首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Poly(pyridine‐3‐boronic acid) (PPBA)/multiwalled carbon nanotubes (MWCNTs) composite modified glassy carbon electrode (GCE) was used for the simultaneous determination of ascorbic acid (AA), 3,4‐dihydroxyphenylacetic acid (DOPAC) and uric acid (UA). The anodic peaks for AA, DOPAC and UA at the PPBA/MWCNTs/GCE were well resolved in phosphate buffer solution (pH 7.4). The electrooxidation of AA, DOPAC and UA in the mixture solution was investigated. The peak currents increase with their concentrations increasing. The detection limits (S/N=3) of AA, DOPAC and UA are 5 µM, 3 µM and 0.6 µM, respectively.  相似文献   

2.
Gold (Au) huge particles were prepared by a pyrolysis process of AuCl3 dissolved in distilled water in the presence of multi‐walled carbon nanotubes (MWCNTs). X‐ray diffraction (XRD) and scanning electron microscopy (SEM) were used to characterize the obtained samples. The results showed that Au huge particles with a diameter close to 500 nm were fabricated. The electrocatalytic performance of the huge Au particles modified graphite electrode in the oxygen reduction reaction (ORR) was investigated using cyclic voltammetry (CV). It indicated that the pyrolysis time was a key factor that can affect the electrocatalysis of Au huge particles towards ORR. Developing a novel and simple method of pyrolysis for fabricating Au huge particles is the main contribution of this work, which will be very helpful in the preparation of Au huge particles on a large scale.  相似文献   

3.
This study investigates a new approach for the amperometric determination of sulfide using a hematoxylin multiwalled carbon nanotubes modified carbon paste electrode (HM‐MWCNTs/CPE). The experimental results show that HM‐MWCNTs/CPE significantly enhances the electrocatalytic activity towards sulfide oxidation. Cyclic voltammetric studies show that the peak potential of sulfide shifted from +400 mV at unmodified CPE to +175 mV at HM‐MWCNTs/CPE. The currents obtained from amperometric measurements at optimum conditions were linearly correlated with the concentration of sulfide. The calibration curve was obtained for sulfide concentrations in the range of 0.5–150×10?6 mol L?1. The detection limit was found to be 0.2×10?6 mol L?1 for the amperometric method. The proposed method was successfully applied to a river water sample in Pardubice, Czech Republic.  相似文献   

4.
通过油胺(Oleylamine)还原法制备了金纳米线(Au nanowires),将其与酸化处理的多壁碳纳米管(MWCNTs)通过层层组装制备了Au nanowires-MWCNTs复合结构修饰的玻碳电极(Au nanowires-MWCNTs/GCE).电化学研究结果表明,与单纯Au nanowires或MWCNTs修饰电极相比,Au nanowires-MWCNTs/GCE对葡萄糖表现出更优良的电催化性能.以Au nanowires-MWCNTs/GCE为阳极,电沉积Pt膜电极(Pt/GCE)为阴极,构建了葡萄糖/O2燃料电池.测试结果表明,构建的燃料电池的开路电位(OCP)为0.57 V,在0.44 V下最大功率密度(Pmax)为0.28 m W/cm2.  相似文献   

5.
利用荷叶萃取液生物合成纳米金,并与多壁碳纳米管/L-半胱氨酸复合成修饰电极材料,研究了左旋多巴在该修饰电极上的电化学行为.在0.2 mol/L乙酸-乙酸钠体系(pH=2.6)中,氧化峰电流与左旋多巴浓度在0.6~40μmol/L及60~120μmol/L范围内呈良好的线性关系,检出限达5.2×10-8mol/L.实验结果表明,生物合成纳米金复合多壁碳纳米管/L-半胱氨酸修饰电极具有良好的稳定性和高灵敏度,对实际样品测定的回收率在91.2%~102.5%之间.  相似文献   

6.
The electrooxidation of epinephrine (EPI) and piroxicam (PRX) has been investigated by application of nickel hydroxide nanoparticles/multiwalled carbon nanotubes composite electrode (MWCNTs‐NHNPs/GCE) using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) methods. The modified electrode showed suitable electrochemical responses for EPI and PRX determination. Under the optimum conditions the electrode provides a linear response versus EPI and PRX concentrations in the range of 1–220 µM and 0.7–75 µM, respectively using the DPV method. Linear responses versus EPI and PRX concentrations in the range of 1–1000 µM and 1–800 µM, respectively, were obtained using the CA method. The modified electrode was used for determination of EPI and PRX in human urine with satisfactory results.  相似文献   

