首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A new method based on matrix solid-phase dispersion (MSPD) extraction was studied to determine aflatoxin B1, B2, G1 and G2 from peanuts. Optimization of different parameters, such as type of solid supports for matrix dispersion and elution solvents were carried out. The method used 2 g of peanut sample, 2 g of C18 bonded silica as MSPD sorbent and acetonitrile as eluting solvent. Recoveries of each aflatoxin spiked to peanut samples at 2.5 ng/g (5 ng/g for aflatoxin G2) level were between 78 and 86% with relative standard deviations ranging from 4 to 7%. The limits of quantification ranged from 0.125 to 2.5 ng/g for the four studied aflatoxins using liquid chromatography (LC) with fluorescence detection. In addition, LC coupled to mass spectrometry with an electrospray interface was used for confirmation of aflatoxins present in real samples. Eleven peanut samples from different countries were analyzed by the proposed method and by using an enzyme-linked immunosorbent assay (ELISA). ELISA test is a good screening method for investigation of these mycotoxins in peanut samples.  相似文献   

2.
A reliable ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of aflatoxins B1, B2, G1, G2, M1 and M2 in peanuts and their derivative products was developed. The sample was extracted by 84% of acetonitrile aqueous solution and the extract was purified by a reliable solid phase extraction-based clean-up method. Then, the analytes were separated on Acquity UPLC HSS T3 column (100 mm × 2.1 mm, 1.8 μm particle size), and eluted with a mobile phase consisting of (A) water containing 0.1% formic acid and (B) acetonitrile/methanol (50/50, v/v). The separated compounds were detected with a Waters Micromass Quattro Ultima Pt tandem quadrupole mass spectrometer operating in positive electro-spray ionization using multiple reaction monitoring mode. The established method was extensively validated by determining the linearity (R2 ≥ 0.9990), average recovery (74.7-86.8%) and precision (relative standard deviation ≤ 10.9%). It was shown to be a suitable method for simultaneous determination of the six aflatoxins in peanuts and their derivative products. Finally, a total of 73 samples randomly collected from different areas in Zhejiang province were screened for aflatoxins with the proposed method. The results showed that 31 samples of peanut butter, 14 samples of fresh peanut and 5 samples of musty peanut were contaminated with aflatoxins. Meanwhile, this was the first report on aflatoxins M1 and M2, which were found in unprocessed peanuts and their derivative products.  相似文献   

3.
Rapid determination of aflatoxins in corn and peanuts   总被引:1,自引:0,他引:1  
A rapid and simple method using ultra-high-pressure liquid chromatography with UV detection for the determination of aflatoxins B1, B2, G1 and G2 in corn and peanuts has been developed. In this method, aflatoxins were extracted with a mixture of acetonitrile and water (86:14) and then purified by solid-phase clean-up with a MycoSep#226 AflaZon(+) column. The toxins were determined by UPLC-UV without derivatizing aflatoxins in real samples, which has not been used in other studies. The mean recoveries of aflatoxins from non-infected peanut and corn samples spiked with aflatoxins B1, B2, G1 and G2 at concentrations from 0.22 to 5 microg/kg were between 83.4% and 94.7%. The detection limits (S/N=3) for B1, B2, G1 and G2 were 0.32, 0.19, 0.32 and 0.19 microg/kg, and the corresponding quantification limits (S/N=10) were 1.07, 0.63, 1.07 and 0.63 microg/kg, respectively. We also applied this method on real samples. Among 16 peanut samples, 2 (12.5% incidence) were contaminated with aflatoxin; among 18 corn samples, 4 (22% incidence) were contaminated. The proposed method is rapid, simple and accurate for monitoring aflatoxins in corn and peanuts.  相似文献   

