首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel method of online microcolumn separation and preconcentration coupled to inductively coupled plasma atomic emission spectrometry (ICP-AES) with the use of acetylacetone-modified silica gel as packing material was developed for the determination of trace rare earth elements (REEs) in environmental and food samples. The main parameters affecting online separation/preconcentration, including pH, sample flow rate, sample volume, elution and interfering ions, have been investigated in detail. Under the optimized operating conditions, the adsorption capacity values for Sc, Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu were 25.65, 23.23, 24.01, 19.40, 22.89, 23.77, 24.40, 23.96, 25.58, 25.15, 24.86, 22.75, 16.05, 24.13, 26.51 and 27.93 mg g(-1), respectively. Detection limits (3sigma) based on three times standard deviations of the blanks by 8 replicates were in the range from 48 pg mL(-1) for Lu to 1003 pg mL(-1) for Sm. With 90 s preconcentration time and 10 s elution time, the enrichment factor was 10 and the sample frequency was 28 h(-1). The precisions (RSDs) obtained by determination of a 250 ng mL(-1) (n = 8) REEs standard solution were in the range from 1.7% for Y to 4.4% for Sm. The proposed method was successfully applied to the determination of trace REEs in pig liver, agaric and mushroom. To validate the proposed method, we analyzed three certified reference materials (GBW07401 soil, GBW07301a sediment, and GBW07605 tea leaves). The determined values were in a good agreement with the certified values. The method is rapid, selective, sensitive and applicable to the determination of trace REEs in biological and environmental samples with complicated matrix effects.  相似文献   

2.
Hirata S  Kajiya T  Aihara M  Honda K  Shikino O 《Talanta》2002,58(6):1185-1194
A home made column of commercially available iminodiacetate resin, Muromac A-1 (50–100 mesh) was used to concentrate rare earth elements (REEs) (15 elements: Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) in seawater. An automated low pressure flow analysis method with on-line column preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) is described for the determination of REEs in seawater. Sample solutions (adjusted to pH of 3.0) passed through the column. After washing the column with water, the adsorbed elements were subsequently eluted into the plasma with 0.7 M nitric acid. Calibration curves were accomplished by means of purified artificial seawater with a sample loading time of 120 s. Detection limits (DLs) of the on-line column preconcentration/ICP-MS by eight replicate operations were between 0.040 and 0.251 pg ml−1 for REEs in the artificial seawater. The precision was less than 8.9% for REEs and one sample can be processed in 7 min using a 7 ml of sample. The proposed method was applied to determine REEs in coastal seawater of Hiroshima Bay, Japan.  相似文献   

3.
Based on carbon nanofibers (CNFs) as a solid phase extraction adsorbent, a microcolumn preconcentration method coupled to inductively coupled plasma mass spectrometry (ICP–MS) was developed for the determination of trace elements (Mn, Co and Ni). The effect of various experimental parameters such as pH, sample flow rate and volume, elution solution and interfering ions on the retention of the studied ions have been investigated systematically. During all the steps of the experimental process, Mn, Co and Ni could be quantitatively sorbed on the microcolumn containing CNFs in the range of pH 6.0–9.0, and then eluted completely with 0.5 mol ml− 1 HNO3. A preconcentration factor of 150-fold was obtained. The detection limits for Mn, Co and Ni were 40, 0.4 and 8.0 pg ml− 1, respectively, with relative standard deviations less than 6.0%. In order to validate the proposed method, two certified reference materials of human hair (GBW 07601) and mussel (GBW 08571), and water sample were analyzed with satisfactory results. The recoveries were between 95.0 and 114%.  相似文献   

4.
Qiang Fu  Qiuquan Wang 《Talanta》2007,72(4):1248-1254
A newly synthesized alkyl phosphinic acid resin (APAR) was used for on-line preconcentration of trace rare earth elements (REES, lanthanides including yttrium) and then determined by inductively coupled plasma mass spectrometry. REEs in seawater could be on-line concentrated on the APAR packed column (4.6 mm i.d. × 50 mm in length), and eluted from the column with 0.5 mL 0.1 mol L−1 nitric acid within 30 s. An enrichment factor of nearly 400 was achieved for all REEs when the seawater sample volume was 200 mL, while the matrix and coexisting spectrally interfering ions such as barium, tin and antimony could be simultaneously separated. The detection limits of this proposed method for REEs were in the range from 1.43 pg L−1 of holmium to 12.7 pg L−1 of lanthanum. The recoveries of REEs were higher than 97.9%, and the precision of the relative standard deviation (R.S.D., n = 6) was less than 5%. The method has been applied to the determination of soluble REEs in seawater.  相似文献   

