首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
Glass capillaries were leached, dehydrated, persilylated with 1, 3-bis (3-cyanopropyl) tetramethyldisiloxane, and coated with OV-240-OH. After crosslinking and binding the phase to the glass surface the columns showed high separation efficiency, high temperature stability, and inertness comparable to persilylated apolar columns. Column performance is shown to be superior to liquid phase cyanopropyl columns such as SP 2330. The excellent separation capabilities together with the selectivity of the phase makes OV-240-OH coated columns a valuable tool for the determination of toxic isomers in complex mixtures of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The order of elution of individual TCDD isomers was found to be similar to that described for SP 2330 or Silar 10c. The detection of PCDDs and PCDFs in a fly ash extract further illustrates the utility of OV-240-OH coated columns. The high temperature limit of these columns opens the way for the analysis of high boiling compounds such as mixed brominated/chlorinated dibenzo-p-dioxins and dibenzofurans.  相似文献   

2.
Glass capillaries coated with four crosslinked and surface-bonded OH-terminated polysiloxanes [PS 347.5, OV-17-OH, OV-225-OH, and OV-240-OH] were compared with commonly used methyl-terminated SP-2330-coated columns with respect to their selectivity for the separation of 2,3,7,8-chloro-substituted dibenzo-p-dioxins and dibenzofurans. The methyl- and phenyl-substituted phases [PS 347.5 and OV-17-OH] exhibit only moderate isomer selectivity which limits their applicability in this field. The examined 3-cyanopropyl-substituted phases [OV-225-OH, OV-240-OH, and SP-2330] allow complete separation of all 2,3,7,8-chlorosubstituted PCDDs and PCDFs. With SP-2330 longer columns are required (50 m) for baseline separation of critical groups of isomers. OV-225-OH was found to be the most suitable phase as to isomer selectivity. In comparison to SP-2330, the analysis times can be reduced by a factor of two.  相似文献   

3.
A new simplified method was developed for the preparation of immobilized stationary phase fused silica capillary columns coated with OV-1-vinyl, SE-54, and OV-1701-vinyl. This methodology includes the application of the moderately polar stationary phase OV-1701-vinyl as a surface deactivation agent that may also participate in the dicumyl peroxide initiated free radical immobilization process. Practical details of the procedure are presented and applications of the laboratory-produced columns are illustrated with capillary gas chromatographic separations of standard mixtures. Possible contributions of the OV-1701-vinyl deactivation layer to both crosslinking and surface bonding in the immobilization process are discussed.  相似文献   

4.
Borosilicate glass capillaries, silylated and coated with OV-1 or SE-54, were irradiated by a 60Co gamma source. The effect of radiation on chromatographic performance was determined for a series of dosages and was evaluated before and after rinsing with solvent. Results for both regular and thick films were obtained.  相似文献   

5.
This contribution describes GC/MS analysis of natural petroporphyrin extracts containing alkylporphyrins either as vanadyl complexes or as demetalated free bases. The combination of high temperature glass capillary gas chromatography with mass spectrometry allows, for the first time, direct determination of electron impact mass spectra of separated alkylporphyrins, making additional purification and derivatization unnecessary. The separation is carried out on glass capillary columns coated with the high temperature-stable medium polar, OH-terminated, polysiloxane phases PS 086 and OV-225-OH. The paper gives detailed working directions for the preparation of the high temperature GC/MS-interface, and of the high temperature stable OV-225-OH columns (max. working temperature 390°C).  相似文献   

6.
Summary Reproducibility of the Kovats retention indices of alkylbenzenes was studied on conventional “PONA” fused-silica capillary columns coated with crosslinked dimethyl silicone phase, with a film thickness of 0.5 μm. The data were compared with those obtained on conventional OV-101 columns. The tested PONA columns showed reproducible chromatographic properties, capacity ratios and high efficiencies. Having a standard deviation of s=0.03 i.u. of the retention indices on a single column, the column-to-columns differences were found to be up to 0.3 i.u. Higher indices were determined for crosslinked columns, the difference being in most cases about one i.u.  相似文献   

