首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sastry CS  Rao JS  Rao KR 《Talanta》1995,42(10):1479-1485
Three simple and sensitive spectrophotometric methods for the determination of tamoxifen citrate have been developed. They are based on the formation of an ion-association complex between the drug and a dye, Erioglaucine A, which is extractable into chloroform and has an absorption maximum at 625 nm (method A), oxidation with excess potassium permanganate and the determination of unconsumed permanganate using Fast Green FCF (method B), or by the formation of a coloured cobalt thiocyante coordination complex which is extracted into benzene and measured at 635 nm (method C). Beer's law limits for methods A, B, and C are 0.5-3.0 mug ml(-1), 1.0-6.0 mug ml(-1) and 100-500 mug ml(-1), respectively. No interference was observed from tableting additives and the applicability of the methods was examined by analysing tablets containing tamoxifen. The quantities determined were 99.0-100.03% of the exptected values.  相似文献   

2.
Raychaudhuri A  Roy SK  Chakraburtty AK 《Talanta》1992,39(10):1377-1382
A simple procedure for selective sorption of tungsten is described. The method involves reduction of W(VI) to W(V) with tin(II) chloride (2%, w/v) at 8-9M hydrochloric acid, formation of the W(V)-SCN complex with 0.2M KSCN and its sorption on polyurethane foam within 20 min. The sorbed complex is then eluted with acidified acetone (1 ml of 1M hydrochloric acid and 8 ml of acetone) followed by addition of 1 ml of 0.1M KSCN to the eluent. The method has been applied to the spectrophotometric determination of tungsten in steels and silicates by measuring the absorbance of the eluted solution at 400 nm. Beer's law is obeyed for the range 0.1-12 mug W/ml. Other elements, e.g., Co(III) (50 mug/ml), Cu(II) (10 mug/ml), Ti(IV) (20 mug/ml), V(V) (10 mug/ml) and Mo(VI) (0.5 mug/ml) have no effect on the method. Interference of copper, up to 100 mug/ml has been eliminated by masking with thiourea and that due to molybdenum by prior separation with thioglycollic acid on PUF. The method has been verified with standard samples.  相似文献   

3.
Huang X  Zhang W  Han S  Yin Y  Xu G  Wang X 《Talanta》1997,45(1):127-135
Different micellar media had different effects on the absorption spectra of the complexes of bromopyrogallol red with Sb(III) and Sb(V). The mixed micellar medium composed of 0.7 ml of 0.2% sodium dodecylsulfate (SDS) and 0.3 ml of 2% nonylphenoxypolyethoxyethanol (OP) at 80 degrees C could be used for the sensitive determination of Sb(III) in Sb(III)/Sb(V) binary mixtures. Under the optimal conditions, Beer's Law was obeyed over the range 0.1-2.3 mug ml(-1) Sb(III) with molar absorptivity at 538 nm being 4.8 x 10(4) l mol(-1) cm(-1) and detection limit 0.04 mug ml(-1). For 10 mug Sb(III), more than 100 mug Sb(V) could be tolerated (error < 3%) in the presence of SDS/OP micellar medium as compared with 0.1 mug Sb(V) in the absence of SDS/OP micellar medium. In addition, the sensitivity of Sb(III) in the micellar medium was much higher than that in pure water medium. As compared with conventional extraction spectrometry, the proposed method produced a reproducible result. It did not need the conversion of Sb(III) to Sb(V) and a time-consuming extraction process. A detailed discussion on the selection of surfactants, the effect of temperature, and the role played by the mixed surfactants were also made.  相似文献   

4.
Polásek M  Jambor M 《Talanta》2002,58(6):1253-1261
Antibacterial drug trimethoprim [2,4-diamino-5-(3,4,5-trimethoxybenzyl)-pyrimidine] (I) was determined in pharmaceutical formulations by using a lab-made PC-controlled SIA analyser linked to conventional HPLC fluorimetric detector equipped with a chemiluminescence module. The chemical principle is the oxidation of I by KMnO(4) in acid medium; the reaction is accompanied by the emission of chemiluminescence, which is enhanced in the presence of hexametaphosphate (HMP). The optimum sequence and the flow parameters and concentrations and volumes of reagents aspirated optimised by a computer-aided simplex method were, 100 mul of 5 mM HMP, 40 mul of a test solution of I, 2 mul of 0.5 M H(2)SO(4) and 20 mul of 1 mM KMnO(4); the luminescing zone was pushed into the detector at a flow rate of 49 mul s(-1). The calibration graph relating the intensity of luminescence to concentration of I was parabolic (r=0.9994) in the range 0.5-100 mug ml(-1) of I with rectilinear part (r=0.9999) in the range 20-100 mug ml(-1) of I; the limit of detection was 0.1 mug ml(-1) of I. The method was used for the assay of Triprim(R) tablets (with nominal content 100 or 200 mg of I) for the active substance as well as for content uniformity tests; the R.S.D. values did not exceed 1% (n=5). The SIA results did not show statistical difference from those obtained by pharmacopoeial acidimetric titration in non-aqueous medium; the excipients such as microcrystalline cellulose, maze starch, povidone, talc, magnesium stearate and gelatin did not interfere.  相似文献   

