首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high‐repetition‐rate pump–probe experiment is presented, based on the asynchronous sampling approach. The low‐α mode at the synchrotron ANKA can be used for a time resolution down to the picosecond limit for the time‐domain sampling of the coherent THz emission as well as for hard X‐ray pump–probe experiments, which probe structural dynamics in the condensed phase. It is shown that a synchronization of better than 1 ps is achieved, and examples of phonon dynamics of semiconductors are presented.  相似文献   

2.
This paper presents the performance of a single‐photon‐counting hybrid pixel X‐ray detector with synchrotron radiation. The camera was evaluated with respect to time‐resolved experiments, namely pump–probe–probe experiments held at SOLEIL. The UFXC camera shows very good energy resolution of around 1.5 keV and allows the minimum threshold setting to be as low as 3 keV keeping the high‐count‐rate capabilities. Measurements of a synchrotron characteristic filling mode prove the proper separation of an isolated bunch of photons and the usability of the detector in time‐resolved experiments.  相似文献   

3.
Synchrotron radiation time structure is becoming a common tool for studying dynamic properties of materials. The main limitation is often the wide time domain the user would like to access with pump–probe experiments. In order to perform photoelectron spectroscopy experiments over time scales from milliseconds to picoseconds it is mandatory to measure the time at which each measured photoelectron was created. For this reason the usual CCD camera‐based two‐dimensional detection of electron energy analyzers has been replaced by a new delay‐line detector adapted to the time structure of the SOLEIL synchrotron radiation source. The new two‐dimensional delay‐line detector has a time resolution of 5 ns and was installed on a Scienta SES 2002 electron energy analyzer. The first application has been to characterize the time of flight of the photoemitted electrons as a function of their kinetic energy and the selected pass energy. By repeating the experiment as a function of the available pass energy and of the kinetic energy, a complete characterization of the analyzer behaviour in the time domain has been obtained. Even for kinetic energies as low as 10 eV at 2 eV pass energy, the time spread of the detected electrons is lower than 140 ns. These results and the time structure of the SOLEIL filling modes assure the possibility of performing pump–probe photoelectron spectroscopy experiments with the time resolution given by the SOLEIL pulse width, the best performance of the beamline and of the experimental station.  相似文献   

4.
X‐ray scattering experiments on femtosecond laser‐excited gold nanoparticle suspensions are presented. It is shown that the time‐resolved pump–probe technique using the X‐ray pulse structure at synchrotron sources is capable of resolving structural dynamics on the nanometer scale to high precision. The estimation of X‐ray flux density allows the projection of experiments on an X‐ray free‐electron laser probing single nanoparticles in a one‐shot exposure.  相似文献   

5.
The technical implementation of a multi‐MHz data acquisition scheme for laser–X‐ray pump–probe experiments with pulse limited temporal resolution (100 ps) is presented. Such techniques are very attractive to benefit from the high‐repetition rates of X‐ray pulses delivered from advanced synchrotron radiation sources. Exploiting a synchronized 3.9 MHz laser excitation source, experiments in 60‐bunch mode (7.8 MHz) at beamline P01 of the PETRA III storage ring are performed. Hereby molecular systems in liquid solutions are excited by the pulsed laser source and the total X‐ray fluorescence yield (TFY) from the sample is recorded using silicon avalanche photodiode detectors (APDs). The subsequent digitizer card samples the APD signal traces in 0.5 ns steps with 12‐bit resolution. These traces are then processed to deliver an integrated value for each recorded single X‐ray pulse intensity and sorted into bins according to whether the laser excited the sample or not. For each subgroup the recorded single‐shot values are averaged over ~107 pulses to deliver a mean TFY value with its standard error for each data point, e.g. at a given X‐ray probe energy. The sensitivity reaches down to the shot‐noise limit, and signal‐to‐noise ratios approaching 1000 are achievable in only a few seconds collection time per data point. The dynamic range covers 100 photons pulse?1 and is only technically limited by the utilized APD.  相似文献   

6.
A new concept for shortening hard X‐ray pulses emitted from a third‐generation synchrotron source down to few picoseconds is presented. The device, called the PicoSwitch, exploits the dynamics of coherent acoustic phonons in a photo‐excited thin film. A characterization of the structure demonstrates switching times of ≤ 5 ps and a peak reflectivity of ~10?3. The device is tested in a real synchrotron‐based pump–probe experiment and reveals features of coherent phonon propagation in a second thin film sample, thus demonstrating the potential to significantly improve the temporal resolution at existing synchrotron facilities.  相似文献   

7.
The accuracy that can be achieved in single‐pulse pump‐probe Laue experiments is discussed. It is shown that with careful tuning of the experimental conditions a reproducibility of the intensity ratios of equivalent intensities obtained in different measurements of 3–4% can be achieved. The single‐pulse experiments maximize the time resolution that can be achieved and, unlike stroboscopic techniques in which the pump‐probe cycle is rapidly repeated, minimize the temperature increase due to the laser exposure of the sample.  相似文献   

