首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
A serially coupled column system for capillary supercritical fluid chromatography was constructed by connecting two capillary columns of different polarities using or without using a coupling restrictor. The influence of the column sequence, the size of the coupling restrictor and the column temperature on the polarity of the system were studied. The system without a coupling restrictor (the directly coupled system) provided an intermediate polarity between two columns, depending on the column geometry, such as the film thickness and column length, although it slightly shifted to that of the first column. In the system with a coupling restrictor, the contribution of the second column to the overall retention increased with its resistance. The use of a coupling restrictor allowed to control the polarity of the coupled system virtually over the whole range between two columns. The temperature was an additional effective parameter for tuning the polarity of the system.  相似文献   

2.
The enantioselective tuning of two columns coupled in series is investigated in chiral high-resolution gas chromatography. Two columns with opposite enantioselectivities (Chirasil-L-Val and Chirasil-D-Val) are coupled in series via a T connector, and the relative retention of enantiomers chromatographed on the system is changed by varying the individual carrier gas flow rates in the coupled columns. The flow-rate ratio necessary for the required selectivity is calculated on the basis of the measured retention factors on the individual columns. The performance of this method for adjusting selectivity is studied by the separation of enantiomers of the N-TFA-O-methyl esters of six amino acids. It is demonstrated that the change of the coupling point carrier gas pressure, at the constant inlet and outlet pressures, may change the enantioselectivity of the given column series to such an extent that the enantiomer elution order may be reversed.  相似文献   

3.
Wide use of a combination of gas chromatographic (GC) separations with mass spectroscopic detection causes the necessity to study the effect of the relative pressure in a capillary column on its efficiency and separation properties. Using n-decane as a sorbate, a decrease in the relative pressure was shown to induce a slight increase in the efficiency of polar capillary columns but results in a considerable decrease in the optimal flow rate of the mobile phase and strongly constricts the Van-Deemter curve profile. In the presence of the restrictor, even minor deviations from the optimal flow rate can result in a considerable decrease in the column efficiency. Since the capillary restrictor is often a component of the interface between the column and mass spectrometer, it is necessary to exactly maintain the optimal operation conditions of the GC column to achieve an optimal efficiency of separation.  相似文献   

4.
李莉  李硕  王海燕  孙磊 《色谱》2022,40(2):190-197
以化妆品中23种防腐剂检测方法为例,探讨色谱柱选择对液相色谱方法测定结果的影响。参照《化妆品安全技术规范》甲基异噻唑啉酮等23个组分的检验方法,在2台不同的高效液相色谱仪上用15款不同品牌、型号的C18色谱柱检测23种防腐剂,计算色谱峰的理论塔板数和分离度,对23种组分的分离效果进行分析,并应用USP (United States Pharmacopeia)数据库和PQRI (Product Quality Research Institute)数据库等2种等效色谱柱选择方法,对不同色谱柱的分离效果及等效性进行评价和预测。实验结果表明,15款色谱柱对23种防腐剂的分离效果差异显著,仅有2款色谱柱可以实现23种组分的完全分离。USP和PQRI数据库中2种等效色谱柱选择方法均无法预测出合适的等效色谱柱,对23种防腐剂的液相色谱分析参考价值均较小。色谱柱是影响23种防腐剂液相色谱法测定结果准确性的关键因素,有关实验室在应用该方法时,应考虑色谱柱选择性差异。化妆品基质复杂,如何在现有研究成果的基础上,开发色谱柱的筛选和预测评价体系,进而指导实际样品的分离是下一步研究的重点、难点。建议有关部门在制修订检测方法时,注重色谱柱的耐用性考察,完善系统适应性指标,细化色谱柱分类和增加描述信息,指导色谱柱的合理选择,从而规避由于色谱柱使用过程中选择依据缺失而导致测定结果不准确的风险。  相似文献   

5.
Silica gel was used as a support for the covalent coupling of liposomes, which could overcome drawbacks of soft gel beads in column efficiency and separation speed. The influences of the concentration of added dimethylaminopyridine and reaction time on the chloroformate activation reaction of silica gel were investigated. Temperature and pH for covalent coupling of liposomes on the activated silica gel were also optimized. Experimental results indicated that the stability of the covalently coupled liposome columns was obviously superior to that of the noncovalently coated liposome columns but the selectivity of both columns was basically identical. Separation and analysis of a crude extract of a traditional Chinese medicine Ligusticum Wallichii and a mixture of small peptides on both columns further support this conclusion.  相似文献   

