首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Baena B  Cifuentes A  Barbas C 《Electrophoresis》2005,26(13):2622-2636
This review article addresses the different capillary electrophoretic methods that are being used for the study of both short-chain organic acids (including anionic catecholamine metabolites) and fatty acids in biological samples. This work intends to provide an updated overview (including works published until November 2004) on the recent methodological developments and applications of such procedures together with their main advantages and drawbacks. Moreover, the usefulness of CE analysis of organic acids to study and/or monitor different diseases such as diabetes, new-borns diseases or metabolism disorders is examined. The use of microchip devices and CE-MS couplings for organic acid analysis is also discussed.  相似文献   

2.
Capillary electrophoretic analysis of individual submicrometer size particles has been previously done using custom-built instruments. Despite that these instruments provide an excellent signal-to-noise ratio for individual particle detection, they are not capable of performing automated analyses of particles. Here we report the use of a commercial Beckman P/ACE MDQ capillary electrophoresis (CE) instrument with on-column laser-induced fluorescence (LIF) detection for the automated analysis of individual particles. The CE instrument was modified with an external I/O board that allowed for faster data acquisition rates (e.g. 100 Hz) than those available with the standard instrument settings (e.g. 4 Hz). A series of eight hydrodynamic injections expected to contain 32 +/- 6 particles, each followed by an electrophoretic separation at -300 V cm(-1) with data acquired at 100 Hz, showed 28 +/- 5 peaks corresponding to 31.9 particles as predicted by the statistical overlap theory. In contrast, a similar series of hydrodynamic injections followed by data acquisition at 4 Hz revealed only 8 +/- 3 peaks suggesting that the modified system is needed for individual particle analysis. Comparison of electropherograms obtained at both data acquisition rates also indicate: (i) similar migration time ranges; (ii) lower variation in the fluorescence intensity of individual peaks for 100 Hz; and (iii) a better signal-to-noise ratio for 4 Hz raw data. S/N improved for 100 Hz when data were smoothed with a binomial filter but did not reach the S/N values previously reported for post-column LIF detection. The proof-of-principle of automated analysis of individual particles using a commercially available CE system described here opens exciting possibilities for those interested in the study and analyses of organelles, liposomes, and nanoparticles.  相似文献   

3.
In the perspective of in-field stripping analysis of heavy metals, the use and disposal of toxic mercury solutions (necessary to plate a mercury film on a carbon electrode surface) presents a problem. The aim of this work was the development of mercury coated screen-printed electrodes previously prepared in the lab and ready to use in-field. Thus some commercially available polymers like Nafion®, Eastman Kodak AQ29®, and Methocel® were investigated as mercury entrapping systems for electrochemical stripping analysis of heavy metals. Screen-printed disposable cells with a silver pseudo-reference electrode, a graphite counter electrode, and a graphite working electrode were used. To modify the sensor, the polymer solution was cast onto the carbon working electrode surface. Detection limits of 0.8 and 1 μg/L were obtained for lead and cadmium respectively. Since Methocel® based electrodes showed the best performance, they were used for the analysis of real samples. The results were compared with those obtained using a classical thin mercury film electrode and ICP spectroscopy.

All the experiments reported here were performed in un-deareated solutions as required for in-field analysis.  相似文献   

4.
A novel design of the detection zone in multicapillary arrays used for electrophoretic separation is presented. The use of a detection gap (DG), in which the reflective surfaces separating the channels of the array are eliminated, is proposed to improve the illumination and detection of the separated DNA fragments. The electric field compression in the DG is achieved by optimization of the gap geometry. The results of the computer simulation and experiment demonstrate no substantial band-broadening in the DG. We believe that the proposed method will be useful for application in the microfabricated devices.  相似文献   

5.
This article describes a novel microchip-based capillary electrophoresis and oncolumn enzymatic reaction analysis protocol for lactate dehydrogenase (LDH) isoenzymes with a home-made xenon lamp-induced fluorescence detection system. A microchip integrated with a temperature-control unit is designed and fabricated for low-temperature electrophoretic separation of LDH isoenzymes, optimal enzyme reaction temperature control, and product detection. A four-step operation and temperature control are employed for the determination of LDH activity by on-chip monitoring of the amount of incubation product of NADH during the fixed incubation period and at a fixed temperature. Experiments on the determination of LDH standard sample and serum LDH isoenzymes from a healthy adult donor are carried out. The results are comparable with those obtained by conventional CE. Shorter analysis times and a more stable and lower background baseline can be achieved. The efficient separation of different LDH forms indicates the potential of microfluidic devices for isoenzyme assay.  相似文献   

