首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
An ultrathin composite membrane has been developed as the outer covering barrier in a model amperometric glucose oxidase enzyme electrode. The membrane was formed by cathodic electropolymerization of divinylbenzene/ethylvinylbenzene at the surface of a gold coated polyester support membrane. Permeability coefficients were determined for O2 and glucose across membranes with a range of polymer thicknesses. Anionic interferents (such as ascorbate), were screened from the working electrode via a charge exclusion mechanism. The enzyme electrode showed an initial 10% signal drift when first exposed to whole human blood over a period of 2 hours, after which responses remained essentially stable. Whole blood patient glucose determinations yielded a correlation coefficient of r2=0.99 compared to standard hospital analyses.  相似文献   

2.
An ultrathin composite membrane has been developed as the outer covering barrier in a model amperometric lactate oxidase enzyme electrode. The membrane was formed by cathodic electropolymerization of divinylbenzene/ethylvinylbenzene at the surface of a gold coated polyester support membrane. Permeability coefficients were determined for O2 and lactate across membranes with a range of polymer thicknesses. Anionic interferents (such as ascorbate) were screened from the working electrode by the composite membrane. The composite enzyme electrode showed an increased working concentration range and extended linearity of responses in comparison to an uncoated enzyme electrode.  相似文献   

3.
An enzyme electrodes is described for glucose determination in unstirred, undiluted whole blood. The system comprises an H2O2-detecting electrode upon which is placed a membrane laminate incorporating glucose oxidase. The external membrane was pretreated with methyltrichlorosilane. The electrode response was linearly dependent on glucose concentration up to 50 mmol l?1 glucose, it had a decreased dependence on dissolved oxygen concentrations and gave response times of 30–90 s. Whole blood glucose measurements correlated well with a routine spectrophotometric method.  相似文献   

4.
《Electroanalysis》2005,17(19):1780-1788
The amperometric biosensing of aromatic amines using a composite glucose oxidase (GOD)‐peroxidase (HRP) biosensor in reversed micelles is reported. Rigid composite pellets of graphite and Teflon, in which GOD and HRP were coimmobilized by simple physical inclusion, were employed for the biosensor design. This design allows the in situ generation of the H2O2 needed for the enzyme reaction with the aromatic amines, thus preventing the negative effect that the presence of a high H2O2 concentration in solution has on HRP activity. The H2O2 in situ generation is performed by oxidation of glucose catalyzed by GOD. The effect of the composition of the reversed micelles, i.e., the nature of the organic solvent used as the continuous phase, the nature and concentration of the surfactant used as emulsifying agent, the aqueous 0.05 mol L?1 phosphate buffer percentage used as the dispersed phase, and the glucose concentration in the aqueous phase, on the biosensor response was evaluated. Reversed micelles formed with ethyl acetate, a 5% of phosphate buffer (pH 7.0) containing 3.0×10?3 mol L?1 glucose, and 0.1 mol L?1 AOT (sodium dioctylsulfosuccinate), were selected as working medium. Well‐defined and reproducible amperometric signals at 0.00 V were obtained for p‐phenylenediamine, 2‐aminophenol, o‐phenylenediamine, m‐phenylenediamine, 1‐naphthylamine, o‐toluidine and aniline. The useful lifetime of one single biosensor was of 60 days. The trend in sensitivity observed for the aromatic amines is discussed considering the effect of their structure on the stabilization of the radicals formed in the enzyme reaction which are electrochemically reduced. The behavior of the composite bienzyme electrode was also evaluated in a FI (flow injection) system using reversed micelles as the carrier. The suitability of the composite bienzyme electrode for the analysis of real samples was demonstrated by determining aniline in spiked carrots.  相似文献   

5.
Fei J  Wu K  Wang F  Hu S 《Talanta》2005,65(4):918-924
This paper describes glucose nanosensors based on the co-electrodeposition of a poly(vinylimidazole) complex of [Os(bpy)2Cl]+/2+ and glucose oxidase (GOD) on a low-noise carbon fiber nanoelectrodes (CFNE). The SEM image shows that the osmium redox polymer/enzyme composite film is uniform. The film modified CFNE exhibits the classical features of a kinetically fast redox couple bound to the electrode surface. A strong and stable electrocatalytic current is observed in the presence of glucose. Under the optimal experimental conditions, the nanosensor offers a highly sensitive and rapid response to glucose at an operating potential of 0.22 V. A wide linear dynamic rang of 0.01-15 mM range was achieved with a detection limit of 0.004 mM. Compared with the conventional gold electrode, the nanosensor possessed higher sensitivity and longer stability. Successful attempts were made in real time monitoring rabbit blood glucose levels.  相似文献   