5.
Heitner-Wirguin C  Gancz M 《Talanta》1967,14(6):671-675
A precise spectrophotometric method for the determination of 2.5-25 mug of vanadium in volumes of up to 500 ml of water was developed. The method is based on the simultaneous concentration (100-1000 fold) and complexation of vanadium(V) with di-iodo-oxine in a water-immiscible phase. Interference from iron is eliminated by masking with phosphoric acid. The standard deviation evaluated was +/-0.04 mug for solutions containing 5 mug vanadium.  相似文献   

6.
Two simple and sensitive extractive spectrophotometric methods for the determination of sildenafil citrate (SC) are proposed. The methods are based on the formation of ion-association complexes of sildenafil citrate with bromocresol green (BCG, method A) and with chromoxane cyanine R (CCR, method B) in aqueous acidic buffer. The complex species, extractable to chloroform phase, were quantitatively measured at 415 and 460 nm for methods A and B, respectively. Beer's law was obeyed in the SC concentration range 1.25-25 mug ml(-1) with a limit of detection 0.16 mug ml(-1) and 1.5-60 mug ml(-1) with a limit of detection 0.18 mug ml(-1), respectively, for methods A and B. The methods have been successfully applied to the analysis of bulk drug and its tablets. No interference was observed from common pharmaceutical adjuvants.  相似文献   

7.
A sequential injection analysis (SIA) assembly for the atomic absorption determination of Fe(III) in natural waters is proposed. Iron is preconcentrated on a microcolumn packed with a chelating resin (Chelex 100) that is inserted in the manifold. The sample is passed through the column and the iron retained by the resin is subsequently eluted with 2 M HNO(3). The proposed SIA system affords automatic preconcentration, elution, detection of Fe(III), data acquisition and treatment. When 9 ml of iron solution containing 0.4 or 1 mg l(-1) was passed through the resin, the retention efficiency was 93.1 +/- 0.6 and 7.4 +/- 3.0% respectively, and when 27 ml of iron solution of 0.2 mg l(-1) was preconcentrated, the retention was 8.4 +/- 2.9%. The detection limits thus achieved is 12 mug l(-1) when 9 ml of sample are preconcentrated and 6 mug l(-1) for 27 ml.  相似文献   

8.
Haghighi B  Tavassoli A 《Talanta》2002,56(1):137-144
A flow injection method on the basis of gas phase molecular absorption is described for the determination of nitrite in the aqueous solution. 200 mul of nitrite solution is introduced into a carrier stream of distilled water. The carrier stream containing nitrite zone is reacted with a stream of hydrochloric acid (2 M). The stream is then segmented by O(2) gas. The produced gaseous products are purged into the O(2) segments, react with O(2) and are carried toward the gas-liquid separator. The gaseous phase is separated from the liquid stream by the use of home-made gas-liquid separator and then is swept into a home-made flow cell. The absorbance of gaseous phase is measured at 205 nm using a UV/VIS spectrophotometer. Under selected conditions, two linear ranges, up to 1000 mug ml(-1) and 1000-2000 mug ml(-1) of nitrite were obtained. The limit of detection was 7.5 mug ml(-1) NO(2)(-). The relative standard deviations of repeated measurements of 100 and 500 mug ml(-1) NO(2)(-) were 3.7 and 1.0%, respectively. Up to 30 samples h(-1) can be analyzed. Interferences in the proposed method were few and were readily overcome. The proposed method was successfully applied to the determination of nitrite in the spiked water samples, a number of meat products and urine.  相似文献   

