首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Inagaki K  Haraguchi H 《The Analyst》2000,125(1):191-196
The determination of all rare earth elements (REEs) in human blood serum by inductively coupled plasma mass spectrometry (ICP-MS) was performed with the aid of chelating resin (Chelex 100) preconcentration after acid digestion with HNO3 and HClO4. When chelating resin preconcentration was carried out at room temperature, the recoveries of heavy REEs were lower than those of light REEs because of their stable complex formation with residual organic compounds remaining in the digested serum solution. These problems were overcome by heating the solution at 80 degrees C during the chelating resin preconcentration process. As a result, the recoveries for all REEs were improved to 92-102% in the case of a concentration factor of 4, where the analytical detection limits for REEs were below 0.2 x 10(-12) g ml-1. Consequently, all REEs in individual human blood sera collected from five healthy volunteers could be determined by ICP-MS with good precision. The concentrations of REEs in human blood serum were extremely low, in the range from ca. 1 x 10(-12) g ml-1 of Eu to ca. 230 x 10(-12) g ml-1 of Ce.  相似文献   

2.
A simple and effective procedure is developed to avoid the spectral interference from light rare earth elements (REEs) and barium polyatomic ions on some rare earth elements in inductively coupled plasma mass spectrometry (ICP-MS) by combining algebraic correction with AG50W-×8 cation exchangeable chromatography. Algebraic correction is made to reduce the spectroscopic overlap interference of 141Pr16O and 143Nd16O on 157Gd and 159Tb. The spectroscopic overlap interference of BaO+ and BaOH+ on some middle REEs are overcome by separation of REEs from barium with AG50W-×8 cation exchangeable chromatography. Prior to the determination, REEs are separated from complicated matrix samples using AG50W-×8 cation exchangeable resin. Ba is eluted with 2 mol/l HNO3 solution. REEs are retained and could then be eluted with 5 mol/l HNO3 solution. Recoveries for REEs are from 96 to 110%. More than 99.5% of Ba in the sample is removed, ensuring that the spectral interference from barium polyatomic ions on some middle REEs such as Nd, Sm, Eu and Gd are eliminated. The potential of the proposed method is evaluated by analysis of Certified Reference Materials (CRMs). Results show that experimental data are in good agreement with the certified values. The new technique has been successfully employed for the determination of REEs in practical soil and plant samples.  相似文献   

3.
Hirata S  Kajiya T  Aihara M  Honda K  Shikino O 《Talanta》2002,58(6):1185-1194
A home made column of commercially available iminodiacetate resin, Muromac A-1 (50–100 mesh) was used to concentrate rare earth elements (REEs) (15 elements: Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) in seawater. An automated low pressure flow analysis method with on-line column preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) is described for the determination of REEs in seawater. Sample solutions (adjusted to pH of 3.0) passed through the column. After washing the column with water, the adsorbed elements were subsequently eluted into the plasma with 0.7 M nitric acid. Calibration curves were accomplished by means of purified artificial seawater with a sample loading time of 120 s. Detection limits (DLs) of the on-line column preconcentration/ICP-MS by eight replicate operations were between 0.040 and 0.251 pg ml−1 for REEs in the artificial seawater. The precision was less than 8.9% for REEs and one sample can be processed in 7 min using a 7 ml of sample. The proposed method was applied to determine REEs in coastal seawater of Hiroshima Bay, Japan.  相似文献   

4.
In this work, a new method was developed for the determination of trace rare earth elements (REEs) in biological samples by inductively coupled plasma mass spectrometry (ICP-MS) after preconcentration on a microcolumn packed with modified carbon nanofibers (CNFs). CNFs oxidized with nitric acid have been proved to possess an exceptional adsorption capability for REEs due to their surface functionalization. The effects of the experimental parameters, including pH, sample flow rate and volume, elution solution and interfering ions, on the recoveries of the analytes have been investigated systematically. A 100-fold enrichment factor was obtained. The adsorption capacity of CNFs was found to be 18.1, 19.3, 23.6, 17.6, 22.3 and 19.5 mg/g for La, Ce, Sm, Eu, Dy and Y, respectively. Under the optimum conditions, the detection limits of this method ranged from 0.2 pg/mL (Dy) to 1.2 pg/mL (Ce) with an enrichment factor of 15-fold, and the relative standard deviations (RSDs) for the determination of REEs at the 1.0 ng/mL level were less than 4% (n = 9). This method was applied to the analysis of trace REEs in a real sample of human hair with recoveries of 95-115%. In order to validate the proposed method, a certified reference material of human hair (GBW 07601) was analyzed with satisfactory results.  相似文献   

