首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel palladium-polyphenosafranine nano-composite (PPS-Pd) was synthesized by electrochemical co-deposition at a glassy carbon electrode (GCE) for fabrication of a nitrite sensor, PPS-Pd/GCE. This PPS-Pd film was characterized by X-ray photoelectron spectroscopy (XPS) and field emission scanning electron microanalysis (SEM). It was found that the PPS-Pd nano-composite consisted of Pd nanoparticles smaller than 10 nm in diameter which stick together due to the polymer, forming a Pd-embedded PPS layer structure. The sensing ability was investigated by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and differential pulse amperometry (DPA). The PPS-Pd/GCE had excellent catalytic activity toward the oxidation of nitrite: high current sensitivity of 0.365 A/M cm(-2), good reproducibility, good stability and fast response. In neutral solutions, a linear concentration range of 1.0 x 10(-6) to 1.1 x 10(-3) M (R(2) = 0.999) with the detection limit (s/n = 3) of 3 x 10(-7) M nitrite was obtained for DPV determination.  相似文献   

2.
A new electrochemical sensor based on Poly(Isoleucine) modified glassy carbon electrode decorated with platinum nanoparticles (Pt/Poly(Isoleucine)/GCE) was developed for sensitive individual and simultaneous determination of hydroquinone (HQ) and catechol (CC). Scanning electron microscopy (SEM), Electrochemical impedance spectroscopy (EIS), Cyclic voltammetry (CV) and Differential pulse voltammetry (DPV) were performed in order to characterize the Pt/Poly(Isoleucine)/GCE nanocomposite. For simultaneous determination of HQ and CC, Pt/Poly(Isoleucine)/GCE showed wide linear range between the 0.01–100.0 μM. The detection limits were 0.006 μM for HQ and 0.005 μM for CC. The Pt/Poly(Isoleucine)/GC electrode exhibited good sensitivity and reliability in the simultaneous electroanalysis of two isomers in PBS of pH 7.5. The modified electrode was used to detect the isomers in naturel samples.  相似文献   

3.
Dopamine (DA), a critical catecholamine neurotransmitter, is responsible for normal functioning of body. Its dysregulation causes cognitive disturbances. Thus, an efficient real time monitoring of DA in clinical samples is required. Herein we report a novel nanocomposite comprising of carbon nanocoils (CNC) and copper tetra(p-methoxyphenyl)porphyrin (CuTMePP) for efficient electrochemical detection of dopamine that was characterized by FTIR, UV/vis., Raman, XRD, SEM, TEM and energy dispersive X-ray techniques. The electrochemical studies were performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy and differential pulse voltammetry (DPV). CNC/CuTMePP/glassy carbon (GC) has demonstrated two linear trends between current and concentration i.e. 0.1 to 100.0 µM and 100.0 to 800.0 µM. Limit of detection (LoD), limit of quantification (LoQ) and sensitivity of the electrode in the concentration range of 0.1 to 100.0 µM was 50.0 nM, 167.0 nM and 1.76 µAµM-1cm?2, respectively using CV. With DPV, the LoD, LoQ and sensitivity were found to be 64.0 nM, 211.0 nM and 0.75 µAµM-1cm?2, respectively obtained in a concentration range of 0.1 to 100.0 µM. The as prepared sensor exhibited good intra/inter-day stabilities, reproducibility, excellent recovery in the human serum samples, presented significant clinical dopamine detection and showed comparable results with other work in literature.  相似文献   

4.
The electrooxidation of epinephrine (EPI) and piroxicam (PRX) has been investigated by application of nickel hydroxide nanoparticles/multiwalled carbon nanotubes composite electrode (MWCNTs‐NHNPs/GCE) using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) methods. The modified electrode showed suitable electrochemical responses for EPI and PRX determination. Under the optimum conditions the electrode provides a linear response versus EPI and PRX concentrations in the range of 1–220 µM and 0.7–75 µM, respectively using the DPV method. Linear responses versus EPI and PRX concentrations in the range of 1–1000 µM and 1–800 µM, respectively, were obtained using the CA method. The modified electrode was used for determination of EPI and PRX in human urine with satisfactory results.  相似文献   

