首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In order to develop a chiral stationary phase (CSP), which has even higher separation ability than the corresponding commercially available crown ether based CSP (OA-8000 having a pseudo-18-crown-6 ether with an OMe group as a selector), chemically bonded type CSP having a phenolic OH group on a crown ring was developed. Normal mobile phases with or without acid additive can be used with this OH type CSP in contrast to the conventional OMe type CSP which has a neutral chiral selector. Enantiomers of 25 out of 27 amino compounds, including 20 amino acids, 5 amino alcohols, and 2 lipophilic amines, were efficiently separated on a column with this CSP. Nine amino compounds out of 27 were separated with better separation factors than the corresponding OMe type CSP. It is noteworthy that the chromatography on this CSP exhibited excellent enantiomer-separations for amines and amino alcohols when triethyl amine was used as an additive in the mobile phase. Comparison of enantiomer separation ability on this OH type of CSP and on the OMe type of CSP and correlation between the enantioselectivity in chiral chromatography and that of the corresponding model compounds in solution imply that the chiral separation arose from chiral recognition in host guest interactions.  相似文献   

2.
A novel chiral stationary phase (CSP) for HPLC was prepared by bonding (R)-1-phenyl-2-(4-methylphenyl)ethylamine amide derivative of (S)-valine to aminopropyl silica gel through a 2-amino-3,5-dinitro-1-carboxamido-benzene unit. The CSP was used for the separation of some amino acid derivatives and pyrethroid insecticides by chiral HPLC. Satisfactory baseline separation required optimization of the variables of mobile phase composition. Use of dichloromethane as modifier in the mobile phase gave baseline separations of amino acid derivatives. The two enantiomers of fenpropathrin and four stereoisomers of fenvalerate were baseline separated using hexane-dichloromethane-ethanol as mobile phase. The results show that the enantioselectivity of the new CSP is better than Pirkle type 1-A column for these compounds. Only partial separations were observed for the stereoisomers of cypermethrin and cyfluthrin, which gave even and eight peaks, respectively.  相似文献   

3.
Vancomycin crystalline degradation products (CDPs) have been introduced as one of the newest and most interesting derivatives of vancomycin for enantiomer separation of a wide variety of chiral compounds. In this attempt, a chiral stationary phase (CSP) has been prepared using diol silica gel based on vancomycin CDPs which led to a new chiral selector with new functionality of functional groups on a microcolumn LC. Different kinds of mobile phases were examined to realize the behavior of the chiral selector in separation of atropine, fluoxetine, amlodipine, mandelic acid, alanine, and phenylalanine which were separated successfully on this column. Good results were obtained by using a polar mobile phase containing water, methanol, and acid additives for separation of chiral acidic compounds and amino acid samples. Considerable results were obtained for analysis of basic compounds by using polar organic mobile phase (POP) containing methanol, acid and base additives. These results can be associated with the presence of the carboxylic acid groups present in new CSP by using a diol silica gel.  相似文献   

4.
Liquid chromatographic comparisons for enantiomer resolution of α-amino acids and chiral primary amino compounds were made using chiral stationary phases (CSPs) prepared by covalently bonding (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18-C-6-TA) of the same chiral selector. The resolution of all α-amino acids on CSP 1 developed in our group was found to be better than that on CSP 2 reported by Machida et al. All α-amino acids examined in this study were well enantioseparated on CSP 1 (α=1.22–2.47), while four analytes were not resolved or all the other analytes were poorly resolved on CSP 2 than on CSP 1. However, in resolving the primary amino compounds without a carbonyl group, CSP 1 was comparable with CSP 2. Although (+)-18-C-6-TA of the same chiral selector was used to prepare CSP 1 and CSP 2, this study showed that different connecting methods for the CSPs might influence their ability to resolve the analytes depending on their structures related to the chiral recognition mechanism.  相似文献   

5.
利用高效液相色谱法,采用从(18-冠-6)-2,3,11,12-四羧((18-crown-6)-2,3,11,12-tetracarboxylic acid,18-C-6-TA)衍生的冠醚类型手性固定相(CSPs),对非甾体抗炎药酰肼衍生物进行手性分离研究.为了手性酸类非甾体抗炎药在冠醚手性固定相上进行手性拆分,采用与肼合成方法导入氨基基团,合成了其酰肼衍生物.色谱条件为:流动相:80%甲醇/水(V/V)含10 mmol/L H2SO4;流速:1.0 mL/min;紫外检测波长:210 nm.结果表明,除酮洛芬之外,其它非甾体抗炎药的酰肼衍生物拆分效果较好(α=1.14~1.26,Rs=0.88~1.43).而且非甾体抗炎药酰肼衍生物在(+)18-C-6-TA衍生的CSP 1和(-)18-C-6-TA衍生的CSP 2上的洗脱顺序得到了相反结果.  相似文献   

