首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
本文建立了超声波辅助萃取/固相萃取法-气质联用法(UAE/SPE-GS/MS)同时测定纺织固废物中17种氯苯类污染物的分析方法。从超声萃取溶剂、超声萃取时间、超声萃取温度和固相萃取小柱等前处理条件进行优化,以保留时间定性,外标法定量。结果表明,纺织固废样品在超声50℃的水浴中经二氯甲烷溶剂超声萃取30min后,再通过弗罗里硅土(Florisil)固相萃取柱净化,测得17种氯苯类污染物的回收率为80%~107.6%,相对偏差RSD(n=10)小于5.5%。  相似文献   

2.
郭坚  杨新磊  叶明立 《分析化学》2011,39(8):1256-1260
建立了全自动化在线固相萃取-高效液相色谱法快速、准确测定水体中3种痕量微囊藻毒素的新方法.样品用自动进样器连续注入固相萃取小柱完成富集后,通过双梯度高效液相系统中的一个泵(上样泵)实现净化,再通过阀切换将固相萃取小柱切换至分析流路中,用另一个泵(分析泵)将待测物冲洗至分析柱进行测定.方法使用Acclaim PA柱芯(1...  相似文献   

3.
建立了固相萃取-气相色谱/质谱(SPE-GC/MS)法同时测定化妆品中14种邻苯二甲酸酯类和5种己二酸酯类成分。样品经正己烷超声提取、中性氧化铝柱(AL-N)固相萃取纯化后,采用GC/MS(SIM)内标法进行定性定量分析。19种目标物在1~40μg/mL(BXA为5~200μg/mL)的范围内呈现良好的线性关系,相关系数0.9973~1.0000,检出限为0.07~1.68mg/kg,加标回收率为89.1%~106.7%,相对标准偏差为0.75%~5.93%(n=6)。该方法干扰小,重现性好,结果准确,适用于化妆品中邻苯二甲酸酯类和己二酸酯类成分的分析测定。  相似文献   

4.
提出了顶空-固相微萃取-气相色谱-质谱法测定烟气中挥发性和半挥发性成分。结合信息量最大的原则,确定了固相微萃取时萃取纤维头为碳分子筛/聚二甲基硅烷萃取纤维头,萃取温度为70℃,萃取时间为60min。在气相色谱分离中用Agilent DB-1色谱柱为固定相,在质谱分析中采用全扫描模式。结果表明:共鉴定出107种成分,含量最大的成分是烟碱(18.07%),其次是新植二烯(11.46%),主要的3类挥发性和半挥发性成分依次为苯系物、酮类以及杂环类。  相似文献   

5.
徐磊  夏宁 《分析测试学报》2011,30(5):558-561
建立了一种在线固相萃取/高效液相色谱测定水样中4种痕量邻苯二甲酸酯(邻苯二甲酸甲酯、邻苯二甲酸乙酯、邻苯二甲酸丁酯和邻苯二甲酸(2-乙基)己酯)的新方法.样品由外加泵注入一根固相萃取小柱上进行富集,再将富集柱切换至高效液相色谱系统中,将富集在固相萃取小柱的邻苯二甲酸酯洗脱至分析柱进行分析.在线固相萃取柱为IonPac(...  相似文献   

6.
移取10.0mL环境水体样品,加入0.90g聚乙二醇-2000,超声溶解后,加入3.25g硫酸铵,超声萃取10min,离心后移取上层萃取相50μL,用流动相稀释至200μL,经0.22μm有机滤膜过滤,采用超高效液相色谱-串联质谱法测定滤液中5种三嗪类除草剂的残留量。以Zorbax Eclipse XDB-C_(18)色谱柱为固定相,以乙腈(7+3)溶液为流动相,串联质谱分析中采用电喷雾正离子源和选择离子监测模式。5种三嗪类除草剂的质量浓度均在0.100~10.00μg·L~(-1)内与其对应的峰面积呈线性关系,检出限(3S/N)为3.72~24.3ng·L~(-1)。方法用于环境水体样品的分析,加标回收率为80.8%~115%,测定值的相对标准偏差(n=5)为0.17%~6.4%。  相似文献   

