 共查询到20条相似文献,搜索用时 93 毫秒
1.
Flow cytometry (FCM) and more recently capillary electrophoresis with post-column laser-induced fluorescence detection (CE-LIF) have both been used for subcellular particle analysis but their analytical performance has not been compared. In this work, we compare a commercial FCM with an in-house built CE-LIF instrument using fluorescently labeled microspheres and isolated mitochondria. As evidenced by the relative standard deviation (RSD) of the individual fluorescence intensities, FCM is two-fold better than CE-LIF for microspheres with > or =1.5 x 10(6) molecules of equivalent soluble fluorescein (MESF). However, FCM has a comparatively low signal-to-noise ratio (S/N) and high RSD for microspheres with <1.5 x 10(6) MESF. CE-LIF, on the other hand, produces S/N ratios that are >25 times higher than FCM for all the microspheres tested and a lower RSD for microspheres with <1.5 x 10(6) MESF. When 10-N-nonyl acridine orange (NAO)-labeled mitochondria are analyzed, the S/N ratios of both techniques are similar. This appears to result from photobleaching of NAO-labeled mitochondria as they are detected by the LIF detector of the CE-LIF instrument. Both techniques have a niche in subcellular analysis; FCM has the advantage of collecting data for thousands of particles quickly, whereas CE-LIF consumes less than a nanoliter of sample and provides the electrophoretic mobility for individual particles.  相似文献   

2.
This report investigates the effects of sample size on the separation and analysis of individual biological particles using microfluidic devices equipped with an orthogonal LIF detector. A detection limit of 17 +/- 1 molecules of fluorophore is obtained using this orthogonal LIF detector under a constant flow of fluorescein, which is a significant improvement over epifluorescence, the most common LIF detection scheme used with microfluidic devices. Mitochondria from rat liver tissue and cultured 143B osteosarcoma cells are used as model biological particles. Quantile-quantile (q-q) plots were used to investigate changes in the distributions. When the number of detected mitochondrial events became too large (>72 for rat liver and >98 for 143B mitochondria), oversampling occurs. Statistical overlap theory is used to suggest that the cause of oversampling is that separation power of the microfluidic device presented is not enough to adequately separate large numbers of individual mitochondrial events. Fortunately, q-q plots make it possible to identify and exclude these distributions from data analysis. Additionally, when the number of detected events became too small (<55 for rat liver and <81 for 143B mitochondria) there were not enough events to obtain a statistically relevant mobility distribution, but these distributions can be combined to obtain a statistically relevant electrophoretic mobility distribution.  相似文献   

3.
A laser-induced fluorescence (LIF) immunoassay technique based on capillary electrophoretic (CE) separation is demonstrated. The analysis of digoxin in serum at clinically useful concentration levels of 10−9 to 10−10 M is achieved using this technique. The chemistry presented here using digoxigenin-labeled B-phycoerythrin was selected as a convenient model for the exploration of CE-LIF-based immunoassays. The LIF system described here exhibits detection limits in the low 10−11 M range for several common fluorophores. The data presented in this report are one of the first examples of nanomolar quantitative analysis in a human serum matrix by CE.  相似文献   

4.
Kuo IT  Huang YF  Chang HT 《Electrophoresis》2005,26(13):2643-2651
This paper describes the analysis of biologically active amines by capillary electrophoresis (CE) in conjunction with laser-induced native fluorescence detection. In order to simultaneously analyze amines and acids as well as to achieve high sensitivity, 10 mM formic acid solutions (pH < 4.0) containing silica nanoparticles (SiNPs) were chosen as the background electrolytes. With increasing SiNP concentration, the migration times for seven analytes decrease as a result of increase in electroosmotic flow (EOF) and decrease in their electrophoretic mobilities against EOF. A small EOF generated at pH 3.0 reveals adsorption of SiNPs on the deactivated capillary wall. The decreases in electrophoretic mobilities with increasing SiNP concentration up to 0.3x indicate the interactions between the analytes and the SiNPs. Having a great sensitivity (the limits of detection at a signal-to-noise ratio (S/N) = 3 of 0.09 nM for tryptamine (TA)), high efficiency, and excellent reproducibility (less than 2.4% of the migration times), this developed method has been applied to the analysis of urinal samples with the concentrations of 0.50 +/- 0.02 microM, 0.49 +/- 0.04 microM, and 74 +/- 2 microM for TA, 5-hydroxytryptamine, and tryptophan, respectively. The successful examples demonstrated in this study open up a possibility of using functional nanoparticles for the separation of different analytes by CE.  相似文献   