5.
A simple and sensitive method for the determination of isophorone in food samples was developed by headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS). Isophorone was separated within 10 min by GC-MS using a DB-1 capillary column and detected with selective ion monitoring mode. The HS-SPME using a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber provided effective sample enrichment, and was carried out by fiber exposition at 60 degrees C for 45 min. The extracted isophorone was easily desorbed by fiber exposition in the injection port of a capillary GC-MS system, and carryover was not observed. Using this method, the calibration curve of isophorone was linear in the range 20-1000 pg/mL, with a correlation coefficient 0.9996 (n = 18), and the detection limit (S/N = 3) was 0.5 pg/mL. The HS-SPME/GC-MS method showed 25,000-fold higher sensitivity than the direct injection method (1 microL injection). The within-day and between-day precisions (relative standard deviations) at the concentration of 1 ng/mL isophorone were 3.9% and 6.1% (n=5), respectively. This method was successfully applied to the analysis of food samples without interference peaks. The recoveries of isophorone spiked into food sample were above 84% for a 50 or 500 pg/mL spiking concentration. The analytical results of the contents of isophorone in various food samples were presented.  相似文献   

6.
An analytical method has been developed for the preconcentration of rare earth elements (REEs) in seawater for their determination by inductively coupled plasma optical emission spectrometry (ICP‐OES). An indigenously synthesized chelating resin was used for the preconcentration of (REEs) which was based on immobilization of fluorinated β‐diketone group on solid support styrene divinyl benzene. Sample solutions (adjusted to optimized pH) were passed through a polyethylene column packed with 250 mg of the resin. Experimental conditions consisting of pH, sample flow rate, sample volume and eluent concentration were optimized. The established method has been applied for the preconcentration of light, medium and heavy REEs in coastal sea water samples for their subsequent determination by (ICP‐OES). Percentage recoveries of La, Ce, Nd, Sm, Eu, Gd, Dy, Er, Yb and Lu were ≥ 95%, a preconcentration factor of 200 times, and relative standard deviations < 5% were achieved.  相似文献   

7.
A sol-gel zirconia coating was developed for the preconcentration/separation of trace Cr, Cu, Cd and Pb by capillary microextraction, and the adsorbed analytes were on-line eluted for detection using inductively coupled plasma mass spectrometry (ICP-MS). By immobilizing sol-gel zirconia on the inner surface of a fused-silica capillary, the sol-gel zirconia coating was simply prepared. Its adsorption properties, stability and the factors affecting the adsorption behaviors of Cr, Cu, Cd and Pb were investigated in detail. In the pH range from 7.8 to 10, the zirconia-coated capillary (35 cm x 0.15 mm) is selective towards Cr, Cu, Cd and Pb, and the analyzed ions could be desorbed quantitatively with 0.2 mL of 0.5 mol/L HNO(3) at a rate of 0.2 mL/min. With a consumption of 1.25 mL sample solution, an enrichment factor of 6.25, and detection limits (3sigma) of 9.9 pg/mL Cr, 17.9 pg/mL Cu, 4.5 pg/mL Cd and 3.7 pg/mL Pb were obtained. The precisions for nine replicate measurements of 1 ng/mL Cr, Cu, Cd and Pb were 4.9% Cr, 2.2% Cu, 2.0% Cd and 3.2% Pb (RSD), respectively. The proposed procedure has been applied to the determination of Cr, Cu, Cd and Pb in human urine, which was subjected to microwave-assisted digestion prior to analysis, and the recoveries for these elements were 89.2-101.8%. In order to validate the developed procedure, a NIES No.10-a Rice Flour-Unpolished certified reference material and a BCR No. 184 Bovine Muscle certified reference material were analyzed, and the results are in good agreement with the certified values.  相似文献   