6.
A number of significant improvements in the electrophoretic performance and design of DNA sequencing devices have culminated in the introduction of truly industrial grade production scale instruments. These instruments have been the workhorses behind the massive increase in genomic sequencing data available in public and private databases. We highlight the recent progress in aspects of capillary electrophoresis (CE) that has enabled these achievements. In addition, we summarize recent developments in the use of microfabricated devices for DNA sequencing that promise to bring the next leap in productivity.  相似文献   

7.
高效毛细管电泳-电荷耦合器件检测器联用技术研究(Ⅶ)──低聚肽及其降解产物的分离熊少祥,李建军,程介克(武汉大学化学系,武汉,430072)关键词毛细管电泳.电荷耦合器件检测器.荧光检测.联用技术多肽及其降解产物氨基酸是组成生命物质蛋白质的基础,某些...  相似文献   

8.
The use of organic solvents as electrolytic medium in electrophoresis has become an important alternative for the analysis of compounds that exhibit low or no solubility in water. In recent years, nonaqueous electrophoresis has been extensively explored in conventional capillary systems for different applications. On the other hand, this separation strategy is still not as popular as free solution electrophoresis on chip-based platforms due to the effects of solvent in the background electrolyte on the sample injection, detection performance, and microfluidic platform compatibility. In this way, this review summarizes the main achievements on nonaqueous microchip electrophoresis (NAME). To the best of our knowledge, this is the first review dedicated to discuss exclusively nonaqueous electrophoresis on chip-based systems. For this purpose, some important theoretical aspects involved when separations are performed in organic medium, such as equilibrium, interactions and electrophoretic considerations, are included in the review. In addition, the main challenges, advantages and influences of nonaqueous media on the sample injection, detection as well as the choice of the substrate to fabricate chip-based electrophoresis devices are highlighted. Last, examples showing the feasibility of nonaqueous microchip electrophoresis for applications exploiting different methodologies, operational, and instrumental conditions are summarized and discussed. We hope this review can be useful to spread the huge potential of nonaqueous electrophoresis on microfluidic platforms.  相似文献   

9.
Seaman GV  Knox RJ 《Electrophoresis》2001,22(3):373-385
Process control is an increasingly important issue as life science companies world-wide strive for recognition of their manufacturing and product development quality measures according to International Standards Organization (ISO) or good manufacturing practices (GMP) standards. Analytical particle electrophoresis (APE) has the potential for significant contributions, not just to basic research, but also in process development and control in manufacturing environments. An important feature of colloidal (small) particles, which controls their behavior, is their surface charge. Optimization of life science products and process conditions involving small particles (>100 nm) may be approached by a variety of strategies based upon direct measurements of the charge properties of process particles or "reporter" particles. The availability of increasingly powerful instruments and control particle preparations (National Institute of Standards and Technology ((NIST) and others) for validation of instrument operation make the method more attractive than ever. We summarize highly flexible electrophoretic strategies for assessing process consistency both from the perspective of particles being processed as well as the processing environment and describe principles for the use of polymer microspheres both as control particles for validation of instrument operation as well as for probes of the assay medium.  相似文献   

10.
We present the design and characterization of a low cost, thread-based electrophoretic device with integrated electrochemical detection. The device has an end-channel pencil graphite electrode placement system for performing electrochemical detection on the thread electrophoresis platform with direct sample pipetting onto the thread. We also established the use of methylene blue and neutral red as a pair of reference migration markers for separation techniques coupled with electrochemical detection, as they have different colors for visual analysis and are both electroactive. Importantly, neutral red was also found to migrate at a similar rate to the EOF, indicating that it can be used as a visual identifier of EOF. The utility of our system was demonstrated by electrophoretic separation and electrochemical detection of physiologically relevant concentrations of pyocyanin in a solution containing multiple electroactive compounds. Pyocyanin is a biomarker for the detection of pathogenic Pseudomonas aeruginosa and has a redox potential that is similar to that of methylene blue. The system was able to effectively resolve methylene blue, neutral red, and pyocyanin in less than 7 min of electrophoretic separation. The theoretical limit of detection for pyocyanin was determined to be 559 nM. The electrophoretic mobilities of methylene blue (0.0236 ± 0.0007 mm2/V·s), neutral red (0.0149 ± 0.0007 mm2/V·s), and pyocyanin (0.0107 ± 0.0003 mm2/V·s) were also determined.  相似文献   

11.
We review recent developments in manifold components and the introduction of light-emitting-diode technology in spectroscopic detection in order to evaluate the tremendous possibilities offered by multi-commutation for in-field and in-situ measurements, based on the use of multi-pumping and low-voltage, portable batteries, which make possible a dramatic reduction in size, weight and power requirements of spectrometric devices.  相似文献   