7.
建立了固相萃取(SPE)净化,超高效液相色谱(UPLC)同时测定纺织品中14种二苯甲酮类(BPs)和苯并三唑类(BZTs)紫外吸收剂的分析方法。样品以甲醇-四氢呋喃超声提取,提取液经ENVI-Carb固相萃取柱净化后,在C18色谱柱和乙腈-0.1%甲酸水流动相下梯度洗脱分离,二极管阵列检测器测定。结果表明,14种紫外吸收剂在0.1~50 mg/L浓度范围内线性关系良好,相关系数均大于0.999;方法检出限为1~5mg/kg;阴性涤纶和腈纶样品在3个加标水平下的平均回收率(n=6)为81.5%~99.1%,相对标准偏差(RSD)为2.8%~7.5%。该方法简单快速,回收率和精密度良好,适用于纺织品中14种紫外吸收剂的同时测定。  相似文献   

8.
建立了复合分子印迹固相萃取(CMISPE)-高效液相色谱-三重四级杆串联质谱(HPLC-MS/MS)同时检测多种植物源性食品中20种三嗪类和磺酰脲类除草剂残留的分析方法。样品经乙腈提取后,利用液液萃取及复合分子印迹固相萃取小柱净化。液相色谱以乙腈和1%甲酸溶液作为流动相梯度洗脱,C8色谱柱分离,在多反应监测(MRM)正离子电喷雾扫描模式下进行HPLC-MS/MS分析。结果表明:20种除草剂在0.5~20 ng/m L范围内线性关系良好,相关系数均在0.99以上。对玉米样品进行3个水平的加标回收试验(5,10,20μg/kg),20种目标化合物的回收率在62.7%~117.4%之间,相对标准偏差(n=6)为1.7%~13.9%。检出限(S/N≥3)均小于0.63μg/kg,定量限(S/N≥10)均小于2.1μg/kg。方法适用于植物源性食品中20种三嗪类及磺酰脲类农药残留的检测。  相似文献   

9.
建立了分散固相萃取/高效液相色谱-串联质谱法(d SPE/LC-MS/MS)同时测定饲料中17种β-受体激动剂、18种β-内酰胺类、6种抗球虫类、5种大环内酯类、2种林可胺类、15种喹诺酮类、21种磺胺类及3种磺胺类增效剂等8类共计87种兽药的新方法。均质样品经0.1 mol/L Na2EDTA溶液分散后,以甲醇-乙腈(50∶50)超声提取,提取液用Bondesil-PSA吸附剂以分散固相萃取方式快速净化。待测物采用Poroshell EC-C18(100 mm×2.1 mm,2.4μm)色谱柱分离,在电喷雾离子源的正离子模式下以动态多反应监测(dynamic MRM)方式采集数据并作定性筛查和定量分析。87种药物在相应的浓度范围内线性良好,相关系数均大于0.99,在3个不同浓度加标水平下,平均回收率为63.7%~108.8%,相对标准偏差(RSD)为3.5%~15.2%,检出限(LOD,S/N≥3)和定量下限(LOQ,S/N≥10)分别为3~15μg/kg及10~50μg/kg。该方法灵敏、可靠,样品预处理简便、快速、价廉,适用于饲料中上述87种兽药的同时快速定性筛查和定量测定。  相似文献   

10.
本文采用甲基丙烯酸2-羟乙酯(HEMA)与乙二醇二甲基丙烯酸酯在移液器枪头中共聚制备固相微萃取整体柱,用于直接处理尿液中3种苯二氮卓类药物(BZDs)。实验考察了单体用量、聚合时间及固相微萃取条件对BZDs萃取效率的影响,评价了其吸附性能。当HEMA用量为40 mg,聚合温度60℃时,固相微萃取整体柱对目标物吸附效率达98.9%~100%,且对尿液中杂质的吸附率低于10%。取3 mL尿液样品,无需处理,直接上样至该柱,经4 mL纯净水冲洗,1 mL乙腈洗脱,得到的样品结合高效液相色谱仪分析。方法对3种BZDs在2.5~1 000 ng/mL浓度范围呈现良好线性关系(r=0.999),检出限(S/N=3)和定量限(S/N=10)为0.8~1.5 ng/mL和2.5~5.0 ng/mL,回收率为86.2%~107%。本方法构筑的萃取柱制备简单,能实现对原始尿液的直接、高效萃取,操作便捷。  相似文献   