8.
Ultra-fast x-ray-dynamic experimental subsystem is a facility which can provide femtosecond hard x-ray sources using a femtosecond laser interacting with plasmas. By utilizing these ultra-fast x-rays as a probe, combined with a naturally synchronized driver laser as a pump, we can perform dynamic studies on samples with a femtosecond time resolution.This subsystem with a four-dimensional ultra-high spatiotemporal resolution is a powerful tool for studies of the process of photosynthesis, Auger electron effects, lattice vibrations, etc. Compared with conventional x-ray sources based on accelerators, this table-top laser-driven x-ray source has significant advantages in terms of the source size, pulse duration,brightness, flexibility, and economy. It is an effective supplement to the synchrotron light source in the ultrafast detection regime.  相似文献   

9.
A full‐field hard X‐ray imaging beamline (BL‐4) was designed, developed, installed and commissioned recently at the Indus‐2 synchrotron radiation source at RRCAT, Indore, India. The bending‐magnet beamline is operated in monochromatic and white beam mode. A variety of imaging techniques are implemented such as high‐resolution radiography, propagation‐ and analyzer‐based phase contrast imaging, real‐time imaging, absorption and phase contrast tomography etc. First experiments on propagation‐based phase contrast imaging and micro‐tomography are reported.  相似文献   

10.
Angiogenesis, new blood vessels sprouting from pre‐existing vessels, is essential to tumor growth, invasion and metastasis. It can be used as a biomarker for early stage tumor diagnosis and targeted therapy. To visualize angiogenesis many molecular imaging modalities have been used. In this study a novel X‐ray molecular targeting probe using superparamagnetic iron oxide (SPIO) conjugated with arginine–glycine–aspartic acid (SPIO–RGD) has been developed. Based on the extremely high sensitivity to the iron element of synchrotron radiation X‐ray fluorescence and the superior spatial resolution of third‐generation synchrotron radiation, the feasibility of SPIO–RGD as a promising molecular probe for imaging tumor angiogenesis has been demonstrated.  相似文献   

11.
High‐resolution analyser‐based X‐ray imaging computed tomography (HR ABI‐CT) findings on in vitro human breast cancer are compared with histopathology, mammography, computed tomography (CT) and magnetic resonance imaging. The HR ABI‐CT images provided significantly better low‐contrast visibility compared with the standard radiological images. Fine cancer structures indistinguishable and superimposed in mammograms were seen, and could be matched with the histopathological results. The mean glandular dose was less than 1 mGy in mammography and 12–13 mGy in CT and ABI‐CT. The excellent visibility of in vitro breast cancer suggests that HR ABI‐CT may have a valuable role in the future as an adjunct or even alternative to current breast diagnostics, when radiation dose is further decreased, and compact synchrotron radiation sources become available.  相似文献   

12.
The application of a novel fast optical‐imaging camera, TimepixCam, to molecular photoionization experiments using the velocity‐map imaging technique at a free‐electron laser is described. TimepixCam is a 256 × 256 pixel CMOS camera that is able to detect and time‐stamp ion hits with 20 ns timing resolution, thus making it possible to record ion momentum images for all fragment ions simultaneously and avoiding the need to gate the detector on a single fragment. This allows the recording of significantly more data within a given amount of beam time and is particularly useful for pump–probe experiments, where drifts, for example, in the timing and pulse energy of the free‐electron laser, severely limit the comparability of pump–probe scans for different fragments taken consecutively. In principle, this also allows ion–ion covariance or coincidence techniques to be applied to determine angular correlations between fragments.  相似文献   

13.
Elementary scattering processes in solid matter occur on ultrafast timescales and photoelectron spectroscopy in the time domain represents an excellent tool for their analysis. Conventional photoemission accesses binding energies of electronic states and their momentum dispersion. The use of femtosecond laser pulses in pump‐probe experiments allows obtaining direct insights to the energy and momentum dependence of ultrafast dynamics. This article introduces the elementary interaction processes and emphasizes recent work performed in this rapidly developing field. Decay processes in the low excitation limit are addressed, where electrons decay according to their interaction with carriers in equilibrium. Here, hot electron relaxation in epitaxial metallic film is reviewed. In the limit of an intense optical excitation, scattering of the excited electrons among each other establishes a non‐equilibrium state. Results on charge‐density wave materials and the effect of coherent nuclear motion on the electronic structure, which can break low symmetry ground states, are discussed. Figure reprinted with permission from [71].  相似文献   

14.
The optical design of the BOREAS beamline operating at the ALBA synchrotron radiation facility is described. BOREAS is dedicated to resonant X‐ray absorption and scattering experiments using soft X‐rays, in an unusually extended photon energy range from 80 to above 4000 eV, and with full polarization control. Its optical scheme includes a fixed‐included‐angle, variable‐line‐spacing grating monochromator and a pair of refocusing mirrors, equipped with benders, in a Kirkpatrick–Baez arrangement. It is equipped with two end‐stations, one for X‐ray magnetic circular dichroism and the other for resonant magnetic scattering. The commissioning results show that the expected beamline performance is achieved both in terms of energy resolution and of photon flux at the sample position.  相似文献   