12.
Pascoe RJ  Foley JP 《Electrophoresis》2003,24(24):4227-4240
The physical, electrophoretic and chromatographic properties (mean diameter, electroosmotic flow, electrophoretic mobility, elution range, efficiency, retention, and hydrophobic, shape, and chemical selectivity) of three surfactant vesicles and one phospholipid vesicle were investigated and compared to a conventional micellar pseudostationary phase comprised of sodium dodecyl sulfate (SDS). Chemical selectivity (solute-pseudostationary phase interactions) was discussed from the perspective of linear solvation energy relationship (LSER) analysis. Two of the surfactant vesicles were formulated from nonstoichiometric aqueous mixtures of oppositely charged, single-tailed surfactants, either cetyltrimethylammonium bromide (CTAB) and sodium octyl sulfate (SOS) in a 3:7 mole ratio or octyltrimethylammonium bromide (OTAB) and SDS in a 7:3 mole ratio. The remaining surfactant vesicle was comprised solely of bis(2-ethylhexyl)sodium sulfosuccinate (AOT) in 10% v/v methanol, and the phospholipid vesicle consisted of 1-palmitoyl-2-oleyl-sn-glycero-3-phosphocholine (POPC) and phosphatidyl serine (PS) in 8:2 mole ratio. The mean diameters of the vesicles were 76.3 nm (AOT), 86.9 nm (CTAB/SOS), 90.1 nm (OTAB/SDS), and 108 nm (POPC/PS). Whereas the coefficient of electroosmotic flow (10(-4) cm2 V(-1) s(-1)) varied considerably (1.72 (OTAB/SDS), 3.77 (CTAB/SOS), 4.05 (AOT), 5.26 (POPC/PS), 5.31 (SDS)), the electrophoretic mobility was fairly consistent (-3.33 to -3.87 x 10(-4) cm2 V(-1) s(-1)), except for the OTAB/SDS vesicles (-1.68). This resulted in elution ranges that were slightly to significantly larger than that observed for SDS (3.12): 3.85 (POPC/PS), 8.6 (CTAB/SOS), 10.1 (AOT), 15.2 (OTAB/SDS). Significant differences were also noted in the efficiency (using propiophenone) and hydrophobic selectivity; the plate counts were lower with the OTAB/SDS and POPC/PS vesicles than the other pseudostationary phases (< or = 75,000/m vs. > 105,000/m), and the methylene selectivity was considerably higher with the CTAB/SOS and OTAB/SDS vesicles compared to the others (ca. 3.10 vs. < or = 2.6). In terms of shape selectivity, only the CTAB/SOS vesicles were able to separate all three positional isomers of nitrotoluene with near-baseline resolution. Finally, through LSER analysis, it was determined that the cohesiveness and hydrogen bond acidity of these pseudostationary phases have the greatest effect on solute retention and selectivity.  相似文献   

13.
Amperometric and conductometric detection are currently the two major electrochemical detection modes in capillary and chip electrophoresis. The ease of miniaturization and integration of electrochemical detection elements offers a high potential for the development of portable analytical devices based on electromigrative separations. The challenges and basic concepts of both detection principles in the context of capillary/chip electrophoresis are shortly introduced and milestones of the methodical developments are summarized from a historical perspective. Recent advances and applications are discussed with more detail. Particular attention is paid to new trends in this area of research such as measurements in short capillaries and the enormous progress and increased popularity of contactless conductivity detection. Correspondence: Frank-Michael Matysik, Institute of Analytical Chemistry, University of Leipzig, Linnéstr. 3, D-04103 Leipzig, Germany  相似文献   

14.
《Electrophoresis》2018,39(11):1399-1409
The precursor compounds related to the bitterness of beer are called α‐acids. These compounds are extracted from the hop, which is an important ingredient in the brewing process. These compounds were analyzed by capillary electrophoresis. The electrophoretic method used 160 mmol/L of ammonium carbonate (pH 9) as BGE (background electrolyte), a voltage of +20 kV in a capillary with 50 μm of internal diameter and with a 62.5 cm of total length (54 cm effective). The samples were injected in hydrodynamic mode applying a pressure of 25 mbar for 5 s and the analytes were detected at 230 nm. A hydromethanolic extraction during 3 h was considered as the optimum condition for the sample preparation using MeOH/H2O 80:20 v/v as the extract solution. From the optimized conditions the electropherograms were evaluated for their use as input for chemometric modeling. Preprocessing investigation for electrophoretic data taking into account the alignment, denoising and baseline correction, and variable selection were considered before the chemometric modeling using principal component analysis (PCA). The electrophoretic data were systematically evaluated to find the optimum conditions to modeling. A PCA analysis for all tests was carried out using different preprocessing methods and, an explained variance higher than 90% was achieved in all of them. The optimized chemometric method worked with aligned and meancentered data. From this approach, a simple and efficient method to classify hop samples with high and low α‐acids content without the use of analytical standards was established from a simple electrophoretic analysis.  相似文献   