11.
研究并优化了同时分析畜禽粪便中14种抗生素(四环素、磺胺、氟喹诺酮和大环内酯类)的加速溶剂萃取参数、固相富集净化程序、以及高效液相色谱分离和检测条件。结果表明,以1%乙酸(pH 2.6)作为流动相,在270 nm的检测波长下,14种抗生素能达到基线分离。3倍信噪比下,四环素、磺胺、氟喹诺酮和大环内酯类抗生素的检出限分别为35~90μg/kg,12~28μg/kg,9~17μg/kg及19μg/kg。加标浓度在1和10μg/g时,畜禽粪便样品经过50%甲醇的柠檬酸盐缓冲溶液提取,HLB固相萃取柱富集净化后,四环素、磺胺、氟喹诺酮和大环内酯类抗生素的回收率分别达到了58%~75%和66%~83%,74%~93%和91%~101%,74%~80%和80%~88%,85%和68%,相对标准偏差分别为6.2%~10.7%和7.8%~13.6,2.6%~10.2%和4.4%~13.2%,6.1%~12.5%和8.3%~14.6%,10.6%和12.3%。采用此方法对辽宁省部分规模化养殖场的猪粪、牛粪和鸡粪样品进行了检测。4类抗生素都有检出,浓度范围分别为0.75~22.34 mg/kg,0.10~1.71 mg/kg,0.38~4.46 mg/kg和0.23~0.35 mg/kg。  相似文献   

12.
应用固相萃取及高效液相色谱-串联质谱技术,建立了医院废水中12种磺胺、4种喹诺酮、3种四环素以及罗红霉素和甲氧苄氨嘧啶等21种抗生素的定性定量方法。水样经HLB小柱萃取富集,使用10%甲醇溶液净化,经甲醇洗脱定容后,以高效液相色谱-串联质谱多反应监测离子模式(MRM)对目标物进行分析。在优化实验条件下,21种抗生素的线性范围为1.0~500μg/L,相关系数r2>0.99,方法检出限为0.005~0.022μg/L。在加标量为0.05μg/L和1.0μg/L时,空白加标回收率分别为71%~105%和76%~111%,RSD均小于15%。以医院废水为基质,21种抗生素的加标回收率为71%~135%,RSD小于25%。该方法简捷、快速、准确,能够实现医院废水中多种抗生素药物残留的同时分析。  相似文献   

13.
在现有方法基础上对沉积物中磺胺类、喹诺酮类、大环内脂类和四环素类抗生素的提取、富集、净化以及仪器分析方法进行了优化。以EDTA-Mcllvaine缓冲溶液与乙腈(V:V,1:1)混合液作为提取液,利用超声波细胞破碎仪进行超声提取,串联强阴离子交换柱(SAX)和HLB固相萃取柱进行固相萃取(SPE),通过超高效液相/串联质谱(UPLC-MS/MS)测定沉积物中抗生素的含量。抗生素基质加标回收率在56.4%~110%,相对标准偏差为1.1%~24.3%,方法检出限0.0055~0.716 ng/g。本方法有效地提高了沉积物中抗生素的提取效率,并应用于实际样品的测定中。  相似文献   

14.
The present study was carried out to determine 16 antibiotics belonging to seven different groups (tetracyclines, sulfonamides, penicillins, fluoroquinolones, macrolides, lincosamides and trimethoprims) in duck meat. A solid‐phase extraction method based on Oasis HLB cartridges coupled with liquid chromatography–electrospray ionization tandem mass spectrometry was developed. Solutions of 0.1 m ethylenediaminetetraacetic acid disodium salt and 2% trifluoroacetic acid were used for the preliminary extraction of the target antibiotics from duck meat and n‐hexane was used for purification prior to solid‐phase extraction. Mobile phases composed of 0.1% trifluoroacetic acid in distilled water (solvent A) and 0.1% trifluoroacetic acid in methanol (solvent B), combined with a reversed‐phase C18 analytical column, provided the optimal separation and signal intensity. The linearity of the method was assessed using six concentrations (5, 10, 20, 30, 40, and 50 μg/kg), and the recoveries, which were calculated at three spiking concentrations (5, 10 and 20 μg/kg), were in the range 69.8–103.3% with relative standard deviations (RSDs) ≤ 6.9% for the 16 tested antibiotics. Matrix effects ranging from ?47.2 to ?13.5% were observed for all the analytes, and the limits of quantitation (LOQ), which ranged from 4.93 to 26.21 μg/kg, were much lower than the maximum residue limits (MRLs) set by various regulatory authorities. Ten samples from a market were tested, and none of the target analytes were detected. Thus, a simple and versatile protocol has been developed to detect and quantify 16 antibiotics in duck meat samples.  相似文献   