4.
A collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatography (LC) method for the determination of aflatoxin B1 and total aflatoxins at European regulatory limits. The test portion is extracted with methanol-water (8 + 2) for dried figs and paprika, and with methanol-water (8 + 2) plus hexane (or cyclohexane) for peanut butter and pistachios. The sample extract is filtered, diluted with phosphate buffer saline, and applied to an immunoaffinity column. The column is washed with water and the aflatoxins are eluted with methanol. Aflatoxins are quantitated by reversed-phase LC with post-column derivatization (PCD) involving bromination. PCD is achieved with either an electrochemical cell (Kobra cell) and addition of bromide to the mobile phase or pyridinium hydrobromide perbromide. Determination is by fluorescence. Peanut butter, pistachio paste, dried fig paste, and paprika powder samples, both naturally contaminated with aflatoxins and containing added aflatoxins, were sent to 16 collaborators in 16 European countries. Test portions of samples were spiked at levels of 2.4 and 9.6 ng/g for total aflatoxins which included 1.0 and 4.0 ng/g aflatoxin B1, respectively. Recoveries for total aflatoxins ranged from 71 to 92% with corresponding recoveries for aflatoxin B1 of 82 to 109%. Based on results for spiked samples (blind duplicates at 2 levels) as well as naturally contaminated samples (blind duplicates at 4 levels, including blank), the relative standard deviation for repeatability ranged from 4.6 to 23.3% for total aflatoxins and from 3.1 to 20.0% for aflatoxin B1. The relative standard deviation for reproducibility ranged from 14.1 to 34.2% for total aflatoxins, and from 9.1 to 32.2% for aflatoxin B1. The method showed acceptable within-laboratory and between-laboratory precision for all 4 matrixes, as evidenced by HORRAT values <1, at the low levels of determination for both total aflatoxins and aflatoxin B1.  相似文献   

5.
A high performance liquid chromatographic (HPLC) method is described for the determination of the four major aflatoxins, B1, B2, G1 and G2, in peanut products. The aflatoxins are extracted by adapting a procedure developed by Pons (1) at the SRRC, USDA, and quantitated utilizing a new 5 mum reverse-phase column with NaCl/acetontrile/methanol mobile phase (3 + 1 + 1). The 5 mum column achieved baseline resolution of each of the four aflatoxins. Retention times and peak heights were reproducible. The procedure was successfully applied to several types of peanut products and was applicable to both roasted and unroasted peanuts, which is a decided advantage over the current CB and BF extraction methods. Additionally, it can be used for sweetened peanut matrixes with no interferences in the chromatography. The total time required for sample preparation and aflatoxin determination is less than 1.5 hours.  相似文献   

6.
The application of dispersive liquid-liquid microextraction (DLLME) technique for the rapid analysis of aflatoxins B(1), B(2), G(1) and G(2) in maize, rice and wheat products has been evaluated. After extraction of aflatoxins from cereal matrices with a mixture of methanol/water 8:2 (v/v), the analytes were rapidly transferred from the extract to another small volume of organic solvent, chloroform, by DLLME. Aflatoxins were determined using high performance liquid chromatography with florescence detection and photochemical post-column derivatization. Parameters affecting both extraction and DLLME procedures, such as extraction solvent, type and volume of DLLME extractant, volume of water and salt effect, were systematically investigated and optimized to achieve the best extraction efficiency. Under the optimal experimental conditions, the whole analytical method provides enrichment factors around 2.5 times and detection limits (0.01-0.17 μg kg(-1)) below the maximum levels imposed by current regulation for aflatoxins in cereals and cereal products intended for direct human consumption. Recoveries (67-92%) and repeatability (RSD<10, n=3), tested in three different cereal matrices, meet the performance criteria required by EC Regulation No. 401/2006 for the determination of the levels of mycotoxins in foodstuffs. The proposed method was successfully applied to the analysis of retail cereal products with quantitative results comparable to the immunoaffinity chromatography (IAC). The main advantages of developed method are the simplicity of operation, the rapidity to achieve a very high sample throughput and low cost.  相似文献   

7.
建立了免疫亲和柱净化-柱后电化学衍生-高效液相色谱结合荧光光度法检测花生酱中4种黄曲霉毒素(B1、B2、G1和G2)的方法。样品经过体积分数为60%的甲醇提取,通过免疫亲和柱净化后,以KobraCell装置柱后衍生,高效液相色谱法分离定量。黄曲霉毒素B1、B2、G1和G2能达到完全的基线分离,检测限分别为0.5、0.15、0.5和0.15μg/kg,线性相关系数0.999,回收率可达74.2%~96.5%,相对标准偏差低于11%。该方法能够满足花生酱中黄曲霉毒素检测的需要。  相似文献   

