首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   35篇
  免费   0篇
  国内免费   1篇
化学   34篇
物理学   2篇
  2013年   3篇
  2012年   1篇
  2011年   2篇
  2010年   1篇
  2008年   2篇
  2007年   1篇
  2006年   2篇
  2005年   1篇
  2004年   1篇
  2002年   3篇
  2001年   5篇
  2000年   1篇
  1999年   1篇
  1996年   1篇
  1993年   1篇
  1992年   1篇
  1991年   2篇
  1990年   2篇
  1989年   3篇
  1987年   1篇
  1978年   1篇
排序方式: 共有36条查询结果,搜索用时 156 毫秒
1.
2.
Coumarin C343 (C(16)H(15)NO(4)), a dye used to enhance the weak chemiluminescence associated with lipid peroxidation, was conjugated to silica nanoparticles and entrapped in a sol-gel matrix to produce a nanosensor capable of enhancing low-level chemiluminescence by approximately 100%.  相似文献   
3.
研究了基于微芯片电泳分离和电感耦合等离子体质谱的连接技术,并对不同形态的Cu和As进行了快速分离和检测.  相似文献   
4.
An electrogenerated chemiluminescence (ECL) method for the determination of pethidine, atropine, homatropine and cocaine is described. The optimum conditions were found to be similar for all of these compounds although the ECL emission intensity for cocaine was an order of magnitude lower than for pethidine due to their different chemical structures. Linear calibrations were obtained for all the compounds at pH 10 in borate buffer (0.05 mol l-1) at 1.3 V. Limits of detection of 6.8 x 10(-8), 2.2 x 10(-7), 3.2 x 10(-7) and 6.5 x 10(-7) mol l-1, respectively, were achieved for pethidine, atropine, homatropine and cocaine in standard solutions. Solid-phase extraction was used to separate the drugs from their matrix and the method was applied to the determination of spiked urine samples. The limits of quantitation for pethidine, atropine, homatropine and cocaine in urine were 1.0 x 10(-6), 2.0 x 10(-6), 2.0 x 10(-6) and 4.0 x 10(-6) mol l-1, respectively, with recoveries of between 90 and 110%.  相似文献   
5.
A novel chemiluminescence (CL) microfluidic system incorporating a molecularly imprinted polymer (MIP) preconcentration step was used for the determination of chloramphenicol in honey samples. The MIP was prepared by using chloramphenicol as the template, diethylaminoethyl methacrylate (DAM) as the function monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linking monomer, 2, 2′-dimethoxy-2-phenylacetophenone (DMPA) as the free radical initiator and toluene and dodecanol as the solvent. The MIP was pre-loaded into a 10 mm long, 2 mm wide and 150 μm deep channel in a planar glass microfluidic device. When the sample containing chloramphenicol was introduced into the microfluidic device it was first preconcentrated on the MIP then detected by an enhancement effect on the chemiluminescence reaction of tris(2, 2′-bipyridyl) ruthenium(II) with cerium(IV) sulphate in sulphuric acid. A micro-syringe pump was used to pump the reagents. The CL intensity was linear in relationship to the chloramphenicol concentrations from 1.55 × 10−4 to 3.09 × 10−3 μmol L−1 (r2 = 0.9915) and the detection limit (3σ) and the quantitation limit (10σ) were found to be 7.46 × 10−6 and 2.48 × 10−5 μmol L−1, respectively. This method offered a high selectivity and sensitivity for quantitative analysis of chloramphenicol in the honey samples.  相似文献   
6.
7.
A small range of new commercially available chelating resins are compared with a resin prepared in-house in terms of their applicability for on-line preconcentration and matrix separation. The flow injection manifold was designed for rapid matrix separation and the resins were tested for the determination of Cull, ZnII, CdII, MnII and NiII. The resin based on controlled pore glass was found to be better for this rapid procedure because it did not require conditioning, although the polymer based resins had better capacities. The commercially available controlled pore glass based iminodiacetate (IDA) resin had a comparable performance to the in-house controlled pore glass 8-hydroxyquinoline (CPG-8-HQ) resin. The IDA resin had a much higher capacity than the 8-HQ, however as with all IDA based resins, some retention of Call was observed. The sample throughput was 12 h−1.  相似文献   
8.
This paper describes the electric field-induced flow characteristics of multiphase solutions in a micro reactor device using the nitration of benzene as a model process. Photolithographic and wet etching techniques were used to fabricate the micro reactor (channels, 200 microns id, 100 microns deep) in a borosilicate glass substrate. The results focus specifically on the flow parameters of reagents/reactants (i.e., voltage, solution concentration and pH ranges and current-voltage relationships) used in this study. The benzene was introduced and mobilised by electroosmotic flow (EOF), as a microemulsion using an appropriate surfactant (sodium dodecyl sulfate), whilst the nitronium ions, produced in situ from mixed H2SO4-HNO3 (the nitrating agent), underwent electrophoretic-induced (electrokinetic) mobility. A co-surfactant, butan-1-ol, was used owing to (a) its relative solubility in the aqueous surfactant solution, (b) its ability to aid the solubilization of benzene, (c) the provision of a water-rich (oil-in-water) rather than oil-rich (water-in-oil) microemulsion system and (d) its lack of significant adverse effects on the EOF. The optimum conditions used for the nitration of benzene within the micro reactor were a run of the microemulsion as main reagent stream, then three 30 s segmented injections of mixed acid, with a 5 s push of the microemulsion into the system after each injection, and then a 60 s stopped-flow reaction time before driving reaction product segments to a collection reservoir.  相似文献   
9.
Sol-gel nanoprobes, also known as Photonic Explorer for Bioanalysis with Biologically Localised Embedding (PEBBLE), capable of performing in-vitro intracellular monitoring of reactive oxygen species have been developed using a modified form of 5(6)-carboxyfluorescein diacetate. A sol-gel matrix was selected for the design of the probes as it is photostable, optically transparent and chemically inert, and to minimise leaching of the dye from the porous matrix it was covalently immobilised to silica nanoparticles (15 nm). Using this approach, 0.1% of the dye was found to leach over a typical analysis time of 5 h and minimal photobleaching was observed. In addition, the nanoprobes were shown to respond to hydrogen peroxide, hydroxyl anions, nitric oxide, peroxynitrile and superoxide anions, obtaining limits of detection of 2.2, 1.1, 3.2, 1.1 and 1.1 nM respectively. The nanoprobes were subsequently introduced into bovine oviducts using a lipid transfection reagent (Escort IV) and fluorescence was observed.  相似文献   
10.
The crystal and molecular structures of [Me2Etim]Cl, [Me2Etim]2[CoCl4], and [Me2Etim]2[NiCl4] ([Me2Etim]+ = 1,2-dimethyl-3-ethylimidazolium cation) all contain evidence that the H4 and H5 protons of the imidazolium cation enter into hydrogen bonds; the implications of this observation for the interactions in room-temperature chloroaluminate(III) ionic liquids are considered.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号