1.
范鹏飞  于洁  杨鑫  屠娟  郭霞生  黄品同  章东 《中国物理 B》2017,26(5):54301-054301
High intensity focused ultrasound(HIFU) has shown a great promise in noninvasive cancer therapy. The impact of acoustic cavitation on the lesion formation induced by HIFU is investigated both experimentally and theoretically in transparent protein-containing gel and ex vivo liver tissue samples. A numerical model that accounts for nonlinear acoustic propagation and heat transfer is used to simulate the lesion formation induced by the thermal effect. The results showed that lesions could be induced in the samples exposed to HIFU with various acoustic pressures and pulse lengths. The measured areas of lesions formed in the lateral direction were comparable to the simulated results, while much larger discrepancy was observed between the experimental and simulated data for the areas of longitudinal lesion cross-section. Meanwhile,a series of stripe-wiped-off B-mode pictures were obtained by using a special imaging processing method so that HIFUinduced cavitation bubble activities could be monitored in real-time and quantitatively analyzed as the functions of acoustic pressure and pulse length. The results indicated that, unlike the lateral area of HIFU-induced lesion that was less affected by the cavitation activity, the longitudinal cross-section of HIFU-induced lesion was significantly influenced by the generation of cavitation bubbles through the temperature elevation resulting from HIFU exposures. Therefore, considering the clinical safety in HIFU treatments, more attention should be paid on the lesion formation in the longitudinal direction to avoid uncontrollable variation resulting from HIFU-induced cavitation activity.  相似文献   

2.
The classical "Bio Heat Transfer Equation (BHTE)" model is adapted to take into account the effects of oscillating microbubbles that occur naturally in the tissue during high-intensity focused ultrasound (HIFU) treatment. First, the Gilmore-Akulichev model is used to quantify the acoustic pressure scattered by microbubbles submitted to HIFU. Because this scattered pressure is not monochromatic, the concept of harmonic attenuation is introduced and a global attenuation coefficient is estimated for bubble-filled tissues. The first results show that this global attenuation coefficient varies significantly with respect to several parameters such as the frequency and the density of microbubbles in the medium, but also with respect to the incident acoustic pressure which thus becomes a transcendental function. Under these conditions, a layer-by-layer modeling, in the direction of propagation, is proposed to calculate the ultrasonic beam. Finally, the BHTE is solved and the HIFU-induced lesions are estimated by the calculation of the thermal dose. Using this model, it can be observed first that, when the firing power increases, the lesion develops clearly in the direction of the transducer, with a shape agreeing with in vivo experimentation. Next, it is observed that the lesion can be significantly modified in size and position, if an interface (skin or inner wall) is simulated as a zone with multiple cavitation nuclei. With a firing power increase, it is also shown how a secondary lesion can appear at the interface and how, beyond a certain threshold, this lesion develops at the main lesion expense. Finally, a better in-depth homogeneity of lesions is observed when the acoustic frequency of HIFU is increased.  相似文献   

3.
为满足高强度聚焦超声(HIFU)治疗对组织损伤均匀性和高效性的需求,理论及实验研究了连续扫描模式下HIFU沿螺旋扫描路径形成的组织损伤。基于Khokhlov-Zabolotskaya-Kuznetsov方程和生物传热方程建立了声热耦合模型,数值模拟了螺旋路径栅格距离为3 mm和4 mm时不同扫描速度下HIFU辐照体模的温度场和组织损伤分布,并采用凝胶体模进行了实验验证。结果表明,采用连续螺旋模式可以使热扩散均匀化,产生分布均匀的热损伤;选择适当的栅格距离和扫描速度,发挥螺旋路径内外圈热扩散的相互影响,可以产生大范围的整体性的热损伤,同时提高治疗效率。本文工作对优化HIFU治疗效果具有指导意义。   相似文献   