8.
Tuomi T  Johnsson T  Hintikka EL  Reijula K 《The Analyst》2001,126(9):1545-1550
A method is described for the simultaneous determination of common aflatoxins (G1, G2, B1, B2) and their precursor sterigmatocystin, and also citrinine and ochratoxin A. The method was applied to a building material matrix artificially contaminated with mycotoxin-producing fungi. The method includes extraction, sample pre-treatment and reversed-phase HPLC separation with tandem mass spectrometric identification and quantification using electrospray ionisation on a quadrupole ion trap mass analyser (ESI-MS-MS). Aqueous methanol was used in the initial extraction and solvent partitioning and solid phase extraction in the purification of samples. The HPLC separation was run on-line with the ESI-MS-MS detection. The limit of quantification of the procedure was 200 ng for all compounds. Recoveries of the sample pre-treatment varied from 28 to 99%. The average compound- and concentration-dependent accuracy and precision (RSD) were 21 and 113%, respectively. The method includes small sample volumes (approximately 1 g in 20 ml) and few, non-labour intensive, sample treatment steps. It should allow for a high throughput of samples with good prospects of automation.  相似文献   

9.
The stability of aflatoxins B1, B2, G1, and G2 was studied in solutions containing different concentrations of water, acetonitrile, and/or methanol, and in autosampler vials treated with nitric acid or silanized. When stored at room temperature (20 degrees C) for 24 h, aflatoxins G1 and G2 were stable only in solutions containing 100% organic solvent, whereas aflatoxins B1 and B2 were stable in solutions of methanol-water and acetonitrile-water at greater than 60 and 40% organic content, respectively. At 5 degrees C, aflatoxins G1 and G2 showed a significant decrease in concentration only when kept in less than 20% aqueous organic solvent. Significant loss of aflatoxins was realized in standard, commercially available amber type I borosilicate autosampler vials, but chemical etching of the vials with nitric acid or with silanization prevented aflatoxin degradation. These results indicate that aflatoxins are unstable in aqueous solutions and that this instability can be counteracted by the presence of at least 20% organic solvent and keeping the solutions at 5 degrees C or by the use of treated vials.  相似文献   

10.
Han S  Liu Y  Lu M  Li J  Wang J 《色谱》2011,29(7):613-617
利用免疫亲和萃取结合超高效液相色谱-串联四极杆质谱技术(UHPLC-ESI/QqQ-MS/MS)建立了中成药及中药材中5种黄曲霉毒素(B1、B2、G1、G2和M1)的提取、分离、确证与定量方法。样品经80%(体积分数)的甲醇水溶液提取和免疫亲和固相萃取后,采用UHPLC-ESI/QqQ-MS/MS的多反应监测模式实现分离、鉴定和外标法定量。5种目标毒素标准溶液的检出限(LOD)为0.05~0.3 μg/L。在0.5~100 μg/L的基质添加浓度范围内具有良好的线性关系(r2>0.99);以甘草为例,当添加水平为1.0 μg/kg和5.0 μg/kg时,得到62.3%~82.4%的回收率(相对标准偏差(RSD)<10%, n=6)。该方法灵敏度高、选择性和重复性好、回收率较高、检测速度快,适用于中成药及中药材等复杂基体中多种黄曲霉毒素的快速分析与筛查。  相似文献   

11.
A one-dimensional TLC method to determine aflatoxins (B1, B2, G1, G2) in various food matrices was elaborated which abstains fully on the use of chlorinated solvents. It implements an immunoaffinity clean-up step after extraction with methanol. The aflatoxins were quantified by densitometry. The method has shown to be rapid and efficient. In-house performance characteristics were established. The limit of quantification was found to be significantly lower than current regulatory limits for aflatoxin control outside and within the European Community. The obtained recovery and precision data gave a strong indication, that the method is likely to give satisfactory performance if tested in a future collaborative trial.  相似文献   