6.
Remote control of the vent/detector split flow ratio in packed column supercritical fluid chromatography (pSFC) with flame ionization detector (FID) is demonstrated using a dual heated restrictor method. Restrictors stemming from a Tee at the separation column outlet were, respectively, fixed into an FID and a vent port, and their individual temperatures were controlled using resistively heated wires. Subsequently, both system pressure and split flow could be manipulated. For example, for applied restrictor temperatures examined up to 600°C, corresponding vent/FID split flow ratios between 2 and 7 were observed depending on the port heated. As well, column pressures around 16–23 MPa were also achievable over the same range. Conversely, isobaric altering of the split flow ratio was possible when opposing positive and negative temperature gradients were applied at the two restrictors. Under these conditions, the system pressure varied less than 1% RSD over a 10 min period. As an application, the method was used to establish stable detector operation in the analysis of n‐alkanes under pSFC‐FID conditions that initiated flame instability. Results indicate that this technique could be a relatively simple and inexpensive means of controlling system pressure and detector split flow ratios in pSFC‐FID.  相似文献   

7.
A procedure was developed for modelling the gas chromatographic separation on a system of columns coupled in series. This procedure can be used for computer based optimization of lengths and order of serially coupled columns at isothermal conditions. The sample component retention factors and column resistances needed for the model can easily be measured on each individual column. The proposed procedure was verified by analyzing a 52 component hydrocarbon mixture on three columns of different polarity coupled in series by various column orders. Good agreement between experimental and calculated retention data was found. The procedure is also well suited for optimization of the chromatographic selectivity by coupling columns with different selectivity in series.Dedicated to Professor Dr. h.c. mult. J.F.K. Huber on the occasion of his 70th birthday  相似文献   

8.
A new packed column SFC method has been developed for the determination of phytanic acid in human blood serum. Because of the low viscosity and high diffusion coefficient of supercritical carbon dioxide, several columns can be connected in series, significantly improving separation. Series connection of columns which differ in their selectivity enables the adjustment of the total selectivity towards the individual separation problem (‘selectivity tuning’). In this instance it was possible, after transesterification into their ethyl esters, to separate all the fatty acids in human blood serum, including phytanic acid, by coupling three columns (silica, amino-propyl, and RP8) in series.  相似文献   

9.
Hydrophilic interaction liquid chromatography is a separation technique suitable for the separation of moderately and highly polar compounds. Various stationary phases (SPs) for hydrophilic interaction liquid chromatography are commercially available. While the SPs based on the same type of ligand are available from different providers, they can display a distinct retention characteristics and separation selectivity. The current work is focused on characterization and comparison of the separation systems of two amide‐based HPLC columns from two producers, i.e. XBridge Amide column and TSK gel Amide‐80 column. Several characterization procedures (tests) were used to investigate the differences between these columns. The chromatographic behavior of selected analytes indicates that multimodal interactions are responsible for retention and separation on these columns. Multiple testing approaches were used in order to reveal subtle differences between the SPs. Both amide‐based columns showed certain differences in retention, selectivity, and plate counts. Based on the tests used in this study, we conclude that the investigated columns provide a different degree of H‐bonding interactions.  相似文献   

10.
A new on-line redox derivatization technique using double separation columns and one redox derivatization unit was presented for enhancement of separation selectivity of HPLC. This on-line redox derivatization HPLC system consisted of two separation columns and one redox derivatization unit placed between them. The redox reaction proceeds in the derivatization unit so that an analyte compound migrates as its original form in the first column, while as its oxidized or reduced form in the second column. The retention of the analytes is controlled by the lengths of the two separation columns in this system. We adopted a small column packed with porous graphitic carbon (PGC) as a redox derivatization unit and two C18 silica columns treated with hexadecyltrimethylammonium chloride as separation columns. The redox activity of PGC and the efficiency of the on-line redox derivatization HPLC system for enhancement of separation selectivity were investigated using EDTA complexes of some metal ions. Original untreated PGC and PGC treated with hydrogen peroxide completely oxidized Co(II)-EDTA and converted it to Co(III)-EDTA, while the other metal complexes eluted as their original oxidation states throughout the system. Selective separation and determination of cobalt in a reference copper alloy by the developed method were demonstrated.  相似文献   