8.
A new method has been developed for the determination of trace rare earth elements (REEs) in water samples based on preconcentration with a microcolumn packed with multiwalled carbon nanotubes (MWNTs) prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimum experimental parameters for preconcentration of REEs, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. The studied REEs ions can be quantitatively retained by MWNTs when the pH exceed 3.0, and then eluted completely with 1.0 mol L−1 HNO3. The detection limits of this method for REEs was between 3 and 57 ng L−1, and the relative standard deviations (RSDs) for the determination of REEs at 10 ng mL−1 level were found to be less than 6% when processing 100 mL sample solution. The method was validated using a certified reference material, and has been successfully applied for the determination of trace rare earth elements in lake water and synthetic seawater with satisfactory results.  相似文献   

9.
The rare earth elements (REEs) play very important roles in industrial manufacturing, technology development and biological processes. Due to their complex emission spectra, trace levels of REEs are difficult to analyze by conventional ICP-AES techniques. The present study investigates possible spectral interferences of matrices (rare earth oxides of Ce, Pr, Nd, Sm and Dy) on the analytical lines (± 0.1 nm) of a target REE. Detailed and well-resolved spectra for selected REEs are presented, and procedures used to rectify the problem of spectral interferences caused by REE matrices are discussed. A computer-assisted system (CAS) for spectral recognition has been developed and used to assist in the study of matrix interference. To determine directly trace rare earth elements in REE matrices without sample pre-separation, the application potential is demonstrated with a one meter sequential instrument retrofitted with a 3600 grooves/mm grating.  相似文献   

10.
A separation and preconcentration method based on solid-phase extraction using sulfoxide adsorbent was developed for the determination of Hg(II) in natural water samples by inductively coupled plasma mass spectrometry (ICP-MS). The sulfoxide adsorbent was packed into a commercially available syringe-driven column (with a bed volume of 1.0 mL), which permitted off-line sample loading and on-line elution/measurement. The optimized operating conditions were as follows: sample condition for Hg(II) adsorption, 0.5% HCl; sample-loading flow rate, 10 mL min(-1); eluent for recovering Hg(II), 1% cysteine water solution. A test using multi-element mixed solution showed that most trace elements in natural water, except for Bi, could be completely separated from Hg(II). The recoveries of Hg(II) were 99.0 ± 3.2 and 100.7 ± 4.3%, respectively, when 0.64 and 0.16 ng mL(-1) of Hg(II) were added into the test sample. The detection limit of Hg(II) using a quadrupole ICP-MS after 10-fold preconcentration was 1.5 pg mL(-1). The blank value was 2.8 ± 0.5 pg mL(-1).  相似文献   

11.
Zhuomin Zhang  Xi Chen 《Talanta》2009,78(3):1083-1240
A new solid phase microextraction (SPME) method coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid determination of four anabolic steroids such as 3α-hydroxy-5α-androstane-17-one (HA), dihydrotestosterone (DHT), androstenedione (AD) and methyltestosterone (MT) in pig urine. SPME was used to extract the four anabolic compounds directly without derivatization. The optimum SPME sampling conditions were based on the home-made carbowax-divinylbenzene (CW-DVB) fiber coating during extraction at 40 °C for 50 min with 0.18 g/mL NaCl solution and 750 rpm stirring speed. The linear ranges of the proposed method were in the range of 8-640 pg/mL for HA and DHT and 16-510 pg/mL for AD and MT, respectively. The detection limits (S/N = 3) were from 2 to 8 pg/mL for the four anabolic steroids. This SPME method provided very high enrichment factors for the four anabolic steroids, which were 1063-fold and 965-fold for HA and DHT at the concentration of 8 pg/mL and 207-fold and 451-fold for AD and MT at the concentration of 16 pg/mL, respectively. The recoveries ranged from 71.3 to 121%, and the RSDs were lower than 12.9%. The method was sensitive and reliable for determination of trace anabolic steroids in biological samples.  相似文献   

12.
本文报道以DCS-偶氮胂固定于活性炭上作为固定相,用于流动注射微柱预富集体系和等离子体原子发射光谱测定痕量稀土元素.测定了吸附材料对稀土元素的静态和动态吸附容量,分别达几十和几个mg/g吸附材料;对影响柱预富集的PH、上柱速度、洗脱酸度、柱尺寸等因素进行了详细考察;在优化条件下,富集倍数为10倍左右.对La、Nd、Eu、Gd、Tb、Dy、Ho和 Lu等元素的检出限为 μg/L级,RSD在 1.5%~3.9%之间(n=6,单一稀土浓度0.085 mg/L).该法应用于高纯锌中痕量稀土元素的测定,试样加入回收率在 84.5%~97.6%之间,分析结果满意.  相似文献   