5.
A new chelating resin, silica gel loaded with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one (PMBP), was prepared and used for the preconcentration of trace amounts of rare earth elements (REEs) in water samples prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). REEs (La, Eu, Yb and Y) were quantitatively retained on the column packed with modified silica gel in the pH range 5 - 8 and separated from the matrix, and then recovered by eluting with 2.0 mol L(-1) HNO3. The adsorption capacity of modified silica gel for La, Eu, Yb and Y was 0.208, 0.249, 0.239 and 0.224 mmol g(-1), respectively. The method has been successfully applied for the determination of La, Eu, Yb and Y in geological and environmental samples with satisfactory results.  相似文献   

6.
A syringe-driven chelating column (SDCC) was applied to develop an on-line preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) method for preconcentration and determination of rare earth elements (REEs) in seawater samples. The present on-line preconcentration system consists of only one pump, two valves, an SDCC, an ICP-MS, several connectors, and Teflon tubes. Optimizations of adsorption pH condition, sample loading flow rate, and integration range were carried out to achieve optimum measurement conditions for REEs in seawater sample. Six minutes was enough for a preconcentration and measurement cycle using 10 mL of seawater sample, where the detection limits for different REEs were in the range of 0.005 pg mL−1 to 0.09 pg mL−1. Analytical results of REEs in a seawater certified reference material (CRM), NASS-5, confirmed the usefulness of the present method. Furthermore, concentrations of REEs in Nikkawa Beach coastal seawater were determined and discussed with shale normalized REE distribution pattern.  相似文献   

7.
Cao X  Yin M  Li B 《Talanta》1999,48(3):517-525
A method was developed for the determination of rare earth impurities in high purity Gd(2)O(3) by inductively coupled plasma mass spectrometry (ICP-MS). The matrix suppression effect of Gd(2)O(3) on signals of rare earth impurities was compensated for by Re internal standardization. The spectra overlap interferences from GdH, GdO, GdOH(n) (n=1-3) on Tb, Tm, Yb and Lu were eliminated by 2-thylhexylhydrogen-2-ethylhexy phosphonate (EHEHP) extraction chromatographic separation. The detection limits for REEs were 0.005-0.017 ng ml(-1) in solution and 0.002-0.05 mug g(-1) in solid. Recoveries of spiked sample for REEs were from 88 to 121% with the precision of 1.0-7.5% RSD. Determination of trace REEs in two Gd(2)O(3) samples were performed. The method can be applied to analysis of 99.99-99.9999% high purity Gd(2)O(3).  相似文献   

8.
Hsieh HF  Chen YH  Wang CF 《Talanta》2011,85(2):983-990
This paper describes a simple method for simultaneous preconcentration and matrix reduction during the analysis of rare earth elements (REEs) in water samples through laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). From a systematic investigation of the co-precipitation of REEs using magnesium hydroxide, we optimized the effects of several parameters - the pH, the amount of magnesium, the shaking time, the efficiency of Ba removal, and the sample matrix - to ensure quantitative recoveries. We employed repetitive laser ablation to remove the dried-droplet samples from the filter medium and introduce them into the ICP-MS system for determinations of REEs. The enrichment factors ranged from 8 to 88. The detection limit, at an enrichment factor of 32, ranged from 0.03 to 0.20 pg mL−1. The relative standard deviations for the determination of REEs at a concentration of 1 ng mL−1 when processing 40 mL sample solution were 2.0-4.8%. We applied this method to the satisfactory determination of REEs in lake water and synthetic seawater samples.  相似文献   

