首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Two bonded chiral stationary phases (CSPs), 8-aminoquinoline-2-ylmethyl- and 8-aminoquinoline-7-ylmethyl-diaza-18-crown-6-capped [3-(2-O-beta-cyclodextrin)-2-hydroxypropoxy]propylsilyl silica particles (non-porous, 1.5 microm), have been prepared and evaluated using capillary liquid chromatography at high pressures (> or = 8000 p.s.i.). High column efficiency (up to 400 000 plates m(-1)) was achieved for chiral separations. These CSPs with two recognition sites, i.e. substituted-diaza-18-crown-6 and beta-cyclodextrin combined with high chromatographic efficiency provide good resolution of a variety of enantiomers and positional isomers in relatively short times under reversed-phase conditions. After inclusion of a Ni (II) ion from the mobile phase, the positively charged crown ether-capped beta-cyclodextrin facilitates specific static, dipolar, and host-guest complexation interactions with solutes.  相似文献   

2.
OV-17负载交联β-环糊精聚合物毛细管柱的研制   总被引:6,自引:0,他引:6  
陈国斌  唐阔文 《色谱》2000,18(4):343-345
 合成了一种非水溶性交联 β 环糊精聚合物。环糊精聚合物在异丙醚、二氯甲烷和苯的混合溶剂中 ,经超声波处理 0 5h ,配成质量浓度为 2 6g/L的溶胶状固定液 ,并采用超动态法成功地将其涂渍到弹性石英毛细管柱上。该毛细管柱柱效高达 30 0 0·m- 1 ,热稳定性好 ,属中等极性。对二甲苯和二氯苯芳香位置异构体及α 蒎烯、β 蒎烯、乳酸乙酯、α 苯乙醇、1 ,2 丙二醇、α 紫萝酮、α 氯代丙酸甲酯、γ 戊内酯等对映体进行了色谱分离。实验表明 ,经超声波处理过的非水溶性交联 β 环糊精聚合物适合作毛细管气相色谱固定相。  相似文献   

3.
A novel open‐tubular capillary electrochromatography column coated with β‐cyclodextrin was prepared using the sol‐gel technique. In the sol‐gel approach, owing to the three‐dimensional network of sol‐gel and the strong chemical bond between the stationary phase and the surface of capillary columns, good chromatographic characteristics and unique selectivity in separating enantiomers were shown. The influences of capillary inner diameter, coating time, organic modifier, buffer pH, and buffer concentration on separation were investigated. The sol‐gel‐coated β‐cyclodextrin column has shown improved enantioseparation efficiency of chlorphenamine, brompheniramine, pheniramine, zopiclone in comparison with the sol‐gel matrix capillary column. The migration time relative standard deviation of the separation of the enantiomers was less than 0.89% over five runs and 2.9% from column to column. This work confirmed that gold nanoparticles are promising electrochromatographic support to enhance the phase ratio of open‐tubular capillary electrochromatography column in capillary electrochromatography.  相似文献   

4.
Wang Y  Zeng Z  Guan N  Cheng J 《Electrophoresis》2001,22(11):2167-2172
A novel open-tubular capillary electrochromatography (OT-CEC) column coated with 2,6-dibutyl-beta-cyclodextrin (DB-beta-CD) was prepared using sol-gel technique. In the sol-gel approach, owing to the three-dimensional network of sol-gel and the strong chemical bond between the stationary phase and the surface of capillary columns, good chromatographic characteristics and unique selectivity in separating isomers were shown. We achieved high efficiencies of 5-14 x 10(4) plates/m for the isomeric nitrophenols using the sol-gel-derived DB-beta-CD columns. The migration time reproducibility of the separation of the isomeric nitrophenols was better than 2.2% over five runs and 4.5% from column to column. These sol-gel-coated DB-beta-CD columns have shown improved separations of isomeric aminophenols, isomeric dihydroxybenzenes and isomeric nitrophenols, in comparison with the sol-gel matrix capillary column. The influences of buffer pH and methanol solvent on separation were investigated. The chiral resolution of enantiomers such as ibuprofen and binaphthol was explored primarily.  相似文献   