9.
Sedaira H 《Talanta》2000,51(1):39-48
A new direct spectrophotometric determination of manganese with 5,8-dihydroxy-1,4-naphthoquinone (naphthazarin,NAZA) is reported. Absorption maximum, molar absorptivity and Sandell's sensitivity of 1:2 (M:L) complex are 695 nm, 1.88x10(4) l mol(-1) cm(-1) and 2.92 ng cm(-2), respectively. A linear calibration graph is obtained up to a concentration of 7.2 mug ml(-1) of manganese. The optimum range for determination (Ringbom) is between 0.20 and 6.8 mug ml(-1). A rapid method for simultaneous determination of manganese and zinc in their mixture using derivative spectra is described. The range 0.28-5.6 mug ml(-1) manganese could be determined in the presence of 0.33-6.8 mug ml(-1) zinc and vice versa. The developed method was applied to the simultaneous spectrophotometric determination of manganese and zinc in some synthetic mixtures and was found to give satisfactory results.  相似文献   

10.
Parkash R  Bansal R  Kaur A  Rehani SK 《Talanta》1991,38(10):1163-1165
A sensitive and inexpensive method of spectrophotometric determination of chromium(VI), based on the absorbance of its complex with malachite green and acetic acid at pH 2.5 is reported. The complex shows a molar absorptivity of 8 x 10(4) l.mole(-1) cm(-1) at 560 nm, using malachite green and acetic acid as reference solution. The effect of time, temperature, pH and reagent concentration is studied and optimum operating conditions are established. Beer's law is applicable in the concentration range 2.0-22.8 mug/ml chromium(VI). The resin beads act as a catalyst and as little as 1.6 mug of chromium(VI) is detected in the resin phase as compared to 4.1 mug in the solution phase. The standard deviation in the determinations is +/-0.40 mug/ml for a 10.35 mug/ml solution.  相似文献   

11.
Zhou N  Gu YX  Lu ZR  Chen WY 《Talanta》1989,36(7):739-742
A new spectrophotometric method for the determination of zinc is proposed. The chromogenic agent Hydrazidazol forms a 1:1 chelate with zinc in the presence of Triton X-100 in a medium containing 20-40% ethanol. The molar absorptivity and conditional formation constant have been found to be 2.7 x 1O(4) l.mole(-1).cm(-1) (at 640 nm) and 10(5.32) respectively. Beer's law is obeyed for zinc over the range of 0.2-0.8 mug/ml with a standard deviation of 0.024 mug/ml. The method can be applied to the determination of zinc in cadmium metal and its oxide after preconcentration by selective extraction of zinc thiocyanate into ethyl acetate in the presence of EDTA and thiosulphate as masking agents.  相似文献   

12.
Yang W  Teng XL  Chen M  Gao JZ  Yuan L  Kang JW  Ou QY  Liu SX 《Talanta》1998,46(4):527-532
In the present paper, N,N'-dinaphthyl-N,N'-diphenyl-3,6-dioxaoctanediamide acts as a specific reagent for enhancing the fluorescence intensity of Eu(III) complex with thenoyl trifluoroacetone (TTA), the spectrofluorimetric determination of trace amounts of Eu(III) based on the above system was carried out and its luminescence mechanism was studied. The excitation and emission wavelengths are 343.6 and 613.3 nm, respectively. The fluorescence intensities vary linearly with the concentration of europium(III) in the range 3.647x10(-3)-3.039 mug ml(-1) for the original fluorescence with a detection limit down to 2.279x10(-4) mug ml(-1) and the standard deviation is 0.063 mug ml(-1) for 10 times measurements, and in the range 7.598x10(-4)-0.0243 mug ml(-1) (SD=0.035 for 15 times measurements), 0.06078-0.6100 mug ml(-1) (SD=0.52 for 10 times measurements) for the first derivative fluorescence signal with a detection limit down to 8.566x10(-5) mug ml(-1). The interferences of other rare earths and some of inorganic ions are described. This method is a direct, rapid, selective and sensitive analytical method for the determination of trivalent europium in rare earth ore samples and high purity of rare earth oxides.  相似文献   