15.
A RATIO method for analysis of intensity changes in time‐resolved pump–probe Laue diffraction experiments is described. The method eliminates the need for scaling the data with a wavelength curve representing the spectral distribution of the source and removes the effect of possible anisotropic absorption. It does not require relative scaling of series of frames and removes errors due to all but very short term fluctuations in the synchrotron beam.  相似文献   

16.
The time‐domain nonlinear spectroscopy of a single silver nano‐object is investigated by combining the spatial modulation linear spectroscopy technique with a high‐sensitivity femtosecond pump–probe setup. The investigated single nanoparticle is first optically characterized for size and shape via quantitative measurement of its linear absorption spectrum, and time‐resolved nonlinear pump‐probe measurements are subsequently performed on the same particle. The breathing mode period of a single nanoparticle measured in the time domain is found to be in good agreement with that inferred by the optically deduced particle characteristics, opening the way of full optical investigation of the acoustic response of the characterized single nanoparticles. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
Energy‐domain grazing‐incidence 57Fe‐Mössbauer spectroscopy (E‐GIMS) with synchrotron radiation (SR) has been developed to study surface and interface structures of thin films. Highly brilliant 57Fe‐Mössbauer radiation, filtered from SR by a 57FeBO3 single‐crystal nuclear Bragg monochromator, allows conventional Mössbauer spectroscopy to be performed for dilute 57Fe in a mirror‐like film in any bunch‐mode operation of SR. A theoretical and experimental study of the specular reflections from isotope‐enriched (57Fe: 95%) and natural‐abundance (57Fe: ~2%) iron thin films has been carried out to clarify the basic features of the coherent interference between electronic and nuclear resonant scattering of 57Fe‐Mössbauer radiation in thin films. Moreover, a new surface‐ and interface‐sensitive method has been developed by the combination of SR‐based E‐GIMS and the 57Fe‐probe layer technique, which enables us to probe interfacial complex magnetic structures in thin films with atomic‐scale depth resolution.  相似文献   

18.
结合飞秒激光在研究分子激发态弛豫动力学中的应用,介绍了几种飞秒时间分辨实验中确定泵浦激光脉冲与探测激光脉冲的相关函数和时间零点的方法.对于波长在可见波段的泵浦和探测激光脉冲,我们可以利用非线性光学的技术手段,探测泵浦光与探测光的和频光的强度随二者间的时间延迟的变化来确定相关函数和时间零点;对于波长在紫外甚至更短的波段的泵浦和探测激光脉冲,由于单脉冲能量比较低,目前还很难利用技术手段来测定泵浦激光与探测激光的相关函数及时间零点,可以利用某些原子气体(如Xe)或某些具有短寿命态的分子作平行实验进行间接测量.  相似文献   

19.
Recent research progress using X‐ray cryo‐crystallography with the photon beams from third‐generation synchrotron sources has resulted in recognition that this intense radiation commonly damages protein samples even when they are held at 100 K. Other structural biologists examining thin protein crystals or single particle specimens encounter similar radiation damage problems during electron diffraction and imaging, but have developed some effective countermeasures. The aim of this concise review is to examine whether analogous approaches can be utilized to alleviate the X‐ray radiation damage problem in synchrotron macromolecular crystallography. The critical discussion of this question is preceded by presentation of background material on modern technical procedures with electron beam instruments using 300–400 kV accelerating voltage, low‐dose exposures for data recording, and protection of protein specimens by cryogenic cooling; these practical approaches to dealing with electron radiation damage currently permit best resolution levels of 6 Å (0.6 nm) for single particle specimens, and of 1.9 Å for two‐dimensional membrane protein crystals. Final determination of the potential effectiveness and practical value of using such new or unconventional ideas will necessitate showing, by experimental testing, that these produce significantly improved protection of three‐dimensional protein crystals during synchrotron X‐ray diffraction.  相似文献   

20.
This article reports on studies of the chemical alterations induced by synchrotron radiation at the calcite–ethanol interface, a simple model system for interfaces between minerals and more complex organic molecules containing OH groups. A combination of X‐ray reflectivity and X‐ray photoelectron spectroscopy of natural calcite, cleaved in distilled ethanol to obtain new clean interfaces, indicated that, during a 5 h period, the two top atomic layers of calcite, CaCO3, transform into calcium oxide, CaO, by releasing CO2. Also, the occupation of the first ordered layer of ethanol attached to calcite by hydrogen bonds almost doubles. Comparison between radiated and non‐radiated areas of the same samples demonstrate that these effects are induced only by radiation and not caused by aging. These observations contribute to establishing a time limit for synchrotron experiments involving fluid–mineral interfaces where the polar OH group, as present in ethanol, plays a key role in their molecular structure and bonding. Also, the chemical evolution observed in the interface provides new insight into the behavior of some complex organic molecules involved in biomineralization processes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号