6.
A simple procedure was developed to prepare a glassy carbon electrode modified with multi walled carbon nanotubes (MWCNTs) and Celestin blue. Cyclic voltammograms of the modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range (2–12). The formal potential of redox couple (E′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of Celestine blue immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2. The charge transfer coefficient (α) and heterogeneous electron transfer rate constants (ks) for GC/MWCNTs/Celestine blue were 0.43 and 1.26 s?1, respectively. The modified electrode show strong catalytic effect for reduction of hydrogen peroxide and oxygen at reduced overpotential. The glucose biosensor was fabricated by covering a thin film of sol‐gel composite containing glucose oxides (GOx) on the surface of Celestine blue /MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 0.3 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. The accuracy of the biosensor for glucose detection was evaluated by detection of glucose in a serum sample, using standard addition protocol. In addition biosensor can reach 90% of steady currents in about 3.0 sec and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) was eliminated. Furthermore, the apparent Michaelis–Menten constant 2.4 mM, of GOx on the nano composite exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of glucose biosensor.  相似文献   

7.
Polyvinyl formal (PVFM)‐based dense polymer membranes with nano‐Al2O3 doping are prepared via phase inversion method. The membranes and also their performances as gel polymer electrolytes (GPEs) for lithium ion battery are studied by field emission scanning electron microscope, X‐ray diffraction, differential scanning calorimetry, mechanical strength test, electrolyte uptake test, electrochemical impedance spectroscopy, cyclic voltammetry, and charge–discharge test. The polymer membrane with 3 wt % nano‐Al2O3 doping shows the improved mechanical strength of 12.16 MPa and electrolyte uptake of 431.25% compared with 10.47 MPa and 310.59% of the undoped sample, respectively. The membrane absorbs and swells liquid electrolyte to form stable GPE with ionic conductivity of 4.92 × 10?4 S cm?1 at room temperature, which is higher than 1.77 × 10?4 S cm?1 of GPE from the undoped membrane. Moreover, the Al2O3‐modified membrane supporting GPE exhibits wide electrochemical stability window of 1.2–4.8 V (vs. Li/Li+) and good compatibility with LiFePO4 electrode, which implies Al2O3‐modified PVFM‐based GPE to be a promising candidate for lithium ion batteries. © 2014 Wiley Periodicals, Inc. J. Polym. Sci. Part B: Polym. Phys. 2014 , 52, 572–577  相似文献   

8.
Porous composite membranes of regenerated silk fibroin and poly(vinyl alcohol) were prepared by adding polyethyleneglycol to the composite solution to reduce the mass-transfer resistance to the diffusion of substrate material transport; their surfaces were visualized with scanning electron microscopy. An amperometric glucose biosensor employing Meldola blue dispersed in polyester ionomer as electron transfer mediator was prepared to test the feasibility and workability of the composite membrane as immobilization matrix for glucose oxidase. The cationic exchange property of the polyester ionomer was employed to provide high local concentrations of Meldola blue (MB+) in the polymer film via ion exchange. Performance and characteristics of the glucose biosensor were evaluated with respect to response time, detection limit, applied potential, thickness of polyester ionomer membrane, pH and temperature. The glucose biosensor possesses a variety of advantages including easy maintenance of enzyme, simplicity of construction, fast response time and high stability. Received: 13 May 1996 / Revised: 30 July 1996 / Accepted: 2 August 1996  相似文献   

9.
Kalaycı S  Somer G  Ekmekci G 《Talanta》2005,65(1):87-91
An electrode for glucose has been prepared by using an iodide selective electrode with the glucose oxidase enzyme. The iodide selective electrode used was prepared from 10% TDMAI and PVC according our previous study. The enzyme was immobilized on the iodide electrode by holding it at pH 7 phosphate buffer for 10 min at room temperature. The H2O2 formed from the reaction of glucose was determined from the decrease of iodide concentration that was present in the reaction cell. The iodide concentration was followed from the change of potential of iodide selective electrode. The potential change was linear in the 4×10−4 to 4×10−3 M glucose concentration (75-650 mg glucose/100ml blood) range. The slope of the linear portion was about 79 mV per decade change in glucose concentration. Glucose contents of some blood samples were determined with the new electrode and consistency was obtained with a colorimetric method. The effects of pH, iodide concentration, the amount of enzyme immobilized and the operating temperature were studied. No interference of ascorbic acid, uric acid, iron(III) and Cu(II) was observed. Since the iodide electrode used was not an AgI-Ag2S electrode, there was no interference of common ions such as chloride present in biological fluids. The slope of the electrode did not change for about 65 days when used 3 times a day.  相似文献   