13.
A new sorbent, maleic acid grafted polytetrafluoroethylene fiber (MA-PTFE), was prepared and evaluated for on-line solid-phase extraction coupled with inductively coupled plasma mass spectrometry (ICP-MS) for fast, selective, and sensitive determination of (ultra)trace rare earth elements (REEs) in environmental samples. The REEs in aqueous samples at pH = 3.0 were selectively extracted onto a microcolumn packed with the MA-PTFE fiber, and the adsorbed REEs were subsequently eluted on-line with 0.9 mol l(-1) HNO3 for ICP-MS determination. The new sorbent extraction system allows effective preconcentration and separation of the REEs from the major matrix constituents of alkali and alkali earth elements, particularly their separation from barium that produces considerable isobaric interferences of 134Ba16O1H+, 135Ba16O+, 136Ba16O1H+, and 137Ba16O+ on 151Eu+ and 153Eu+. With the use of a sample loading flow rate of 7.4 ml min(-1) for 120 s preconcentration, enhancement factors of 69-97 and detection limits (3s) of 1-20 pg l(-1) were achieved at a sample throughput of 22 samples h(-1). The precision (RSD) for 16 replicate determinations of 50 ng l(-1) of REEs was 0.5-1.1%. The developed method was successfully applied to the determination of (ultra)trace REEs in sediment, soil, and seawater samples.  相似文献   

14.
For some saline environments (e.g. deeply percolating groundwater, interstitial water in marine sediments, water sample collected after several steps of fractionation) the volume of water sample available is limited. A technique is presented which enables simultaneous determination of major and trace elements after preconcentration of only 60 mL sample on chelating resins. Chelex-100 and Chelamine were used for the preconcentration of trace elements (Cd, Cu, Pb, Zn, Sc) and rare earth elements (La, Ce, Nd, Yb) from saline water before their measurement by inductively coupled plasma mass spectrometry. Retention of the major elements (Na, Ca, Mg) by the Chelamine resin was lower than by Chelex; this enabled their direct measurement in the solution after passage through the resin column. For trace metal recoveries both resins yield the same mass balance. Only Chelex resin enabled the quantitative recovery of rare earth elements. The major elements, trace metals and rare earth elements cannot be measured after passage through one resin only. The protocol proposes the initial use of Chelamine for measurement of trace and major elements and then passage the same sample through the Chelex resin for determination of the rare earth elements. The detection limit ranged from 1 to 12 pg mL(-1). At concentrations of 1 ng mL(-1) of trace metals and REE spiked in coastal water the precision for 10 replicates was in the range of 0.3-3.4% (RSD). The accuracy of the method was demonstrated by analyzing two standard reference waters, SLRS-3 and CASS-3.  相似文献   

15.
Dwinna Rahmi 《Talanta》2007,72(2):600-606
The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200-400 mesh), with which trace metals in 50 mL of original seawater sample were concentrated into 0.50 mL of 2 M nitric acid, and then 100-fold preconcentration of trace metals was achieved. Then, 0.50 mL analysis solution was subjected to the multielement determination by ICP-MS equipped with a MicroMist nebulizer for micro-sampling introduction. The preconcentration and elution parameters such as the sample-loading flow rate, the amount of 1 M ammonium acetate for elimination of matrix elements, and the amount of 2 M nitric acid for eluting trace metals were optimized to obtain good recoveries and analytical detection limits for trace metals. The analytical results for V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U in three kinds of seawater certified reference materials (CRMs; CASS-3, NASS-4, and NASS-5) agreed well with their certified values. The observed values of rare earth elements (REEs) in the above seawater CRMs were also consistent with the reference values. Therefore, the compiled reference values for the concentrations of REEs in CASS-3, NASS-4, and NASS-5 were proposed based on the observed values and reference data for REEs in these CRMs.  相似文献   