7.
李云龙  苏招红  陈超  孟越  谢青季 《应用化学》2011,28(9):1046-1051
基于多巴胺(DA)在多壁碳纳米管(MWCNTs)修饰玻璃碳(GC)电极上的电聚合,制得聚多巴胺(PDA)/MWCNTs/GC电极,并对该修饰电极进行了电化学阻抗谱 (EIS)和循环伏安法(CV)表征。 在该修饰电极上,DA呈现良好的电化学行为。在pH=7.4磷酸缓冲溶液中其氧化电流显著高于在裸电极上的响应,且能有效地抑制2.0 mmol/L抗坏血酸(AA)或K4Fe(CN)6的直接电化学响应,表明MWCNTs可增敏信号,且阳离子选择透过性PDA膜可抑制阴离子的电化学干扰。 采用CV实验检测DA,DA氧化的半微分伏安峰高(ipa-sd)与多巴胺浓度在0.08~1.76 μmol/L范围内呈线性关系,在无抗坏血酸和有0.5 mmol/L抗坏血酸共存时的线性回归方程分别为ipa-sd(μA/s1/2)=0.107+0.405c(μmol/L)(r2=0.986)和ipa-sd(μA/s1/2)=0.628+0.649c(μmol/L)(r2=0.992),检测限均为8.0×10-8 mol/L(S/N=3)。 该法用于盐酸多巴胺注射液中多巴胺的快速测定,结果满意。  相似文献   

8.
In the present work, the electrochemical oxidation of nitrite on carbon ceramic electrode (CCE) modified with multi‐walled carbon nanotubes (MWCNTs) was investigated. The modified electrode exhibited catalytic activity toward the electrooxidation of nitrite. Experimental parameters such as solution pH, scan rate, concentration of nitrite and nanotubes amount were studied. It was shown nitrite can be determined by differential pulse voltammetry (DPV) and hydrodynamic amperometry (HA) using the modified electrode. Under the optimized conditions the calibration plots are linear in the concentration ranges of 15‐220 and 50‐3000 μM with limit of detections of 4.74 and 35.8 μM for DPV and HA, respectively. The modified electrode was successfully applied for analysis of nitrite in spinach sample. The results were favorbly compared to those obtained by UV‐Visible spectrophotometric method. The results of the analysis suggest that the proposed method has promise for the routine determination of nitrite in the examined products.  相似文献   

9.
A novel immunosensor has been developed by self‐assembling Au NPs onto a ferrocene‐branched chitosan/multiwalled carbon nanotubes (CS‐Fc/MWCNTs) modified electrode for the sensitive determination of hepatitis B surface antigen (HBsAg). The formation of CS‐Fc effectively avoids the leakage of Fc and retains its electrochemical activity. Incorporation of MWCNTs and Au NPs into CS‐Fc further increases the electrochemical active Fc in the CS films and provides interactive sites for the immobilization of HBsAb. The morphologies and electrochemistry of the formed biofilm were investigated by using scanning electron microscopy and electrochemical techniques. The immunosensor exhibits a specific response to HBsAg in the range of 1.0–420 ng mL?1. Excellent analytical performance, fabrication reproducibility and operational stability of the proposed immunosensor indicated its promising application in clinical diagnostics.  相似文献   

10.
A sensitive electrochemical method was developed for the determination of bisphenol A (BPA) at a glassy carbon electrode (GCE) modified with a multiwalled carbon nanotubes (MWCNTs)‐gold nanoparticles (GNPs) hybrid film, which was prepared based on the electrostatic interaction between positively charged cetyltrimethylammonium bromide (CTAB) and negatively charged MWCNTs and GNPs. The MWCNT‐GNPs/GCE exhibited an enhanced electroactivity for BPA oxidation versus unmodified GCE and MWCNTs/GCE. The experimental parameters, including the amounts of modified MWCNTs and GNPs, the pH of the supporting electrolyte, scan rate and accumulation time, were examined and optimized. Under the optimal conditions, the differential pulse voltammetric anodic peak current of BPA was linear with the BPA concentration from 2.0×10?8 to 2×10?5 mol L?1, with a limit of detection of 7.5 nmol L?1. The proposed procedure was applied to determine BPA leached from real plastic samples with satisfactory results.  相似文献   