13.
Thakur M  Deb MK 《Talanta》1999,49(3):561-569
A simple and sensitive field detection and spectrophotometric method for determination of copper described herewith is based on the formation of a red coloured species of copper(II) with 1-[pyridyl-(2)-azo]-naphthol-(2) (PAN), TX-100 and N,N'-diphenylbenzamidine (DPBA) at pH range 7.8-9.4. The red coloured Cu(II)-PAN-(TX-100)-DPBA complex in chloroform shows maximum absorbance at 520 nm with molar absorptivity value of 1.14x10(5) l mol(-1) cm(-1). The detection limit of the method is 2 ng ml(-1) organic phase. The system obeys Beer's law up to 0.6 mug Cu(II) ml(-1) in organic solution. Most of the common metal ions generally found associated with copper do not interfere. The repeatability of the method was checked by finding relative standard deviation (RSD) (n=10) value for solutions each containing 0.2 mug ml(-1) of Cu(II) and the RSD value of the method was found to be 1.5%. The validity of the method has been satisfactorily examined for the determination of copper in soil and airborne dust particulate samples.  相似文献   

14.
Aly FA  Alarfaj NA  Alwarthan AA 《Talanta》2001,54(4):715-725
A simple, highly sensitive chemiluminescent method using flow injection is described for the determination of three substituted benzamides, namely: sulpiride, sultopride and tiapride. The method is based on the sensitizing effect of these drugs on the chemiluminometric oxidation of sulphite by cerium(IV). The different experimental parameters affecting the chemiluminescence intensity were carefully studied and incorporated into the procedure. The method permits the determination of 0.05-2.5 mug ml(-1) sulpiride, 0.01-2.5 mug ml(-1) sultopride hydrochloride and 0.01-1.5 mug ml(-1) tiapride hydrochloride with minimum detectability of 0.01 mug ml(-1). The method was applied to the determination of these benzamides in pharmaceutical preparations and biological fluids.  相似文献   

15.
In the present work, erioglaucine A was applied as internal standard to enhanced spectrophotometric determination of chromium (VI) with diphenylcarbazide. The following procedure was used: (1) addition of internal standard and formation of ion pairs of Cr (VI) with benzyltributylammonium bromide (BTAB) (sample volume 100 ml), (2) extraction to 10 ml of methylene chloride, (3) evaporation in nitrogen stream, and (4) redissolution in a micro-volume with addition of diphenylcarbazide for color development (final volume 200 mul). The preconcentration factor achieved was about 400 and it was shown that, using internal standard, the analytical errors due to sample treatment were reduced. The analytical signals for chromium and internal standard were obtained at 591.30 and 653.50 nm from first derivative spectra, normalized against (1)D(653.50nm). The analytical characteristics evaluated were: detection limit = 0.06 mug l(-1), quantification limit = 0.19 mug l(-1), precision for 1 mug l(-1) 14.2%, and for 10 mug l(-1) 3.2%, correlation coefficient of linear regression was 0.9985. The proposed procedure was applied to determination of chromium (VI) in tap water. Total chromium was determined by electrothermal atomic absorption spectrometry, the recovery of hexavalent chromium added was then evaluated and compared with the results of the proposed procedure. In this experiment, good agreement was obtained between results obtained by the two methods.  相似文献   

16.
In this paper, the on-line coupling of solid-phase extraction, based on a restricted-access support with high-performance reverse phase chromatography for the analysis of carbamazepine (CBZ) and carbamazepine-10,11-epoxide (CBZ-E) in human plasma samples is described. A precolumn packed with 25 mum C(18) alkyl-diol support is used for direct plasma injection. Using column-switching techniques, the analytes were enriched on the precolumn by a 5 mM phosphate buffer (pH 7) with 2% of methanol solution at a flow-rate of 0.8 ml min(-1), while proteins and endogenous hydrophilic substances in plasma were washed off to waste. The enriched analytes were then back-flushed onto the analytical C(18) column, separated by a mixture of 10 mM phosphate buffer (pH 7) acetonitrile (70:30 v/v) solution at a flow-rate of 1.0 ml min(-1) and detected by the ultraviolet absorbance set at 212 and 285 nm and without transfer loss. Linear calibration graphs were obtained for sample injection volumes of 50 (0.2-4.0 of mug of CBZ ml(-1) and 0.1-5.0 mug of CBZ-E ml(-1), respectively), and 20 mul (5.0-20.0 mug of CBZ ml(-1)); in either case the r-value was >0.9963. Recoveries from spiked plasma samples were quantitative for both analytes and the coefficients of variation were below 3.83%. The lowest samples concentrations that can be quantified with acceptable accuracy and precision was 0.2 mug CBZ ml(-1) and 0.1 mug CBZ-E ml(-1) when a sample volume of 50 mul was injected. Concentrations of 0.08 and 0.05 mug ml(-1) of CBZ and CBZ-E were considered the limit of detection for a signal-to-noise ratio of 3. Furthermore, the developed column-switching method was successfully applied to the determination of CBZ and CBZ-E in plasma samples of patients submitted to CBZ therapy.  相似文献   