5.
In this work, thionine (Th) was assembled on the surface of graphene oxide as an electron transfer mediator using diazonium reaction (Th–GO). Then, Th–GO was characterized by different methods such as scanning electron microscopy, transmission electron microscopy, and Fourier transform infrared spectroscopy. Afterward, Th–GO was used for the modification of carbon paste electrode. Several electrochemical methods including cyclic voltammetry, differential pulse voltammetry, and hydrodynamic amperometry were used to investigate the behavior of the modified electrode. Then, the role of the modified electrode for oxidation of nitrite has been studied. For this purpose, the effect of critical experimental parameters including step potential and pulse amplitude (in differential pulse voltammetry technique), applied potential, the rotating speed of the disk (in amperometry technique), and the solution pH was investigated. Under the optimized conditions, the currents were found to be linear with the nitrite concentration in the range 0.05–33.0 and 0.5–800 µmol L?1 with detection limits of 0.02 and 0.2 µmol L?1 using differential pulse voltammetry and hydrodynamic amperometry, respectively. The introduced modified electrode showed good repeatability (RSD% = 3.2) and reproducibility (RSD% = 4.7). This electrochemical sensor was exerted successfully for the determination of nitrite and nitrate in real samples including water and wastewater samples.  相似文献   

6.
《Electroanalysis》2017,29(2):345-351
A glassy carbon electrode modified with reduced graphene oxide and platinum nanocomposite film was developed simply by electrochemical method for the sensitive and selective detection of nitrite in water. The electrochemical reduction of graphene oxide (GO) efficiently eliminates oxygen‐containing functional groups. Pt nanoparticles were electrochemically and homogeneously deposited on the ErGO surface. Field emission scanning electron microscopy (FE‐SEM), Raman spectroscopy, attenuated total reflectance‐fourier transform infrared spectroscopy (ATR‐FTIR), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV) were used to examine the surface morphology and electrocatalytic properties of the Pt‐ErGO nanocomposite film‐modified electrode surface. The fabricated nitrite sensor showed good electrochemical performance with two linear ranges; one from 5 to 100 µM (R2=0.9995) and the other from 100 to 1000 µM (R2=0.9972) and a detection limit of 0.22 µM. The proposed sensor was successfully applied for the detection of nitrite in tap water samples which proves performance of the Pt‐ErGO nanocomposite films.  相似文献   

7.
The graphene nanosheets/manganese oxide nanoparticles modified glassy carbon electrode (GC/GNSs/MnOx) was simply prepared by casting a thin film of GNSs on the GC electrode surface, followed by performing electrodeposition of MnOx at applied constant potential. The GC/GNSs/MnOx modified electrode shows high catalytic activity toward oxidation of L ‐cysteine. Hydrodynamic amperometry determination of L ‐cysteine gave linear responses over a concentration range up to 120 µM with a detection limit of 75 nM and sensitivity of 27 nA µM?1. The GC/GNSs/MnOx electrode appears to be a highly efficient platform for the development of sensitive, stable and reproducible L ‐cysteine electrochemical sensors.  相似文献   

8.
In the present work, the electrochemical oxidation of nitrite on carbon ceramic electrode (CCE) modified with multi‐walled carbon nanotubes (MWCNTs) was investigated. The modified electrode exhibited catalytic activity toward the electrooxidation of nitrite. Experimental parameters such as solution pH, scan rate, concentration of nitrite and nanotubes amount were studied. It was shown nitrite can be determined by differential pulse voltammetry (DPV) and hydrodynamic amperometry (HA) using the modified electrode. Under the optimized conditions the calibration plots are linear in the concentration ranges of 15‐220 and 50‐3000 μM with limit of detections of 4.74 and 35.8 μM for DPV and HA, respectively. The modified electrode was successfully applied for analysis of nitrite in spinach sample. The results were favorbly compared to those obtained by UV‐Visible spectrophotometric method. The results of the analysis suggest that the proposed method has promise for the routine determination of nitrite in the examined products.  相似文献   