9.
A new method has been developed for the determination of trace rare earth elements (REEs) in water samples based on preconcentration with a microcolumn packed with multiwalled carbon nanotubes (MWNTs) prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimum experimental parameters for preconcentration of REEs, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. The studied REEs ions can be quantitatively retained by MWNTs when the pH exceed 3.0, and then eluted completely with 1.0 mol L−1 HNO3. The detection limits of this method for REEs was between 3 and 57 ng L−1, and the relative standard deviations (RSDs) for the determination of REEs at 10 ng mL−1 level were found to be less than 6% when processing 100 mL sample solution. The method was validated using a certified reference material, and has been successfully applied for the determination of trace rare earth elements in lake water and synthetic seawater with satisfactory results.  相似文献   

10.
A highly selective imprinted amino-functionalized silica gel sorbent was prepared by combining a surface molecular imprinting technique with a sol-gel process for on-line solid-phase extraction-HPLC determination of trace pentachlorophenol (PCP) in water samples. The PCP-imprinted amino-functionalized silica sorbent was characterized by FT-IR, SEM, nitrogen adsorption and the static adsorption experiments. The imprinted functionalized silica gel sorbent exhibited high selectivity and offered a fast kinetics for the adsorption and desorption of PCP. The prepared sorbent was shown to be promising for on-line solid-phase extraction for HPLC determination of trace levels of PCP in environmental samples. With a sample loading flow rate of 5 ml min(-1) for 2 min, an enhancement factor of 670 and a detection limit (S/N = 3) of 6 ng l(-1) were achieved at a sample throughput of five samples h(-1). The precision (RSD) for nine replicate on-line sorbent extractions of 10 microgl(-1) PCP was 3.8%. The sorbent also offered good linearity (r = 0.9997) for on-line solid-phase extraction of trace levels of PCP. The method was applied to the determination of PCP in local lake water, river water and wastewater samples.  相似文献   

11.
A novel method of online microcolumn separation and preconcentration coupled to inductively coupled plasma atomic emission spectrometry (ICP-AES) with the use of acetylacetone-modified silica gel as packing material was developed for the determination of trace rare earth elements (REEs) in environmental and food samples. The main parameters affecting online separation/preconcentration, including pH, sample flow rate, sample volume, elution and interfering ions, have been investigated in detail. Under the optimized operating conditions, the adsorption capacity values for Sc, Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu were 25.65, 23.23, 24.01, 19.40, 22.89, 23.77, 24.40, 23.96, 25.58, 25.15, 24.86, 22.75, 16.05, 24.13, 26.51 and 27.93 mg g(-1), respectively. Detection limits (3sigma) based on three times standard deviations of the blanks by 8 replicates were in the range from 48 pg mL(-1) for Lu to 1003 pg mL(-1) for Sm. With 90 s preconcentration time and 10 s elution time, the enrichment factor was 10 and the sample frequency was 28 h(-1). The precisions (RSDs) obtained by determination of a 250 ng mL(-1) (n = 8) REEs standard solution were in the range from 1.7% for Y to 4.4% for Sm. The proposed method was successfully applied to the determination of trace REEs in pig liver, agaric and mushroom. To validate the proposed method, we analyzed three certified reference materials (GBW07401 soil, GBW07301a sediment, and GBW07605 tea leaves). The determined values were in a good agreement with the certified values. The method is rapid, selective, sensitive and applicable to the determination of trace REEs in biological and environmental samples with complicated matrix effects.  相似文献   

12.
建立了聚丙烯酸螯合-超滤( PCP - UF)分离富集、电感耦合等离子体质谱(ICP - MS)测定海水中痕量稀土及金属元素的方法.pH值高于7.5时,海水中的稀土离子、Cu2、pb2、Cd2、Co2、Ni2+等与聚丙烯酸(PAA)形成稳定的高分子螯合物,经超滤截留、硝酸解离后,实现了稀土及金属元素从海水中的分离、富集...  相似文献   

13.
Dwinna Rahmi 《Talanta》2007,72(2):600-606
The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200-400 mesh), with which trace metals in 50 mL of original seawater sample were concentrated into 0.50 mL of 2 M nitric acid, and then 100-fold preconcentration of trace metals was achieved. Then, 0.50 mL analysis solution was subjected to the multielement determination by ICP-MS equipped with a MicroMist nebulizer for micro-sampling introduction. The preconcentration and elution parameters such as the sample-loading flow rate, the amount of 1 M ammonium acetate for elimination of matrix elements, and the amount of 2 M nitric acid for eluting trace metals were optimized to obtain good recoveries and analytical detection limits for trace metals. The analytical results for V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U in three kinds of seawater certified reference materials (CRMs; CASS-3, NASS-4, and NASS-5) agreed well with their certified values. The observed values of rare earth elements (REEs) in the above seawater CRMs were also consistent with the reference values. Therefore, the compiled reference values for the concentrations of REEs in CASS-3, NASS-4, and NASS-5 were proposed based on the observed values and reference data for REEs in these CRMs.  相似文献   