10.
We report a prototype air‐breathing carbon cloth‐based electrode that was fabricated starting from a commercially available screen‐printed electrode equipped with a transparent ITO working electrode (DropSens, ref. ITO10). The fabrication of the air‐breathing electrodes is straightforward, shows satisfactory reproducibility and a good electrochemical response as evaluated by means of [Fe(CN)6]3?/4? voltammetry. The gas‐diffusion electrodes were successfully modified with the O2 reducing enzyme bilirubin oxidase from Myrothecium verrucaria in a direct electron transfer regime. The enzyme modified electrodes showed a remarkable high current density for O2 reduction in passive air‐breathing mode of up to 5 mA cm?2. Moreover, the enzyme modified electrodes were applied as O2 reducing biocathodes in a glucose/air enzymatic biofuel cell in combination with a high current density glucose oxidase/redox polymer bioanode. The biofuel cell provides a high maximum power density of (0.34±0.02) mW cm?2 at 0.25 V. The straightforward design, low cost and the high reproducibility of these electrodes are considered as basis for standardized measurements under gas‐breathing conditions and for high throughput screening of gas converting (bio‐)catalysts.  相似文献   

11.
《Electroanalysis》2004,16(9):736-740
A new enzyme‐based amperometric biosensor for hydrogen peroxide was developed relying on the efficient immobilization of horseradish peroxidase (HRP) to a nano‐scaled particulate gold (nano‐Au) film modified glassy carbon electrode (GC). The nano‐Au film was obtained by a chitosan film which was first formed on the surface of GC. The high affinity of chitosan for nano‐Au associated with its amino groups resulted in the formation of nano‐Au film on the surface of GC. The film formed served as an intermediator to retain high efficient and stable immobilization of the enzyme. H2O2 was detected using hydroquinone as an electron mediator to transfer electrons between the electrode and HRP. The HRP immobilized on nano‐Au film maintained excellent electrocatalytical activity to the reduction of H2O2. The experimental parameters such as the operating potential of the working electrode, mediator concentration and pH of background electrolyte were optimized for best analytical performance of amperometry. The linear range of detection for H2O2 is from 6.1×10?6 to 1.8×10?3 mol L?1 with a detection limit of 6.1 μmol L?1 based on signal/noise=3. The proposed HRP enzyme sensor has the features of high sensitivity (0.25 Almol?1cm?2), fast response time (t90%≤10 s) and a long‐term stability (>1 month). As an extension, glucose oxidase (GOD) was chemically bound to HRP‐modified electrode. A GOD/HRP bienzyme‐modified electrode formed in this way can be applied to the determination of glucose with satisfactory performance.  相似文献   

12.
A new technique has been established to fabricate thin film composite membranes, by which a hydrophilic polymer could be coated in thin film on a hydrophobic support membrane. The new technique was composed of two steps: dispersion of a reactant to the hydrophilic polymer in the hydrophobic support membrane and interfacial reaction between the reactant and the hydrophilic polymer to produce thin film of the hydrophilic polymer on the support membrane. Composite membranes in which a thin film of sodium alginate is coated on a polysulfone support membrane were prepared by the new technique for the reverse osmosis separation of anionic surfactant–water mixture. Two methods were employed to fabricate a thin film of sodium alginate on the support membrane: (1) dispersion of the crosslinking agent, CaCl2 alone in the support membrane and (2) dispersion of CaCl2 in the support membrane with help of PVA which adheres fast to the support membrane. The formation mechanism of the thin layer was suggested schematically on each method. Both the methods could produce successively a thin layer of SA on the support membrane. Especially, method (2) gave a strong bonding of the thin layer on the support because of the large contact area with the support through the PVA layer which sticks fast to the SA layer. From the SEM pictures and permeation experiments, the method (2) was confirmed to be better to produce a defect-free thin film of SA on the support membrane.  相似文献   

13.
Luminous membranes were prepared by immobilizing peroxidase (POD) to collagen matrix. The POD luminous membrane generated luninescence in the presence of luminol and H2O2, and the peroxide was determined in the concentration range 10-6-10-3 M by following luminescence emitted from the membrane. Glucose was determined using a luminous membrane in which POD and glucose oxidase (GOD) were coimmobilized. The luminous membranes appear to be feasible for the determination of enzyme substrates and enzyme activity.  相似文献   