5.
将自制的非水溶性环糊精聚合物成溶胶,将该溶胶充满柱放置一段时间,固定相微粒均匀地吸附在柱壁上,制备了高效率的玻璃毛细管柱。测试了所制备柱的性能并对某些化合物进行了分离。  相似文献   

6.
Porous organic cages composed of discrete cage molecules have attracted considerable recent attention as gas adsorption materials and separation media. In this study, we report a homochiral porous organic cage CC5 with a large cavity and pore windows as a novel stationary phase for high‐resolution gas chromatographic separations. The capillary column was prepared by a static coating method. A large number of racemic compounds have been resolved on the coated capillary column, including derivatized amino acids, alcohols, alcohol amines, esters, ethers, ketones, and epoxides. It is interesting that the CC5‐coated capillary column exhibits significant chiral recognition complementarity to a commercial β‐DEX 120 column and a previously reported homochiral porous organic cage CC3‐R‐coated column, which could expand the range of the analytes amenable to separation on porous organic cage‐based capillary columns. Moreover, the fabricated column also shows excellent selectivity for the separation of positional isomers, including the challenging ethylbenzene and xylene isomers. Experimental results demonstrate an excellent separation performance and stability of the CC5‐coated column, making it promising for gas chromatography applications.  相似文献   

7.
Xu L  Sun Y 《Electrophoresis》2008,29(4):880-888
A novel stationary phase with tentacle-type polymer chains with epoxy groups was fabricated for open tubular CEC. The fabrication procedure of the stationary phase included pretreatment of capillary inner wall, silanization, and glycidyl methacrylate (GMA)-grafted polymerization. The influence of initiator concentration and polymerization time on the resulting polymer stationary phase was studied by measuring EOF mobility and hydrophobicity of the prepared capillary column. SEM showed that the capillary inner wall was evenly coated with a polymer film showing a wrinkly surface. The prepared GMA-grafted stationary phase could be easily modified with different chromatographic ligands by the ring-opening reaction of the epoxy groups. In this study, phenylalanine (Phe) was selected as the ligand. Benzene derivatives and three amino acids were then separated, respectively, using the Phe modified tentacle-type capillary column. As a control, separations were also performed on a monolayer Phe-modified capillary. The tentacle-type polymer stationary phase was found affording stronger retention and better resolution in the separation of benzene derivatives and tryptophan, tyrosine, and Phe mixtures compared with the monolayer stationary phase.  相似文献   

8.
V Schurig  D Wistuba 《Electrophoresis》1999,20(12):2313-2328
Enantiomer separation by electrochromatography employing modified cyclodextrins as stationary phases is performed in two ways. (i) Polysiloxane-linked permethylated beta-cyclodextrin (Chirasil-Dex 1) or related selectors are coated and immobilized onto the inner surface of a capillary column. Enantiomer separation is performed in the open tube and the method is referred to as open-tubular capillary electrochromatography (o-CEC). (ii) Silica-linked native beta-cyclodextrin, permethylated beta-cyclodextrin (Chira-Dex 2) or hydroxypropyl-beta-cyclodextrin are filled into a capillary column and the bed is secured by two frits. Enantiomer separation is performed in a packed column and the method is referred to as packed capillary electrochromatography (p-CEC). In a unified instrumental approach, method (i) as well as method (ii) can be operated both in the electro- and pressure-driven modes (o-CEC vs. open-tubular liquid chromatography (o-LC) and p-CEC vs. p-LC). It is demonstrated that the electro-driven variant affords higher efficiencies at comparable elution times. Employing a single open-tubular column coated with Chirasil-Dex 1, a unified enantioselective approach can be realized in which the same selectand is separated using all existing chromatographic modes for enantiomers, i.e., gas chromatography (GC), super-critical fluid chromatography (SFC), o-LC and o-CEC. As the chiral selector is utilized as a stationary phase, an additional chiral selector may be added to the mobile phase. In the resulting dual chiral recognition systems, enhancement of enantioselectivity (matched case) or compensation of enantioselectivity (mismatched case) may be observed. The overall enantioselectivity is dependent on the sense of enantioselectivity of the selectors chosen and their influence on the electrophoretic and electroosmotic migration of the enantiomers of a selectand.  相似文献   

