layers were characterized by elementary analysis,Fourier transform infrared spectroscopy-attenuated total reflection(FTIR-ATR) and X-ray photoelectron spectroscopy(XPS).Water contact angle,static protein adsorption and water flux experiments were used to evaluate the hydrophilicity,antifouling and water permeation properties of the membranes.It was found that the addition of PE-b-PEG increased the pore size of the obtained blend membranes.In the investigated range of PE-b-PEG content,the PEG blocks could not aggregate into obviously separated domains in membrane matrix.More importantly,PE-b-PEG could not only be retained stably in the membrane matrix during membrane formation,but also enrich at the membrane surface layer.Such stability and surface enrichment of PE-b-PEG endowed the blend membranes with improved hydrophilicity,protein absorption resistance and water permeation properties,which would be substantially beneficial to HDPE membranes for water treatment application.  相似文献   

8.
High density polyethylene (HDPE)/polyethylene-Wock-poly(ethylene glycol) (PE-b-PEG) blend porous membranes were prepared via thermally induced phase separation (TIPS) process using diphenyl ether (DPE) as diluent. The phase diagrams of HDPE/PE-b-PEG/DPE systems were determined by optical microscopy and differential scanning calorimetry (DSC). By varying the content of PE-b-PEG, the effects of PE-b-PEG copolymer on morphology and crystalline structure of membranes were studied by scanning electron microscopy (SEM) and wide angle X-ray diffraction (WAXD). The chemical compositions of whole membranes and surface layers were characterized by elementary analysis, Fourier transform infrared spectroscopy-attenuated total reflection (FTIR-ATR) and X-ray photoelectron spectroscopy (XPS). Water contact angle, static protein adsorption and water flux experiments were used to evaluate the hydrophilicity, antifouling and water permeation properties of the membranes. It was found that the addition of PE-b-PEG increased the pore size of the obtained blend membranes. In the investigated range of PE-b-PEG content, the PEG blocks could not aggregate into obviously separated domains in membrane matrix. More importantly, PE-b-PEG could not only be retained stably in the membrane matrix during membrane formation, but also enrich at the membrane surface layer. Such stability and surface enrichment of PE-b-PEG endowed the blend membranes with improved hydrophilicity, protein absorption resistance and water permeation properties, which would be substantially beneficial to HDPE membranes for water treatment application.  相似文献   

9.
A styrene-maleic anhydride (SMA) alternating copolymer with ultrahigh molecular weight (Mw > 106) synthesized in super critical carbon dioxide (SC CO2) medium was used as hydrophilic polymeric additive in the preparation of polyethersulfone (PES) membranes. The PES/SMA blend membranes were prepared by immersion precipitation process. X-ray photoelectronic spectroscopy (XPS) measurements confirmed that the hydrolyzed SMA preferentially segregated to membrane–coagulant interface during membrane formation. For the PES/SMA blend membranes, no big change was observed in the cross-sectional structure and the mechanical properties were well maintained after SMA addition except that a thicker top layer was formed. The surface morphology analysis by atomic force microscopy (AFM) showed that the membrane surface roughness increased with the added SMA amount. The results of water contact angle, water absorbance measurements and static protein adsorption experiments revealed that the surface enrichment of SMA endowed PES/SMA blend membranes with significantly improved surface hydrophilicity and protein-adsorption resistance.  相似文献   

10.
以聚醚链段为侧链的两亲性梳状聚醚硅氧烷(ACPS)为改性剂,研究了相转化法制备聚偏氟乙烯(PVDF)多孔膜的改性效果与机理.采用SEM、XPS、接触角、水通量等考察了ACPS对膜结构与性能的影响.研究发现,ACPS在相转化成膜过程中不流失,随着制膜液中ACPS含量的增加,相分离速度降低,膜中微孔由指状结构向蜂窝状结构发展,膜强度提高,亲水性显著提高.提出了ACPS在膜表面的富集现象和在膜中的稳定性机理和模型.结果表明,两亲性梳状聚醚硅氧烷在原理上是一类适合于相转化法制备聚合物微孔膜表面亲水化改性的有效物质.  相似文献   

11.
Amphiphilic comb-like polysiloxane (ACPS) containing polyether side chains was used as the modification reagent in the preparation of hydrophilic porous poly (vinylidene fluoride) (PVDF) membranes via a phase inversion process. The effects of ACPS on morphology, crystallinity, mechanical properties, reservation of ACPS in the phase inversion process, chemical structure, hydrophilicity and filterability performance of porous PVDF membranes were discussed. It was found that the addition of ACPS would result in the delayed demixing which yields “sponge-like” sublayers and longer crystallization time during the membrane formation process. It was revealed that O/F ratios of the bulk membrane were almost the same as those of the corresponding casting solutions which obviously indicated the high reservation of ACPS in the membrane formation process. The fact that the O/F ratios in the membrane surface layers were much higher than those in the bulk membrane proved the enrichment of ACPS on the surface. The filterability experiments and water contact angle testing proved the hydrophilicity of the blend membranes. Through a schematic model, the mechanism relating the membrane structure and performance was interpreted. From the observed results, it can be concluded that ACPS acts as a potential candidate material for preparing PVDF membranes with extraordinary hydrophilicity and filterability. __________ Translated from Acta Polymerica Sinica, 2007, 12: 1168–1175  相似文献   