7.
Commercially available OV-17 was partitioned into a low and a higher molecular weight fraction by supercritical fluid extraction with carbon dioxide. This higher molecular weight fraction is more thermally stable than the original OV-17 due to its more viscous and gum-like nature. Based on the growing evidence in the literature that a deactivating agent for fused silica open tubular columns should be compatible with the stationary phase, a precoat of 1,3,5-trimethyl-1,3,5-triphenylcyclotrisiloxane was applied prior to the static coating of high molecular weight OV-17. Fused silica OV-17 columns prepared in this fashion are stable up to 300°C.  相似文献   

8.
The seed oils of three Maytenus species have been examined by high temperature GLC using SOP-50 (methoxy-terminated) and OV-225-OH (OH-terminated) glasscapillary columns. The main compounds (71–76%) could be identified as α-mono-acetotriacylglycerols by a combination of high temperature GLC-MS in negative chemical ionization mode with a CH4/N2O mixture as reactant gas and other spectroscopical methods (infrared, 1H- and 13C-nuclear magnetic resonance spectroscopy). The OV-225-OH phase demonstrated better separation properties that the SOP-50 phase for this substance class and up to eight species of α-monoacetotriacylglycerols could be separated. The content of usual triacyclglycerols was below 1%. The results of the analysis of the individual fatty acids as their methyl esters by GC and GC-MS are also presented.  相似文献   

9.
Summary A correlation between the retention polarity and the Kováts' coefficient has been found for a number of commercial stationary phases used in gas chromatography. The correlation has been used to predict the polarity of a few mixed stationary phase columns prepared as binary mixtures of OV-101 with OV-25, DC-550 or Carbowax 20M, and also mixtures of OV-225 with SP-2340. A linear relationship was found between polarity and mixture composition. The temperature dependence of the Kováts' coefficient was investigated and found to increase linearly with temperature, the rate of increase depending on the polarity of the stationary phase, with greater increases for more polar stationary phases.  相似文献   

10.
Five commercial varieties of uncoated fused silica capillary tubing used in high resolution gas chromatography were subjected to cobalt-60 gamma radiation. The advantages and superior performance of fused silica open tubular columns coated with OV-1 and subsequently immobilized or crosslinked in situ by radiation is reported in a previous paper in this Journal; however, in this investigation a loss in flexibility of irradiated capillaries was also noted. Quantitative measurements on flexibility were performed on specimens of irradiated fused silica capillaries, indicating that changes do indeed occur upon irradiation. Scanning electron micrographs also illustrate slight deterioration of the outer protective polyimide coating. Most surprisingly, it was also established that a variation does exist in the flexibility of the commercially available raw material studied.  相似文献   

11.
Glass capillary columns coated with OV-225 and Silar 10C were used to analyze estrogens (as their trimethylsilyl derivatives) present in pregnant mares' urine. Such columns provide better resolution in a shorter time than the corresponding packed columns, as exemplified by the separation of estrone from equilin.  相似文献   

12.
The C1 -C6 fatty acids present in various types of heterogeneous animal wastes were isolated by steam distillation and determined as benzyl esters by high resolution gas chromatography. Glass capillary columns, deactivated with barium carbonate and coated with UCON HB 5100, allowed the analysis of benzyl formate, acetate, propionate, isobutyrate, butyrate, isovalerate, valerate, and caproate in less than 20 minutes. Recovery tests, performed on more than 50 different samples, indicated a benzylation yield and an overall efficiency higher than 99%, with a standard deviation of 2.6% (C5) to 6.0% (C1). The absolute detection limit ranged from 0.3 picomole (caproic acid) to 1.0 picomole (formic acid).  相似文献   