9.
提出一种制备双羧基冠醚玻璃空心柱的新方法,对其色谱特性研究表明:用该法研制的双羧基冠醚空心柱色谱性能良好,对某些极性位置异构体的分离有特殊的选择性,还探讨了反应机理及影响分离的各种因素。  相似文献   

10.
The performance of a monolithic silica capillary column coated with poly(octadecyl methacrylate) (ODM column) for the reversed-phase liquid chromatographic separation of some polar and non-polar compounds was studied, and the results were compared to those obtained by using a monolithic silica capillary column modified with octadecylsilyl-(N,N-diethylamino)silane (ODS column). Benzene and naphthalene derivatives, polycyclic aromatic hydrocarbons (PAHs), steroids, alkyl phthalates, and tocopherol homologues were used as test samples. In general, compounds with aromatic character, rigid and planar structures, and lower length-to-breadth ratios (more compacted structures) seem to have more preference for the polymer coated stationary phase (ODM). Compounds with acidic character have also a higher retention on ODM columns because of the presence of ester groups in the stationary phase. The polymer coated column allowed the separation of some PAHs, alkyl phthalates, steroids, and of beta- and gamma-tocopherol isomers which cannot be separated under the same conditions on ODS columns, while keeping similar column efficiency. These results allowed to suggest ODM columns as a good alternative to conventional ODS columns for reversed-phase liquid chromatography.  相似文献   

11.
Three columns were used for the gas chromatographic analysis of polycyclic aromatic hydrocarbons (PAHs) with relative molecular masses (Mr) up to 450. Two of the columns were commercially available, coated with a 50% methyltrifluoropropyl-substituted polysiloxane a 5% diphenyl-substituted methylpolysiloxane. The third column was laboratory made, coated with a biphenyl-substituted silarylene-siloxane copolymer. All three columns were utilized for the analysis of high-Mr PAHs as regards both thermal stability of the stationary phases, i.e., low bleeding rate, and chromatographic efficiency. The column coated with a trifluoropropyl-substituted stationary phase showed, however, a low separation efficiency, possibly owing to low solute stationary phase compatibility. The biphenyl-substituted stationary phase, on the other hand, showed a very high separation efficiency, but the retention of the PAHs was significantly higher on this column compared with the other two, leading to the demand for higher oven temperatures. Different retention mechanisms were observed on these columns, as shown by differences in the retention indices of the PAHs measured in a system using PAHs as retention index markers. A comparatively faster elution of non-planar PAHs was observed on the columns coated with the trifluoropropyl-substituted stationary phase and the biphenyl-substituted stationary phase compared with the column coated with the 5% diphenyl-substituted polymer. The usefulness of the columns for separations of high-Mr PAHs is demonstrated by gas chromatograms of carbon black extracts and a coal tar extract standard reference material.  相似文献   

12.
将甲氧甲基引入β-环糊精的2,3,6-位合成了新的气相色谱手性固定相七(2,3,6-三-O-甲氧甲基)-β-环糊精,并采用静态法将其涂渍在毛细管内壁制备毛细管气相色谱柱。考察了毛细管柱的柱性能和分离性能。结果表明该固定相对Grob试剂、苯的二取代位置异构体(硝基甲苯、溴甲苯、二氯苯和二甲苯)及手性化合物(2-羟基丙酸甲酯、2-羟基丙酸乙酯和2-甲磺酰基丙酸甲酯)都具有良好的分离效果。与固定相2,3,6-三-O-甲基-β-环糊精的手性分离效果对比,结果显示两种手性固定相的分离能力各异,对一些手性脂类化合物对映体的分离存在互补性。  相似文献   