11.
Metoprolol and a number of related amino alcohols and similar analytes have been chromatographed on aminopropyl (APS) and ethylpyridine (EPS) silica columns. The mobile phase was carbon dioxide with methanol as modifier and no amine additive was present. Optimal isocratic conditions for the selectivity were evaluated based on experiments using design of experiments. A central composite circumscribed model for each column was used. Factors were column temperature, back-pressure and % (v/v) of modifier. The responses were retention and selectivity versus metoprolol. The % of modifier mainly controlled the retention on both columns but pressure and temperature could also be important for optimizing the selectivity between the amino alcohols. The compounds could be divided into four and five groups on both columns, with respect to the selectivity. Furthermore, on the aminopropyl silica the analytes were more spread out whereas on the ethylpyridine silica, due to its aromaticity, retention and selectivity were closer. For optimal conditions the column temperature and back-pressure should be high and the modifier concentration low. A comparison of the selectivity using optimized conditions show a few switches of retention order between the two columns. On aminopropyl silica an aldehyde failed to be eluted owing to Schiff-base formation. Peak symmetry and column efficiency were briefly studied for some structurally close analogues. This revealed some activity from the columns that affected analytes that had less protected amino groups, a methyl group instead of isopropyl. The tailing was more marked with the ethylpyridine column even with the more bulky alkyl substituents. Plate number N was a better measure than the asymmetry factor since some analyte peaks broadened without serious deterioration of symmetry compared to homologues.  相似文献   

12.
Several reasons can exist for a change in reversed-phase selectivity, and several separation conditions can be changed for this purpose. In the present investigation, a change in column is considered for the improved separation of non-ionized solutes only. Differences in column selectivity (and the selection of "orthogonal" columns) can be predicted on the basis of the hydrophobic-subtraction model. For ionized solutes, the F(s)-parameter is used to predict orthogonality. For use with non-ionized solutes, it is suggested that the cation-exchange term of the model be dropped [F(s)(-C)] for better predictions. For samples containing both ionized and non-ionized solutes, F(s) and F(s)(-C) should be used together for the best results. Predicted separations involving 64 non-ionized solutes and maximally different columns from a 400-column database were used to validate this procedure.  相似文献   

13.
Two‐dimensional liquid chromatography largely increases the number of separated compounds in a single run, theoretically up to the product of the peaks separated in each dimension on the columns with different selectivities. On‐line coupling of a reversed‐phase column with an aqueous normal‐phase (hydrophilic interaction liquid chromatography) column yields orthogonal systems with high peak capacities. Fast on‐line two‐dimensional liquid chromatography needs a capillary or micro‐bore column providing low‐volume effluent fractions transferred to a short efficient second‐dimension column for separation at a high mobile phase flow rate. We prepared polymethacrylate zwitterionic monolithic micro‐columns in fused silica capillaries with structurally different dimethacrylate cross‐linkers. The columns provide dual retention mechanism (hydrophilic interaction and reversed‐phase). Setting the mobile phase composition allows adjusting the separation selectivity for various polar substance classes. Coupling on‐line an organic polymer monolithic capillary column in the first dimension with a short silica‐based monolithic column in the second dimension provides two‐dimensional liquid chromatography systems with high peak capacities. The silica monolithic C18 columns provide higher separation efficiency than the particle‐packed columns at the flow rates as high as 5 mL/min used in the second dimension. Decreasing the diameter of the silica monolithic columns allows using a higher flow rate at the maximum operation pressure and lower fraction volumes transferred from the first, hydrophilic interaction dimension, into the second, reversed‐phase mode, avoiding the mobile phase compatibility issues, improving the resolution, increasing the peak capacity, and the peak production rate.  相似文献   

14.
Eight commercially available sub-2 microm octadecyl silane columns (C18 columns) have been characterised by the Tanaka protocol. The columns can be grouped into two groups that display large differences in selectivity and peak shape due to differences in hydrophobicity, degree of surface coverage and silanol activity. Measurements of particle size distributions were made using automated microscopy and electrical sensing zone measurements. Only a weak correlation could be found between efficiency and particle size. Large differences in column backpressure were observed. These differences are not related to particle size distribution. A more likely explanation is differences in packing density. In order to take full advantage of 100-150 mm columns packed with sub-2 microm particles, it is often necessary to employ not only an elevated pressure but also an elevated temperature. A comparison between columns packed with sub-2, 3 and 5 microm versions of the same packing indicates potential method transferability problems for several of the columns due to selectivity differences. Currently, the best alternative for fast high-resolution LC is the use of sub-2 microm particles in combination with elevated pressure and temperature. However, as shown in this study additional efforts are needed to improve transferability as well as column performance.  相似文献   