12.
The simultaneous analysis of aflatoxins B1, G1, B2, G2 and ochratoxin A in beer was carried out by ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS). Mycotoxins were extracted, purified and concentrated from the beer sample in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric sorbent. Optimization of different parameters, such as type of SPE sorbent, type and amount of wash solvent and pH of the sample, was carried out. The mobile phase consisted of a gradient of methanol + water (0.1% HCOOH) and a reversed-phase C18 column was used for the separation. The mass spectrometer used an electrospray ionization source operated in the positive mode to detect aflatoxins and in the negative mode to detect ochratoxin. UPLC/MS/MS is a rapid and sensitive technique that allows the separation of the five toxins in only 3.2 min. The limit of detection is 1 pg.  相似文献   

13.
液相色谱-串联质谱法测定动物肝脏中黄曲霉毒素   总被引:2,自引:0,他引:2  
建立了动物肝脏中黄曲霉毒素G2、G1、B2、B1的高效液相色谱-串联质谱检测方法。样品经体积比为84∶16的乙腈-水溶液提取,离心后通过真菌毒素多功能净化柱,净化液氮气吹干,用流动相定容,采用C18柱分离,10mmol/L的甲酸铵溶液和甲醇作为流动相,以50∶50比例等度洗脱,在多重反应监测(MRM)正离子模式下进行分析。各组分在9min内完全分离,方法线性关系良好,黄曲霉毒素G2、G1、B2、B1的检出限分别为0.030、0.026、0.016、0.027μg/kg,三个加标水平下平均回收率在81%~98%之间,相对标准偏差小于2%。该方法简便快速,准确可靠,可用于动物肝脏中黄曲霉毒素的测定。  相似文献   

14.
液相色谱-三重串联四极杆质谱测定粮油中的黄曲霉毒素   总被引:5,自引:0,他引:5  
Wang X  Li P  Yang Y  Zhang W  Zhang Q  Fan S  Yu L  Wang L  Chen X  Li Y  Jiang J 《色谱》2011,29(6):517-522
建立了超声提取-液相色谱-电喷雾三重串联四极杆质谱测定玉米、大米、大豆等粮油固体样品中黄曲霉毒素B1、B2、G1和G2(AFB1、AFB2、AFG1和AFG2)的方法。分析前对样品进行超声提取,优化得到最佳超声提取条件: 溶剂为甲醇-水(含40 g/L NaCl) (80:20, v/v)溶液、料液比为1:3(g:mL)、温度为50 ℃、时间为3 min。然后对提取的样品进行免疫亲和特异性净化。最后与液相色谱-电喷雾三重串联四极杆质谱联用,使用C18反相色谱柱,流动相为甲醇-10 mmol/L乙酸铵水溶液梯度洗脱,以黄曲霉毒素M1(AFM1)作为内标进行定量测定。结果表明,AFB1、AFB2、AFG1和AFG2的检出限分别为0.002、0.004、0.004和0.012 μg/kg。方法的加标回收率为87%~111%,日内相对标准偏差(RSD)和日间RSD分别不大于6.7%和5.6%。实验结果表明该方法可以有效地降低基质效应的影响,相比于外标法能极大地提高方法的准确度。  相似文献   

15.
A novel approach for assembling homogeneous hyperbranched polymers based on non-covalent interactions with aflatoxins was developed; the polymers were used to evaluate the extraction of aflatoxins B1, B2, G1 and G2 (AFB1, AFB2, AFG1 and AFG2) in simulant solutions. The results showed that the extraction efficiencies of three kinds of synthesized polymers for the investigated analytes were not statistically different; as a consequence, one of the representative polymers (polymer I) was used as the solid-phase extraction (SPE) sorbent to evaluate the influences of various parameters, such as desorption conditions, pH, ionic strength, concentration of methanol in sample solutions, and the mass of the sorbent on the extraction efficiency. In addition, the extraction efficiencies for these aflatoxins were compared between the investigated polymer and the traditional sorbent C18. The results showed that the investigated polymer had superior extraction efficiencies. Subsequently, the proposed polymer for the SPE packing material was employed to enrich and analyze four aflatoxins in the cereal powder samples. The limits of detection (LODs) at a signal-to-noise (S/N) ratio of 3 were in the range of 0.012–0.120 ng g−1 for four aflatoxins, and the limits of quantification (LOQs) calculated at S/N = 10 were from 0.04 to 0.40 ng g−1 for four aflatoxins. The recoveries of four aflatoxins from cereal powder samples were in the range of 82.7–103% with relative standard deviations (RSDs) lower than 10%. The results demonstrate the suitability of the SPE approach for the analysis of trace aflatoxins in cereal powder samples.  相似文献   