11.
Being awfully harmful to the environment and human health, the qualitative and quantitative determinations of polycyclic aromatic amines (PAAs) are of great significance. In this paper, a novel core–shell heterostructure of multiwalled carbon nanotubes (MWCNTs) as the core and graphene oxide nanoribbons (GONRs) as the shell (MWCNTs@GONRs) was produced from longitudinal partially unzipping of MWCNTs side walls using a simple wet chemical strategy and applied for electrochemical determination of three kinds of PAAs (1-aminopyrene (1-AP), 1-aminonaphthalene and 3,3′-diaminobiphenyl). Scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, Raman spectroscopy, thermogravimetric analysis and electrochemical methods were used to characterize the as-prepared MWCNTs@GONRs. Due to the synergistic effects from MWCNTs and GONRs, the oxidation currents of PAAs at the MWCNTs@GONRs modified glassy carbon (GC) electrode are much higher than that at the MWCNTs/GC, graphene/GC and bare GC electrodes. 1-AP was used as the representative analyte to demonstrate the sensing performance of the MWCNTs@GONRs/GC electrode, and the proposed modified electrode has a linear response range of 8.0–500.0 nM with a detection limit of 1.5 nM towards 1-AP.  相似文献   

12.
通过电沉积的方式在多壁碳纳米管(MWCNTs)修饰玻碳电极表面上沉积铂(pt)纳米粒子,并运用循环伏安法(CV)、示差脉冲伏安法(DPV)探讨了芦丁在铂纳米/碳纳米管/玻碳电极上的电化学行为.实验结果表明,芦丁在该修饰电极上呈现一对良好氧化还原峰,其氧化峰电流与浓度在3.2×10(-8)~1.2×10(-5)mol/L...  相似文献   

13.
A glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNTs) and a hydrophobic ionic liquid (IL), was used for the simultaneous voltammetric determination of theophylline (TP) and guaifenesin (GF). The results showed that the oxidations of TP and GF were facilitated at modified electrode and peak‐to‐peak separation at MWCNT? IL/GCE (252 mV) was larger than that observed at unmodified GCE (165 mV). Voltammetric signals for TP and GF exhibited linear ranges of 0.5 to 98.0 µM (R2>0.99) and 1.5 to 480.0 µM (R2>0.99), respectively. The method was used to estimate TP and GF contents in some real samples.  相似文献   

14.
《Analytical letters》2012,45(15):2460-2473
Abstract

The direct electrochemistry of hemoglobin (Hb) was realized on chitosan and multiwalled carbon nanotubes (MWCNTs)–modified carbon ionic liquid electrode (CILE). The CILE was fabricated first and further modified by MWCNTs to get an electrode as MWCNTs/CILE. The Hb was immobilized on the surface of MWCNTs/CILE with the help of chitosan film. Ultraviolet–visible (UV-vis) and Fourier transform–infrared (FT-IR) spectra indicated that Hb kept its native structure in the modified film. A pair of well-defined quasi-reversible redox peaks of heme Fe(III)/Fe(II) couple appeared with the formal potential (E0′) as ?0.314 V (vs. SCE) in pH 7.0 phosphate buffer solution (PBS). The modified electrode showed good electrocatalytic ability for the reduction of trichloroacetic acid.  相似文献   

15.
In this study, we combine magnetic solid phase extraction (MSPE), with the screen-printed carbon electrode (SPCE) modified by a molecular imprinted polymer (MIP) for sensitive and selective extraction and electrochemical determination of Rhodamine B in food samples. A magnetic solid phase extraction (MSPE) was carried out using magnetic poly(styrene-co-divinylbenzene) (PS-DVB) and magnetic nanoparticles (MNPs) synthetized on the surface of multiwalled carbon nanotubes (MWCNTs). An MIP was prepared on the surface of MWCNTs in the presence of titanium oxide nanoparticles (TiO2NPs) modifying the SPCE for the rapid electrochemical detection of Rhodamine B. The MIPs synthesis was optimized by varying the activated titanium oxide (TiO2) and multiwalled carbon nanotubes (MWCNTs) amounts. The MSPE and electrochemical detection conditions were optimized as well. The present method exhibited good selectivity, high sensitivity, and good reproducibility towards the determination of Rhodamine B, making it a suitable method for the determination of Rhodamine B in food samples.  相似文献   