5.
Capillary electrophoresis with Laser-Induced Fluorescence (CE-LIF) detection is being applied to new analytical problems which challenge both the power of CE separation and the sensitivity of LIF detection. On-capillary LIF detection is much more practical than post-capillary detection in a sheath-flow cell. Therefore, commercial CE instruments utilize solely on-capillary CE-LIF detection with a Limit of Detection (LOD) in the nM range, while there are multiple applications of CE-LIF that require pM or lower LODs. This tutorial analyzes all aspects of on-capillary LIF detection in CE in an attempt to identify means for improving LOD of CE-LIF with on-capillary detection. We consider principles of signal enhancement and noise reduction, as well as relevant areas of fluorophore photochemistry and fluorescent microscopy.  相似文献   

6.
In this study, in‐column fiber‐optic (ICFO) laser‐induced fluorescence (LIF) detection technique is coupled with capillary electrophoresis (CE) for the rapid separation of neodymium for the first time. The effects of buffer concentration, buffer pH, and separation voltage on the CE behaviors, including electrophoretic efficiency and detection sensitivity, are investigated in detail. Under the optimal condition determined in this study (15 mM borate buffer, pH 10.50, separation voltage 24 kV), neodymium could be separated effectively from the neighboring lanthanides (praseodymium and samarium) within several minutes, and the limit of detection for neodymium is estimated to be at the ppt level. The ICFO‐LIF‐CE system assembled in this study exhibits unique performance characteristics such as low cost and flexibility. Meanwhile, the separation efficiency and detection sensitivity of the assembled CE system are comparable to or somewhat better than those obtained in the previous traditional CE systems, indicating the potential of the assembled CE system for practical applications in the fields of spent nuclear fuel analysis, nuclear waste disposal/treatment, and nuclear forensics.  相似文献   

7.
DNA adducts are regarded as individual internal dosimeters for the exposure to chemical carcinogens. To date, the most sensitive method for DNA adduct analysis is the radioactive 32P-postlabeling method, which allows the detection of one adduct in 10(10) unmodified nucleotides in microg amounts of DNA. However, this technique suffers from disadvantages such as working with radioactive phosphorus and time-consuming chromatographic separation procedures. In addition, the simultaneous detection of adducts from different classes of carcinogens in a DNA sample is difficult. In order to overcome these drawbacks, we are developing a new detection method, comprising fluorescence labeling of DNA adducts, capillary electrophoretic (CE) separation, and on-line detection by monitoring laser-induced fluorescence (LIF). So far, we have evaluated the separation power and the detection limit of CE with fluorescently labeled standard compounds such as unmodified nucleotides or alkylated thymidines. For this purpose, we developed a universal method for labeling 5'-OH-mononucleosid-3'-dicyanoethyl-phosphates with fluorescent dyes based on the phosphoramidite technology for DNA synthesis. The separation of N3-methylated, N3-, O2- and O4-butylated thymidines from the unmodified nucleotide within a few minutes recommends CE-LIF as a powerful method for DNA adduct analysis.  相似文献   

8.
A capillary electrophoretic (CE) method was developed for the simultaneous determination of P(V) and As(V). A Mo(VI)-ascorbic acid reagent reacted with a mixture of trace amounts of P(V) and As(V) to form the corresponding heteropoly-blue complexes in 0.05 M acetate buffer (pH 3.5). When 0.05 M malonate buffer was used as a migration buffer, the peaks due to their migrations were well separated in the electropherogram, and the pre-column complex-formation reaction was applied to the simultaneous CE determination of P(V) and As(V) with direct UV detection at 220 nm. With the proposed method, the calibration curves were linear in the concentration range of 5 x 10(-7) - 1 x 10(-4) M, with a detection limit of 1 x 10(-7) M (a signal-to-noise ratio of 3). Interference from foreign ions was also discussed.  相似文献   