14.
Methods are described for the determination of trace and ultra trace amounts of Cd, Co, Cr, Cu, Fe, Mn, Ni and Pb in natural waters, alkali and alkaline earth salts. Separation and preconcentration of trace metals is achieved by a column solid phase extraction procedure using silica gel modified with derivatives of dithiocarbamates — Na-DDTC (sodium diethyldithio-carbamate and HMDTC (ammonium hexamethylene-dithiocarbamate) as column packing material. The influence of the sorbent preparation procedure on the degree of sorption of the trace analytes is examined for different pH values of the sample solution. Isobutylmethyl ketone (IBMK) is proposed as an effective eluent for quantitative elution of retained metal ions. Optimal instrumental parameters for ETAAS determination of preconcentrated elements in organic eluate are presented. Practical application of sorbents in analysis of natural waters and alkali and alkaline earth salts is demonstrated. Proposed preconcentration procedure combined with ETAAS determination of trace analytes allows the determination of 0.04 g l–1 Cd, 0.1 g l–1 Cr, Cu, and Mn and 0.3 g l–1 Co, Fe, Ni and Pb in natural waters and 1.10–7% Cd, 3.10–7% Cr and Mn, 7.10–7% Co, Ni and Pb and 2.10–6% Cu and Fe in alkali and alkaline earth salts.  相似文献   

15.
The usage of a variety of sorbents has been shown as promising matrix removal/preconcentration strategies for the determination of rare earth elements (REEs) in various natural water samples by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sorption efficiency of various zeolites (clinoptilolite, mordenite, zeolite Y, zeolite Beta), ion-exchangers (Amberlite CG-120, Amberlite IR-120, Rexyn 101, Dowex 50W X18) and chelating resins (Muromac, Chelex 100, Amberlite IRC-718) towards REEs was investigated in terms of solution pH, shaking time and sorbent amount. The results have shown that most of the materials can take up REEs at a wide pH range. The experiments were continued with clinoptilolite, zeolite Y and Chelex 100 and it was demonstrated that all three materials displayed very fast kinetics for REE sorption (higher than 96% in 1 min). Desorption from the sorbents was realized with 2.0 M HNO3 for clinoptilolite and 0.1 M HNO3 for zeolite Y and Chelex 100. Only the lower concentration range (0.01-2.0 mg l−1) of matrix-matched standards were used in quantitation although the calibration graphs were linear at least up to 10.0 mg l−1 for all REEs studied. The limit of detection (3 s) without preconcentration was 0.1, 1.0, and 0.2 μg l−1 for Eu, La, and Yb, respectively. The validity of the method with the selected sorbents was checked through spike recovery experiments.  相似文献   

16.
The determination of 34 trace metals in a river water certified reference material (CRM), i.e. JSAC 0301-1, which was issued by the Japan Society for Analytical Chemistry in January 2004, was performed by ICP-MS with a high efficiency nebulizer after preconcentration with a laboratory-made chelating resin-packed minicolumn, with which trace metals were concentrated 100-fold from 50 mL of a river water sample to 0.5 mL of the final analysis solution. Trace metals in JSAC 0301-1 were observed in the concentration range from 19 microg L(-1) of Al to 0.000053 microg L(-1) of Bi. It was found that most of the concentrations of trace metals, including rare earth elements (REEs), in JSAC 0301-1 were lower than those in JAC 0031, which was also a previously issued CRM prepared with water from the same river as that of JSAC 0301-1. The low concentrations of trace metals in JSAC 0301-1 might be attributed to the fact that there was a heavy rain before collecting the original water sample to prepare the present CRM. Furthermore, the REE distribution patterns of JSAC 0301-1, JAC 0031 and the average values of river water samples in Japan were parallel to each other. These results indicate that the distributions of REEs in JSAC 0301-1 and JAC 0031 were the typical ones of river water samples in Japan.  相似文献   