15.
To comply with the current needs for high-speed DNA sequencing analysis, several instruments and innovative technologies have been introduced by several groups in recent years. This review article discusses and compares the issues regarding high-throughput DNA sequencing by electrophoretic methods in miniaturized systems, such as capillaries, capillary arrays, and microchannels. Initially, general features of several capillary array designs (including commercial ones) will be considered, followed by similar analyses with microfabricated array electrophoretic devices and how they can contribute to the success of large sequencing projects.  相似文献   

16.
Recently the use electric field gradient focusing (EFGF) to enhance focusing of proteins has been proposed and explored to provide significant improvement in separation resolution. The objective of EFGF is to focus proteins of specific electrophoretic mobilities at distinct stationary locations in a column or channel. This can be accomplished in a capillary by allowing the electric potential to vary in the streamwise direction. Because the electric field is varying, so also is the electrokinetic force exerted on the proteins and the electroosmotic velocity of the buffer solution. Due to the varying electric field, the Taylor diffusion characteristics will also vary along the column, causing a degradation of peak widths of some proteins, dependent on their equilibrium positions and local velocity distributions. The focus of this paper is an analysis that allows characterization of the local Taylor diffusion and resulting protein band peak width as a function of the local magnitude of the EOF relative to the average fluid velocity for both cylindrical and rectangular channels. In general the analysis shows that as the ratio of the local electroosmotic velocity to the average velocity deviates from unity, the effective diffusion increases significantly. The effectiveness of EFGF devices over a range of protein diffusivities, capillary diameters, flow velocities, and electric field gradient is discussed.  相似文献   

17.
It is commonly accepted that the modern CE instruments equipped with efficient cooling system enable accurate determination of electrophoretic or electroosmotic mobilities. It is also often assumed that velocity of migration in a given buffer is constant throughout the capillary length. It is simultaneously neglected that the noncooled parts of capillary produce extensive Joule heating leading to an axial electric field distortion, which contributes to a difference between the effective and nominal electric field potentials and between velocities in the cooled and noncooled parts of capillary. This simplification introduces systematic errors, which so far were however not investigated experimentally. There was also no method proposed for their elimination. We show a simple and fast method allowing for estimation and elimination of these errors that is based on combination of a long‐end and short‐end injections. We use it to study the effects caused by variation of temperature, electric field, capillary length, and pH.  相似文献   

18.
合成纳米颗粒常在尺寸和形状方面具有广泛分布.在很多实验中,需要利用一定大小及形状的纳米颗粒的独特物理化学性质,因此,简便快速的纳米颗粒分离技术越来越受到诸多科学领域的重视.电泳技术以其高分辨率,被广泛用于多种生物大分子如核酸、蛋白质等的分离纯化.纳米颗粒在尺寸上与生物体中的蛋白复合物、细胞器和微生物等十分接近,考虑到带电纳米颗粒与生物分子在电场中的运动行为的相似性,运用电泳技术进行纳米颗粒的鉴定、分离和纯化是一种新的思路,并取得了良好的实验结果.本文主要介绍了琼脂糖凝胶电泳、毛细管电泳以及其他一些电泳技术在纳米颗粒分离中的研究进展.  相似文献   

19.
Summary Minimum capillary lengths on commercial instruments are fixed and cannot be decreased further. To effectively reduce the capillary length used for separation the sample can be injected from the end of the capillary nearest the detector. This procedure is known as a short-end injection and can reduces analysis times by at least two-thirds compared to conventional injections. The time reduction benefits are shown in rapid separations of basic drugs, drug-related impurities and chiral compounds. Short-end injections, in combination with both increased electrolyte strength and reduced voltage are an effective approach to reducing the detrimental impact of high sample solution ionic strength. They can also lead to improved resolution by increasing stacking effects and reducing peak tailing. Peak area and migration time precision obtained are shown to be equivalent to those obtained for conventional injection procedures. It is concluded that short-end injections should be considered for routine operation as they are a useful means of reducing analysis time, increasing sensitivity, decreasing buffer depletion effects. They also allow use of higher electrolyte strengths which can improve resolution and reduce peak tailing, and can overcome significant problems which occur when analysing samples containing high salt contents.  相似文献   

20.
Preparation of affinity polyacrylamide gels containing immobilized Fe(III) ions for the separation of proteins exhibiting metal ion binding properties is described. The presented method enables uniform distribution of immobilized metal ions in the affinity part of the polyacrylamide separating gel. Affinity gels prepared by this way are suitable to follow the effect of different concentrations of metal ions immobilized in polyacrylamide gel on a protein electrophoretic behavior. Polyacrylamide gels containing immobilized Fe(III) ions were used to study the electrophoretic behavior of two model proteins differing in their phosphate group content: chicken ovalbumin and bovine α‐casein. For the electrophoretic separation, both the native and the denaturating conditions were used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