9.
Liu X  Liu X  Liang A  Shen Z  Zhang Y  Dai Z  Xiong B  Lin B 《Electrophoresis》2006,27(15):3125-3128
We developed a microfluidic chip-affinity CE method based on indirect LIF detection to study protein-drug interactions. The interaction between heparin and BSA was quantitatively studied, as a model system. In our method, sodium fluorescein was chosen as background, and redistilled water as marker to monitor EOF. The electrophoretic mobility changes of BSA were measured, with various concentrations of heparin added to the running buffer. Each run was completed within 80 s. The binding constant was determined to be (1.24 +/- 0.05) x 10(3) M(-1), which was in good agreement with that reported in the literature.  相似文献   

10.
1-Anilinonaphthalene-8-sulfonic acid (1,8-ANS), 4,4'-dianilino-1,1'-binaphthyl-5,5'-disulfonic acid (bis-ANS) and 2-(p-toluidino)naphthalene-6-sulfonic acid (2,6-TNS) were evaluated as additives in different buffers for the detection of bovine whey proteins using laser-induced fluorescence (LIF) monitoring in capillary electrophoresis (CE). These N-arylaminonaphthalene sulfonates furnish a large fluorescence emission when associated to some proteins whereas their emission in aqueous buffers, such as those used in CE separations, is very small. To select the best detection conditions, the fluorescence of these probes was first compared using experiments carried out in a fluorescence spectrophotometer. Using bovine serum albumin (BSA) as a model protein, it was demonstrated that 2-(N-cyclohexylamino)ethanesulfonic acid (CHES) buffer (pH 8 and pH 10.2) and the fluorescent probe 2,6-TNS gave rise to the highest increase in fluorescence for BSA. When the composition of these separation buffers was optimized for the electrophoretic separations, CHES buffer, pH 10.2 was chosen as the most suitable buffer to detect bovine whey proteins. The limit of detection obtained for some whey proteins in CE separations was about 6.10(-8) M for BSA, 3.10(-7) M for beta-lactoglobulin A (beta-LGA), 3.10(-7) M for beta-lactoglobulin B (beta-LGB), and 3.10(-6) M for alpha-lactalbumin (alpha-LA). These detection limits were compared to those achieved using UV detection under the same separation conditions. The results showed that the detection limits of BSA, beta-LGA and beta-LGB were twice as good using LIF than with UV detection. However, the limit of detection for alpha-LA was better when UV was used. The applicability of LIF detection to CE separation of whey proteins in bovine milk samples was also demonstrated.  相似文献   

11.
Alnajjar A  Butcher JA  McCord B 《Electrophoresis》2004,25(10-11):1592-1600
Methods for separation and determination of multiple drugs of abuse in biological fluids using capillary electrophoresis (CE) with native fluorescence and laser-induced fluorescence (LIF) detection are described herein. Using native fluorescence, normorphine, morphine, 6-acetyl morphine (6-AM), and codeine were analyzed by CE without any derivatization procedure and detected at an excitation wavelength of 245 nm with a cut-off emission filter of 320 nm, providing a rapid and simple analysis. The detection limits were in the range of 200 ng/mL. For a highly sensitive analysis, LIF detection was also examined using a two-step precolumn derivatization procedure. In this case, drugs extracted from human urine were first subjected to an N-demethylation reaction involving the use of 1-chloroethyl chloroformate (ACE-Cl) and then derivatized using fluorescein isothiocyanate isomer I (FITC) and analyzed by CE coupled to a LIF detector. Variables affecting this derivatization: yield of demethylation reaction, FITC concentration, reaction time and temperature, were studied. The estimated instrumental detection limits of the FITC derivatives were in the range of 50-100 pg/mL, using LIF detection with excitation and emission wavelengths of 488 nm and 520 nm, respectively. The linearity, reproducibility and reliability of the methods were evaluated. In addition, a comparison of the characteristics for both native fluorescence and LIF detections was also discussed.  相似文献   