15.
An analytical method was developed to quantitatively determine pharmaceuticals in biosolid (treated sewage sludge) from wastewater treatment plants (WWTPs). The collected biosolid samples were initially freeze dried, and grounded to obtain relatively homogenized powders. Pharmaceuticals were extracted using accelerated solvent extraction (ASE) under the optimized conditions. The optimal operation parameters, including extraction solvent, temperature, pressure, extraction time and cycles, were identified to be acetonitrile/water mixture (v/v 7:3) as extraction solvent with 3 extraction cycles (15 min for each cycle) at 100 °C and 100 bars. The extracts were cleaned up using solid-phase extraction followed by determination by liquid chromatography coupled with tandem mass spectrometry. For the 15 target pharmaceuticals commonly found in the environment, the overall method recoveries ranged from 49% to 68% for tetracyclines, 64% to 95% for sulfonamides, and 77% to 88% for other pharmaceuticals (i.e. acetaminophen, caffeine, carbamazepine, erythromycin, lincomycin and tylosin). The developed method was successfully validated and applied to the biosolid samples collected from WWTPs located in six cities in Michigan. Among the 15 target pharmaceuticals, 14 pharmaceuticals were detected in the collected biosolid samples. The average concentrations ranged from 2.6 μg/kg for lincomycin to 743.6 μg/kg for oxytetracycline. These results indicated that pharmaceuticals could survive wastewater treatment processes, and accumulate in sewage sludge and biosolids. Subsequent land application of the contaminated biosolids could lead to the dissemination of pharmaceuticals in soil and water environment, which poses potential threats to at-risk populations in the receiving ecosystems.  相似文献   

16.
刘培勇  张惠  米之金  张良成  张光仁 《色谱》2019,37(10):1098-1104
建立了猪肉中11种常见的磺胺类兽药残留的两步液液萃取-固相萃取净化-高效液相色谱-串联质谱(LC-MS/MS)检测方法。猪肉样品经乙酸乙酯(含2%(v/v)甲酸)及丙酮分两步液液萃取,正己烷脱脂,Oasis MCX混合阳离子固相萃取小柱净化,氮吹浓缩,定容,过滤膜后进行高效液相色谱-串联质谱分析。采用多反应监测正离子模式进行检测,以基质校准曲线外标法定量。结果表明,在20~400 μg/L范围内11种磺胺类药物均呈现良好的线性关系(相关系数(r2)≥ 0.99),检出限(LODs)(S/N=3)和定量限(LOQs)(S/N=10)分别为0.1~1.0 μg/kg和0.2~3.0 μg/kg。对阴性猪肉样品,在50、100、200 μg/kg 3个水平下分别进行加标回收试验,测得各待测物的平均回收率为79.3%~105.5%之间,相对标准偏差为1.3%~11.6%(n=6)。该方法比采用一步液液萃取法具有更高的提取效率,同时结合固相萃取净化方法进一步富集目标化合物,降低了基质干扰,提高了检测灵敏度。  相似文献   

17.
建立固相萃取–高效液相色谱同时测定蔬菜中8种磺胺类抗生素(SAs)的分析方法。蔬菜样品经10 m L乙腈(添加2 g Na_2SO_4+0.1 g CH_3COONa+0.1 g Na_2EDTA)超声提取,提取液用正己烷液–液萃取去脂,经C18–OH固相萃取小柱净化后用高效液相色谱法紫外检测器测定。检测波长为270 nm,柱温为25℃,以乙腈–0.01 mol/L磷酸水溶液为流动相,采用梯度洗脱程序,8种SAs可以较好分离,质量浓度在0.10~100.00 mg/L范围内与色谱峰面积均成良好的线性关系,相关系数为0.999 7~0.999 9,方法检出限为25~75μg/kg,定量限为54~140μg/kg。8种SAs的加标平均回收率为68.70%~122.7%,测定结果的相对标准偏差为1.8%~4.5%(n=5)。该法具有灵敏度高、样品处理简单等优点,可用于蔬菜中磺胺类抗生素的检测。  相似文献   