9.
Electrochemical detection of nitrite was achieved via electrodeposition of gold nanoparticles (AuNPs) onto glassy carbon electrodes, followed by 3‐mercaptopropionic acid (MPA) self‐assembly, enabling attachment of an iron(III) monoamino‐phthalocyanine (FeMAPc) catalyst via amide bond formation. The use of scanning electron microscopy, energy dispersive X‐ray spectroscopy and ultraviolet‐visible spectroscopy realised surface characterisation while cyclic voltammetry and electrochemical impedance spectroscopy techniques were applied for electrochemical interrogation. The electrochemical behaviour of nitrite at the bare (GCE), AuNPs/GCE, FeMAPc/GCE and FeMAPc‐MPA/AuNPs/GCE was further scrutinised using differential pulse voltammetry in phosphate buffer solution (0.1 M PBS, pH 5.8). Overall the FeMAPc‐MPA/AuNPs/GCE resulted in sensitivity 14.5 nA/µM, which was double that of AuNPs/GCE, 2.4 times FeMAPc/GCE and 3.5 times the response at a bare GCE, with linear range 1.9 µM–2.04 mM (PBS, pH 5.8) and LOD 0.21 µM. An interference study revealed that the proposed sensor (FeMAPc‐MPA/AuNPs/GCE) exhibited a selective response in the presence of interfering anions and the analytical capability of the sensor was demonstrated via nitrite ion determination in real water samples.  相似文献   

10.
A modified electrode was fabricated by electrochemical formation of poly(vinylferrocene) on the multi-wall carbon nanotube-alizarin red S matrix covered glassy carbon electrode. A higher electrochemical activity was obtained to the electrocatalytic oxidation of dopamine. The electrode surface was characterized electrochemically and spectroscopically. Poly(vinylferrocene) (PVF) in electrode was used as an electron transfer mediator in the electrochemical oxidation of compounds due to its perfect reversible redox properties. Multi-wall carbon nanotubes (MWCNTs) / alizarin red S (ARS)–PVF electrode was used to the determination of dopamine in the presence of ascorbic acid in 0.1 M sulphate buffer solution at pH 7. The performance of the MWCNTs/ARS–PVF electrode was evaluated by DPV and amperometry.  相似文献   

11.
In this article, poly(1,2-diaminoanthraquinone) (pDAAQ) and poly(1,5-diaminonaphthalene) (pDAN) were electrochemically deposited layer by layer on a glassy carbon electrode (GCE) to generate pDAAQ/pDAN@GCE and pDAN/pDAAQ@GCE composite electrodes, respectively. The morphology and characteristics of the modified electrodes were investigated via electrochemical impedance spectroscopy)EIS), Fourier transform infrared spectroscopy (FT-IR), and scanning electron microscopy)SEM). The obtained results reveal the outstanding performance of the pDAN/pDAAQ@GCE electrode for electrochemical nitrite sensing where pDAAQ plays a vital role as the inner layer. Cyclic voltammetry (CV), linear sweep voltammetry (LSV), and differential pulse voltammetry (DPV) measurements revealed that the oxidation peak current of nitrite was proportional to its concentration. The best LSV results were obtained in a concentration range of 10–150 μM, with a limit of detection of 1.2 μM. Furthermore, the pDAN/pDAAQ@GCE composite electrode was used to determine nitrite ions in real water samples with good results.  相似文献   