12.
《Electrophoresis》2017,38(3-4):507-512
LIF detection often requires labeling of analytes with fluorophores; and fast fluorescent derivatization is valuable for high‐throughput analysis with flow‐gated CE. Here, we report a fast fluorescein‐labeling scheme for amino acid neurotransmitters, which were then rapidly separated and detected in flow‐gated CE. This scheme was based on the reaction between primary amines and o‐phthalaldehyde in the presence of a fluorescent thiol, 2‐((5‐fluoresceinyl)aminocarbonyl)ethyl mercaptan (FACE‐SH). The short reaction time (<30 s) was suited for on‐line mixing and derivatization that was directly coupled with flow‐gated CE for rapid electrophoretic separation and sensitive LIF detection. To maintain the effective concentration of reactive FACE‐SH, Tris(2‐carboxyethyl)phosphine was added to the derivatization reagents to prevent thiol loss due to oxidation. This labeling scheme was applied to the detection of neurotransmitters by coupling in vitro microdialysis with online derivatization and flow‐gated CE. It is also anticipated that this fluorophore tagging scheme would be valuable for on‐chip labeling of proteins retained on support in SPE.  相似文献   

13.
During the last decade, capillary electrophoresis (CE) has emerged as an important alternative to traditional analysis of serum and plasma proteins by agarose or celluloseacetate electrophoresis. CE analysis of plasma proteins can now be fully automated and also includes bar-code identification of samples, preseparation steps, and direct post-separation quantitation of individual peaks, which permits short assay times and high throughput. For laboratory work, it is important to have reference values from healthy individuals. Therefore, plasma samples from 156 healthy blood donors (79 females and 77 males) have been analyzed with the Capillarys instrument and the new high resolution buffer, which yields higher resolution than the beta1-beta2+ buffer. Albumin concentrations in samples are measured using nephelometry in order to assign protein concentrations to each peak. The 2.5 and 97.5 percentiles for both the percentages of different peaks and the protein concentrations in the peaks are calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. The Capillarys instrument is a reliable system for plasma protein analysis, combining advantages of full automation with high analytical performances and throughput.  相似文献   

14.
This study describes the development of a CE method for the analysis of the antihypertensive drug captopril using LIF detection. The method is based on the derivatization of captopril with the fluorescent label 5-iodoacetamidofluorescein. The optimization of the electrophoretic electrolyte composition together with other variables, such as applied voltage and injection time, resulted in a solution of 20 mM phosphate buffer adjusted to pH 12.0. The calibration curve for the fluorescent captopril derivative was linear in the concentration range 3.5-6000 ng/mL with a detection limit of 0.5 ng/mL. Intra- and interday precision (at a concentration of about 100 times the LOD) were less than 0.86 and 1.16%, respectively, both expressed as RSD. The assay was successfully used for quantification of captopril in some marketed pharmaceutical preparations and urine samples.  相似文献   

15.
A new, simple, and efficient approach for on-column surface-enhanced Raman scattering (SERS) detection in capillary electrophoresis (CE) is reported. A ∼50-μm SERS substrate spot was prepared by laser-induced growth of silver particles in the 100-μm inner diameter CE capillary window or in a flow cell consisting of a 250-μm inner diameter fused silica capillary connector. For this purpose, the Raman laser was focused by a 20× objective into the detection window filled with a 0.5 mM silver nitrate and 10 mM citrate buffer solution. During the CE runs, the silver substrate spot was formed in a few seconds after the analyte injection, hence the analytes adsorbed sequentially to the silver surface when the detection window was reached, followed by desorption from the silver surface and continuing the electrophoretic migration to the capillary end. Thus, beyond migration time, valuable molecular specific information was delivered by the SERS spectra. Accurate separations and high-intensity SERS spectra are shown by CE-SERS time-dependent 3D electropherograms for the analytes rhodamine 6G, 4-(2-pyridylazo)resorcinol (PAR), PAR complex with Cu(II) and methylene blue at 0.25–25 ppm concentrations, by using 1.4–3.6 mW HeNe laser power and an acquisition time of 5 s for each spectrum. Before and after each analyte passes the detection window, clean background spectra were recorded and no memory effects perturbed the SERS detection. The silver substrate is characterized by a fast preparation rate, good reproducibility, a preparation success rate of over 95% and no mentionable influence on the electrophoretic migration time, the CE-SERS and CE-UV electropherograms being in good agreement. The successful coupling of CE and on-column SERS detection opens new perspectives for monitoring CE separations.  相似文献   