4.
球形集声器在生物组织中形成的组织损伤   总被引:2,自引:0,他引:2       下载免费PDF全文
耿昊  范庭波  张喆  屠娟  郭霞生  李发琪  章东 《物理学报》2014,63(4):44301-044301
球形集声器可在亚波长焦域内形成高强度声压,在高强度聚焦超声治疗中具有潜在应用前景.本文结合非线性声传播理论及生物传热学理论,研究球形集声器在生物组织中形成的组织损伤.实验中采用430 kHz,内径为240 mm的球形集声器对肝组织作用,结果表明:集声器表面声压为53 kPa时作用2 s,可以形成小于波长尺度的组织损伤.理论计算结果与实验结果符合得较好,并且理论模型可优化球形集声器的开口孔径.研究结果表明,球形集声器可应用于肿瘤的精细超声治疗.  相似文献   

5.
Zhong H  Wan M  Jiang Y  Wang S 《Ultrasonics》2006,44(Z1):e285-e288
High intensity focused ultrasound (HIFU) is an effective technique for noninvasive local creating coagulative necrotic lesions in deep target volumes without damage to the overlaying or surrounding tissues. It is very important to detect and evaluate lesions generated by HIFU during treatment procedures. This study describes the development of several differential ultrasonic imaging techniques to characterize lesions based on estimation of relative changes in tissue properties derived from backscattered RF data. A single, spherical HIFU transducer was used to produce lesions in soft tissues. The RF signals were recorded as outputs from a modified diagnostic ultrasound system. After some preprocessing, the integrated backscatter values, which can be used as an indicator of the microstructure and backscattering property of tissues, were calculated before and after HIFU treatment. The differential integrated backscatter values were subsequently used to form images revealing the lesion areas. The differential attenuation imaging with the same RF data was also performed, which has been proposed by a few researchers. The results of the differential integrated backscatter imaging were compared with that of the differential attenuation imaging and the former method offers some advantages over the latter method. The two methods above are both based on spectrum analysis and would spend much computational time. Therefore, some simple digital differential imaging methods, including absolute difference (AD), sum absolute differences (SAD), and sum squared differences (SSD) algorithms, were also proposed to detect HIFU-induced lesions. However, these methods cannot provide the information of the degree of tissue damage. Experiments in vitro bovine muscle and liver validated the method of differential integrated backscatter imaging for the characterization of HIFU-induced lesions. And the AD, SAD, and SSD algorithms can be implemented in real-time during HIFU therapy to visualize the lesions.  相似文献   

6.
Nowadays, both thermal and mechanical ablation techniques of HIFU associated with cavitation have been developed for noninvasive treatment. A specific challenge for the successful clinical implementation of HIFU is to achieve real-time imaging for the evaluation and determination of therapy outcomes such as necrosis or homogenization. Ultrasound Nakagami-m parametric imaging highlights the degrading shadowing effects of bubbles and can be used for tissue characterization. The aim of this study is to investigate the performance of Nakagami-m parametric imaging for evaluating and differentiating thermal coagulation and cavitation erosion induced by HIFU. Lesions were induced in basic bovine serum albumin (BSA) phantoms and ex vivo porcine livers using a 1.6 MHz single-element transducer. Thermal and mechanical lesions induced by two types of HIFU sequences respectively were evaluated using Nakagami-m parametric imaging and ultrasound B-mode imaging. The lesion sizes estimated using Nakagami-m parametric imaging technique were all closer to the actual sizes than those of B-mode imaging. The p-value obtained from the t-test between the mean m values of thermal coagulation and cavitation erosion was smaller than 0.05, demonstrating that the m values of thermal lesions were significantly different from that of mechanical lesions, which was confirmed by ex vivo experiments and histologic examination showed that different changes result from HIFU exposure, one of tissue dehydration resulting from the thermal effect, and the other of tissue homogenate resulting from mechanical effect. This study demonstrated that Nakagami-m parametric imaging is a potential real-time imaging technique for evaluating and differentiating thermal coagulation and cavitation erosion.  相似文献   