13.
Ye M  Zou H  Lei Z  Wu R  Liu Z  Ni J 《Electrophoresis》2001,22(3):518-525
A novel mode of capillary electrochromatography (CEC) based on a dynamically modified stationary phase was presented for chiral separation. The capillary column was packed with strong anion-exchange (SAX) stationary phase packing; the sulfated beta-cyclodextrin (S-CD), which was added to the mobile phase, was dynamically adsorbed to the packing surface. Separation of enantiomers was achieved by their different abilities to form an inclusion complex with the adsorbed S-CD. The enantiomers of tryptophan, praziquantel, atropine, metoprolol, and verapamil were successfully separated in this system with a column efficiency of 36000-412000 plates/m. The resolution value obtained for atropine was as high as 11.23. The superiority of CEC with a dynamically modified stationary phase over that with a physically adsorbed stationary phase was demonstrated. The influence of ionic strength, S-CD concentration, and methanol content on separation was also studied.  相似文献   

14.
Crosslinking experiments for the chiral stationary phase OV-225-L-Val-t-butylamide within both fused silica and glass capillary columns have been carried out. Amino acid enantiomers were separated on crosslinked columns by both GC and SFC methods. In SFC, the a values of amino acid enantiomers are independent of the density of the mobile phase, and they are hig her than those obtained by GC for the tested enantiomers with the same column due to the lower column temperature used in SFC.  相似文献   

15.
Summary The synthesis of methylphenylpolysiloxane polymers and their use in the preparation of crosslinked, non-extractable stationary phases for fused-silica capillary columns are described. By preparing more viscous phenyl-containing polymers than are commercially available, stationary phase films of these polymers could be efficiently coated on fused-silica capillary columns and stabilized by a free radical crosslinking mechanism using peroxides. Four methylphenylpolysiloxane polymers containing different phenyl concentrations were prepared. These included three polymers containing 50% phenyl and one polymer containing 70% phenyl. Two of the 50% phenyl polymers had one phenyl and one methyl group attached to each silicon atom. One of these also had 1% vinyl incorporated. The third 50% phenyl polymer was synthesized in such a way that one half of the silicon atoms had two phenyl groups attached while the rest contained dimethyl groups. The 70% phenyl polymer also had 4% vinyl incorporated. Due to the intrinsic thermal stability of these phenyl phases and the enhanced film stability achieved by crosslinking, the 70% phenyl phase could be utilized up to 400 °C. Using the methods described in this paper, highly efficient and thermally stable fused silica capillary columns coated with crosslinked methylphenylpolysiloxane stationary phases can be successfully prepared.  相似文献   

16.
合成了2,6-二-O-戊基-β-环糊精键合硅胶固定相(PCDS)。利用傅里叶红外光谱、X射线光电子能谱、莫氏(Molisch)试验颜色反应对其进行了表征。以邻苯二甲酸二甲酯、甲苯和菲为测试溶质,评价该键合固定相的色谱性能,并考察了该固定相对一些位置异构体的色谱分离效果,讨论了可能的分离机理。  相似文献   

