共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
To reduce temperature sensitivity of the fibre Bragg grating (FBG) chemical sensor, a simple method is proposed by measuring the peak wavelength difference between an etched FBG and an un-etched one in an optical fibre. Thermal characteristics and chemical sensitivity of the sensor are experimentally investigated. The experimental results indicate that the etched FBG and the rest one have almost the same thermal response, and concentration changes of the surrounding chemical solutions can be detected by measuring the peak wavelength difference between them. The sensor has been used to measure the concentrations of propylene glycol solutions and sugar solutions, and it could detect 0.7% and 0.45% concentration changes for them with an optical spectrum analyser in resolution of 10pm. 相似文献
5.
为了实现单一光纤光栅对压强精确测量,设计了一种温度不敏感的光纤布拉格高压传感器。对该传感器的温度特性及压强响应特性进行研究。给出了该传感器的结构及封装方法。从理论上分析了该传感器的温度去敏原理,推导了该压强传感器的光纤布拉格光栅中心波长与压强的关系,得到了该传感器的压强响应灵敏度的解析表达。通过实验分析传感器的温度特性及压强响应。实验结果表明,在21℃~260.8℃的范围内,实现了温度补偿,平均波长漂移量为0.75 pm/℃,在0~44 MPa的范围内,获得了-0.054 8 nm/MPa的压强响应灵敏度,是裸光纤布拉格光栅压力响应灵敏度的18.27倍。该传感器的压强响应具有很好的线性和重复性,实验值与理论值吻合得很好,该传感器能够通过一只光纤布拉格光栅实现压强的精确测量。 相似文献
6.
7.
高灵敏度的光纤光栅压强传感器 总被引:15,自引:0,他引:15
基于光纤布拉格光栅传感模型 ,提出了一种等强度梁与波纹管相结合的高灵敏度的光纤布拉格光栅压强传感器 ,推导了光纤布拉格光栅反射波中心波长相对偏移量与压强之间的解析关系式 ,从理论和实验上给出了压强灵敏度系数。该传感器的理论和实验压强灵敏度系数分别是 1.4 76× 10 -2 MPa-1、1.35× 10 -2 MPa-1,是裸光纤光栅的 74 5 5倍和 6 80 8倍 ,理论值与实验值吻合得很好。同时指出通过调节等强度梁和波纹管的参量 ,可以将该传感器的压强灵敏度系数做得很高 ,直至破坏了光纤布拉格光栅。 相似文献
8.
双悬臂梁光纤Bragg光栅应力传感器 总被引:1,自引:3,他引:1
报道了一种新颖的光纤Bragg光栅应力传感器.理论分析和实验证明了这种传感器Brrag光栅中心波长随应力变化的线性工作区.将光纤Bragg光栅贴于双悬梁的梁端面,在双悬梁的自由端部施加载荷,对光纤Bragg光栅的应力响应特性测试.当所加载荷为300 g时,光纤Bragg光栅中心波长变化了0.156 nm.从实验上获得了-0.05 nm/N的应力响应灵敏度.该结构具有应力增敏作用,且应力响应的线性、重复性和迟滞性较好.应力响应灵敏度随着梁的大小以及材料的力学参量的改变而改变. 相似文献
9.
10.
11.
研制了光纤光栅弹簧管压力传感器,并与双边缘解调技术相结合搭建了基于边缘解调技术的光纤压力传感器检测系统,对传感器和解调器的性能进行了测试,给出了实验结果.压力灵敏度为0.33nm/MPa,解调系统线性拟合度为0.99977,系统压力测量分辨率可达0.01MPa. 相似文献
12.
In this paper, we present a Fiber-Bragg-Grating-based temperature sensor. The technique employs heterodyne detection using two Fiber Bragg Gratings. One of the gratings is used as a reference (local oscillator) and the second as a sensing arm. This sensor uses a Folded Mach-Zehnder interferometer. As the temperature changes, the Bragg wavelength of the FBG shifts. The heterodyne detection is used to detect the frequency difference between the reference and sensing signals that is caused by the temperature change. The dynamic range and sensitivity of the sensor were analyzed and presented. 相似文献
13.
14.