12.
In the present paper, the electrochemical reduction of nitrite at a hemoglobin modified pencil lead electrode (Hb/PLE) is described. The electrochemical properties of nitrite were studied by cyclic voltammetry and chronoamperometry. Results showed that the hemoglobin film has an excellent electrochemical activity towards the reduction of nitrite. By using voltammetric and chronoamperometric methods, α, nα and n were calculated. Then the ability of the electrode for nitrite determination was investigated using differential pulse voltammetry. The electrocatalytic reduction peak currents were found to be linear with the nitrite concentration in the range from 10 to 220 µM with a detection limit of 5 µM. The relative standard deviation is 2 % for 3 successive determinations of a 100 µM nitrite solution. This modified electrode was successfully used for the detection of low amounts of NO2? in spinach sample and a spiked sample of tap water.  相似文献   

13.
This study describes the development, electrochemical characterization and utilization of 8,9‐dihydroxy‐7‐methyl‐12H‐benzothiazolo [2,3‐b]quinazolin‐12‐one (DMBQ)/ZnO nanoparticles (ZnO/Nps)‐carbon paste electrode (DMBQ/ZnO/NPs/CPE) as a modified sensor for the electrocatalytic determination of cysteine (Cys) in the presence of folic acid (FA). ZnO/NPs was synthesized and characterized by X‐ray diffraction (XRD) method. The prepared DMBQ/ZnO/NPs/CPE was developed as a highly sensitive voltammetric sensor for determination of Cys in the presence of FA in real samples. Square wave voltammetry (SWV) of Cys exhibited linear dynamic range with a detection limit (3σ) of 0.05 µmol/L.  相似文献   

14.
A multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs‐CHT/GCE) has been used for simultaneous determination of paracetamol (PAR) and uric acid (UA). The measurements were carried out using differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA). DPV measurements showed a linear relationship between oxidation peak current and concentration of PAR and UA in phosphate buffer (pH 7) over the concentration range 2 µM to 250 µM, and 10 µM to 400 µM, respectively. The analytical performance of this sensor has been evaluated for detection of PAR and UA in human serum and human urine with satisfactory results.  相似文献   

15.
In this work, we synthesized tantalum (Ta) nanoclusters on carbon black (Ta/CB) via simple electrodeposition in non-aqueous solvent, acetonitrile (ACN) at ambient temperature. Transmission electron microscopy (TEM) images showed that the electrodeposited Ta nanoclusters consisted of tiny Ta nanoparticles. X-ray photoelectron spectroscopy (XPS) result represented that the outermost Ta formed the native oxide on Ta/CB due to its ambient exposure to air. Electrochemical catalytic properties of prepared Ta/CB on glassy carbon electrode (Ta/CB/GC) were investigated toward reductions of oxygen and hydrogen peroxide, and oxidations of ascorbic acid and dopamine. For oxygen reduction reaction (ORR) in acid, Ta/CB/GC represented a decent electrocatalytic performance which was better or comparable to bare Pt. The operational stability in acidic condition was maintained up to 500 repetitive potential cycles presumably due to the protective native Ta oxide layer. Ta/CB/GC also showed high amperometric sensitivity (4.5 (±0.16) mA mM−1 cm−2, n = 5) for reduction of hydrogen peroxide in 0.1 M phosphate buffer solution (PBS, pH 7.4). In addition, Ta/CB/GC was demonstrated for the possibility of simultaneous detection of ascorbic acid and dopamine using differential pulse voltammetry (DPV).  相似文献   

16.
ABSTRACT

The rapid electrochemical determination of Aceclofenac (ACF) has been employed by cyclic voltammetry (CV), differential pulse voltammetry (DPV) using developed OH-functionalised multiwalled carbon nanotube carbon paste electrode (OH-MWCNT/CPE). Modified electrode was characterised by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDAX), X-ray diffraction spectroscopy (XRD), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The ACF exhibits two oxidation peaks at +0.4 V, +0.66 V and one reduction peak at +0.3 V. The active surface area of the bare carbon paste electrode (BCPE) and modified electrode have been characterised by using K3[Fe(CN)6] solution containing 0.1 M KCl. In DPV mode, variation of ACF gave the limit of detection (LOD = 3s/m) 0.246 μM over the concentration range 1.0 to 190.0 μM (R2 = 0.9994). The developed electrode has good stability, reproducibility and could be successfully validated for the detection of ACF in pharmaceutical samples and biological fluids.  相似文献   