17.
Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene inside a 200 microm i.d. fused silica capillary using a mixture of tetrahydrofuran and decanol as porogen. Important chromatographic features of the synthesized columns were characterized and critically compared to the properties of columns packed with micropellicular, octadecylated poly(styrene-co-divinylbenzene) (PS-DVB-C18) particles. The permeability of a 60 mm long monolithic column was slightly higher than that of an equally dimensioned column packed with PS-DVB-C18 beads and was invariant up to at least 250 bar column inlet pressure, indicating the high-pressure stability of the monolithic columns. Interestingly, monolithic columns showed a 3.6 times better separation efficiency for oligonucleotides than granular columns. To study differences of the molecular diffusion processes between granular and monolithic columns, Van Deemter plots were measured. Due to the favorable pore structure of monolithic columns all kind of diffusional band broadening was reduced two to five times. Using inverse size-exclusion chromatography a total porosity of 70% was determined, which consisted of internodule porosity (20%) and internal porosity (50%). The observed fast mass transfer and the resulting high separation efficiency suggested that the surface of the monolithic stationary phase is rather rough and does not feature real pores accessible to macromolecular analytes such as polypeptides or oligonucleotides. The maximum analytical loading capacity of monolithic columns for oligonucleotides was found to be in the region of 500 fmol, which compared well to the loading capacity of the granular columns. Batch-to-batch reproducibility proved to be better with granular stationary phases compared to monolithic stationary phase, in which each column bed is the result of a unique column preparation process.  相似文献   

18.
Chen Z  Ozawa H  Uchiyama K  Hobo T 《Electrophoresis》2003,24(15):2550-2558
We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 microm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. Gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. Beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.  相似文献   

19.
Unique stationary phases of octadecylsilica (ODS) coated with acylcarnitines have been developed for liquid chromatographic columns. The ODS column coated with acylcarnitine was readily prepared by recycling the solution containing acylcarnitine through an ODS column in a closed loop. Acylcarnitine was adsorbed on the ODS surfaces by hydrophobic interaction between the acyl group of acylcarnitine and the octadecyl group of the ODS phases. The ODS column coated with stearoylcarnitine (CN-18 column) was the most stable among the four columns coated with acylcarnitines of various acyl chain lengths (decanoylcarnitine, lauroylcarnitine, myristoylcarnitine, and stearoylcarnitine) under the condition of delivery of the mobile phase, indicating that adsorption of acylcarnitine on the ODS surfaces depended on the length of acyl chains. The CN-18 column was usable for delivering the mobile phase contained less than 20% (v/v) acetonitrile, retaining almost the same separation efficiency as the intact ODS column. The retention behavior of ionic solutes on the CN-18 column could be explained by both ionic and electrostatic interactions between the solutes and the stationary phase. The CN-18 column enabled efficient separation of inorganic anions, nicotinic acids, amino acids, and nucleotides. The chiral ODS column coated with enantiomer of stearoylcarnitine, L-stearoylcarnitine (L-CN-18 column) could achieve direct enantiomeric separation of DL-tryptophan, alpha-methyl-DL-tryptophan and DL-3-indolelactic acid using 100% water as the mobile phase. The L-CN-18 column could also separate enantiomers of amino acids and alpha-hydroxycarboxylic acids by ligand-exchange chromatographic mode using a mobile phase containing copper(II) ion. The chiral recognition is discussed for enantiomeric separation on the L-CN-18 column.  相似文献   

20.
A novel open‐tubular CEC column coated with chitosan‐graft‐(β‐CD) (CDCS) was prepared using sol‐gel technique. In the sol‐gel approach, owing to the 3D network of sol‐gel and the strong chemical bond between the stationary phase and the surface of capillary columns, good chromatographic characteristics and unique selectivity in separating isomers were shown. The column efficiencies of 55 000~163 000 plates/m for the isomeric xanthopterin and phenoxy acid herbicides using the sol‐gel‐derived CDCS columns were achieved. Good stabilities were demonstrated that the RSD values for the retention time of thiourea and isoxanthopterin were 1.3 and 1.4% (run to run, n = 5), 1.6 and 2.0% (day to day, n = 3), 2.9 and 3.1% (column to column, n = 3), respectively. The sol‐gel‐coated CDCS columns have shown improved separations of isomeric xanthopterin in comparison with CDCS‐bonded capillary column.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号