光纤光栅弹簧管压力传感器的压力和温度特性 总被引:14,自引:0,他引:14
本文利用弹簧管对于压力的机械放大作用,将弹簧管与光纤光栅悬臂梁调谐技术相结合,研制了一种新颖的光纤光栅弹簧管压力传感器,大大提高了光纤布喇格光栅对压力测量的灵敏度,压力灵敏度系数可达-1.79×10-4/MPa,比裸光栅提高了两个数量级,在0~12MPa的压力范围内,光纤布喇格光栅中心反射波长的改变与压力成良好的线性关系.同时由于悬臂梁热膨胀效应的影响,光纤光栅的温度灵敏度提高为裸光栅的7倍. 相似文献
15.
提出并制作了一种基于多芯光纤与单模光纤错位构成的马赫-曾德尔干涉仪,将其与光纤布喇格光栅级联,形成的全光纤传感系统可实现横向压力和温度双参量同时测量.马赫-曾德尔干涉仪是利用多芯光纤和单模光纤的模场不匹配而发生模间干涉,当外界横向压力直接作用在多芯光纤内部光场,干涉仪具有较高的灵敏度.实验结果表明:马赫-曾德尔干涉仪压力灵敏度为28.57nm/(N·mm~(-1)),线性度为0.997,而光纤布喇格光栅在一定范围内对压力变化不敏感;马赫-曾德干涉仪和光纤布喇格光栅对温度变化都具有较高的线性度,温度灵敏度分别为56.1pm/℃和11.3pm/℃.对于分辨率为0.02nm的光谱仪,传感器可实现的压力和温度测量分辨率分别为7.0×10~(-4)N/mm和0.03℃.马赫-曾德尔干涉仪的透射谱和光纤布拉光栅的谐振峰对横向压力和温度的变化有不同的光谱响应,利用光谱仪对传感器的透射谱实时监测,方便地实现了压力与温度双参量的测量.该传感器结构简单,灵敏度高,可用于不同领域的压力传感. 相似文献
16.
报道了利用偶联技术封装光纤光栅压力传感器的新方案.通过采用特殊聚合物材料将光纤光栅封装于金属管中,并采用偶联材料分别与聚合物和光纤以化学键偶联的工艺,解决了由于有机弹性体聚合物的弹性模量(1.2×105 N/m2)与光纤光栅的弹性模量(7×1010 N/m2)相差很大,在压强较大时易导致光纤光栅与聚合物材料之间的撕裂滑脱问题,改善了光纤光栅压力响应特性.封装后的光纤光栅压力的线性测量范围为0.04 MPa~0.6 MPa,压力响应灵敏度为-4.48 nm/MPa,与裸光栅压力响应灵敏度-0.003063 nm/MPa相比,增敏了1463倍.利用实验中所使用光谱仪0.05 nm的分辨率,压强测量准确度为±0.01 MPa,线性度为0.9978. 相似文献
17.
基于虚拟仪器和可调谐激光技术的光纤光栅传感系统 总被引:4,自引:3,他引:1
提出了一种新颖的基于虚拟仪器(VI)和可调谐激光技术的光纤光栅(FBG)传感系统,利用可调谐激光对由光纤光栅组成的传感器阵列进行波长扫描,实现了多根光栅的复用准静态解调,并结合抖动技术和反馈环结构,使得探测信号在每一根传感光栅中心波长处过零,以提高系统在测定波长偏移时的分辨力。当反馈环工作在闭环状态下时,该系统还可对单根光栅实现动态跟踪锁定,实现单根光栅的动态解调。该传感系统的数据采集采用虚拟仪器技术,通过多通道同时输入输出实现了在线实时解调。实验采用了4根光栅组成传感阵列,获得了静态多根光栅小于1με和单根光栅动态频率10 Hz时3.3 n/εHz的解调分辨力,动态应变范围在850με。 相似文献
18.
单光纤光栅波谱展宽温度压力同时区分测量 总被引:10,自引:4,他引:6
报道了利用单光纤布拉格光栅反射波带宽展宽技术实现温度与压力同时区分测量的新方案。通过聚合物材料将光栅粘接于双孔悬臂梁非均匀应变区 ,在压力作用下悬臂梁带动光栅发生非均匀应变 ,使布拉格反射波波长漂移的同时带宽展宽 ,而温度变化仅引起反射波波长漂移。在 2 0~ 10 0℃和 0~ 7.8N的温度和压力测量范围内 ,温度测量精度± 1.1℃ ,压力测量精度± 0 .18N ,布拉格反射波中心波长漂移量和带宽展宽量随温度和压力的变化呈良好的线性关系 ,线性度均高于 99.6 %。多次测量表明 ,此方案的展宽波形稳定 ,重复性好。 相似文献
19.