15.
A comprehensive two-dimensional capillary supercritical fluid chromatography method was developed. The interface consisted of a ten-port valve, a capillary trap and two fused silica restrictors. The primary column was operated in stop-flow mode: the flow in the primary column was stopped during the separation of the second dimension. The pressure of the system was controlled with a single pump. The pressure program was synchronized with the sampling: the pressure was only ramped up during the sampling time, when the primary column effluent was transferred from the first dimension to the trap, and was maintained constant during the second-dimension separation. All of the operations were automated using in-house software. The separation characteristics of the present system can be readily regulated by changing the size of the restrictors and/or the programmed pressure rate. The use of synchronized pressure programming allowed the sampling duration and/or the second-dimension separation time (and therefore, the total analysis time) to be changed without affecting the separation pattern. Widely different selectivities were attained depending on the combination of the three columns with different polarities (such as the nonpolar DB-1, the medium-polarity DB-17 and the polar DB-WAX columns) used. The present system afforded improved separation and identification capabilities for analytes in complex mixtures.  相似文献   

16.
Methods to prepare fractions of poly(epsilon-caprolactone) with a narrow molecular mass distribution in large quantities have been examined using high osmotic pressure chromatography under the theta condition. Effects of column dimension and coupling columns in series on the separation resolution were studied. We found that use of a thicker column can improve the resolution if adverse effects of viscous fingering are avoided. We also demonstrated that coupling the columns results in a better separation if the second column does not adsorb high-molecular-mass components purified in the first column.  相似文献   

17.
18.
In the current study, an HPLC-FID system using superheated water as the eluent is constructed and further improved. Signal stability during temperature programmed operation was improved by using separate thermostatting of the 50 μm capillary restrictor. Operating the restrictor at 75°C prevented the superheated water from sputtering in the restrictor. Conventional octadecyl-modified silica, thermostable polymeric reversed phase and carbon type HPLC columns were used. The feasibility of the system is demonstrated by the analysis of a variety of compounds such as alcohols and aldehydes. It is shown that increased temperatures decrease elution times and, in addition to this, frequently improve peak shapes and column efficiencies. The separation of lower aldehydes is performed at 175°C with a detection limit in the low μg/ml range. The possibility of temperature programming is demonstrated for the separation of a range of alcohols. Furthermore, it is shown that temperature programming can be used for sample enrichment. Large volume injection with low temperature enrichment resulted in good peak shapes and a significant improvement of the detection limit. In this way, detection limits of 0.2 μg/ml (ppm) could be obtained for the aldehydes studied. Finally, the possibilities of using mobile phase additives as, e.g., buffers were briefly examined.  相似文献   

19.
A versatile system with a slurry-packed capillary column was developed for supercritical fluid chromatography, which is capable of programming both inlet and outlet pressure independently, as well as using a restrictor to apply back pressure. This system revealed the relationships between pressure drop, flow rate, and linear velocity in pressure-programmed supercritical fluid chromatography. In the restrictor system, both the pressure drop and the flow rate increased almost linearly with inlet pressure, while under conditions of constant pressure drop characteristic behavior was observed which depended on the density-viscosity relationships of supercritical fluid. Resolution in the separation of polysiloxane oligomers was found to be increased by increasing the ratio of pressure drop to pressure-programming rate, although the sensitivity decreased due to the increase in peak volume. The system controlling both inlet and outlet pressure has distinct advantages over the restrictor system controlling both inlet and outlet pressure has distinct advantages over the restrictor system in practical in practical operations.  相似文献   

20.
A comprehensive 2-D-LC-MS method has been developed by coupling columns of different selectivity. The primary column eluate is alternately trapped and sampled onto the secondary columns through a guard column interface. When one guard column traps the eluate, the other injects the previously trapped components onto a secondary column. This cycle is repeated throughout the chromatogram. The use of dual secondary columns provides the secondary columns with additional time to generate high-speed chromatograms. Each secondary column generates alternate chromatograms which when combined generate the entire chromatogram. The primary column separation is comparable to conventional HPLC, whereas the secondary column separation is fast. With both the columns operating in reverse phase mode, one would expect strong correlation in the two-dimensional retention and hence inefficiency in separation. However, differences in column operation modes, interaction mechanisms, and vendor silica result in a complementary separation. The system was evaluated by comparing it to one-dimensional counterparts and coupled column chromatography. Although some correlations were observed in 2-D-LC-MS, peaks do show two-dimensional distribution with superior UV and MS data as co-elution is minimized. Also, the ease of converting conventional systems to 2-D-LC-MS is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号