16.
The use of secondary ion mass spectrometry (SIMS) for the detection and spatially resolved analysis of individual high explosive particles is described. A C(8) (-) carbon cluster primary ion beam was used in a commercial SIMS instrument to analyze samples of high explosives dispersed as particles on silicon substrates. In comparison with monatomic primary ion bombardment, the carbon cluster primary ion beam was found to greatly enhance characteristic secondary ion signals from the explosive compounds while causing minimal beam-induced degradation. The resistance of these compounds to degradation under ion bombardment allows explosive particles to be analyzed under high primary ion dose bombardment (dynamic SIMS) conditions, facilitating the rapid acquisition of spatially resolved molecular information. The use of cluster SIMS combined with computer control of the sample stage position allows for the automated identification and counting of explosive particle distributions on silicon surfaces. This will be useful for characterizing the efficiency of transfer of particulates in trace explosive detection portal collectors and/or swipes utilized for ion mobility spectrometry applications.  相似文献   

17.
A chip-based microfluidic system for high-throughput single-cell analysis is described. The system was integrated with continuous introduction of individual cells, rapid dynamic lysis, capillary electrophoretic (CE) separation and laser induced fluorescence (LIF) detection. A cross microfluidic chip with one sheath-flow channel located on each side of the sampling channel was designed. The labeled cells were hydrodynamically focused by sheath-flow streams and sequentially introduced into the cross section of the microchip under hydrostatic pressure generated by adjusting liquid levels in the reservoirs. Combined with the electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 33ms at the entry of the separation channel by Triton X-100 added in the sheath-flow solution. The maximum rate for introducing individual cells into the separation channel was about 150cells/min. The introduction of sheath-flow streams also significantly reduced the concentration of phosphate-buffered saline (PBS) injected into the separation channel along with single cells, thus reducing Joule heating during electrophoretic separation. The performance of this microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single erythrocytes. A throughput of 38cells/min was obtained. The proposed method is simple and robust for high-throughput single-cell analysis, allowing for analysis of cell population with considerable size to generate results with statistical significance.  相似文献   

18.
We report an ultrasensitive method for the analysis of glycosphingolipid catabolism. The substrate G(M1) and the set of seven metabolites into which it can be degraded (G(A1), G(M2), G(A2), G(M3), LacCer, GlcCer, and Cer) were labeled with the highly fluorescent dye tetramethylrhodamine. CE with LIF detection was used to assay these compounds with 150 +/- 80 yoctomole mass (1 ymol = 10(-24) mol = 0.6 copies) detection limits and 5 +/- 3 pM concentration detection limits. An alignment algorithm based on migration of two components was employed to correct for drift in the separation. The within-day and between-day precision in peak height was 20%, in peak width 15%, and in adjusted migration time 0.03%. After normalization to total sample injected, the RSD in peak height reduced to 2-6%, which approaches the limit set by molecular shot noise in the number of molecules taken for analysis. PC12 cells were incubated with the labeled G(M1). Fluorescent microscopy demonstrated uptake by the cells. CE was used to separate a cellular homogenate prepared from these cells. A set of peaks was observed, which were tentatively identified based on comigration with the standards. Roughly 120 pL of homogenate was injected, which contained a total of 150 zmol of labeled substrate and products. Metabolite that preserves the fluorescent label can be detected at the yoctomole level, which should allow characterization of this metabolic pathway in single cells.  相似文献   