6.
A new doubly tethered chiral stationary phase (CSP) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was prepared by attaching the second tethering group to silica gel through a carbon atom of the first tethering group of the corresponding singly tethered CSP, which was previously developed in our laboratory. The new doubly tethered CSP was applied successfully to the resolution of various racemic alpha-amino acids, amines and amino alcohols containing a primary amino group. In most cases, the chiral recognition efficiency of the new doubly tethered CSP was superior to that of the corresponding singly tethered one in the resolution of alpha-amino acids, amines and amino alcohols. In the resolution of some racemic primary amino compounds, the new doubly tethered and the corresponding singly tethered CSPs were complementary with each other. The chiral resolution behaviors on the new doubly tethered CSP were examined with the variation of the type and content of organic and acidic modifiers in aqueous mobile phase and the column temperature. The chiral resolution behaviors on the new doubly tethered CSP were generally quite similar to those on the corresponding singly tethered CSP. The stability of the new doubly tethered CSP was greater than that of the corresponding singly tethered CSP.  相似文献   

7.
Separation of chiral primary amino compounds was efficiently achieved under reversed-phase high performance liquid chromatography (RP-HPLC) conditions using a mixture of non-chiral crown ether (18-crown-6) and dimethyl-β-cyclodextrin (DM-β-CD) in the mobile phase. Under these conditions, the amino group of the chiral compound was protonated in a low pH mobile phase, and then interacted with 18-crown-6 and DM-β-CD to form a sandwiched complex [18-crown-6 + amine + CD]. Enantiomers of the compound in the sandwiched complex were separated with good enantioselectivity. Formation of the sandwiched complex among the chiral compound and additives in the mobile phase is a key step of the chiral separation. Four different chiral amino compounds namely, 1-aminoindan (AI), 1,2,3,4-tetrahydro-1-naphthylamine (THNA), tyrosine (Tyr), and phenylalanine (Phe), were selected to demonstrate the separation using the sandwiched complex mechanism in RP-HPLC.  相似文献   

8.
A chiral stationary phase (CSP) based on (-)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was evaluated for the direct resolution of the enantiomers of dipeptides and tripeptides. The type and concentration of the acid and the methanol content were optimized with regard to retention time and resolution using Ala-Phe as model peptide. A mobile phase consisting of 10 mM sulfuric acid in 70% aqueous methanol was applied to the separation of a set of 16 structurally diverse dipeptides and tripeptides. Generally, the configuration of the amino acid at the N-terminus determined the enantiomer elution order. With a few exceptions the LL- and LD-enantiomers interacted stronger with the CSP compared to the corresponding DD- or DL-enantiomers. The experimental conditions also allowed the simultaneous separation of all four stereoisomers of Ala-Phe. Addition of ammonium sulfate generally reduced retention times and enantiomer resolution. Addition of triethylamine as modifier led to an overall increase of the retention times while the resolution did not show a general trend, increasing in the case of Ala-Ala but decreasing in the case of Ala-Phe.  相似文献   

9.
万古霉素手性固定相的制备与对映体分离研究   总被引:1,自引:0,他引:1  
孟晓荣  史玲  周华凤  侯经国 《色谱》2005,23(3):247-250
采用双官能团试剂4,4′-二苯基甲烷二异氰酸酯在无水二甲基甲酰胺(DMF)中直接与大环糖肽类抗生素万古霉素及γ-氨丙基硅胶键合,得到环状抗生素手性固定相(CSP)并用于高效液相色谱手性分析。实验结果证实,合成的万古霉素CSP在正相和反相条件下均有一定的拆分能力,其中在反相条件下拆分了17种对映体,显示出其较为广泛的拆分范围,且磷酸缓冲体系略优于三乙胺-乙酸缓冲体系;对一些物质,如D,L-丹酰化氨基酸的拆分有一定的规律,能给出绝对构型信息。所制备的CSP在相体系转化时不发生老化和变性,显示了一定的稳定性。对该CSP的拆分机理进行分析所得到的结果与Armstrong等的分析结果基本一致。  相似文献   

10.
Enantiomer separations were performed by capillary electrophoresis-mass spectrometry (CE-MS) with (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18C6H4) as a chiral selector. In order to prevent the introduction of the nonvolatile chiral, selector, 18C6H4, into the nozzle of the CE-MS interface and/or the orifice plate, a partial filling technique was employed in this study. By the partial filling technique, the contamination caused by the nonvolatile chiral selector was avoided not only during the analysis but also during the washing of capillary with the separation solution prior to the run. Several racemic compounds having a primary amino group were successfully separated. Racemic 3-aminopyrrolidine and racemic alpha-amino-epsilon-caprolactam have no strong UV absorption, but such compounds were detected with a high sensitivity by MS detection. In this paper, the effects of the length of separation zone and those of the 18C6H4 concentration were described. As the length of the separation zone was longer or as the concentration of 18C6H4 was higher, the enantiomer resolution was enhanced more and more. However, the optimization of 18C6H4 concentration was practically enough to obtain the baseline separation.  相似文献   