12.
A silver nanoparticles-poly(carboxybetaine methacrylate)(AgNPs-PCBMA) nanocomposite was prepared on poly(vinylidene fluoride)(PVDF) membrane surface to improve its hydrophilicity and antifouling properties. Firstly, the PVDF membranes were grafted by PCBMA via physisorbed free radical grafting technique. Then Ag+ coordinated to the carbonyl group on PCBMA andsubsequently was reduced to silver nanoparticles. The hydrophilicity of the PVDF-gPCBMA/Ag membrane wasenhanced with the increasing fixed degree(FD) of AgNPs, and the original water contact angle of membrane was reduced to 33.97°. Additionally, water flux recovery ratio(FRR) andbovine serum albumin(BSA) rejection ratio of PVDF-g-PCBMA/AgNPs membrane wereimproved from 52% to 93.32% and 28.12% to 91.12%, respectively. Further, the PVDF-g-PCBMA/AgNPs membranes exhibited the more pronounced inhibition zone. The study demonstrated that compared with pure AgNPs or the PCBMA polymer brush, the synergistic effect of PCBMA and AgNPs made PVDF membranes havebetter hydrophilicity and anti-bacterialperformances.  相似文献   

13.
The hydrophilicity of poly(vinylidene fluoride) (PVDF) was first improved by in situ polymerization of polar monomer in PVDF solution. Methyl methacrylate was adopted as the reaction monomer, and the polymerization occurred in a solution of PVDF in N,N-dimethylformamide. PVDF/poly(methyl methacrylate) (PMMA) blend was obtained after in situ polymerization. The relative hydrophilicity of the in situ blend was characterized by contact angle measurement. At the same time, the hydrophilicity of the PVDF/PMMA blends prepared by solution blending was compared with that of the in situ blend. The contact angle measurements indicated that in situ polymerization has a stronger modifying effect on the hydrophilicity of PVDF than solution blending.  相似文献   

14.
PVDF/(PEI‐C/PAA)n functional membranes were prepared by layer‐by‐layer (LbL) assembly, and their heavy metal ions adsorption capability was investigated. The changes in the chemical compositions of membrane surfaces were determined by X‐ray photoelectron spectroscopy (XPS). XPS results show that the surface of the PVDF membrane can be alternatively functionalized by PEI‐C and PAA. The membrane surface hydrophilicity was evaluated through water contact angle measurement. Contact angle results show that the surface hydrophilicity of the membrane surface depends on the outermost deposited layer. Morphological changes of membrane surfaces were observed by scanning electron microscopy (SEM). The water fluxes for these membranes were elevated after modification. The performances of the PVDF/(PEI‐C/PAA)n membranes on the adsorption of copper ions (Cu2+) from aqueous solutions were investigated by inductively coupled plasma (ICP). The results indicate that the PVDF/(PEI‐C/PAA)n functional membranes show high copper ions adsorption ability. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
以氯甲基化双酚A型聚砜(PSF-CH2Cl)为大分子引发剂,通过原子转移自由基聚合(ATRP)法合成了以聚砜(PSF)为疏水主链、聚(聚乙二醇单甲醚甲基丙烯酸酯)[P(PEGMA)]为亲水侧链的梳状两亲性共聚物PSF-g-P(PEGMA).FT-IR和1H-NMR的表征结果证实了两亲性共聚物的生成.将PSF-g-P(PEGMA)与PSF进行共混,通过浸没沉淀法制备了共混超滤膜.研究发现,引入5 wt%的PSF-g-P(PEGMA),共混膜的孔隙率和平均孔径分别从65.9%和0.08μm提高到81.9%和0.18μm;将共混膜于90℃热水中浸泡24 h后,膜表面O/S从14.63提高到17.16;共混膜的亲水性和抗牛血清蛋白(BSA)吸附性能显著提升.  相似文献   

16.
Porous membranes were prepared via phase inversion process from casting solution composed of poly(vinylidene fluoride) (PVDF), N,N-dimethylacetamide (DMAc), and hyperbranched polyglycerol (HPG). The membranes were characterized in terms of surface and bulk chemical compositions, morphology, water contact angle, porosity, and water flux. The effects of HPG content on membrane structures and properties were investigated. The effect of HPG addition on the hydrophilicity was discussed as well when the compositions of coagulation bath were changed. To better understand the special effects of HPG on the structures and properties of the membranes, PVDF membranes prepared using HPG as the additive were compared with those prepared using polyethylene glycol (PEG) as the additive.  相似文献   