7.
The feasibility that temperature field measurements in vitro as an alternative way to characterize the high intensity focused ultrasound (HIFU) field used in therapeutic applications has been explored in a phantom study. Thermocouples (copper-constantan, diameter 0.125 mm) are embedded in a phantom filled with tissue mimicking material that simulates the thermal and acoustic properties of soft-tissue. The temperature rises as a function of ultrasound exposure time near the focus of a HIFU transducer (1.1 MHz, active radius a = 32 mm, geometric focal length = 62 mm) of various acoustic powers up to 30 W are measured and compared with predicted values using a simple nonlinear Gaussian model. The experimental results can be explained well by the model if no acoustic cavitation takes place. When the acoustic power become higher (>5 W) and the local temperature elevation >15 °C and the local temperature is >40 °C at the focal point, cavitation vapor bubbles appear. The presence of the cavitation bubbles may increase the temperature rise rate initially. The bubble aggregates may form along the beam axis under sonication and then eventually makes the temperature elevation reach a saturated value. When acoustic cavitation occurs, the bubble-assisted enhancement of the initial temperature rise (exposure time t < 2 s) can still be predicted by the theory.  相似文献   

8.
郭各朴  宿慧丹  丁鹤平  马青玉 《物理学报》2017,66(16):164301-164301
作为一种对正常组织无损伤且不易引起癌细胞转移的非入侵肿瘤治疗手段,高强度聚焦超声(HIFU)治疗过程中焦域的温度监测是实现剂量精准控制的关键.本文基于生物组织的温度-电阻抗的关系,将电阻抗层析成像(EIT)和HIFU治疗相结合,提出了一种利用组织焦平面的表面电压实现电阻抗重构的检测技术.建立了HIFU治疗和EIT综合系统模型,在考虑组织的声吸收条件下,对三维Helmholtz方程在柱坐标下的声场计算进行了二维简化,并引入Pennes生物热传导方程来计算HIFU焦域的声压和温升分布特性;引入生物组织的温度-电阻抗关系,基于麦克斯韦电磁场理论,建立了具有温度分布HIFU焦域的电流和电压计算模型,利用恒流注入的边界条件实现电场计算,获得焦平面的表面电压分布.在数值计算中,利用实验聚焦换能器参数,模拟了在固定声功率下组织焦域的声场和温度场分布,以及中心和偏心聚焦条件下不同治疗时刻的电导率分布;然后通过对称电极的循环电流注入,计算了组织模型焦平面内的电流密度和电势分布,获得了焦平面圆周分布的表面电极电压;进一步采用修正的牛顿-拉夫逊算法,利用32×32的表面电极电压实现了焦平面内电导率分布的重建.结果表明,基于温度-电阻抗关系的EIT电导率重建技术不但能准确定位HIFU焦域中心,还能恢复HIFU治疗中焦域的温度分布,证明了EIT用于HIFU治疗中温度监测的可行性,为其疗效评估和剂量控制提供了一种无创电阻抗测量和成像新方法.  相似文献   

9.
A HIFU sequence with extremely short pulse duration and high pulse repetition frequency can achieve thermal ablation at a low acoustic power using inertial cavitation. Because of its cavitation-dependent property, the therapeutic outcome is unreliable when the treatment zone lacks cavitation nuclei. To overcome this intrinsic limitation, we introduced perfluorocarbon nanodroplets as extra cavitation nuclei into short-pulsed HIFU-mediated thermal ablation. Two types of nanodroplets were used with perfluorohexane (PFH) as the core material coated with bovine serum albumin (BSA) or an anionic fluorosurfactant (FS) to demonstrate the feasibility of this study. The thermal ablation process was recorded by high-speed photography. The inertial cavitation activity during the ablation was revealed by sonoluminescence (SL). The high-speed photography results show that the thermal ablation volume increased by ∼643% and 596% with BSA-PFH and FS-PFH, respectively, than the short-pulsed HIFU alone at an acoustic power of 19.5 W. Using nanodroplets, much larger ablation volumes were created even at a much lower acoustic power. Meanwhile, the treatment time for ablating a desired volume significantly reduced in the presence of nanodroplets. Moreover, by adjusting the treatment time, lesion migration towards the HIFU transducer could also be avoided. The SL results show that the thermal lesion shape was significantly dependent on the inertial cavitation in this short-pulsed HIFU-mediated thermal ablation. The inertial cavitation activity became more predictable by using nanodroplets. Therefore, the introduction of PFH nanodroplets as extra cavitation nuclei made the short-pulsed HIFU thermal ablation more efficient by increasing the ablation volume and speed, and more controllable by reducing the acoustic power and preventing lesion migration.  相似文献   

