共查询到17条相似文献,搜索用时 138 毫秒
1.
ICP-MS测定三种抗肿瘤中成药中铅镉汞砷含量 总被引:9,自引:0,他引:9
采用电感耦合等离子体-质谱(ICP-MS)法测定了三种抗肿瘤中成药(金克槐耳、华蟾素和复方苦参)中四种元素铅、镉、汞、砷的含量。结果显示,铅、镉、汞、砷四种元素在三种抗肿瘤中成药中的含量较低,均符合东南亚进口标准。其中金克槐耳中汞和砷含量略高于美国FAD药品与功能性食品要求标准,但仍符合其他标准。电感耦合等离子体-质谱法是测定中成药中铅、镉、汞、砷快速、准确的方法。 相似文献
2.
3.
4.
5.
6.
ICP-AES分析河蚌肉中14种微量元素 总被引:1,自引:0,他引:1
应用ICP-AES测定河蚌肉中14种微量元素,同时进行ICP-AES仪器工艺参数优化试验。结果表明:适当降低射频(RF)发生器功率和增加雾化器压力,有利于易电离元素(如K、Na元素)测试;适当增加RF功率和降低雾化器压力有利于中等易电离和难电离元素,如Cr、Cd等其他12种元素测试。样品提升量的改变,对各元素测试影响并不太大。元素测试的相关系数范围为0.9994—0.9999,检出限范围为0.3—18.5 ng.mL-1,回收率范围为93.6%—104.8%之间,RSD为8.0%。河蚌肉中含有丰富的矿物元素,如:K、Na、Ca、Mg及其他一些人体健康所必需的微量元素,如Mn、Fe、Cu、Zn、Ni、Cr。但过多食用时,应考虑有害元素Cd、As、Pb潜在的污染危险性,和一些微量元素的过量性问题。 相似文献
7.
8.
ICP-AES测定饮用水中5种重金属元素 总被引:5,自引:0,他引:5
应用电感耦合等离子体-原子发射光谱法(ICP-AES)直接测定饮用水中砷、镉、铬、汞和铅5种痕量重金属元素。为了降低光谱分析检出限,在水样品中加入一定体积的有机添加剂,以提高光谱的信背比。实验结果发现,当加入6%的正丙醇以后,光谱信背比增加幅度是最大的,元素砷、镉、铬、汞和铅的光谱信背比比无添加剂时分别提高了177.4%、45.2%、38.9%、354.7%和83.8%。定量分析结果表明,各元素的相对标准偏差(RSD)在4.5%—8.0%之间,回收率为96.7%—107.1%。 相似文献
9.
10.
11.
微波消解ICP-MS法测定中华白海豚额隆中微量元素及其含量特征分析 总被引:1,自引:0,他引:1
中华白海豚是我国一级保护动物,处于海洋食物链顶端,而重金属、持久性有机污染物等污染物易在其体内富集。额隆是鲸豚回声定位的重要部位,具有传导信号的作用。为探究中华白海豚额隆中微量元素的基线水平以及其组成的主要特征成分,研究采用微波消解电感耦合等离子体质谱(ICP-MS)法测定了中华白海豚额隆中V,Ni,Cr,Mn,Cu,As,Zn,Hg,Se,Cd和Pb 11种微量元素并对其含量进行特征分析。结果表明该方法具有良好的准确度和精密度,适合于中华白海豚额隆微量元素的测定分析。样品分析显示,额隆中11种微量元素整体含量水平不高,由于个体生理状况不同,同种元素含量在不同个体中存在差异;其平均含量从高到低排序依次为:ZnAsCuMnSeHgCrNiPbVCd,其中As作为非必需有毒微量元素,含量水平较高(1.158μg·g-1 ww),可能会对海豚产生生理毒害作用。Spearman相关性分析显示,As(r=0.733),Cd(r=0.615)和Hg(r=0.645)含量与海豚体长呈显著正相关性(p0.05),表明As,Cd和Hg三种元素可随海豚年龄增加而在额隆中富集;Cs与Ni呈正相关(p0.05),Mn与As呈负相关(p0.01),表明元素间也存在着一定的关联性。此外,主成分分析结果表明,V,Mn,Ni,Se,Cu和Hg为中华白海豚额隆主要特征微量元素。研究在国内首次使用微波消解ICP-MS法对中华白海豚额隆中微量元素进行研究,结合相关性分析和主成分分析,有效探究了中华白海豚额隆中微量元素的生物富集模式与含量特征,实验结果为研究中华白海豚额隆中微量元素基线水平提供了参考。 相似文献
12.