16.
This study reports the catalytic oxidation and detection of tea polyphenols (TPs) at glassy‐carbon electrode modified with multiwalled carbon nanotubes‐chitosan (MWCNTs‐CS) film. The adsorption of TPs at the surface of the MWCNTs through π–π conjugation prevents the aggregation of nanotubes and induces a stable MWCNTs suspension in water over 30 days. Based on the adsorptive accumulation of polyphenols at MWCNTs, TPs is sensitively and selectively detected by adsorptive stripping voltammetry. The accumulation conditions and pH effect on the adsorptive stripping detection were examined. The linear range was found to be 100 to 1000 mg L?1 with a detection limit of 10 mg L?1 (S/N=3) for 2.5 min accumulation. Additionally, the MWCNTs‐CS electrode is easily renewed by applying positive potential to remove the adsorbed TPs. This method was successfully applied to determine TPs in commercially available teas with satisfied result compared with that of conventional spectrometric analysis.  相似文献   

17.
姜炜  黄蕾  张玉忠 《分析化学》2011,39(7):1038-1042
构建了基于金纳米粒子/聚阿魏酸/多壁碳纳米管(AuNPs/PFA/MWCNTs)修饰电极的DNA计时库仑法生物传感器.利用循环伏安技术在多壁碳管修饰的玻碳电极表面上聚合一层阿魏酸,在恒电位条件下,在阿魏酸表面沉积金纳米粒子,巯基DNA作为探针通过金硫键固定在金纳米粒子表面.电化学交流阻抗技术(EIS)与扫描电镜(SEM...  相似文献   

18.
Narang J  Chauhan N  Pundir CS 《The Analyst》2011,136(21):4460-4466
We describe the construction of a polyaniline (PANI), multiwalled carbon nanotubes (MWCNTs) and gold nanoparticles (AuNPs) modified Au electrode for determination of hydrogen peroxide without using peroxidase (HRP). The AuNPs/MWCNT/PANI composite film deposited on Au electrode was characterized by Scanning Electron Microscopy (SEM) and electrochemical methods. Cyclic voltammetric (CV) studies of the electrode at different stages of construction demonstrated that the modified electrode had enhanced electrochemical oxidation of H(2)O(2), which offers a number of attractive features to develop amperometric sensors based on split of H(2)O(2). The amperometric response to H(2)O(2) showed a linear relationship in the range from 3.0 μM to 600.0 μM with a detection limit of 0.3 μM (S/N = 3) and with high sensitivity of 3.3 mA μM(-1). The sensor gave accurate and satisfactory results, when employed for determination of H(2)O(2) in milk and urine.  相似文献   

19.
A glassy carbon electrode (GCE) was modified with a thin layer of multiwalled carbon nanotubes (MWCNTs) and subsequently, electrochemically deposited poly‐pyrrole. The electrochemical behavior of mesalazine was studied on the surface of the modified electrode by applying linear sweep voltammetry (LSV). The electropolymerization process and the electrochemical response toward mesalazine were investigated in the presence of different aromatic anion dopants including, benzenesulfonic acid (BSA), 1,3‐benzenedisulfonic acid (1,3‐BDSA), 1,5‐naphthalenedisulfonic acid (1,5‐NDSA) and new coccine (NC). By using 1,5‐NDSA as dopant, a significant increase (~418 times) in the peak current of mesalazine was observed, in comparison to the bare GCE. Experimental variables such as drop size of the cast MWCNTs suspension, pH of the supporting electrolyte, accumulation conditions and the number of scans in the electropolymerization process were optimized by monitoring the LSV responses of mesalazine. Under the optimum conditions, two linear dynamic ranges of 0.01–0.1 µmol L?1 and 0.1–1.0 µmol L?1 with a detection limit of 3 nmol L?1 were resulted for the voltammetric determination of mesalazine. The prepared electrode showed high sensitivity, stability and good reproducibility for determination of mesalazine. These properties made the prepared sensor suitable for the determination of mesalazine in pharmaceutical and clinical preparations.  相似文献   

20.
《Analytical letters》2012,45(17):3159-3169
Abstract

The nanocomposites of gold nanoparticles and multi‐walled carbon nanotubes (MWCNTs) have been applied in the enhanced electrochemical detection of DNA hybridization. Gold nanoparticles coated on MWCNTs uniformly were synthesized by simply one step reaction. Target DNA was detected by the peak current difference of differential pulse voltammetry (DPV) signals of the electroactive indicator methylene blue (MB) before and after hybridization on the Au/MWCNTs modified glass carbon electrode (GCE). Due to the excellent electrical conductivity of the novel matrix, the biosensor revealed high sensitivity with the detection level down to 1.0 pM. Excellently selectivity and reproducibility were also discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号