17.
Ye D  Luo L  Ding Y  Chen Q  Liu X 《The Analyst》2011,136(21):4563-4569
A novel nitrite sensor was fabricated based on a graphene/polypyrrole/chitosan nanocomposite film modified glassy carbon electrode. The nanocomposite film was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and Raman spectroscopy. The electron transfer behaviour of the modified electrodes was investigated in [Fe(CN)(6)](3-)/(4-) redox probe using cyclic voltammetry and electrochemical impedance spectroscopy. Differential pulse voltammetry and amperometry were used to study the electrochemical properties of the proposed sensor. Under optimum conditions, the sensor exhibited good reproducibility and stability for nitrite determination. Linear response was obtained in the range of 0.5-722 μM with a detection limit of 0.1 μM (S/N = 3) for nitrite determination.  相似文献   

18.
An electrochemical sensor was prepared using Au nanoparticles and reduced graphene successfully decorated on the glassy carbon electrode (Au/RGO/GCE) through an electrochemical method which was applied to detect Sunset Yellow (SY). The as-prepared electrode was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), atomic force microscopy (AFM) and electrochemical measurements. The results of cyclic voltammetry (CV) proved that Au/RGO/GCE had the highest catalytic activity for the oxidation of SY as compared with GCE, Au/GCE, and RGO/GCE. Differential pulse voltammetry (DPV) showed that the linear calibration curves for SY on Au/RGO/GCE in the range of 0.002 μM–109.14 μM, and the detection limit was estimated to be 2 nM (S/N = 3). These results suggested that the obtained Au/RGO/GCE was applied to detect SY with high sensitivity, low detection limit and good stability, which provided a promising future for the development of portable sensor in food additives.  相似文献   

19.
Bismuth nanostructure‐carbon ionic liquid electrode has been employed for sensitive determination of cysteine (Cys). Bismuth nanostructure was incorporated into the carbon ionic liquid electrode (CILE) and applied for determination of cysteine. An interaction was taking place between bismuth nanostructure and the thiol group of cysteine. The bismuth cysteinate complex oxidation potential occurred at more negative potential compared to the cysteine oxidation peak obtained at bare carbon ionic liquid electrode (CILE). Square wave voltammetry (SWV) was used for the determination of the cysteine and satisfactory results were obtained. The calibration curve was linear in the concentration range of 1 to 500 µM and 0.5–2 mM of Cys. A low detection limit of 0.5 µM was achieved for Cys. The electrode showed a good selectivity for determination of cysteine in the presence of other amino acids. The proposed electrode was satisfactory applied for the determination of cysteine in human serum plasma sample.  相似文献   

20.
《Electroanalysis》2018,30(3):571-582
The present study deals with the development of an electrochemical sensor for quantitative determination of Bezafibrate (BZF) based on carbon nanofibers/polyaniline/platinum nanoparticles modified carbon paste electrode (CNF/PANI/Pt/CPE). BZF is a fibric acid derivative and is used largely in the treatment of lipid disorders. The nanocomposite was synthesized by in situ polymerization of aniline using ammonium persulphate and platinum nanoparticles were uniformly decorated on the CNF/PANI surface by reducing hexachloroplatinic acid using sodium borohydride. The electrochemical response of BZF at CNF/PANI/Pt/CPE was studied using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The above study resulted into significant improvement of the electrochemical signal towards the oxidation of BZF, revealing that the oxidation process is highly favorable at the surface of modified electrode. The anodic peak current Ip (μA) is found to be linearly dependent on BZF concentration in the range of 0.025 μM to 100 μM with a detection limit of 2.46 nM. The practical analytical utilities of the sensor were investigated by performing the experiments on synthetic pharmaceutical formulations, human blood serum and urine samples which offered good recovery, suggesting the high efficacy and authenticity of CNF/PANI/Pt/CPE sensor for BZF determination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号