16.
A rapid and simple quantitative method for the simultaneous determination of the four aflatoxins (AFs) B1, B2, G1 and G2 was developed using reverse homogeneous liquid–liquid extraction (RHLEE) and HPLC post-column derivatization-fluorescence (HPLC-FL) detection. The method based on the rapid extraction of AFs from a methanolic sample into chloroform after addition of water containing KBr, with a method we called reverse homogeneous liquid–liquid extraction. Recoveries were in the range of 88–125% and the limits of detection were between 0.001–0.042 ng g?1 for different AFs. Wheat and pistachio were chosen for the analysis of real samples and the method was also successfully applied to a FAPAS® TEST MATERIAL (T04151).  相似文献   

17.
An HPLC analytical method combining methanol-deionised water (80:20, v/v) extraction, methanol-acetonitrile (50:50, v/v) extraction and fluorescence detection was implanted to analyse ochratoxin A and aflatoxins B1, B2, G1 and G2 of air samples collected during the usual production process in a number of workplaces of a coffee factory to assess the occupational exposure of the engaged workers. The average levels of airborne ochratoxin A and aflatoxins were less than 1.2 and 0.4 ng/m3, respectively, using 50 L air samples. When 150 L air samples were used, levels lower than 0.04 ng/m3 ochratoxin A and 0.013 ng/m3 for aflatoxins B1, B2, G1 and G2, could be detected.  相似文献   

18.
A reliable and rapid method has been developed for the determination of 10 mycotoxins (beauvericin, enniatin A, A1, B1, citrinin, aflatoxin B1, B2, G1, G2 and ochratoxin A) in eggs at trace levels. Ultra-high-pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) has been used for the analysis of these compounds in less than 7 min. Mycotoxins have been extracted from egg samples using a QuEChERS-based extraction procedure (Quick, Easy, Cheap, Effective, Rugged and Safe) without applying any further clean-up step. Extraction, chromatographic and detection conditions were optimised in order to increase sample throughput and sensitivity. Matrix-matched calibration was used for quantification. Blank samples were fortified at 10, 25, 50 and 100 μg kg(-1), and recoveries ranged from 70% to 110%, except for ochratoxin A and aflatoxin G1 at 10 μg kg(-1), and aflatoxin G2 at 50 μg kg(-1). Relative standard deviations were lower than 25% in all the cases. Limits of detection ranged from 0.5 μg kg(-1) (for aflatoxins B1, B2 and G1) to 5 μg kg(-1) (for enniatin A, citrinin and ochratoxin A) and limits of quantification ranged from 1 μg kg(-1) (for aflatoxins B1, B2 and G1) to 10 μg kg(-1) (for enniatin A, citrinin and ochratoxin A). Seven samples were analyzed and aflatoxins B1, B2, G1, G2, and beauvericin were detected at trace levels.  相似文献   

19.
A method was developed for the extraction and determination of unconjugated aflatoxins in human urine by high-performance liquid chromatography. The analysis is based on the elimination of lipid-soluble constituents other than unconjugated aflatoxins in urine by light petroleum extraction. The unconjugated aflatoxins were subsequently extracted from the aqueous phase with chloroform-acetone. Chromatography was performed isocratically with a silica column at 40 degrees C. The resolved aflatoxins were detected and identified by ultraviolet and fluorometric detectors. The recoveries of aflatoxins B1 and G1 added prior to the extraction were 72% and 83%, respectively. This procedure is simple, sensitive and practically useful for epidemiological survey of unconjugated aflatoxins in human urine from areas with a high risk of aflatoxin consumption.  相似文献   

20.
A commercially available system is described for the fully automated clean-up and high-performance liquid chromatographic (HPLC) analysis of aflatoxins in foods and animal feeds. The system marketed primarily for handling solid-phase extraction columns has modified software to facilitate use with immunoaffinity columns. Sample extract clean-up followed by injection onto an HPLC column with post-column iodination and fluorescence detection is carried out completely unattended. A coefficient of variation of 5.1% for aflatoxin B1 analysis was obtained, and the accuracy of the system was demonstrated by the analysis of peanut butter certified reference material.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