10.
孙健明  于洁  郭霞生  章东 《物理学报》2013,62(5):54301-054301
在高强度聚焦超声(high intensity focused ultrasound, HIFU) 的研究中, 生物组织的衰减和色散性质会对声能量的空间分布产生影响. 本文提出应用分数导数修正非线性Khokhlov-Zabolotskaya-Kuznetsov (KZK)方程, 研究生物组织中非线性HIFU声场. 对三种生物仿体的衰减和声速色散的理论实验研究表明分数导数应用的可行性, 在此基础上通过数值仿真分析研究了衰减及声速随频率的变化对HIFU焦域分布的影响. 研究结果表明, 在计算强非线性聚焦超声时, 由于高次谐波的强色散作用, 引入分数导数来解决生物组织特殊的衰减以及色散问题可进一步提高HIFU治疗的安全性. 关键词: 分数导数 声衰减 色散 高强度聚焦超声  相似文献   

11.
宿慧丹  郭各朴  马青玉  屠娟  章东 《中国物理 B》2017,26(5):54302-054302
As an effective therapeutic modality, high-intensity focused ultrasound(HIFU) can destroy tumour tissues by thermocoagulation with less metastasis, but it is still limited by inaccurate non-invasive temperature monitoring and efficacy evaluation. A model of electrical impedance measurement during HIFU therapy was established using the temperatureimpedance relationship. Based on the simulations of acoustic pressure, temperature, and electrical conductivity, the impedance of the phantom was calculated and experimentally demonstrated for different values of acoustic power values and treatment time. We proved that the relative impedance variation(RIV) increases linearly with the increasing treatment time at a fixed acoustic power, and the relative impedance variation rate shows a linear relationship with the acoustic power.The RIV and treatment time required for HIFU treatment efficacy are inversely proportional to the acoustic power and the square of acoustic power, respectively. The favourable results suggest that RIV can be used as an efficient indicator for noninvasive temperature monitoring and efficacy evaluation and may provide new strategy for accurate dose control of HIFU therapy.  相似文献   

12.
欧阳灵  刘晓宙  刘杰惠  龚秀芬 《物理学报》2014,63(10):104304-104304
纳米力学方法适用于具有离散特性的材料.利用纳米力学方法,得出声波在多层皮肤组织中的波动方程.分别改变黑素瘤皮肤的泊松比、黑素瘤侵袭厚度(Breslow深度)、节间距离,计算多层皮肤结构模型对垂直入射纵声波的反射系数.同时计算了声速和声衰减系数随组织参数的变化.计算结果表明,可综合利用一定频率段内反射系数最小点数、声速和衰减系数的变化来表征正常皮肤和病变皮肤.  相似文献   

13.
The phase data of the photothermal signals measured at the surface of two-layer systems are interpreted in the framework of 3-D thermal wave propagation, taking into account the finite size of the heating spot and detection spot. In the first approach, concentric heating and detection spots are considered. In this configuration, information on the thermophysical properties of the surface layer is obtained in the range of intermediate and high modulation frequencies of heating. Additionally information on the thermal diffusivity of the subsurface material can be obtained in the limit of low modulation frequencies. Applying pump–probe offsets and controlled displacements between the excitation spot and detection spot provides the possibility of localizing heat sources. On the basis of numerical simulations using displacement distances from the millimeter to the micrometer range, the scaling of the thermal localization of hot spots from macroscopic to microscopic is studied with respect to experimental parameters, such as the heating and detection spot size, and the optimal range of the heating modulation frequencies.  相似文献   