13.
Summary The possibilities of OV-1701 and RSL-310, two new stationary phases, have been evaluated for capillary gas chromatography in fused silica columns. OV-1701 is a cyanopropylphenyldimethyl polysiloxane of moderate polarity possessing excellent chromatographic characteristics. The phase exhibits high coating and chromatographic efficiencies, high temperature stability and is suitable for cross-linking. RSL-310 is a polar liquid stationary phase yet to be permanently bonded in a capillary column. The selectivity of both phases extends the applicability of fused silica columns.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

14.
Summary The retention and resolution of simple mixture of Al(III), Cr(III), Co(III), and Fe(III) acetylacetonates were investigated on capillary columns coated with methyl and methyl phenyl silicones (OV-1 or OV-17) used as the stationary phase, at different column temperatures and carrier gas flow rates. Successful elution and good resolution were obtained only for the Al(III) and Cr(III) complexes, both under isothermal and programmed-temperature conditions; better resolution was observed on the column coated with OV 17.  相似文献   

15.
Fused silica capillaries deactivated with D4 and coated with OV-1 were subjected to cobalt-60 gamma radiation in order to elucidate the effect of incident radiation on column performance. The chromatographic performance of these open tubular columns in which OV-1 was polymerized in situ was found to be dependent on the dosage of radiation and was evaluated before and after the irradiated columns were rinsed with solvent. Of the radiation dosages employed, 3 MRad produced superior chromatographic performance coupled with very favorable residual surface activity.  相似文献   

16.
Superox系列固定相是性能优良的氢键型固定相,适用地脂肪醇分析,非级性固定相OV-1柱,经减活处理后亦适宜醇类异构体分离,考察了C1-C2异构醇的36个组分在分离效能。OV-1柱和Superox0.6柱上的保留行为,柱效和极限温度,结果表明,两种柱对醇都有很好的分离效能。OV-1柱柱效及柱温极限高,除了戊醇-3和戊醇-2是重叠峰外,其余组分间有一定分离度,其分离顺序基本上是根据组分的沸点,包括  相似文献   

17.
Two published procedures for glass capillary column production are applied to produce capillaries for chromatography of polar natural compounds. Soda lime glass capillaries, after leaching with aqueous HCL, are either treated with colloidal silicic acid or with barium carbonate and coated with either Silar 7CP or SE 52. A test mixture as well as polar carbohydrate and peptide mixtures are chromatographed on the different columns and their chromatographic properties are evaluated. Combined capillary gas chromatography-electron impact and chemical ionization mass spectrometry are used for identification of the peptide sequence.  相似文献   

18.
研究了甲基四氢苯酐、甲基六氢苯酐、萜烯马来酸酐及氢化萜烯马来酸酐等脂族酸酐在HP-1、HP-5、OV-17和FFAP四种不同极性毛细管色谱柱上的色谱性能。分析结果表明,这四种脂环族酸酐均能在OV-17毛细管色谱柱上获得很好的峰形和分离效果。  相似文献   

19.
Electron capture gas chromatography with three chemically bonded fused-silica capillary columns (CB-FSCs), OV-17, OV-1701, and SE-52, was performed to evaluate peak separability of 28 organochlorine insecticides and related compounds. Relative retention times and relative peak heights to aldrin were measured and calculated. OV-17 CB-FSC showed the best separability among the three CB-FSCs employed and was applied to analysis of extracts from several soil samples with minimum clean-up procedure. The chromatograms obtained demonstrated steady baseline tracings free of interference. Residue data from soil samples were also tabulated.  相似文献   

20.
自行研制了Bentone-34/0V-1高效石英毛细管气相色谱柱,并利用该柱分别对二甲苯、二氯苯和二氯甲苯异构体3种体系进行分析。在选用的色谱条件下,难分离物喷对二甲苯和间二甲苯分离度达3;间二氯苯和对二氯苯分离度达137结果表明该柱具有分离效果好,分析速度快的优点。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号