14.
Multilayer thin films of poly(ethylene oxide) (PEO) and poly(methacrylic acid) (PMAA), deposited via layer‐by‐layer (LbL) assembly from aqueous solutions, are investigated for CO2/N2 separation. Eight and ten bilayer (217 and 389 nm thick, respectively) PEO/PMAA thin films deposited on a 25 μm polystyrene substrate exhibit CO2/N2 selectivities of 142 and 136, respectively. These are the highest reported to‐date for this gas pair separation using a homogeneous polymer film. While further work remains to improve CO2 permeability, these results indicate the potential of LbL assemblies as standalone CO2 separation membranes for low‐flux/high‐purity applications, or as part of a composite and/or mixed‐matrix membrane for high‐flux applications. © 2017 Wiley Periodicals, Inc. J. Polym. Sci., Part B: Polym. Phys. 2017 , 55, 1730–1737  相似文献   

15.
We prepared Nafion/PTFE (NF) and zirconium phosphate (ZrP) hybridized Nafion/PTFE composite membranes (NF–ZrP). NF–ZrP composite membranes were prepared via two processes. One is impregnating sub-μm porous PTFE membrane directly in a Nafion/ZrOCl2 solution (NF–Zr–d). The other is impregnating sub-μm porous PTFE membrane in a Nafion solution to prepare NF composite membrane, and then the NF membrane was impregnated in a ZrOCl2 aqueous solution via in situ precipitation method (NF–Zr–I). The ZrOCl2 inserted in NF composite membranes was then reacted with phosphoric acid to form ZrP and thus NF–ZrP–d and NF–ZrP–I composite membranes were obtained. The direct methanol fuel cell (DMFC) performances of membrane electrode assemblies prepared from Nafion-117, NF, NF–ZrP–d, and NF–ZrP–I composite membranes were investigated. The effects of introducing sub-μm porous PTFE film and ZrP particles into Nafion membranes on the DMFC performance were investigated. The influence of ZrP hybridizing process into NF membranes (the process of preparing NF–ZrP–I is inserting ZrOCl2 into NF membranes after Nafion is annealed and the process of preparing NF–ZrP–d is mixing ZrOCl2 into a Nafion solution before Nafion is annealed) on the morphology of NF–ZrP composite membranes and thus on the DMFC performance was also discussed.  相似文献   

16.
Membranes Nafion 117 are modified with poly(3,4-ethylenedioxythiophene) (PEDT) by chemical polymerization of EDT with H2O2 or FeCl3 as the oxidants in a two-compartment cell. Depending on the oxidant and polymerization conditions, PEDT is deposited either as a thin film on the membrane surface or inside the Nafion membrane depending on whether FeCl3 or H2O2 is used as the oxidant. The decrease in the ionic conductivity and methanol permeability is studied as a function of the polymerization time. A linear dependence is found with H2O2 and a t −1/2 dependence, with FeCl3. The contributions of PEDT and Nafion to the overall conductivity of the composite membranes are separated by impedance measurements. The modified membranes (FeCl3) are also tested in direct methanol fuel cells (DMFC). The methanol permeation through the membranes is measured by operating the fuel cell in an electrolysis mode. The influence of the modified membranes on the DMFC current-voltage characteristics is studied with 2 M CH3OH and O2 at 1.2 barabs and 80°C. Membrane electrode assemblies (MEAs) are prepared by hot pressing the modified membrane between two commercial gas diffusion electrodes with 1 mg cm−2 of Pt loading. A decrease of the methanol permeation of 25% is observed at MEA with the modified membrane (1 h polymerization time), compared with that of MEA with a Nafion membrane. However, the overall DMFC performance decreases in the same relation: a maximal power density of 36 W cm−2 is measured at MEA with a PEDT-modified membrane compared with 45 W cm−2 for MEA with a Nafion membrane. Published in Russian in Elektrokhimiya, 2006, Vol. 42, No. 11, pp. 1330–1339. Based on the report delivered at the 8th International Frumkin Symposium “Kinetics of the Electrode Processes,” October 18–22, 2005, Moscow. The text was submitted by the authors in English.  相似文献   