17.
A simple and sensitive spectrophotometric method for determination of copper(II) is based on the formation of a blue coloured complex of Cu(II) with 9-phenyl-2,3,7-trihydroxy-6-fluorone (PF) in the presence of cetylpyridinium chloride (CP) and Triton X-100, has been developed. Optimum concentrations of PF, CP, Triton X-100 and pH ensuring maximum absorbance were defined. The complex Cu(II)-PF-CP-Triton X-100 shows maximum absorbance at 595 nm with a molar absorptivity value of 9.67x10(4) l mol(-1) cm(-1). The detection limit of the method is 0.028 mug ml(-1). Beer's law is obeyed for copper concentrations in the range 0.04-0.4 mug ml(-1). The studies of the effect of foreign ions on determination of copper, show that the selectivity of the method is poor. The cations of alkali metals and anions Br(-), Cl(-), I(-), F(-), NO(2)(-), NO(3)(-), CH(3)COO(-), SO(4)(2-), S(2)O(3)(2-), PO(4)(3-), citrates (examined in 1000-fold molar excess over copper) do not affect the determination. All cations forming complexes with PF have an interfering effect. The statistical evaluation of the method was carried out for six determinations using 10 mug of Cu and the following results were obtained: the standard deviation, SD=0.042, the confidence interval mu(95)=10.1+/-0.1 mug Cu. The method has been applied for determination of copper in blood serum.  相似文献   

18.
Monser L  Sadok S  Greenway GM  Shah I  Uglow RF 《Talanta》2002,57(3):511-518
A direct spectrophotometric flow injection method for the simultaneous determination of nitrite and nitrate has been developed. The method is based on the oxidation of a phosphomolybdenum blue complex by the addition of nitrite and the decrease in absorbance of the blue complex is monitored at 820 nm. The injected sample is split into two segments. One of the streams was directly reacted with the above reagent and detected as nitrite. The other stream was passed through a copperised cadmium reductor column where reduction of nitrate to nitrite occurs, and the sample was then mixed with the reagent and passed through the cell of the spectrophotometer to be detected as nitrite plus nitrate. The conditions for the flow injection manifold parameters were optimised by experimental design and the concentration of nitrite and nitrate was determined in the linear range from 0.05 to 1.15 mug ml(-1) nitrite and 0.06 to 1.6 mug ml(-1) nitrate with a detection limit of 0.01 mug ml(-1) for nitrite and 0.025 mug ml(-1) for nitrate. The method is suitable for the simultaneous determination of nitrite and nitrate in fish and water samples with a sampling rate of 25+/-2 sample per hour.  相似文献   

19.
Du J  Li Y  Lu J 《Talanta》2002,57(4):661-665
A new flow injection chemiluminescence (CL) method is proposed for the determination of thiamine, based upon its enhancing effect on the CL reaction of luminol with hydrogen peroxide in alkaline solution. The method allows the determination of thiamine within 0.05-8 mug ml(-1) range with a detection limit (3sigma) of 0.01 mug ml(-1). The relative standard deviation is 1.4% (n=11, 0.5 mug ml(-1) thiamine) and the sample throughput is about 90 samples h(-1). The method was successfully applied to the determination of thiamine in pharmaceutical preparations.  相似文献   

20.
Zhang Z  Qin W 《Talanta》1996,43(1):119-124
A novel flow sensor based on chemiluminescence (CL) for the determination of ascorbic acid has been proposed. The analytical reagents, luminol and ferricyanide, were both immobilized on an anion-exchange resin column. The CL signal produced by the reaction between luminol and ferricyanide, which were eluted from the column through sodium phosphate injection, was decreased in the presence of ascorbic acid. The CL emission intensity was linear with ascorbic acid concentration in the range 0.01-0.8 mug ml(-1); the detection limit was 5.5 x 10(-3) mug ml(-1). The whole process, including sampling and washing, could be completed in 1 min with a relative standard deviation of less than 5%. The sensor could be reused more than 100 times and has been applied successfully to the analysis of ascorbic acid in pills and vegetables.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号