19.
Gao J  Yin XF  Fang ZL 《Lab on a chip》2004,4(1):47-52
A microfluidic system was developed for the analysis of single biological cells, with functional integration of cell sampling, single cell loading, docking, lysing, and capillary electrophoretic (CE) separation with laser induced fluorescence (LIF) detection in microfabricated channels of a single glass chip. Channels were 12 microm deep and 48 microm wide, with a simple crossed-channel design. The effective separation channel length was 35 mm. During sampling with a cell suspension (cell population 1.2 x 10(5) cells per mL in physiological salt solution), differential hydrostatic pressure (created by adjusting liquid levels in the four reservoirs) was used to control cell flow exclusively through the channel crossing. Single cell loading into the separation channel was achieved by electrophoretic means by applying a set of potentials at the four reservoirs, counteracting the hydrostatic flow. A special docking (adhering) procedure for the loaded cell was applied before lysis by repeatedly connecting and disconnecting a set of low potentials, allowing precise positioning of the cell within the separation channel. Cell lysis was then effected within 40 ms under an applied CE separation voltage of 1.4 kV (280 V cm(-1)) within the working electrolyte (pH 9.2 borate buffer) without additional lysates. The docked lysing approach reduced dispersion of released intracellular constituents, and significantly improved the reproducibility of CE separations. Glutathione (GSH) was used as a model intracellular component in single human erythrocyte cells. NDA derivatized GSH was detected using LIF. A throughput of 15 samples h(-1), a retention time precision of 2.4% RSD was obtained for 14 consecutively injected cells. The average cellular concentration of GSH in human erythrocytes was found to be 7.2 [times] 10(-4)+/- 3.3 x 10(-4) M (63 +/- 29 amol per cell). The average separation efficiency for GSH in lysed cells was 2.13 x 10(6)+/- 0.4 x 10(6) plates per m, and was about a factor of 5 higher than those obtained with GSH standards using pinched injection.  相似文献   

20.
Koay ES  Zhu M  Wehr T  Choong ML  Khaw MC  Sethi SK  Aw TC 《Talanta》1998,45(4):673-681
The apolipoprotein E (apo-E) genotype of an individual is of significant relevance in the associated risk of developing cardiovascular disease and late-onset Alzheimer's disease. Detection of the six common apo-E genotypes is based on the restriction fragment length polymorphisms (RFLPs) arising from the abolition or creation of HhaI restriction sites within an amplified target DNA sequence of the apo-E gene. Genomic DNA was extracted from leukocytes, a 230 bp target sequence within the apo-E gene was amplified by polymerase chain reaction (PCR) and digested with HhaI, and the restricted DNA fragments separated by capillary electrophoresis (CE). This was performed on the BioFocustrade mark 3000 automated CE system equipped with an experimental laser-induced fluorescence (LIF) detector (Bio-Rad Laboratories, Hercules, CA), using capillaries (27 cm length, 75 mum i.d.) coated internally with polyaminoacryloylethoxyethanol. The analysis buffer (2xTris borate-EDTA, pH 8.3) was supplemented with a proprietary sieving polymer and 0.05 muM thiazole orange six. Samples were injected electrophoretically. Separations were carried out at 40 degrees C under constant voltage, and the emitted fluorescence detected at 515 nm. Restriction fragment lengths of the cleaved PCR products were estimated from the migration times, with a 20/100 bp ladder (Bio-Rad Laboratories 20/100 bp molecular ruler) serving as reference. Six different reproducible patterns were obtained for the six common apo-E genotypes, with good resolution of the component restriction fragments. The calculated sizes of the separated peaks closely corresponded with the predicted restricted fragment lengths for each specific genotype. We believe this is the first published report demonstrating the feasibility of automating the post-PCR detection of the apo-E RFLPs(2). This methodology overcomes the most labour-intensive step in apo-E genotyping, thus making it amenable to routine clinical application.  相似文献   