17.
We investigated a L ‐phenylalanine (L ‐phe) biosensor, functionalized through enzyme immobilization on a polymer‐blend film. The electron mediator 3,4‐dihydroxybenzaldehyde (3,4‐DHB) was employed at the electrode surface to improve direct oxidation of NADH to NAD+ and no additional reagents is required to be added to the sample solution. The bioactivated electrode was coated with a semi‐permeable cellulose acetate membrane in order to prevent dissolution of biofunctionalized polymer‐blend film. This constructed enzyme electrode is the first selective biosensor for phenylketonuria (PKU) detection. The sensitivity of the enzyme electrode was determined as 12.014 mA/M cm2. The Michaelis–Menten and current responses as well as sensitivity of the electrode showed improved values than those of previous works. This selective biosensor presented an excellent electroanalytical response for L ‐phe, with a high steady‐state current being obtained after 20 s. The sensitivity of our biodevice is quite sufficient for the purpose of PKU detection because the reference range of clinical concern for L ‐phenylalanine concentration is CL ‐phe>0.5 mM. This surface‐bioactivated enzyme electrode retained more than 80 % of its electrocatalytic activity after 16 days.  相似文献   

18.
We have used solvent casting techniques to immobilise glucose oxidase (GOD) within unplasticised and plasticised poly(vinyl chloride) (PVC) matrices. The plasticisers studied were the cationic surfactant, tricaprylmethylammonium chloride (Aliquat 336s), the anionic surfactant bis(2-ethylhexyl) hydrogenphosphate (BEP) and the lipid, isopropylmyristate (IPM). The activity of the enzyme-membrane was tested by amperometric electrode. Changes in enzyme-membrane electrode response are rationalised on the basis of membrane permselective properties. The Aliquat and IPM modified PVC membranes gave amplified signals due to better retention and subsequent concentration of the H2O2 signal species. Effectively, less was being lost to the bulk solution. In the case of the BEP-modified membrane, while there was a linear step change in response up to 50 mM, at higher concentrations, responses did not reach steady-state; they were characterised by an upward drift in response of 0.050 nA/min. This characteristic is thought to be due to a build up of gluconic acid resulting in a pH reduction in the membrane microenvironment and hydrogen bonding between neighbouring BEP molecules. Under these conditions, we have previously shown that the membrane permeability to hydrophilic species is attenuated and it is tentatively suggested that the upward drift due to the build up of H2O2 on the electrode side with less permeating through the acidified membrane into bulk solution.The results were compared against using variously plasticised PVC (but no enzyme entrapped) as an outer membrane of a classical dual-membrane glucose enzyme electrode construct. In the latter case, the enzyme was chemically crosslinked between the membranes using glutaraldehyde.  相似文献   

19.
In this study, a new class of heterogeneous membranes based on cellulose acetate (CA) polymer and a complex filler clay‐silica nanowires (SiO2NWs) was investigated for potential biomedical applications. SiO2NWs were synthesized using natural clay through a facile sol–gel method and were dispersed in the polymer solution by sonication in the 1.25, 2.5, and 5% weight ratio to the CA acetate polymer. Membranes were subsequently prepared via phase inversion by precipitation of the CA polymer in water. The pristine CA membrane and SiO2NWs based nanocomposites membranes were characterized using different characterization techniques. The presence of the SiO2NWs in the CA membrane was found to significantly enhance the protein retention, water wettability and thermal as well as mechanical properties in comparison to the pristine CA membrane. Water flows studies at different temperatures and the retention of bovine serum albumin have been studied and the nanocomposite membranes were found to exhibit superior performances compared with the pristine CA membranes. SiO2NWs‐CA membranes showed a much higher stability to the water temperature change during separation than CA membranes. Morphological changes clearly revealed that the composite membrane were much more compact than the pristine CA membranes. The rabbit dermal fibroblasts cell viability in cultures after 72 hr of incubation was found to be greater than 80%. These newly synthesized composite membranes exhibit a high potential to be used for various medical applications because of their non‐cytotoxic characteristics. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
The fabrication of amperometric biosensors based on whole cell Gluconobacter oxydans DSMZ 2343 (G. oxydans) and glucose oxidase (GOx) was performed for the detection of glucose. Glassy carbon electrodes (GCE) were coated with a 10-(4H-dithiyeno [3,2-b:2’,3’-d]pyroll-4-il)decan-1-amine (DTP-alkyl-NH2) polymer using an electropolymerization method and the formed interface was used to connect the bacteria and the enzyme to the electrode. The transfer of electrons from enzyme to electrode was successfully demonstrated by the biocatalytic activity and unique morphology of the conducting polymer. Characterization of the biosensors was assessed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM) analyses. The detection limits of the enzyme and microbial based biosensors for glucose were 0.022 and 0.081?mM, respectively. The broad linear dynamic ranges of the GOx and G. oxydans biosensors were observed to be 0.045–50.0 and 0.19–50.0?mM, respectively. The analytical performances of biosensors were compared according to the following figures of merit: detection limits, limits of quantification, pH and current response time. In addition, to demonstrate the applicability of the biosensors, real-time measurements and recovery studies were evaluated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号