17.
A flow injection system incorporating an alumina microcolumn has been coupled to inductively coupled plasma mass spectrometry (ICP-MS) for on-line preconcentration and determination of platinum (IV) in natural waters. Depending on the nature of the sample, a nominal preconcentration factor of up to 600 can be achieved by eluting with 50microl of 2 mol/l NH(4)OH. The limit of detection after a 5 min preconcentration time was 4 ngl(-1), with a relative standard deviation of 4% (100 ngl(-1) working solution). The proposed method was assessed for the determination of platinum (IV) in natural waters, motor car exhaust and some common analytical reagents.  相似文献   

18.
Qiang Fu  Qiuquan Wang 《Talanta》2007,72(4):1248-1254
A newly synthesized alkyl phosphinic acid resin (APAR) was used for on-line preconcentration of trace rare earth elements (REES, lanthanides including yttrium) and then determined by inductively coupled plasma mass spectrometry. REEs in seawater could be on-line concentrated on the APAR packed column (4.6 mm i.d. × 50 mm in length), and eluted from the column with 0.5 mL 0.1 mol L−1 nitric acid within 30 s. An enrichment factor of nearly 400 was achieved for all REEs when the seawater sample volume was 200 mL, while the matrix and coexisting spectrally interfering ions such as barium, tin and antimony could be simultaneously separated. The detection limits of this proposed method for REEs were in the range from 1.43 pg L−1 of holmium to 12.7 pg L−1 of lanthanum. The recoveries of REEs were higher than 97.9%, and the precision of the relative standard deviation (R.S.D., n = 6) was less than 5%. The method has been applied to the determination of soluble REEs in seawater.  相似文献   

19.
Lee KH  Oshima M  Motomizu S 《The Analyst》2002,127(6):769-774
A new on-line flow injection (FI) pre-treatment system using a disk-type chelating resin (5 mm diameter, 0.5 mm thickness) was developed for the simultaneous multi-element determination of trace metals in sea-water samples by inductively coupled plasma mass spectrometry (ICP-MS). A chelating resin possessing an iminodiacetate (IDA) functional group was used for the collection of trace elements and the elimination of alkali and alkaline earth metals in highly concentrated salt solution. A 1 ml volume of a sea-water sample (pH 5.5) was applied to the chelating resin disk. Considering the removal efficiency for Ca, 50 mM ammonium acetate buffer solution (pH 5.5) was chosen as a sample carrier. The enriched trace metals were eluted with 0.1 M nitric acid and the eluate flowed into the ICP-MS system. The processing time for one sample was < 6 min (350 s). One of the important observations is the possibility of working with a low recovery, even lower than 50%. For example, several elements such as Mn, Cr, As, Mo, Ba and U, the recovery of which was < 50% in a batch-wise method, showed good linearity and reproducibility. The proposed method was evaluated by analyzing two kinds of sea-water certified reference materials, CASS-4 and NASS-5. Analytical data for eight heavy metals, V, Mn, Co, Ni, Cu, Mo, Cd and U, obtained from the present study agreed well with the certified values.  相似文献   

20.
《Analytical letters》2012,45(11):2105-2115
Abstract

Systematic investigations were carried out into the sorption of rare earth elements (REEs) on carbon nonofibers (CNFs) by inductively coupled plasma mass spectrometry (ICP‐MS). The experimental parameters for preconcentration of REEs, such as pH, sample flow rate and volume, eluent concentration, and interfering ions on preconcentration of REEs have been examined in detail. The studied metal ions can be adsorbed quantitatively on CNFs in a pH range from 2.0 to 5.0, and then eluted completely with 0.5 mol l?1 HNO3. Based on the above facts, a novel method using a microcolumn packed with carbon nanofibers as an adsorption material was developed for the separation and preconcentration of REEs prior to their determination by ICP‐MS. The proposed method has been successfully applied to the determination of light (La), medium (Eu and Gd) and heavy (Yb) rare earth elements in real sample with the recovery more than 90%. In order to validate this method, two certified reference materials of tea leaves (GBW 07605) and mussel (GBW 08571) were analyzed, and the determined values are in good agreement with the certified values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号