16.
刘晶  何青青  杨丽莉  胡恩宇  王美飞 《色谱》2015,33(10):1110-1114
建立了一种测定水中痕量及超痕量溴酸盐的在线富集大体积进样离子色谱法。采用实验室常备的柱容量较高的Dionex IonPac AG23保护柱作为浓缩柱,连接在定量环处富集溴酸盐。淋洗液自动发生装置在线生成高纯度氢氧化钾淋洗液进行梯度洗脱,抑制电导检测。实验结果表明:溴酸盐质量浓度范围在0.05~51.2 μg/L之间时线性关系良好,相关系数r≥0.9995,方法检出限为0.01 μg/L。与常规进样相比,进样量可高达5 mL,浓缩因子约为240倍。本方法成功应用于市售纯净水中溴酸盐的测定,2个加标水平的回收率在90%~100%之间,RSD(n=6)为2.1%~6.4%。该方法无需前处理,操作简单,准确度和精密度良好。通过大体积进样实现高倍富集,适用于痕量及超痕量溴酸盐的分析。  相似文献   

17.
A new method of ionic liquids based cycle flow single drop microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) was proposed for the determination of trace Co, Hg and Pb with 1-(2-pyridylazo)-2-naphthol (PAN) as both extractant and chemical modifier and 1-butyl-3-methylimidazolium hexafluorophosphate as the extraction solvent. Several factors that influence the microextraction efficiency, such as sample pH, sample flow rate, microdrop volume and extraction time, were investigated and the optimized microextraction conditions were established. Co, Hg and Pb in the post-extraction ionic liquids phase were directly determined by ETV-ICP-MS with the use of PAN as chemical modifier. The chemical modification of PAN in ETV-ICP-MS was studied and the factors affecting the vaporization behaviors of target analytes were investigated. Under the optimized conditions, the detection limits of the method were 1.5, 9.8 and 6.7 pg/mL for Co, Hg and Pb, with the relative standard deviations for 0.5 ng/mL (n = 7) of Co, Hg and Pb were 7.7%, 5.2% and 12.0%, respectively. After 10 min of extraction, the enrichment factors were 350 (Co), 50 (Hg) and 60 (Pb). The proposed method was successfully applied to the determination of trace Co, Hg and Pb in human serum and environmental water samples. In order to validate the developed method, a certified reference material of human hair (GBW07601) was analyzed and the determined values were in good agreement with the certified values.  相似文献   

18.
《Analytical letters》2012,45(11):2105-2115
Abstract

Systematic investigations were carried out into the sorption of rare earth elements (REEs) on carbon nonofibers (CNFs) by inductively coupled plasma mass spectrometry (ICP‐MS). The experimental parameters for preconcentration of REEs, such as pH, sample flow rate and volume, eluent concentration, and interfering ions on preconcentration of REEs have been examined in detail. The studied metal ions can be adsorbed quantitatively on CNFs in a pH range from 2.0 to 5.0, and then eluted completely with 0.5 mol l?1 HNO3. Based on the above facts, a novel method using a microcolumn packed with carbon nanofibers as an adsorption material was developed for the separation and preconcentration of REEs prior to their determination by ICP‐MS. The proposed method has been successfully applied to the determination of light (La), medium (Eu and Gd) and heavy (Yb) rare earth elements in real sample with the recovery more than 90%. In order to validate this method, two certified reference materials of tea leaves (GBW 07605) and mussel (GBW 08571) were analyzed, and the determined values are in good agreement with the certified values.  相似文献   

19.
采用王水溶样,活性炭动态吸附富集,电感耦合等离子体质谱法测定化探样品中痕量金,优化了样品分解、吸附条件、干扰消除等条件。结果表明,检出限0.13ng/mL,RSD〈4.7%,回收率97.63%~103.35%。该法准确可靠、简便快速,能满足化探样品检测要求。  相似文献   

20.
A simple, effective and low cost solid phase extraction procedure was standardized for the trace and ultra-trace level determination of rare earth impurities, such as, Ce, Dy, Sm, Gd, Eu, Er etc. which act as neutron poisons, in nuclear grade uranium oxide (U3O8?>?99.9% by weight). The method involves selective separation of these elements as their fluorides with the help of activated charcoal from major uranium matrix followed by determination by ICP-MS and high resolution ICP-OES. The residual uranium content of the solution was <10???g/mL. The recovery of REEs ranges from 85 to 105%. The method was validated with nuclear grade uranium oxide standards CRM-I to CRM-V (BARC, Mumbai, India) in addition to some synthetic standards. The RSD of the method was ±12% (n?=?3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号