11.
An enantioselective silica rod type chiral stationary phase (CSP) is presented as a novel combination of the well-known enantiomer separation properties of immobilized tert-butyl-carbamoylquinine chiral anion-exchanger selector with the unique properties of monolithic silica material. The chromatographic behavior of the tert-butyl-carbamoylquinine silica rod was studied and compared with a similar prepared particulate material. Good selectivities were achieved for a spectrum of chiral test components like N-derivatized amino acids (DNB- Ac-, DNZ-, Bz-, Z-amino acids) and for Suprofen. The influence of mobile phase parameters, as well as the effect of serially coupling up to six 10 cm monolithic silica columns was studied and put in context to conventional columns of particulate 5 microm type CSP. Using that 60 cm long monolithic column it was possible to improve the enantiomer separation of Suprofen and achieve a baseline separation in less than 10 min of total separation time.  相似文献   

12.
A newly developed procedure to reverse the enantiomer elution order of compounds resolved on chiral stationary phases (CSPs) for HPLC is presented. The optimized analytical protocol is based on the effect of temperature on enantioselectivity and does not involve any changing in mobile phase composition or type of CSP. In essence, the approach entails variable temperature chromatography at two temperatures. The enantiomer separation is performed at a low column temperature, with stopping the flow prior to elution of the less retained enantiomer. Then, the column temperature is changed with the peaks trapped inside the column, followed by elution with the same mobile phase in reverse direction. Under these conditions, the more pronounced loss in free energy of binding for the more strongly bound enantiomer results in an inversion of the elution order. This procedure may be applied to each enantiomer pair that is separated by chiral HPLC under an appreciable enthalpy-control.  相似文献   

13.
In this work a chiral stationary phase was prepared by dynamically coating a monolithic reversed-phase HPLC column with a vancomycin-derivative as chiral selector. A hydrophobic alkyl-chain was attached to the vancomycin molecule, providing the immobilization of the chiral selector on the reversed-phase material. Dansyl amino acids were chosen as model analytes for testing the separation power of the dynamically coated phase. All investigated compounds were separated into their enantiomers. Compared with a conventionally packed vancomycin-CSP, a reversal of the enantiomer elution order was obtained.  相似文献   

14.
W. Lee  E. Bang  W. Lee 《Chromatographia》2003,57(7-8):457-461
Summary The enantiomers of diphenylalanine (DPA) were well separated by chiral HPLC and NMR spectroscopy on the chiral stationary phase (CSP) derived from (18-crown-6)-2,3,11,12-tetracarboxylic acid (18-C-6-TA). The chromatographic parameters such as separation factors and retention times were greatly influenced by the mobile phase conditions. The (+)-18-C-6-TA used in the CSP was also employed as a chiral solvating agent for the enantiodiscrimination of the DPA enantiomers by NMR spectroscopy. The proton of the DPA analyte showing the chemical shift nonequivalences was used in determining the enantiomeric composition of the analyte.  相似文献   

15.
A liquid chromatographic chiral stationary phase (CSP) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was applied for the first time to the resolution of biologically important 1-aryl-1,2,3,4-tetrahydroisoquinolines. The unusual resolution of cyclic secondary amino compounds on a chiral crown ether-based CSP was quite successful with the use of a mixture of methanol-acetonitrile-triethylamine at a ratio of 30/70/0.5 (v/v/v) as a mobile phase. From the chromatographic behaviours for the resolution of seven 1-aryl-1,2,3,4-tetrahydroisoquinolines, the steric bulkiness of the 1-phenyl ring at the chiral center of analytes was concluded to play an important role in the chiral recognition.  相似文献   

16.
Preparation of liquid chromatographic chiral stationary phases (CSPs) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid and their application are reviewed. The various methods of connecting (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid to silica gel covalently or dynamically are demonstrated. The CSPs based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid have been very successful for the resolution of various primary amino compounds with the use of an aqueous mobile phase containing organic and acidic modifiers. In addition, the resolution of secondary amino compounds including beta-blockers and N-(3,5-dinitrobenzoyl)-alpha-amino acids has been demonstrated on a CSP based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid with a non-aqueous mobile phase.  相似文献   