14.
高强度聚焦超声(HIFU)治疗中的驱动电功率对治疗效率起着非常关键的作用,驱动电功率控制的精准性势必会影响治疗的效率和安全性。前期研究表明:HIFU治疗过程中焦域瞬态物理特性的变化会导致换能器的负载阻抗发生变化,进而影响HIFU驱动电功率,但驱动电功率与焦域瞬态物理特性之间的影响关系及规律尚不明确。该文基于电压、电流传感器、空化检测探头和温度传感器等器件,构建了一种HIFU治疗中驱动电功率实时监测及焦域声空化、温度检测系统。基于该实验研究系统,以离体牛心组织作为HIFU辐照对象,分别研究了HIFU焦域温度变化、声空化及组织损伤与驱动电功率之间的变化关系及规律。研究结果表明:当焦域温度升高时,驱动电功率缓慢上升,驱动电功率与温度变化有良好的相关性;当空化产生时,驱动电功率出现明显的波动;当组织出现损伤时,驱动电功率呈陡然下降的变化。三种情景下,驱动电功率变化有明显区别,这有望为区分HIFU治疗过程中焦域处发生损伤和空化以及实时监测靶组织损伤程度提供一种新的解决方案。  相似文献   

15.
Broadband scanning acoustic microscopy (SAM) has been used to investigate the mechanical properties of sections of tissue with a resolution of around 8 microns. The work reported here extends these results by reporting the frequency dependence of the attenuation coefficient from 100-500 MHz. A discussion of the theory of the measurements is presented. The scanning laser acoustic microscope (SLAM) is used to characterize similar tissue sections at 100 MHz. The data obtained with the two forms of acoustic microscopy are compared with results from the literature.  相似文献   

16.
Experimental studies of thermal effects in high-intensity focused ultrasound (HIFU) procedures are often performed with the aid of fine wire thermocouples positioned within tissue phantoms. Thermocouple measurements are subject to several types of error which must be accounted for before reliable inferences can be made on the basis of the measurements. Thermocouple artifact due to viscous heating is one source of error. A second is the uncertainty regarding the position of the beam relative to the target location or the thermocouple junction, due to the error in positioning the beam at the junction. This paper presents a method for determining the location of the beam relative to a fixed pair of thermocouples. The localization technique reduces the uncertainty introduced by positioning errors associated with very narrow HIFU beams. The technique is presented in the context of an investigation into the effect of blood flow through large vessels on the efficacy of HIFU procedures targeted near the vessel. Application of the beam localization method allowed conclusions regarding the effects of blood flow to be drawn from previously inconclusive (because of localization uncertainties) data. Comparison of the position-adjusted transient temperature profiles for flow rates of 0 and 400 ml/min showed that blood flow can reduce temperature elevations by more than 10%, when the HIFU focus is within a 2 mm distance from the vessel wall. At acoustic power levels of 17.3 and 24.8 W there is a 20- to 70-fold decrease in thermal dose due to the convective cooling effect of blood flow, implying a shrinkage in lesion size. The beam-localization technique also revealed the level of thermocouple artifact as a function of sonication time, providing investigators with an indication of the quality of thermocouple data for a given exposure time. The maximum artifact was found to be double the measured temperature rise, during initial few seconds of sonication.  相似文献   