18.
建立了一种高效、低成本的固相萃取-高效液相色谱(SPE-HPLC)同时测定鸡粪中6种常见抗生素(2种四环素类、2种喹诺酮类和2种磺胺类)的分析方法。样品经EDTA-McIlvaine缓冲液和有机混合提取液(甲醇-乙腈-丙酮,2:2:1,v/v/v)提取,过HLB固相萃取柱净化,甲醇-二氯甲烷(7:3,v/v)洗脱,高效液相色谱-二极管阵列检测器测定,检测波长λ=270 nm,柱温32℃,流动相为乙腈-0.7%(v/v)磷酸水溶液。该方法在0.5~100 mg/L质量浓度范围内的标准曲线相关系数r2在0.9999~1之间,样品加标回收率在70.0%~116.3%之间,相对标准偏差为1.2%~16.6%。方法检出限为1.3~6.7 μg/kg,定量限为3.5~9.2 μg/kg。应用该方法对辽宁省抚顺市某养鸡场当天的鸡粪进行检测,诺氟沙星和恩诺沙星(喹诺酮类)含量为未检出~9.23 mg/kg和1.57~7.69 mg/kg,磺胺二甲嘧啶(磺胺类)含量为2.02~13.05 mg/kg,磺胺甲恶唑、土霉素和四环素未测出。  相似文献   

19.
胡钰  朱青青  胡立刚  廖春阳 《色谱》2021,39(8):878-888
土壤基质复杂,土壤中残留的抗生素种类繁多,浓度多为痕量水平,高灵敏度的仪器方法、有效的净化和富集方法、多种类抗生素的同时检测是土壤中抗生素检测的重点和难点。该研究建立了固相萃取-超高效液相色谱-串联质谱法同时测定土壤中7类(磺胺类、氟喹诺酮类、四环素类、大环内酯类、β-内酰胺类、酰胺醇类和林可酰胺类)30种抗生素的方法。首先,通过参数优化确定最佳质谱条件,选择BEH-C18色谱柱,以0.1%(v/v)甲酸甲醇溶液-0.1%(v/v)甲酸水溶液为流动相,10%(v/v)甲醇水溶液为进样溶剂。然后,通过提取条件(萃取剂种类及体积)和固相萃取条件(上样液pH、淋洗液有机溶剂比例、洗脱液种类及体积)的优化,确定使用10 mL乙腈和Na2EDTA-McIlvaine缓冲液的混合溶液(1∶1, v/v)为萃取剂,萃取液pH调节至8.0后,采用HLB小柱进行固相萃取,并以10 mL超纯水淋洗净化,最后用10 mL甲醇-乙腈(1∶1, v/v)洗脱目标分析物。在优化的分析条件下,该方法的定量限为0.043~4.04 μg/kg,目标化合物的标准曲线线性关系良好,相关系数在0.992~1.00的范围内,在20、100、200 μg/kg的添加浓度下,大多数目标化合物的加标回收率范围为44.8%~164%,相对标准偏差为0.700%~14.8%。将该方法用于6个实际土壤样品的分析,结果显示在30种抗生素中,17种抗生素有检出,其中12种抗生素的检出率为100%。环丙沙星和诺氟沙星是土壤样品中含量最高的两种抗生素,它们的含量范围分别是13.7~32.1和15.6~43.6 μg/kg。本研究建立的方法简单、快速、溶剂使用量少,能用于土壤样品中痕量水平的7类30种抗生素的同时测定。  相似文献   

20.
建立了固相萃取-反相高效液相色谱法测定畜牧粪便中5种磺胺类、4种四环素类、2种喹诺酮类以及氯霉素和呋喃唑酮的检测方法.采用乙腈和0.01 mol/L草酸作为流动相分离4种四环素类和氯霉素,乙腈和0.025 mol/L醋酸铵作为流动相分离5种磺胺类和其它3种抗生素.结果表明,检测的13种抗生素出峰时间稳定,峰形较好,检出限0.01~0.05 mg/L,定量下限0.03~0.167 mg/L,采用柠檬酸缓冲液酸化的乙腈对猪粪便样品前处理,采用EDTA-McIlvaine提取液对鸡粪便样品前处理,两类样品均通过HLB固相萃取小柱纯化富集,回收率为54%~103%.该方法成功用于天津市4个畜牧养殖基地的20个畜牧粪便样品中抗生素的检测.结果表明,均有不同浓度的抗生素检出,浓度范围0.3~173 mg/kg.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号