The liver, kidney and muscle samples from seven cetaceans were digested by microwave digestion, and trace elements amounts of V, Cd, Cu, Zn, As, Cr, Ni, Mn, Se, Hg and Pb were determined by inductively coupled plasma mass spectrometry (ICP-MS), and the health risk assessment for Zn, Cu, Cd, Hg, Se in the liver was conducted. The results of international lobster hepatopancreas standard (TORT-2) showed acceptable agreement with the certified values, and the relative standard deviation (RSD) of eleven kinds of trace elements were less than 3.54%, showing that the method is suitable for the determination of trace elements in cetaceans. The experimental results indicated that different tissues and organs of the dolphins had different trace elements, presenting the tissue specificity. There is a certain inter-species difference among different dolphins about the bioaccumulation ability of the trace elements. The distribution of trace elements in whales presented a certain regularity: the contents of most elements in liver, kidney were much higher than the contents of muscle tissues, Cu, Mn, Hg, Se, and Zn exhibit the higher concentrations in liver, while Cd was mainly accumulated in kidney. And according to the health risk assessment in liver, the exceeding standardrate of selenium and copper in seven kinds of whales was 100%, suggesting that these whales were suffering the contamination of trace elements. The experimental results is instructive to the study of trace elements in cetaceans, while this is the first report for the concentrations in organs of Striped dolphin, Bottlenose dolphin, Fraser's Dolphin and Risso's dolphin in China, it may provide us valuable data for the conservation of cetaceans. 相似文献
13.
ICP-MS法测定海洋鲸豚的微量元素及其健康风险评估 总被引:1,自引:0,他引:1
建立了微波消解电感耦合等离子质谱(ICP-MS)法测定珠江口水域搁浅的七种不同鲸豚肌肉,肝脏和肾脏中的V,Cr,Cu,Zn,As,Cd,Ni,Mn,Se,Hg,Pb等11种微量元素的分析方法,并对七种鲸豚肝脏中的Zn,Cu,Cd,Hg,Se五种元素进行了健康风险评估。采用国际标准物质TORT-2进行测定,结果显示,11种微量元素的测定值均在保证值和标准值范围内,其相对标准偏差(RSD)均小于3.54%,表明该方法具有良好的准确度和精密度,适合于鲸豚体内微量元素的测定。数据分析表明,相同海豚不同组织器官微量元素含量具有显著差异,呈现组织特异性;不同种海豚对微量元素的富集能力存在一定的种间差异性。微量元素在鲸豚体内的分布呈现一定的规律性:大部分元素在肝、肾脏中的含量远高于在肌肉中的含量,Cu,Mn,Hg,Se,Zn等元素主要在肝脏中积累,而Cd主要在肾脏中积累。健康风险评估结果显示,Se和Cu在7头鲸豚肝脏中均超标,超标率达100%,提示这七种鲸豚均受到了一定程度的微量元素污染。实验结果为使用微波消解ICP-MS法研究鲸豚微量元素提供了指导,对国内条纹原海豚,瓶鼻海豚,沙捞越海豚,灰海豚脏器微量元素进行了研究报道,以期为鲸豚保育工作提供宝贵数据。 相似文献
14.
15.
动态反应池电感耦合等离子体质谱法同时测定彩色卷烟纸中7种重金属 总被引:2,自引:0,他引:2
采用微波消解前处理样品,建立动态反应池电感耦合等离子体质谱法同时测定彩色卷烟纸中的Cr、Ni、As、Se、Cd、Hg和Pb7种重金属含量。该方法以钇(Y)作为内标补偿基体效应,采用动态反应池模式消除Cr、Ni、Se的质谱干扰,用茶叶标准物质对方法准确性进行校正。该方法相对标准偏差均小于10%、回收率为86.6%—120.9%、检出限为2.94—70.05ng/L,该方法操作简单、分析速度快、灵敏度高、准确度好,能快速、准确测定彩色卷烟纸中重金属。 相似文献
16.
采用HNO3-H2O2的消解体系,应用电感耦合等离子体质谱法(ICP-MS)同时测定枳壳中Pb,Cd,As,Hg,Cu五种微量重金属元素含量,方法对试样中各元素测定的相对标准偏差(RSD)为3.6%~5.4%,加标回收率为85%~109%,快速、准确、灵敏度高,适用于枳壳中五种最金属元素含量的测定.同时考察了微波提取、超声波提取和传统煎煮法对枳壳中五种重金属元素溶出的情况.结果表明:微波提取液中As和Pb的含量比超声提墩和煎煮提取的略低,三种不同提取方法的枳壳提取液中五种微量重金属元素的含量均低于<药用植物及制剂进出口绿色行业标准>的限量标准,而微波萃取法在有效成分的提取中具有快速,高效等特点,同时也是安全的. 相似文献