17.
微泡对高强度聚焦超声(HIFU)治疗具有增效作用,而HIFU治疗中不同声学条件下微泡对HIFU治疗焦域的影响尚不清楚。本文基于声传播方程、Yang-Church气泡运动方程、生物热传导方程、时域有限差分法(FDTD)、龙格-库塔(RK)法数值仿真研究输入功率、激励频率和气泡初始半径对HIFU在含气泡体模中形成焦域的影响,并利用含Sono Vue造影剂的仿组织体模研究进行实验验证。结果表明,增大输入功率、气泡初始半径和升高激励频率均可增大焦域,随着输入功率的增大,焦域形状可能发生变化,而随着激励频率升高和气泡初始半径的增大,焦域会向远离换能器的方向移动。  相似文献   

18.
Previous reported data from our laboratory demonstrated the temperature dependence of propagation speed and attenuation of canine tissue in vitro at discrete temperatures ranging from 25 to 95 degrees C. However, concerns were raised regarding heating the same tissue specimen over the entire temperature range, a process that may introduce irreversible and, presumably, cumulative tissue degradation. In this paper propagation speed and attenuation vs temperature are measured using multiple groups of samples, each group heated to a different temperature. Sample thicknesses are measured directly using a technique that uses both transmitted and reflected ultrasound pulses. Results obtained using 3 and 5 MHz center frequencies demonstrate a propagation speed elevation of around 20 m/s in the 22-60 degrees C range, and a decrease of 15 m/s in the 60-90 degrees C range, in agreement with previous results where the same specimens were subjected to the entire temperature range. However, sound speed results reported here are slightly higher than those reported previously, probably due to more accurate measurements of sample thickness in the present experiments. Results also demonstrate that while the propagation speed varies with temperature, it is not a function of tissue coagulation. In contrast, the attenuation coefficient depends on both tissue coagulation effects and temperature elevation.  相似文献   

19.
高强度聚焦超声(HIFU)是一种无创的热消融疗法,为保证其安全性和有效性,需要一种精度高、速度快的测温方法在其治疗过程中对温度进行监控.基于质子共振频率位移(PRFS)的磁共振温度成像(MRT)对温度具有较高的灵敏度,且与温度具有良好的线性关系,因此常被用于引导HIFU治疗.然而在实际应用中,HIFU治疗的最大隐患在于可能造成表皮灼伤,并且灼伤区域可能与焦点区域相隔较远.因此MRT的监控范围十分重要.本文基于三维回波平移成像序列,结合可控混叠的空间并行成像技术,实现了时间分辨率为3 s的快速三维温度成像.为了验证该方法的精度,本文首先设计了仿体降温实验,利用光纤温度计验证回波平移序列测温的准确度和精确度.然后在室温条件下扫描离体猪肉组织,对比加速前后的MRT的测温精确度.在HIFU加热条件下扫描离体猪肉组织,对比加速前后的MRT的测温准确度.结果显示,本文提出的方法可以在3 s内完成三维温度精准测量,对于HIFU治疗的安全监控具有重要意义.  相似文献   

20.
To produce deep-seated surgical lesions using ultrasound requires high power and intensity levels at the target sites. Conventionally, large transducers are used which require big apertures and so are generally suitable only for extra-corporeal access. Such transducers also result in strong off-focus maxima, where the resulting hot spots can destroy normal tissue whilst deep-seated large tissue volumes are being ablated. This paper describes a new approach in which it is proposed that multiple probes are used simultaneously, each at a relatively low power, to result in an overlapping focused region of high temperature without strong off-focus hot spots. Robotic techniques could be used to move the individual probes in coordination to sweep out the desired region of tissue ablation. Simulation and planning are the key to quality prediction for high intensity focused ultrasound (HIFU). Simplified two-dimensional and three-dimensional models of HIFU probes have been developed to study the characteristics of various multi-probe configurations. Preliminary simulation results show that the multi-probe system can be arranged successfully to minimise off-focus hot spots. Experimental results are presented which validate the modality and confirm this positive finding. Further prediction studies and planning will be necessary to achieve the most appropriate desired treatment, by varying the pulse duration and spacing.  相似文献   