17.
张娟  魏文娟  陈伟  吴元欣  柏正武 《色谱》2010,28(10):971-976
为研究选择体的构型对双选择体固定相手性识别的影响,以(1S,2S)-(~)-二苯基乙二胺及L-(~)-二苯甲酰酒石酸为手性源,合成了一种新的双选择体固定相,并用不同结构的手性样品测试了其手性分离能力。结果表明,这种固定相与以(1R,2R)-(+)-二苯基乙二胺及L(~)-二苯甲酰酒石酸为手性源制备的双选择体固定相有相当的手性分离能力,但这两种固定相所能分离的化合物不尽相同。对双选择体固定相中两个选择体的构型对固定相手性识别的影响进行了探讨。在手性识别中,以不同手性源制备的两个选择体的立体构型不能同时与一个手性样品的立体构型相匹配,从而导致相应的双选择体固定相手性分离能力的下降。  相似文献   

18.
A crown ether-based chiral stationary phase (CSP) without extra aminopropyl groups on the surface of silica gel was newly prepared by bonding (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid to silica gel. The new CSP was applied to the resolution of various racemic alpha-amino acids, amines, and amino alcohols. The chiral recognition efficiency of the new CSP was generally superior to that of the original CSP containing unreacted residual aminopropyl groups on the surface of silica gel in terms of the separation (alpha) and the resolution factors (Rs). The retention behaviors of analytes on the new CSP with the variation of the content of organic and acidic modifiers in aqueous mobile phase were consistent with those on the original CSP in the resolution of alpha-amino acids, but somewhat different in the resolution of racemic amines and amino alcohols from those on the original CSP and the difference was rationalized by the lipophilicity difference of the two CSPs. The effect of the column temperature on the chromatographic resolution behaviors on the new CSP was consistent with that on the original CSP.  相似文献   

19.
《Tetrahedron: Asymmetry》2006,17(12):1883-1889
This paper reports the preparation and testing of a new pyridino-18-crown-6 ether based chiral stationary phase (CSP). The chiral crown ether was covalently bound to silica gel. Circular dichroism (CD) spectroscopy was used for probing the complex formation of the chiral crown ether with the enantiomers of protonated primary arylalkylamines. The (S,S)-dimethylpyridino-18-crown-6 ether selector having a terminal double bond was first transformed to a triethoxysilyl derivative by regioselective hydrosilylation, and then heated with spherical HPLC quality silica gel to obtain the CSP. The discriminating power of the HPLC column filled with the above CSP was tested by using the hydrogenperchlorate salts of racemic α-(1-naphthyl)ethylamine (1-NEA), α-(2-naphthyl)ethylamine (2-NEA) and the hydrochloride salts of aromatic α-amino acids and α-amino acids containing different aromatic side-chain protecting groups.  相似文献   

20.
This paper describes enantiomer separation using four kinds of chiral stationary phases (CSPs) where quaternary ammonium surfactants containing L-valine diamide moieties into long alkyl chains were bound to silicagel supports by reversed phase liquid chromatography. Our aim was to examine hydrogen bonding association of the chiral moiety in hydrophobic phase brought about by aggregation of the micelle-forming surfactants on the surface. The following CSPs were thus derived from the vinyl-terminated chiral surfactants via hydrosilylation: CSP 1 from N-[3-(10-undecenoyl-L-valylamino)propyl]-N,N,N-trimethylammonium bromide, CSP 2 from N-[6-(10-undecenoyl-L-valylamino)hexyl]-N,N,N-trimethyl-ammonium bromide, CSP 3 from N-[3-(10-undecenoyl-L-valylamino)propyl]-N-octadecanyl-N,N-dimethyl-ammonium bromide and CSP 4 from N-[6-(10-undecenoyl-L-valylamino)hexyl]-N-octadecanyl-N,N-dimethylammonium bromide. The degree of hydrophobicity in the interfacial phase was observed by measuring pyrene fluorescence in aqueous media including an organic modifier. Retention of racemic N-acylleucine isopropyl esters was highest in CSP 4, followed by 3, 2, and 1. Largest alpha values toward enantiomer separation were observed for CSP 4 where the chiral moieties were kept through a hexamethylene unit apart from the polar head groups and to which another long alkyl chain was attached, as compared with those for CSP 4. In CSP 4, the chiral moiety to interact with enantiomeric solutes should be buried into the interfacial phase deeply in more extent than CSP 3. In a similar manner, CSP 2 has more effective for enantiomer separation than CSP 1. The interfacial phase of these CSPs was easily exposed to the bulk phase because of the affinity between the bulk phase and the polar head groups as well as their electrostatic repulsion. However, degree of the enantiomer separation can be controlled by the depth of the chiral moiety in the hydrophobic interfacial phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号