17.
The synthesis of a novel amphiphilic comb-shaped copolymer consisting of a main chain of styrene-(N-(4- hydroxyphenyl) maleimide)(SHMI) copolymer and poly(ethylene glycol) methyl ether methacrylate(PEGMA) side groups was achieved by atom transfer radical polymerization(ATRP).The amphiphilic copolymers were characterized by ~1H-NMR, Fourier transform infrared(FTIR) spectroscopy and gel permeation chromatography(GPC).From thermogravimetric analysis (TGA),the decomposition temperature of SHMI-g-PEGMA is low...  相似文献   

18.
In this work, the hemocompatibility of PEGylated poly(vinylidene fluoride) (PVDF) microporous membranes with varying grafting coverage and structures via plasma-induced surface PEGylation was studied. Network-like and brush-like PEGylated layers on PVDF membrane surfaces were achieved by low-pressure and atmospheric plasma treatment. The chemical composition, physical morphology, grafting structure, surface hydrophilicity, and hydration capability of prepared membranes were determined to illustrate the correlations between grafting qualities and hemocompatibility of PEGylated PVDF membranes in contact with human blood. Plasma protein adsorption onto different PEGylated PVDF membranes from single-protein solutions and the complex medium of 100% human plasma were measured by enzyme-linked immunosorbent assay (ELISA) with monoclonal antibodies. Hemocompatibility of the PEGylated membranes was evaluated by the antifouling property of platelet adhesion observed by scanning electron microscopy (SEM) and the anticoagulant activity of the blood coagulant determined by testing plasma-clotting time. The control of grafting structures of PEGylated layers highly regulates the PVDF membrane to resist the adsorption of plasma proteins, the adhesion of platelets, and the coagulation of human plasma. It was found that PVDF membranes grafted with brush-like PEGylated layers presented higher hydration capability with binding water molecules than with network-like PEGylated layers to improve the hemocompatible character of plasma protein and blood platelet resistance in human blood. This work suggests that the hemocompatible nature of grafted PEGylated polymers by controlling grafting structures gives them great potential in the molecular design of antithrombogenic membranes for use in human blood.  相似文献   

19.
Phospholipid polymer, poly[2-methacryloyloxyethyl phosphorylcholine (MPC)], was grafted with polyethylene (PE) membrane using photoinduced polymerization technique to make the membrane resistant to cell adhesion. The water contact angle on the PE membrane grafted with poly(MPC) decreased with an increase in the photopolymerization time. This decrease corresponded to the increase in the amount of poly(MPC) grafted on the PE surface. The same graft polymerization procedure was applied using other hydrophilic monomers, such as acrylamide (AAm), N-vinylpyrrolidone (VPy) and methacryloyl poly(ethylene glycol) (MPEG). These monomers were also polymerized to form grafted chains on the PE membrane, and the grafting was confirmed with X-ray photoelectron spectroscopy. Analysis of amount and distribution of plasma proteins at the plasma-contacting surface of the original and the modified PE membranes were analyzed using immunogold assay. The grafting of poly(MPC) and poly(VPy) on PE membrane reduced the plasma protein adsorption significantly compared with that on the original PE membrane. However, the PE membranes grafted with poly(AAm) or poly(MPEG) did not show any effects on protein adsorption. Platelet adhesion on the original and modified PE membranes from platelet-rich plasma was also examined. A large number of platelets adhered and activated on the original PE membrane. Grafting with poly(AAm) did not suppress platelet adhesion, but grafting with poly(MPC) or poly(VPy) on the PE membrane was effective in preventing platelet adhesion. It is concluded that the introduction of the phosphorylcholine group on the surface could decrease the cell adhesion to substrate polymer.  相似文献   

20.
A novel hydrophilic nanocomposite additive(TiO2-g-PNIPAAm) was synthesized by the surface modification of titanium dioxide(TiO2) with N-isopropylacrylamide(NIPAAm) via "graft-from" technique. And the nanocomposite membrane of poly(vinylidene fluoride)(PVDF)/TiO2-g-PNIPAAm was fabricated by wet phase inversion. The graft degree was obtained by thermo-gravimetric analysis(TGA). Fourier transform infrared attenuated reflection spectroscopy(FTIR-ATR) and X-ray photoelectronic spectroscopy(XPS) characterization results suggested that TiO2-g-PNIPAAm nanoparticles segregated on membrane surface during the phase separation process. Scanning electron microscopy(SEM) was conducted to investigate the surface and cross-section of the modified membranes. The water contact angle measurements confirmed that TiO2-g-PNIPAAm nanoparticles endowed PVDF membranes better hydrophlilicity and thermo-responsive properties compared with those of the pristine PVDF membrane. The water contact angle decreased from 92.8° of the PVDF membrane to 61.2° of the nanocompostie membrane. Bovine serum albumin(BSA) static and dynamic adsorption experiments suggested that excellent antifouling properties of membranes was acquired after adding TiO2-gPNIPAAm. The maximum BSA adsorption at 40 °C was about 3 times than that at 23 °C. The permeation experiments indicated the water flux recover ratio and BSA rejection ratio were improved at different temperatures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号